Background

Before launching a new bespoke foot orthotic (FO) product, it is necessary to understand how it works under compressive loads. Additive manufacturing and the selective laser sintering process in particular can enable a number of innovative and functional features to be integrated to the FO device. A simple example of this design freedom is to adjust the shell thickness of an FO. This research is an effort to measure the displacement of the arch as the FO is loaded with a certain force and how much different FO shell thicknesses impact the amount of displacement with the same load.

Methods

The FO’s tested were designed as bespoke FO's for a patient. They were identical apart from their thickness which varied from 1 to 3.5mm in 0.5mm intervals. The test was set up as follows:
  • The FO was clamped onto the Instron 4505 test machine at the heel with the aid of the sand bag to spread the clamping load. The FO was also clamped on the 5th metatarsal.
  • The instrument head pressing on the part was placed on the estimated position of the navicular bone.
  • The testing start point varied between tests as it was determined by eye. This means that the displacement of the machine test head before contact with the orthosis will vary slightly between tests.
  • A maximum load of 400N was applied at the rate of 100mm/min.
Each orthosis compressed 3 successive times in order to determine any changes in behaviour. This process was repeated for all six orthoses. The same experiment was the set up again to simulate the test being repeated in a different laboratory.

Results

The line versus displacement curves for the orthoses generally follow the same kind of pattern in terms of their behaviour and the variation between subsequent tests. The load required to flatten the orthosis (approximately 20mm) can give an indication of the flexibility. The thinnest orthosis (and hence most flexible) took approximately 16N to reach the ground whereas the thickest (and hence most rigid) book approximately 395N to reach the ground. Generally as an orthosis is subjected to more testing, the load required to produce a certain displacement decreased. The results will be presented in full in the presentation.

Conclusions

As expected, as the thickness of the orthosis increased, the load applied to cause the same displacement also increased. The pattern of the load vs displacement changed from a complex pattern in load to a more linear and predictable increase as the thickness of the FO increased. This work can be seen as the initial step in engineering a foot orthotic and in quantifying its properties. Future work would include creating a finite element model that can be verified with physical measurements and using this model to optimise the response of the FO in certain loading conditions, or to reduce the mass and size of the FO.
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​4.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Metadaten
Titel
Quantifying the properties of selective laser sintered nylon foot orthoses under linear loading
verfasst von
Jari Pallari
Harriet Slack
Alastair Masson
Greg Jackson
Javier Munguia
Kenny Dalgarno
Publikationsdatum
01.12.2014
Verlag
BioMed Central
Erschienen in
Journal of Foot and Ankle Research / Ausgabe Sonderheft 2/2014
Elektronische ISSN: 1757-1146
DOI
https://doi.org/10.1186/1757-1146-7-S2-A7

Weitere Artikel der Sonderheft 2/2014

Journal of Foot and Ankle Research 2/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.