01.01.2013 | Original Article

Precise ablation of dental hard tissues with ultra-short pulsed lasers. Preliminary exploratory investigation on adequate laser parameters

verfasst von: Marina Stella Bello-Silva, Martin Wehner, Carlos de Paula Eduardo, Friedrich Lampert, Reinhart Poprawe, Martin Hermans, Marcella Esteves-Oliveira

Erschienen in: Lasers in Medical Science | Ausgabe 1/2013

Einloggen, um Zugang zu erhalten

Abstract

This study aimed to evaluate the possibility of introducing ultra-short pulsed lasers (USPL) in restorative dentistry by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages, such as thermal damage of irradiated substrate. USPL ablation of dental hard tissues was investigated in two phases. Phase 1—different wavelengths (355, 532, 1,045, and 1,064 nm), pulse durations (picoseconds and femtoseconds) and irradiation parameters (scanning speed, output power, and pulse repetition rate) were assessed for enamel and dentin. Ablation rate was determined, and the temperature increase measured in real time. Phase 2—the most favorable laser parameters were evaluated to correlate temperature increase to ablation rate and ablation efficiency. The influence of cooling methods (air, air–water spray) on ablation process was further analyzed. All parameters tested provided precise and selective tissue ablation. For all lasers, faster scanning speeds resulted in better interaction and reduced temperature increase. The most adequate results were observed for the 1064-nm ps-laser and the 1045-nm fs-laser. Forced cooling caused moderate changes in temperature increase, but reduced ablation, being considered unnecessary during irradiation with USPL. For dentin, the correlation between temperature increase and ablation efficiency was satisfactory for both pulse durations, while for enamel, the best correlation was observed for fs-laser, independently of the power used. USPL may be suitable for cavity preparation in dentin and enamel, since effective ablation and low temperature increase were observed. If adequate laser parameters are selected, this technique seems to be promising for promoting the laser-assisted, minimally invasive approach.
Literatur
1.
Zurück zum Zitat Peters MC, McLean ME (2001) Minimally invasive operative care. II. Contemporary techniques and materials: an overview. J Adhes Dent 3(1):17–31PubMed Peters MC, McLean ME (2001) Minimally invasive operative care. II. Contemporary techniques and materials: an overview. J Adhes Dent 3(1):17–31PubMed
2.
Zurück zum Zitat Setien VJ, Cobb DS, Denehy GE, Vargas MA (2001) Cavity preparation devices: effect on microleakage of class V resin-based composite restorations. Am J Dent 14(3):157–162PubMed Setien VJ, Cobb DS, Denehy GE, Vargas MA (2001) Cavity preparation devices: effect on microleakage of class V resin-based composite restorations. Am J Dent 14(3):157–162PubMed
3.
Zurück zum Zitat Cozean C, Arcoria CJ, Pelagalli J, Powell GL (1997) Dentistry for the 21st century? Erbium:YAG laser for teeth. J Am Dent Assoc 128(8):1080–1087PubMed Cozean C, Arcoria CJ, Pelagalli J, Powell GL (1997) Dentistry for the 21st century? Erbium:YAG laser for teeth. J Am Dent Assoc 128(8):1080–1087PubMed
4.
Zurück zum Zitat Keller U, Hibst R, Geurtsen W, Schilke R, Heidemann D, Klaiber B, Raab WH (1998) Erbium:YAG laser application in caries therapy. Evaluation of patient perception and acceptance. J Dent 26(8):649–656PubMedCrossRef Keller U, Hibst R, Geurtsen W, Schilke R, Heidemann D, Klaiber B, Raab WH (1998) Erbium:YAG laser application in caries therapy. Evaluation of patient perception and acceptance. J Dent 26(8):649–656PubMedCrossRef
5.
Zurück zum Zitat Keller U, Hibst R (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances: II. Light microscopic and SEM investigations. Lasers Surg Med 9(4):345–351PubMedCrossRef Keller U, Hibst R (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances: II. Light microscopic and SEM investigations. Lasers Surg Med 9(4):345–351PubMedCrossRef
6.
Zurück zum Zitat Dostalova T, Jelinkova H, Kucerova H (1998) Er:YAG laser ablation-evaluation after two-years long clinical treatment. Proc SPIE 3248:23–32CrossRef Dostalova T, Jelinkova H, Kucerova H (1998) Er:YAG laser ablation-evaluation after two-years long clinical treatment. Proc SPIE 3248:23–32CrossRef
7.
Zurück zum Zitat Gouw-Soares S, Gutknecht N, Conrads G, Lampert F, Matson E, Eduardo CP (2000) The bactericidal effect of Ho:YAG laser irradiation within contaminated root dentinal samples. J Clin Laser Med Surg 18(2):81–87PubMed Gouw-Soares S, Gutknecht N, Conrads G, Lampert F, Matson E, Eduardo CP (2000) The bactericidal effect of Ho:YAG laser irradiation within contaminated root dentinal samples. J Clin Laser Med Surg 18(2):81–87PubMed
8.
Zurück zum Zitat Tyas MJ, Anusavice KJ, Frencken JE, Mount GJ (2000) Minimal intervention dentistry—a review. FDI Commission Project 1–97. Int Dent J 50(1):1–12PubMedCrossRef Tyas MJ, Anusavice KJ, Frencken JE, Mount GJ (2000) Minimal intervention dentistry—a review. FDI Commission Project 1–97. Int Dent J 50(1):1–12PubMedCrossRef
9.
Zurück zum Zitat Rode AV, Gamaly EG, Luther-Davies B, Taylor BT, Graessel M, Dawes JM, Chan A, Lowe RM, Hannaford P (2003) Precision ablation of dental enamel using a subpicosecond pulsed laser. Aust Dent J 48(4):233–239PubMedCrossRef Rode AV, Gamaly EG, Luther-Davies B, Taylor BT, Graessel M, Dawes JM, Chan A, Lowe RM, Hannaford P (2003) Precision ablation of dental enamel using a subpicosecond pulsed laser. Aust Dent J 48(4):233–239PubMedCrossRef
10.
Zurück zum Zitat Chan A, Rode A, Gamaly E, Luther-Davies B, Taylor B, Dawes J, Lowe M, Hannaford P (2003) Ablation of dental enamel using subpicosecond pulsed lasers. Int Congr Ser 1248:117–119CrossRef Chan A, Rode A, Gamaly E, Luther-Davies B, Taylor B, Dawes J, Lowe M, Hannaford P (2003) Ablation of dental enamel using subpicosecond pulsed lasers. Int Congr Ser 1248:117–119CrossRef
11.
Zurück zum Zitat Fahey M, Onyejekwe O, Mason HL, Mitra K (2008) Precise dental ablation using ultra-short-pulsed 1552 nm laser. Int J Heat Mass Transf 51:5732–5739CrossRef Fahey M, Onyejekwe O, Mason HL, Mitra K (2008) Precise dental ablation using ultra-short-pulsed 1552 nm laser. Int J Heat Mass Transf 51:5732–5739CrossRef
12.
Zurück zum Zitat Sheth KK, Staninec M, Sarma AV, Fried D (2004) Selective targeting of protein, water, and mineral in dentin using UV and IR pulse lasers: the effect on the bond strength to composite restorative materials. Lasers Surg Med 35(4):245–253PubMedCrossRef Sheth KK, Staninec M, Sarma AV, Fried D (2004) Selective targeting of protein, water, and mineral in dentin using UV and IR pulse lasers: the effect on the bond strength to composite restorative materials. Lasers Surg Med 35(4):245–253PubMedCrossRef
13.
Zurück zum Zitat Wheeler CR, Fried D, Featherstone JD, Watanabe LG, Le CQ (2003) Irradiation of dental enamel with Q-switched lambda = 355-nm laser pulses: surface morphology, fluoride adsorption, and adhesion to composite resin. Lasers Surg Med 32(4):310–317PubMedCrossRef Wheeler CR, Fried D, Featherstone JD, Watanabe LG, Le CQ (2003) Irradiation of dental enamel with Q-switched lambda = 355-nm laser pulses: surface morphology, fluoride adsorption, and adhesion to composite resin. Lasers Surg Med 32(4):310–317PubMedCrossRef
14.
Zurück zum Zitat van Gemert MJ, Welch AJ (1989) Time constants in thermal laser medicine. Lasers Surg Med 9(4):405–421PubMedCrossRef van Gemert MJ, Welch AJ (1989) Time constants in thermal laser medicine. Lasers Surg Med 9(4):405–421PubMedCrossRef
15.
Zurück zum Zitat Dela Rosa A, Sarma AV, Le CQ, Jones RS, Fried D (2004) Peripheral thermal and mechanical damage to dentin with microsecond and sub-microsecond 9.6 microm, 2.79 microm, and 0.355 microm laser pulses. Lasers Surg Med 35(3):214–228CrossRef Dela Rosa A, Sarma AV, Le CQ, Jones RS, Fried D (2004) Peripheral thermal and mechanical damage to dentin with microsecond and sub-microsecond 9.6 microm, 2.79 microm, and 0.355 microm laser pulses. Lasers Surg Med 35(3):214–228CrossRef
16.
Zurück zum Zitat Niemz MH (1998) Ultrashort laser pulses in dentistry, advantages and limitations. SPIE 3255:84–91CrossRef Niemz MH (1998) Ultrashort laser pulses in dentistry, advantages and limitations. SPIE 3255:84–91CrossRef
17.
Zurück zum Zitat Kurtz RM, Elner V, Liu X, Juhasz T (1997) Plasma-mediated ablation of biological tissue with picosecond and femtosecond laser pulses. SPIE 2975:192–200CrossRef Kurtz RM, Elner V, Liu X, Juhasz T (1997) Plasma-mediated ablation of biological tissue with picosecond and femtosecond laser pulses. SPIE 2975:192–200CrossRef
18.
Zurück zum Zitat Perry MD, Stuart BC, Banks PS, Feit MD, Yanovsky V, Rubenchik AM (1999) Ultrashort-pulse laser machining of dielectric materials. J Appl Phys 9(85):6803–6810CrossRef Perry MD, Stuart BC, Banks PS, Feit MD, Yanovsky V, Rubenchik AM (1999) Ultrashort-pulse laser machining of dielectric materials. J Appl Phys 9(85):6803–6810CrossRef
19.
Zurück zum Zitat Lizarelli RF, Kurachi C, Misoguti L, Bagnato VS (2000) A comparative study of nanosecond and picosecond laser ablation in enamel: morphological aspects. J Clin Laser Med Surg 18(3):151–157PubMed Lizarelli RF, Kurachi C, Misoguti L, Bagnato VS (2000) A comparative study of nanosecond and picosecond laser ablation in enamel: morphological aspects. J Clin Laser Med Surg 18(3):151–157PubMed
20.
Zurück zum Zitat Niemz M (1996) Laser tissue interactions: fundamentals and applications. Springer, Berlin Niemz M (1996) Laser tissue interactions: fundamentals and applications. Springer, Berlin
21.
Zurück zum Zitat Lizarelli RF, Moriyama LT, Bagnato VS (2006) Temperature response in the pulpal chamber of primary human teeth exposed to Nd:YAG laser using a picosecond pulsed regime. Photomed Laser Surg 24(5):610–615PubMedCrossRef Lizarelli RF, Moriyama LT, Bagnato VS (2006) Temperature response in the pulpal chamber of primary human teeth exposed to Nd:YAG laser using a picosecond pulsed regime. Photomed Laser Surg 24(5):610–615PubMedCrossRef
22.
Zurück zum Zitat de Lizarelli FZR, Moriyama LT, Bagnato VS (2002) Ablation rate and micromorphological aspects with Nd:YAG picosecond pulsed laser on primary teeth. Lasers Surg Med 31(3):177–185CrossRef de Lizarelli FZR, Moriyama LT, Bagnato VS (2002) Ablation rate and micromorphological aspects with Nd:YAG picosecond pulsed laser on primary teeth. Lasers Surg Med 31(3):177–185CrossRef
23.
Zurück zum Zitat Zach L, Cohen G (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 19:515–530PubMedCrossRef Zach L, Cohen G (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 19:515–530PubMedCrossRef
24.
Zurück zum Zitat Ceballo L, Toledano M, Osorio R, Tay FR, Marshall GW (2002) Bonding to Er-YAG-laser-treated dentin. J Dent Res 81(2):119–122PubMedCrossRef Ceballo L, Toledano M, Osorio R, Tay FR, Marshall GW (2002) Bonding to Er-YAG-laser-treated dentin. J Dent Res 81(2):119–122PubMedCrossRef
25.
Zurück zum Zitat Uhrig G, Meyer D, Foth HJ (2001) Transient FEM calculation of the spatial heat distribution in hard dental tissue during and after IR laser ablation. Proc SPIE 4249:61–71CrossRef Uhrig G, Meyer D, Foth HJ (2001) Transient FEM calculation of the spatial heat distribution in hard dental tissue during and after IR laser ablation. Proc SPIE 4249:61–71CrossRef
26.
Zurück zum Zitat Braun A, Wehry RJ, Brede O, Dehn C, Frentzen M, Schelle F (2012) Heat generation caused by ablation of restorative materials with an ultrashort pulse laser (USPL) system. Lasers Med Sci. 27(2):297–303 Braun A, Wehry RJ, Brede O, Dehn C, Frentzen M, Schelle F (2012) Heat generation caused by ablation of restorative materials with an ultrashort pulse laser (USPL) system. Lasers Med Sci. 27(2):297–303
27.
Zurück zum Zitat Visuri SR, Walsh JT Jr, Wigdor HA (1996) Erbium laser ablation of dental hard tissue: effect of water cooling. Lasers Surg Med 18(3):294–300PubMedCrossRef Visuri SR, Walsh JT Jr, Wigdor HA (1996) Erbium laser ablation of dental hard tissue: effect of water cooling. Lasers Surg Med 18(3):294–300PubMedCrossRef
28.
Zurück zum Zitat Meister J, Franzen R, Forner K, Grebe H, Stanzel S, Lampert F, Apel C (2006) Influence of the water content in dental enamel and dentin on ablation with erbium YAG and erbium YSGG lasers. J Biomed Opt 11(3):34030PubMedCrossRef Meister J, Franzen R, Forner K, Grebe H, Stanzel S, Lampert F, Apel C (2006) Influence of the water content in dental enamel and dentin on ablation with erbium YAG and erbium YSGG lasers. J Biomed Opt 11(3):34030PubMedCrossRef
29.
Zurück zum Zitat Staninec M, Xie J, Le CQ, Fried D (2003) Influence of an optically thick water layer on the bond-strength of composite resin to dental enamel after IR laser ablation. Lasers Surg Med 33(4):264–269PubMedCrossRef Staninec M, Xie J, Le CQ, Fried D (2003) Influence of an optically thick water layer on the bond-strength of composite resin to dental enamel after IR laser ablation. Lasers Surg Med 33(4):264–269PubMedCrossRef
30.
Zurück zum Zitat Fried D, Ashouri N, Breunig T, Shori R (2002) Mechanism of water augmentation during IR laser ablation of dental enamel. Lasers Surg Med 31(3):186–193PubMedCrossRef Fried D, Ashouri N, Breunig T, Shori R (2002) Mechanism of water augmentation during IR laser ablation of dental enamel. Lasers Surg Med 31(3):186–193PubMedCrossRef
31.
Zurück zum Zitat Hibst R, Keller U (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate. Lasers Surg Med 9(4):338–344PubMedCrossRef Hibst R, Keller U (1989) Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate. Lasers Surg Med 9(4):338–344PubMedCrossRef
32.
Zurück zum Zitat Altshuler GB, Belikov AV, Sinelnik YA (2001) A laser-abrasive method for the cutting of enamel and dentin. Lasers Surg Med 28(5):435–444PubMedCrossRef Altshuler GB, Belikov AV, Sinelnik YA (2001) A laser-abrasive method for the cutting of enamel and dentin. Lasers Surg Med 28(5):435–444PubMedCrossRef
33.
Zurück zum Zitat Bader C, Krejci I (2006) Indications and limitations of Er:YAG laser applications in dentistry. Am J Dent 19(3):178–186PubMed Bader C, Krejci I (2006) Indications and limitations of Er:YAG laser applications in dentistry. Am J Dent 19(3):178–186PubMed
34.
Zurück zum Zitat Kim BM, Eichler J, Da Silva LB (1999) Frequency doubling of ultrashort laser pulses in biological tissues. Appl Opt 38(34):7145–7150PubMedCrossRef Kim BM, Eichler J, Da Silva LB (1999) Frequency doubling of ultrashort laser pulses in biological tissues. Appl Opt 38(34):7145–7150PubMedCrossRef
35.
Zurück zum Zitat Mehl A, Kremers L, Salzmann K, Hickel R (1997) 3D volume-ablation rate and thermal side effects with the Er:YAG and Nd:YAG laser. Dent Mater 13(4):246–251PubMedCrossRef Mehl A, Kremers L, Salzmann K, Hickel R (1997) 3D volume-ablation rate and thermal side effects with the Er:YAG and Nd:YAG laser. Dent Mater 13(4):246–251PubMedCrossRef
36.
Zurück zum Zitat Hossain M, Nakamura Y, Yamada Y, Kimura Y, Nakamura G, Matsumoto K (1999) Ablation depths and morphological changes in human enamel and dentin after Er:YAG laser irradiation with or without water mist. J Clin Laser Med Surg 17(3):105–109PubMed Hossain M, Nakamura Y, Yamada Y, Kimura Y, Nakamura G, Matsumoto K (1999) Ablation depths and morphological changes in human enamel and dentin after Er:YAG laser irradiation with or without water mist. J Clin Laser Med Surg 17(3):105–109PubMed
37.
Zurück zum Zitat Kim BM, Feit MD, Rubenchik AM, Joslin EJ, Celliers PM, Eichler J, Da Silva LB (2001) Influence of pulse duration on ultrashort laser pulse ablation of biological tissues. J Biomed Opt 6(3):332–338PubMedCrossRef Kim BM, Feit MD, Rubenchik AM, Joslin EJ, Celliers PM, Eichler J, Da Silva LB (2001) Influence of pulse duration on ultrashort laser pulse ablation of biological tissues. J Biomed Opt 6(3):332–338PubMedCrossRef
Metadaten
Titel
Precise ablation of dental hard tissues with ultra-short pulsed lasers. Preliminary exploratory investigation on adequate laser parameters
verfasst von
Marina Stella Bello-Silva
Martin Wehner
Carlos de Paula Eduardo
Friedrich Lampert
Reinhart Poprawe
Martin Hermans
Marcella Esteves-Oliveira
Publikationsdatum
01.01.2013
Verlag
Springer-Verlag
Erschienen in
Lasers in Medical Science / Ausgabe 1/2013
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-012-1107-2

Weitere Artikel der Ausgabe 1/2013

Lasers in Medical Science 1/2013 Zur Ausgabe