Skip to main content
Erschienen in: Journal of Medical Systems 3/2019

01.03.2019 | Systems-Level Quality Improvement

Performance Evaluation of Jaipur Knee Joint through Kinematics and Kinetics Gait Symmetry with Unilateral Transfemoral Indian Amputees

verfasst von: Pawan Mishra, Sachin Singh, Vinayak Ranjan, Sonu Singh, Ankit Vidyarthi

Erschienen in: Journal of Medical Systems | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Gait analysis is considered as the most systematic study of human motion. The analysis of gait includes visual and analytical perception of the individual, augmentation of various mechanical instrumentations for measuring movement of body, muscles activity and body mechanics. Past study focused on gait analysis of various animal locomotion and humans mainly on sports biomechanics. This paper aims to quantify the gait performance with Jaipur Knee, which is one of the most widely used prosthesis in Indian population. Gait data with Jaipur knee joint is not available till date. The proposed study targets to predict the performance of Jaipur knee joint in terms of gait symmetry with transfemoral Indian amputees. Gait symmetry may be the basis of recommendation of knee joint to prosthetic patients. This study used kinematics and kinetics parameters together to quantify the performance of Jaipur knee joint to evaluate gait symmetry. This research will be helpful for clinician to predict and further to prevent the degenerated musculoskeletal effects generally seen in unilateral transfemoral amputees.
Literatur
1.
Zurück zum Zitat Hodgins, D., The importance of measuring human gait. Med. Device Technol. 19(5):44–47, 2008. Hodgins, D., The importance of measuring human gait. Med. Device Technol. 19(5):44–47, 2008.
2.
Zurück zum Zitat Balzac, H. D., Theorie de la Demarche. Paris: Didier, 1853. Balzac, H. D., Theorie de la Demarche. Paris: Didier, 1853.
3.
Zurück zum Zitat Collado Vazqueza, S., and Carrillo, J., Balzac and human gait analysis. Neurologia 30(4):240–246, 2015.CrossRef Collado Vazqueza, S., and Carrillo, J., Balzac and human gait analysis. Neurologia 30(4):240–246, 2015.CrossRef
4.
Zurück zum Zitat Tamakrishnan, T., Lahiff, C., and Reed, K. B., Comparing gait with multiple physical asymmetries using consolidated metrices. Frontoers in Nerorobotics 12(2):1–12, 2018. Tamakrishnan, T., Lahiff, C., and Reed, K. B., Comparing gait with multiple physical asymmetries using consolidated metrices. Frontoers in Nerorobotics 12(2):1–12, 2018.
7.
Zurück zum Zitat Jaegers, S. M. H. J., Arendzen, J. H., and De Jongh, H. J.: The prosthetic gait of unilateral transfemoral amputees: a kinematic study. 76(8):736–43, 1995 Jaegers, S. M. H. J., Arendzen, J. H., and De Jongh, H. J.: The prosthetic gait of unilateral transfemoral amputees: a kinematic study. 76(8):736–43, 1995
8.
Zurück zum Zitat Bautmans, I., Jansen, B., Van Keymolen, B., and Mets, T., Reliability and clinical correlates of 3D-accelerometry based gait analysis outcomes according to age and fall-risk. Gait Posture 33(3):366–72, 2011.CrossRef Bautmans, I., Jansen, B., Van Keymolen, B., and Mets, T., Reliability and clinical correlates of 3D-accelerometry based gait analysis outcomes according to age and fall-risk. Gait Posture 33(3):366–72, 2011.CrossRef
9.
Zurück zum Zitat Kulkarni, J., Adams, J., Thomas, E., and Silman, A., Association between amputation, arthritis and osteopenia in british male war veterans with major lower limb amputations. Clin. Rehabil. 12:348–353, 1998.CrossRef Kulkarni, J., Adams, J., Thomas, E., and Silman, A., Association between amputation, arthritis and osteopenia in british male war veterans with major lower limb amputations. Clin. Rehabil. 12:348–353, 1998.CrossRef
10.
Zurück zum Zitat Johansson, J., Sherrill, D., Riley, P., Bonato, P., and Herr, H., A clinical coparison of variable damping and mechanically passive prosthetic knee devices. Am. J. Phys. Med. Rehabil. 84:563–575, 2005.CrossRef Johansson, J., Sherrill, D., Riley, P., Bonato, P., and Herr, H., A clinical coparison of variable damping and mechanically passive prosthetic knee devices. Am. J. Phys. Med. Rehabil. 84:563–575, 2005.CrossRef
11.
Zurück zum Zitat Jaroslav, U., Jandacka, D., Farana, R., Zahradnik, D., Rosicky, J., and Janura, M., Kinematics of gait using bionic and hydraulic knee joints in transfemoral amputees. Acta Gymnica 47(3):130–137, 2017.CrossRef Jaroslav, U., Jandacka, D., Farana, R., Zahradnik, D., Rosicky, J., and Janura, M., Kinematics of gait using bionic and hydraulic knee joints in transfemoral amputees. Acta Gymnica 47(3):130–137, 2017.CrossRef
12.
Zurück zum Zitat Robinson, R., Herzog, W., and Nigg, B., Use of force plateform variables to quantify the effects of chiropractic manipulation on gait symmetry. Manipulative Physiotherapy 10:172–176 , 1987. Robinson, R., Herzog, W., and Nigg, B., Use of force plateform variables to quantify the effects of chiropractic manipulation on gait symmetry. Manipulative Physiotherapy 10:172–176 , 1987.
13.
Zurück zum Zitat Zifchock, R., Davis, I., and Higginson, J. R. T., Asymmetry angle: a novel, robust method of quantifying asymmetry. Gait Posture 27:622–627, 2008.CrossRef Zifchock, R., Davis, I., and Higginson, J. R. T., Asymmetry angle: a novel, robust method of quantifying asymmetry. Gait Posture 27:622–627, 2008.CrossRef
14.
Zurück zum Zitat Sadeghi, H., Local or global asymmetry in gait of people without impairments. Gait Posture 17:197–204, 2003.CrossRef Sadeghi, H., Local or global asymmetry in gait of people without impairments. Gait Posture 17:197–204, 2003.CrossRef
15.
Zurück zum Zitat Haddad, J., Van Emmerik, R., Whittlesey, S., and Hamill, J., Adaptions in interlimb and intralimb coordination to asymmetrical loading in human walking. Gait Posture 23:429–434 , 2006.CrossRef Haddad, J., Van Emmerik, R., Whittlesey, S., and Hamill, J., Adaptions in interlimb and intralimb coordination to asymmetrical loading in human walking. Gait Posture 23:429–434 , 2006.CrossRef
16.
Zurück zum Zitat Al-Fatafta, H., Liu, A., Hutchins, S., and Jones, R.: Knee joint kinematics and kinetics during the force plate attachable interlaced stairway climbing (FPAIS) in healthy individuals. Prosthetics and Orthotics Open Journal:1–15, 2017 Al-Fatafta, H., Liu, A., Hutchins, S., and Jones, R.: Knee joint kinematics and kinetics during the force plate attachable interlaced stairway climbing (FPAIS) in healthy individuals. Prosthetics and Orthotics Open Journal:1–15, 2017
17.
Zurück zum Zitat Yang, L., Solomonidis, S., and Spence, W. P. J., The influence of limb alignment on the gait of above knee amputees. J. Biomech. 24:981–997, 1991.CrossRef Yang, L., Solomonidis, S., and Spence, W. P. J., The influence of limb alignment on the gait of above knee amputees. J. Biomech. 24:981–997, 1991.CrossRef
18.
Zurück zum Zitat Blumentritt, S., A new biomechanical method for determination of static prosthetic alignment. Prosthetics Orthot. Int. 21:107–113, 1997. Blumentritt, S., A new biomechanical method for determination of static prosthetic alignment. Prosthetics Orthot. Int. 21:107–113, 1997.
19.
Zurück zum Zitat Crenshaw, S., and Richards, J., A method for analyzing joint symmetry abnormally with an applications to analyzing gait. Gait Posture 24:515–521, 2006.CrossRef Crenshaw, S., and Richards, J., A method for analyzing joint symmetry abnormally with an applications to analyzing gait. Gait Posture 24:515–521, 2006.CrossRef
20.
Zurück zum Zitat Kaufman, K., Levine, J., Brey, R., Mccrady, S., Padgett, D., and Joyner, M., Energy expenditure and activity of transfemoral amputees using mechanical and microprocesssor controlled prosthetic knees. Arch. Phys. Med. Rehabil. 87:1382–1385 , 2008. Kaufman, K., Levine, J., Brey, R., Mccrady, S., Padgett, D., and Joyner, M., Energy expenditure and activity of transfemoral amputees using mechanical and microprocesssor controlled prosthetic knees. Arch. Phys. Med. Rehabil. 87:1382–1385 , 2008.
21.
Zurück zum Zitat Lelas, J., Merriman, G., Riley, P., and Kerrigan, D., Predicting peak kinematic and kinetic parameters from gait speed. Gait Posture 17:106–112, 2003.CrossRef Lelas, J., Merriman, G., Riley, P., and Kerrigan, D., Predicting peak kinematic and kinetic parameters from gait speed. Gait Posture 17:106–112, 2003.CrossRef
22.
Zurück zum Zitat Nolan, L., Wit, A., Dudzinski, K., Lees, A., Lake, M., and Wychowansky, M., Adjustments in gait symmetry with walking speed in transfemoral and trandtibial amputees. Gait Posture 17:142–151, 2003.CrossRef Nolan, L., Wit, A., Dudzinski, K., Lees, A., Lake, M., and Wychowansky, M., Adjustments in gait symmetry with walking speed in transfemoral and trandtibial amputees. Gait Posture 17:142–151, 2003.CrossRef
Metadaten
Titel
Performance Evaluation of Jaipur Knee Joint through Kinematics and Kinetics Gait Symmetry with Unilateral Transfemoral Indian Amputees
verfasst von
Pawan Mishra
Sachin Singh
Vinayak Ranjan
Sonu Singh
Ankit Vidyarthi
Publikationsdatum
01.03.2019
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 3/2019
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-019-1181-0

Weitere Artikel der Ausgabe 3/2019

Journal of Medical Systems 3/2019 Zur Ausgabe