Skip to main content
Erschienen in: Environmental Health and Preventive Medicine 2/2015

01.03.2015 | Regular Article

Peripheral viewing during exposure to a 2D/3D video clip: effects on the human body

verfasst von: Masumi Takada, Yuta Fukui, Yasuyuki Matsuura, Motohiko Sato, Hiroki Takada

Erschienen in: Environmental Health and Preventive Medicine | Ausgabe 2/2015

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Symptoms of three-dimensional (3D) sickness, such as intoxication and eye fatigue, have been observed in subjects viewing 3D films and vary according to the image quality and visual environment. In addition, the influence of stereoscopic vision on the incidence of 3D sickness has not been explored sufficiently. Therefore, it is important to examine the safety of viewing virtual 3D content.

Methods

The present study examines the effects of peripheral vision on reported motion sickness during exposure to 2D/3D video clips for 1 min and for 1 min afterwards in human subjects. Stabilograms were recorded during exposure to video clips with or without visual pursuit of a 3D object and compared, and subjects were administered the simulator sickness questionnaire after stabilometry.

Results

There were no significant main effects of solidity of the visual stimulous (2D/3D) and the vision method (visual pursuit/peripheral viewing) in accordance with the two-way analysis of variance of the sway values, although the sway values during the 2D/3D video clips were higher than in control subjects. A consistent trend in the main effect of stability was observed. Further, the sway values changed remarkably after the 3D video clip was viewed peripherally and produced a persistent instability in equilibrium function. The questionnaire findings also significantly changed after the subjects viewed the video clips peripherally.

Conclusions

Subjective exacerbation and deterioration of equilibrium function were observed after peripheral viewing of 3D video clips. This persistent influence may result when subjects view a poorly depicted background element peripherally, which generates depth perception that contradicts daily experience.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Malik AS, Choi TS, Nisar H (editors). Depth map and 3D imaging applications: algorithms and technologies. Hershey, PA, USA, Proc IGI Global Hershey. 2011. Malik AS, Choi TS, Nisar H (editors). Depth map and 3D imaging applications: algorithms and technologies. Hershey, PA, USA, Proc IGI Global Hershey. 2011.
2.
Zurück zum Zitat Okawa T, Tokita T, Shibata Y, Ogawa T, Miyata H. Stabilometry: significance of locus length per unit area (L/A) in patients with equilibrium disturbances. Equilib Res. 1995;55:283–93 (in Japanese).CrossRef Okawa T, Tokita T, Shibata Y, Ogawa T, Miyata H. Stabilometry: significance of locus length per unit area (L/A) in patients with equilibrium disturbances. Equilib Res. 1995;55:283–93 (in Japanese).CrossRef
3.
Zurück zum Zitat Kaga K, Memaino K. Structure of vertigo. Tokyo: Kanehara; 1992 (in Japanese). Kaga K, Memaino K. Structure of vertigo. Tokyo: Kanehara; 1992 (in Japanese).
4.
Zurück zum Zitat Okawa T, Tokita T, Shibata Y, Ogawa T, Miyata H. Stabilometry: significance of locus length per unit area (L/A). Equilib Res. 1995;54:296–306 (in Japanese).CrossRef Okawa T, Tokita T, Shibata Y, Ogawa T, Miyata H. Stabilometry: significance of locus length per unit area (L/A). Equilib Res. 1995;54:296–306 (in Japanese).CrossRef
5.
Zurück zum Zitat Takada H, Kitaoka Y, Ichikawa S, Miyao M. Physical meaning on geometrical index for stabilometry. Equilib Res. 2003;62:168–80 (in Japanese).CrossRef Takada H, Kitaoka Y, Ichikawa S, Miyao M. Physical meaning on geometrical index for stabilometry. Equilib Res. 2003;62:168–80 (in Japanese).CrossRef
6.
Zurück zum Zitat Takada H, Kitaoka Y, Shimizu Y. Mathematical index and model in stabilometry. Forma. 2001;16:17–46. Takada H, Kitaoka Y, Shimizu Y. Mathematical index and model in stabilometry. Forma. 2001;16:17–46.
7.
Zurück zum Zitat Takada H, Fujikake K, Miyao M, Matsuura Y. Indices to detect visually induced motion sickness using stabilometry. In: Proc VIMS. 2007. p. 178–83. Takada H, Fujikake K, Miyao M, Matsuura Y. Indices to detect visually induced motion sickness using stabilometry. In: Proc VIMS. 2007. p. 178–83.
8.
Zurück zum Zitat Wann J, Rushton S, Mon Williams M. Natural problems for stereoscopic depth perception in virtual environments. Vis Res. 1995;35:2731–6.CrossRefPubMed Wann J, Rushton S, Mon Williams M. Natural problems for stereoscopic depth perception in virtual environments. Vis Res. 1995;35:2731–6.CrossRefPubMed
9.
Zurück zum Zitat Yasui R, Matsuda I, Kakeya H. Combining volumetric edge display and multiview display for expression of natural 3D images. Proc SPIE. 2006;6055:0Y1–9. Yasui R, Matsuda I, Kakeya H. Combining volumetric edge display and multiview display for expression of natural 3D images. Proc SPIE. 2006;6055:0Y1–9.
10.
Zurück zum Zitat Kakeya H. MOEVision: simple multiview display with clear floating image. Proc SPIE. 2007;6490:64900J.CrossRef Kakeya H. MOEVision: simple multiview display with clear floating image. Proc SPIE. 2007;6490:64900J.CrossRef
11.
Zurück zum Zitat Kennedy RS, Lane NE, Berbaum KS, Lilienthal MG. A simulator sickness questionnaire (SSQ): a new method for quantifying simulator sickness. Int J Aviat Psychol. 1993;3:203–20.CrossRef Kennedy RS, Lane NE, Berbaum KS, Lilienthal MG. A simulator sickness questionnaire (SSQ): a new method for quantifying simulator sickness. Int J Aviat Psychol. 1993;3:203–20.CrossRef
12.
Zurück zum Zitat Holomes SR, Griffin MJ. Correlation between heart rate and the severity of motion sickness caused by optokinetic stimulation. J Psychophysiol. 2001;15:35–42.CrossRef Holomes SR, Griffin MJ. Correlation between heart rate and the severity of motion sickness caused by optokinetic stimulation. J Psychophysiol. 2001;15:35–42.CrossRef
13.
Zurück zum Zitat Himi N, Koga T, Nakamura E, Kobashi M, Yamane M, Tsujioka K. Differences in autonomic responses between subjects with and without nausea while watching an irregularly oscillating video. Auton Neurosci. 2004;116:46–53.CrossRefPubMed Himi N, Koga T, Nakamura E, Kobashi M, Yamane M, Tsujioka K. Differences in autonomic responses between subjects with and without nausea while watching an irregularly oscillating video. Auton Neurosci. 2004;116:46–53.CrossRefPubMed
14.
Zurück zum Zitat Yokota Y, Aoki M, Mizuta K. Motion sickness susceptibility associated with visually induced postural instability and cardiac autonomic responses in healthy subjects. Acta Otolaryngol. 2005;125:280–5.CrossRefPubMed Yokota Y, Aoki M, Mizuta K. Motion sickness susceptibility associated with visually induced postural instability and cardiac autonomic responses in healthy subjects. Acta Otolaryngol. 2005;125:280–5.CrossRefPubMed
15.
Zurück zum Zitat Scibora LM, Villard S, Bardy B, Stoffregen TA. Wider stance reduces body sway and motion sickness. In: Proc VIMS. 2007. p. 18–23. Scibora LM, Villard S, Bardy B, Stoffregen TA. Wider stance reduces body sway and motion sickness. In: Proc VIMS. 2007. p. 18–23.
16.
Zurück zum Zitat Fujikake K, Miyao M, Watanabe T, Hasegawa S, Omori M, Takada H. Evaluation of body sway and the relevant dynamics while viewing a three-dimensional movie on a head-mounted display by using stabilograms. In: Shumaker R, editor. Lecture notes in computer science. Berlin, Heidelberg: Springer; 2009. p. 41–50. Fujikake K, Miyao M, Watanabe T, Hasegawa S, Omori M, Takada H. Evaluation of body sway and the relevant dynamics while viewing a three-dimensional movie on a head-mounted display by using stabilograms. In: Shumaker R, editor. Lecture notes in computer science. Berlin, Heidelberg: Springer; 2009. p. 41–50.
17.
Zurück zum Zitat Takada M, Murakami K, Kunida Y, Hirata T, Matsuura Y, Iwase S, et al. Effect of hour-long stereoscopic film on equilibrium function. In: Proc IMID Digest. 2011. p. 737–38. Takada M, Murakami K, Kunida Y, Hirata T, Matsuura Y, Iwase S, et al. Effect of hour-long stereoscopic film on equilibrium function. In: Proc IMID Digest. 2011. p. 737–38.
18.
Zurück zum Zitat Yoshikawa K, Takada H, Miyao M. Effect of display size on body sway in seated posture while viewing an hour-long stereoscopic film. In: Stephanidis C, Antona M, editors. UAHCI/HCII 2013 part II, LNCS 8010. Berlin, Heidelberg: Springer; 2013. p. 336–41. Yoshikawa K, Takada H, Miyao M. Effect of display size on body sway in seated posture while viewing an hour-long stereoscopic film. In: Stephanidis C, Antona M, editors. UAHCI/HCII 2013 part II, LNCS 8010. Berlin, Heidelberg: Springer; 2013. p. 336–41.
19.
Zurück zum Zitat Suzuki J, Matsunaga T, Tokumatsu K, Taguchi K, Watanabe I. Q & A and a manual in stabilometry. Equilib Res. 1996;55:64–77 (in Japanese).CrossRef Suzuki J, Matsunaga T, Tokumatsu K, Taguchi K, Watanabe I. Q & A and a manual in stabilometry. Equilib Res. 1996;55:64–77 (in Japanese).CrossRef
20.
Zurück zum Zitat Hollander M, Wolfe DA. Nonparametric statistical methods. New York-Sydney-Tokyo-Mexico City: Wiley; 1973. Hollander M, Wolfe DA. Nonparametric statistical methods. New York-Sydney-Tokyo-Mexico City: Wiley; 1973.
21.
Zurück zum Zitat Nishihira T, Tahara H. Apparatus for recovering eyesight utilizing stereoscopic video and method for displaying stereoscopic video. US. Patent. 2002;US7404693B2. Nishihira T, Tahara H. Apparatus for recovering eyesight utilizing stereoscopic video and method for displaying stereoscopic video. US. Patent. 2002;US7404693B2.
22.
Zurück zum Zitat Takada M, Miyao M, Satoh M, Yoshikawa K, Matsuura Y, Takada H. Effect of accommodation training on visual function of visual inspection workers and middle-aged people. J Sports Med Doping Stud. 2012;. doi:10.4172/2161-0673.1000112. Takada M, Miyao M, Satoh M, Yoshikawa K, Matsuura Y, Takada H. Effect of accommodation training on visual function of visual inspection workers and middle-aged people. J Sports Med Doping Stud. 2012;. doi:10.​4172/​2161-0673.​1000112.
23.
Zurück zum Zitat Miyao M, Ishihara S, Saito S, Kondo T, Sakakibara H, Toyoshima H. Visual accommodation and subject performance during a stereographic object task using liquid crystal shutters. Ergonomics. 1996;39:1294–309.CrossRefPubMed Miyao M, Ishihara S, Saito S, Kondo T, Sakakibara H, Toyoshima H. Visual accommodation and subject performance during a stereographic object task using liquid crystal shutters. Ergonomics. 1996;39:1294–309.CrossRefPubMed
24.
Zurück zum Zitat Shiomi T, Uemoto K, Kojima T, Sano S, Ishio H. Simultaneous measurement of lens accommodation and convergence in natural and artificial 3D vision. J Soc Inf Disp. 2013;21:120–8.CrossRef Shiomi T, Uemoto K, Kojima T, Sano S, Ishio H. Simultaneous measurement of lens accommodation and convergence in natural and artificial 3D vision. J Soc Inf Disp. 2013;21:120–8.CrossRef
26.
Zurück zum Zitat Patterson R. Human factors of stereo displays: an update. J Soc Inf Disp. 2009;17:987–96.CrossRef Patterson R. Human factors of stereo displays: an update. J Soc Inf Disp. 2009;17:987–96.CrossRef
27.
Zurück zum Zitat Miyao M, Shiomi T, Hori H, Hasegawa A, Matsuura Y, Takada H, et al. Comparison of 2D and 3D vision gaze with simultaneous measurements of accommodation and convergence among young and middle-aged subjects. In: Proc IMID Digest. 2011. p. 149–50. Miyao M, Shiomi T, Hori H, Hasegawa A, Matsuura Y, Takada H, et al. Comparison of 2D and 3D vision gaze with simultaneous measurements of accommodation and convergence among young and middle-aged subjects. In: Proc IMID Digest. 2011. p. 149–50.
28.
Zurück zum Zitat Kojima T, Matsuura Y, Miyao M, Shiomi T, Takada H. Comparison by simultaneous measurement of lens accommodation and convergence in 3D vision and their distributions. Int J Biosci Biochem Bioinforma. 2013;3:635–8. Kojima T, Matsuura Y, Miyao M, Shiomi T, Takada H. Comparison by simultaneous measurement of lens accommodation and convergence in 3D vision and their distributions. Int J Biosci Biochem Bioinforma. 2013;3:635–8.
29.
Zurück zum Zitat Patterson R, Silzars A. Immersive stereo displays, intuitive reasoning, and cognitive engineering. J Soc Inf Disp. 2009;17:443–8.CrossRef Patterson R, Silzars A. Immersive stereo displays, intuitive reasoning, and cognitive engineering. J Soc Inf Disp. 2009;17:443–8.CrossRef
30.
Zurück zum Zitat Nagata S. Distribution of “vergence fusional stereoscopic limits (VFSL)” of disparity in a stereoscopic display. TVRSJ. 2002;7:239–46 (in Japanese). Nagata S. Distribution of “vergence fusional stereoscopic limits (VFSL)” of disparity in a stereoscopic display. TVRSJ. 2002;7:239–46 (in Japanese).
31.
Zurück zum Zitat Takada M, Uemoto K, Miyao M, Matsuura Y, Satoh M, Takada H. Comparison of fixation distances in middle-aged subjects. Int J Biosci Biochem Bioinforma. 2013;2:389–94. Takada M, Uemoto K, Miyao M, Matsuura Y, Satoh M, Takada H. Comparison of fixation distances in middle-aged subjects. Int J Biosci Biochem Bioinforma. 2013;2:389–94.
32.
Zurück zum Zitat Takada H, Kitaoka Y, Iwase S, Shimizu Y, Watanabe T, Nakayama M, Miyao M, Mihashi K. Characteristic changes of sway of center of gravity with advancing age. Environ Med. 2004;47:85–9. Takada H, Kitaoka Y, Iwase S, Shimizu Y, Watanabe T, Nakayama M, Miyao M, Mihashi K. Characteristic changes of sway of center of gravity with advancing age. Environ Med. 2004;47:85–9.
33.
Zurück zum Zitat Kato Z, Okubo T. Methods to measure bio functions for beginners. Tokyo: Nihon Shuppan Service Co, Ltd; 1999 (in Japanese). Kato Z, Okubo T. Methods to measure bio functions for beginners. Tokyo: Nihon Shuppan Service Co, Ltd; 1999 (in Japanese).
34.
Zurück zum Zitat Sugiura A, Miyao M, Yamamoto T, Takada H. Effect of strategic accommodation training by wide stereoscopic movie presentation on myopic young people of visual acuity and asthenopia. Displays. 2011;32(4):219–24.CrossRef Sugiura A, Miyao M, Yamamoto T, Takada H. Effect of strategic accommodation training by wide stereoscopic movie presentation on myopic young people of visual acuity and asthenopia. Displays. 2011;32(4):219–24.CrossRef
35.
Zurück zum Zitat Goldie PA, Bach TM, Evans OM. Force platform measures for evaluating postural control: reliability and validity. Arch Phys Med Rehabil. 1986;70:510–7. Goldie PA, Bach TM, Evans OM. Force platform measures for evaluating postural control: reliability and validity. Arch Phys Med Rehabil. 1986;70:510–7.
36.
Zurück zum Zitat Collins JJ, De Luca CJ. Open-loop and closed-loop control of posture: a random-walk analysis of center of pressure trajectories. Exp Brain Res. 1993;95:308–18.CrossRefPubMed Collins JJ, De Luca CJ. Open-loop and closed-loop control of posture: a random-walk analysis of center of pressure trajectories. Exp Brain Res. 1993;95:308–18.CrossRefPubMed
37.
Zurück zum Zitat Newell KM, Slobounova SM, Slobounov ES, Molenaar PC. Stochastic processes in postural center-of-pressure profiles. Exp Brain Res. 1997;113:158–64.CrossRefPubMed Newell KM, Slobounova SM, Slobounov ES, Molenaar PC. Stochastic processes in postural center-of-pressure profiles. Exp Brain Res. 1997;113:158–64.CrossRefPubMed
Metadaten
Titel
Peripheral viewing during exposure to a 2D/3D video clip: effects on the human body
verfasst von
Masumi Takada
Yuta Fukui
Yasuyuki Matsuura
Motohiko Sato
Hiroki Takada
Publikationsdatum
01.03.2015
Verlag
Springer Japan
Erschienen in
Environmental Health and Preventive Medicine / Ausgabe 2/2015
Print ISSN: 1342-078X
Elektronische ISSN: 1347-4715
DOI
https://doi.org/10.1007/s12199-014-0424-4

Weitere Artikel der Ausgabe 2/2015

Environmental Health and Preventive Medicine 2/2015 Zur Ausgabe

Letter to the Editor

Letter to the Editor