The incidence of intraoperative femoral fractures with a single design of stem implant, the Meridian (Stryker-Howmedica, Rutherford, N.J.), has been assessed in a study of 117 implants in patients treated consecutively between 1996 and 2001. The aim of the study was to evaluate the risk factors for suffering an intraoperative fracture and to determine, based on a short-term follow-up, if there were radiographic signs of early loosening. The following variables were analysed: demographic factors of the patient, morphology of the femur, intraoperative factors and postoperative radiographic factors. The radiographic stability of the implant and the presence of early signs of loosening were evaluated 2 years after surgery. The incidence of femoral fractures was 11% (13 cases in 117 implants), which is higher that reported in earlier published studies, and there was an increased number of fractures when the proximal filling of the femoral canal was higher. Although there was no statistically significant relation between the variables studied and the appearance of an intraoperative fracture, we conclude that the appearance of a femoral intraoperative fracture did not affect the radiographic stability of the implant during the short-term follow-up of our study cohort.
Literatur
1.
Zurück zum Zitat Andrew TA, Flanagan JP, Gerundini M, Bombelli R (1986) The isoelastic, noncemented hip arthroplasty: Preliminary experience with 400 cases. Clin Orthop 206:127–138PubMed Andrew TA, Flanagan JP, Gerundini M, Bombelli R (1986) The isoelastic, noncemented hip arthroplasty: Preliminary experience with 400 cases. Clin Orthop 206:127–138PubMed
2.
Zurück zum Zitat Berend KR, Lombardi AV Jr, Mallory TH, Chonko DJ, Dodds KL, Adams JB (2004) Cerclage wires or cables for the management of intraoperative fracture associated with a cementless tapered femoral prosthesis: results at 2 to 16 years. J Arthroplasty 19:17–21 Berend KR, Lombardi AV Jr, Mallory TH, Chonko DJ, Dodds KL, Adams JB (2004) Cerclage wires or cables for the management of intraoperative fracture associated with a cementless tapered femoral prosthesis: results at 2 to 16 years. J Arthroplasty 19:17–21
3.
4.
Zurück zum Zitat Capello WN, Sallay PI, Feinberg JR (1994) Omniflex modular femoral component: Two-to-five year results. Clin Orthop 298:54–59PubMed Capello WN, Sallay PI, Feinberg JR (1994) Omniflex modular femoral component: Two-to-five year results. Clin Orthop 298:54–59PubMed
5.
Zurück zum Zitat Elias JJ, Nagao M, Chu YH, Lennox DW, Chao EY (2000) Medial cortex strain distribution during noncemented total hip arthroplasty. Clin Orthop 370:250–258PubMedCrossRef Elias JJ, Nagao M, Chu YH, Lennox DW, Chao EY (2000) Medial cortex strain distribution during noncemented total hip arthroplasty. Clin Orthop 370:250–258PubMedCrossRef
6.
Zurück zum Zitat Engh CA, Bobyn JD (1988) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7–28PubMed Engh CA, Bobyn JD (1988) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7–28PubMed
7.
Zurück zum Zitat Engh CA, Glassman AH, Griffin WL, Mayer JG (1988) Results of cementless revision for failed cemented total hip arthroplasty. Clin Orthop 235:91–110PubMed Engh CA, Glassman AH, Griffin WL, Mayer JG (1988) Results of cementless revision for failed cemented total hip arthroplasty. Clin Orthop 235:91–110PubMed
8.
Zurück zum Zitat Falez F, Santori N, Panegrossi G (1998) Intraoperative type I proximal femoral fractures. Influence on the stability of hydroxyl apatite-coated femoral components. J Arthroplasty 13:653–659PubMedCrossRef Falez F, Santori N, Panegrossi G (1998) Intraoperative type I proximal femoral fractures. Influence on the stability of hydroxyl apatite-coated femoral components. J Arthroplasty 13:653–659PubMedCrossRef
9.
Zurück zum Zitat Fitzgerald RH, Brindley GW, Kavanagh BF (1988) The uncemented total hip arthroplasty: Intraoperative femoral fractures. Clin Orthop 235:61–66PubMed Fitzgerald RH, Brindley GW, Kavanagh BF (1988) The uncemented total hip arthroplasty: Intraoperative femoral fractures. Clin Orthop 235:61–66PubMed
10.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: Radiographic analysis of loosening. Clin Orthop 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: Radiographic analysis of loosening. Clin Orthop 141:17–27PubMed
11.
Zurück zum Zitat Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg (Am) 51:737–755 Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg (Am) 51:737–755
12.
Zurück zum Zitat Johansson JE, Mc Broom R, Barrington TW et al (1981) Fracture of the ipsilateral femur in patients with total hip replacement. J Bone Joint Surg (Am) 63A:1435–1442 Johansson JE, Mc Broom R, Barrington TW et al (1981) Fracture of the ipsilateral femur in patients with total hip replacement. J Bone Joint Surg (Am) 63A:1435–1442
13.
Zurück zum Zitat Lord G, Marotte J-H, Guillamon J-L, Blanchard J-P (1988) Cementless revisions of failed cemented and cementless total hip arthroplasties: 284 cases. Clin Orthop 235:67–74PubMed Lord G, Marotte J-H, Guillamon J-L, Blanchard J-P (1988) Cementless revisions of failed cemented and cementless total hip arthroplasties: 284 cases. Clin Orthop 235:67–74PubMed
14.
Zurück zum Zitat Mallory TH, Kraus TJ, Vaughn BK (1989) Intraoperative femoral fractures associated with cementless total hip arthroplasty. Orthopedics 12:231–239PubMed Mallory TH, Kraus TJ, Vaughn BK (1989) Intraoperative femoral fractures associated with cementless total hip arthroplasty. Orthopedics 12:231–239PubMed
15.
Zurück zum Zitat Martell JM, Pierson RH, Jacobs JJ et al (1993) Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg (Am) 75A:554–571 Martell JM, Pierson RH, Jacobs JJ et al (1993) Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg (Am) 75A:554–571
16.
Zurück zum Zitat Meek RM, Garbuz DS, Masri BA, Greidanus NV, Duncan CP (2004) Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J Bone Joint Surg (Am) 86-A:480–485 Meek RM, Garbuz DS, Masri BA, Greidanus NV, Duncan CP (2004) Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J Bone Joint Surg (Am) 86-A:480–485
17.
Zurück zum Zitat Mont MA, Maar DC, Krackow KA, Hungerford DS (1992) Hoop-stress fractures of the proximal femur during hip arthroplasty: Management and results in 19 cases. J Bone Joint Surg (Br) 74B:257–260 Mont MA, Maar DC, Krackow KA, Hungerford DS (1992) Hoop-stress fractures of the proximal femur during hip arthroplasty: Management and results in 19 cases. J Bone Joint Surg (Br) 74B:257–260
18.
Zurück zum Zitat Moroni A, Faldini C, Piras F, Giannini S (2000) Risk factors for intraoperative femoral fractures during total hip replacement. Ann Chirurg Gynaecol 89:113–118 Moroni A, Faldini C, Piras F, Giannini S (2000) Risk factors for intraoperative femoral fractures during total hip replacement. Ann Chirurg Gynaecol 89:113–118
19.
Zurück zum Zitat Paprosky WG, Greidanus NV, Antoniu J (1999) Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty. Clin Orthop 369:119–130 Paprosky WG, Greidanus NV, Antoniu J (1999) Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty. Clin Orthop 369:119–130
20.
Zurück zum Zitat Schwatrz JT Jr, Mayer JG, Engh CA (1989) Femoral fracture during non-cemented total hip arthroplasty. J Bone Joint Surg (Am) 71-A:1135–1142 Schwatrz JT Jr, Mayer JG, Engh CA (1989) Femoral fracture during non-cemented total hip arthroplasty. J Bone Joint Surg (Am) 71-A:1135–1142
21.
Zurück zum Zitat Scott RD, Turner RH, Leitzes SM, Aufranc OE (1975) Femoral fractures in conjunction with total hip replacement. J Bone Joint Surg (Am) 57-A:494–501 Scott RD, Turner RH, Leitzes SM, Aufranc OE (1975) Femoral fractures in conjunction with total hip replacement. J Bone Joint Surg (Am) 57-A:494–501
22.
Zurück zum Zitat Sharkey PF, Hozack WJ, Booth RE, Rothman RH (1992) Intraoperative femoral fractures in cementless total hip arthroplasty. Orthop Rev 21:337–342PubMed Sharkey PF, Hozack WJ, Booth RE, Rothman RH (1992) Intraoperative femoral fractures in cementless total hip arthroplasty. Orthop Rev 21:337–342PubMed
23.
Zurück zum Zitat Singh M, Nagrath AR, Maini PS (1970) Changes in the Trabecular Pattern of the Upper End of the Femur as an Index of Osteoporosis. J Bone Joint Surg (Am) 52-A:457–467 Singh M, Nagrath AR, Maini PS (1970) Changes in the Trabecular Pattern of the Upper End of the Femur as an Index of Osteoporosis. J Bone Joint Surg (Am) 52-A:457–467
24.
Zurück zum Zitat Taylor MM, Meyers MH, Harvey JP (1978) Intraoperative femur fractures during total hip replacement. Clin Orthop 137:96–103PubMed Taylor MM, Meyers MH, Harvey JP (1978) Intraoperative femur fractures during total hip replacement. Clin Orthop 137:96–103PubMed
25.
Zurück zum Zitat Toni A, Ciaroni D, Sudanese A, Femino F, Marraro MD, Bueno Lozano AL, Giunti A (1994) Incidence of intraoperative femoral fracture. Straight-stemmed versus anatomic cementless total hip arthroplasty. Acta Orthop Belg 60:43–54PubMed Toni A, Ciaroni D, Sudanese A, Femino F, Marraro MD, Bueno Lozano AL, Giunti A (1994) Incidence of intraoperative femoral fracture. Straight-stemmed versus anatomic cementless total hip arthroplasty. Acta Orthop Belg 60:43–54PubMed
Metadaten
Titel
Peroperative fractures in uncemented total hip arthrography: results with a single design of stem implant
verfasst von
Ricardo Fernandez-Fernandez
Elena García-Elias
Enrique Gil-Garay
Publikationsdatum
01.06.2008
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 3/2008
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0318-1

Weitere Artikel der Ausgabe 3/2008

International Orthopaedics 3/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.