Purpose

Pre-curved peek rods to support posterior lumbar fusion have been available in the market since 4 years. Potential advantages using this new technology are increased load sharing on the anterior column promoting interbody fusion, reduced stress on bone–screw interface decreasing the rate of screw mobilization and, in the long term, reduced incidence of adjacent level disc degeneration.

Methods

The authors retrospectively reviewed 30 cases in which posterior fusion was supported by peek rods, analyzing early complications, rate of fusion and clinical outcome.

Results

At an average follow-up of 18 months, both clinical and radiographic results were satisfactory with only one case requiring surgical revision for a mechanical complication.

Conclusions

The semi-rigid systems can now be considered a viable option in the lumbar degenerative disease, although clinical evaluations are necessary in the longer term.
Literatur
1.
Zurück zum Zitat Schwab FJ, Nazarian DG, Mahmud F et al (1995) Effects of spinal instrumentation on fusion of the lumbosacral spine. Spine 20:2023–2028PubMedCrossRef Schwab FJ, Nazarian DG, Mahmud F et al (1995) Effects of spinal instrumentation on fusion of the lumbosacral spine. Spine 20:2023–2028PubMedCrossRef
2.
Zurück zum Zitat Narayan P, Haid RW, Subach BR et al (2002) Effect of spinal disease on successful arthrodesis in lumbar pedicle screw fixation. J Neurosurg 97(3 Suppl):277–280PubMed Narayan P, Haid RW, Subach BR et al (2002) Effect of spinal disease on successful arthrodesis in lumbar pedicle screw fixation. J Neurosurg 97(3 Suppl):277–280PubMed
3.
Zurück zum Zitat Asher MA, Carson WL, Hardacker JW et al (2007) The effect of arthrodesis, implant stiffness, and time on the canine lumbar spine. J Spinal Disord Tech 20:549–559PubMedCrossRef Asher MA, Carson WL, Hardacker JW et al (2007) The effect of arthrodesis, implant stiffness, and time on the canine lumbar spine. J Spinal Disord Tech 20:549–559PubMedCrossRef
4.
5.
Zurück zum Zitat Thomsen K, Christensen FB, Eiskjaer SP et al (1997) 1997 Volvo Award winner in clinical studies. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: a prospective, randomized clinical study. Spine 22:2813–2822PubMedCrossRef Thomsen K, Christensen FB, Eiskjaer SP et al (1997) 1997 Volvo Award winner in clinical studies. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: a prospective, randomized clinical study. Spine 22:2813–2822PubMedCrossRef
6.
Zurück zum Zitat Wedemeyer M, Parent S, Mahar A et al (2007) Titanium versus stainless steel for anterior spinal fusions: an analysis of rod stress as a predictor of rod breakage during physiologic loading in a bovine model. Spine 32:42–48PubMedCrossRef Wedemeyer M, Parent S, Mahar A et al (2007) Titanium versus stainless steel for anterior spinal fusions: an analysis of rod stress as a predictor of rod breakage during physiologic loading in a bovine model. Spine 32:42–48PubMedCrossRef
7.
Zurück zum Zitat Toth JM, Wang M, Estes BT et al (2006) Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 27:324–334PubMedCrossRef Toth JM, Wang M, Estes BT et al (2006) Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 27:324–334PubMedCrossRef
8.
Zurück zum Zitat Kurtz SM, Devine JN (2007) PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28:4845–4869PubMedCrossRef Kurtz SM, Devine JN (2007) PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28:4845–4869PubMedCrossRef
9.
Zurück zum Zitat Ponnappan RK, Serhan H, Zarda B, Patel R, Albert T, Vaccaro AR (2009) Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation. Spine J 9(3):263–267PubMedCrossRef Ponnappan RK, Serhan H, Zarda B, Patel R, Albert T, Vaccaro AR (2009) Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation. Spine J 9(3):263–267PubMedCrossRef
10.
Zurück zum Zitat Galbusera F, Bellini CM, Anasetti F, Ciavarro C, Lovi A, Brayda-Bruno M (2011) Rigid and flexible spinal stabilization devices: a biomechanical comparison. Med Eng Phys 33(4):490–496PubMedCrossRef Galbusera F, Bellini CM, Anasetti F, Ciavarro C, Lovi A, Brayda-Bruno M (2011) Rigid and flexible spinal stabilization devices: a biomechanical comparison. Med Eng Phys 33(4):490–496PubMedCrossRef
11.
Zurück zum Zitat Wenz LM, Merritt K, Brown SA, Moet A, Steffee AD (1990) In vitro biocompatibility of polyetheretherketone and polysulfone composites. J Biomed Mater Res 24:207–215PubMedCrossRef Wenz LM, Merritt K, Brown SA, Moet A, Steffee AD (1990) In vitro biocompatibility of polyetheretherketone and polysulfone composites. J Biomed Mater Res 24:207–215PubMedCrossRef
Metadaten
Titel
Posterior lumbar fusion by peek rods in degenerative spine: preliminary report on 30 cases
verfasst von
F. De Iure
G. Bosco
M. Cappuccio
S. Paderni
L. Amendola
Publikationsdatum
01.05.2012
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe Sonderheft 1/2012
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-012-2219-x

Weitere Artikel der Sonderheft 1/2012

European Spine Journal 1/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.