Abstract

Purpose

The primary objective of this paper was to provide a systematic review of the available clinical studies of Ti/PEEK combined cages in spinal interbody fusion surgeries, focusing on their radiological and clinical outcomes. A secondary aim was to provide a review and evaluation of the in vitro and preclinical studies reported on Ti/PEEK-coated implants.

Methods

A systematic search of the literature was performed in March 2015 via three databases: Medline, Embase and Cochrane library. The following key search terms were combined with synonyms to identify relevant articles: “spinal fusion,” “PEEK,” “titanium” and “cage.”

Results

The novelty of this intervention translates into a paucity of clinical trials, albeit the results of the seven clinical studies that met the criteria for inclusion are promising. All studies reported rate of fusion as a primary outcome. Two studies reported slightly improved fusion in the experimental Ti/PEEK combination cohort, one study identical fusion (91.7 %) and three studies excellent fusion (96, 100 and 94 %) in the Ti/PEEK cohort, although no differences reached statistical significance.

Conclusions

Clinical studies at this early stage demonstrate that Ti/PEEK implants are safe and efficacious, exhibiting similar fusion rates and clinical outcomes compared to the current standard PEEK. There is clinical evidence substantiating the improved radiographic fusion of Ti/PEEK, albeit the differences were not significant. This field is promising, gaining substantial popularity, and further clinical trials are needed in the future to establish Ti/PEEK cages as a mainstay of clinical practice.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Tsantrizos A, Andreou A, Aebi M, Steffen T (2000) Biomechanical stability of five stand-alone anterior lumbar interbody fusion constructs. Eur Spine J 9(1):14–22CrossRefPubMedPubMedCentral Tsantrizos A, Andreou A, Aebi M, Steffen T (2000) Biomechanical stability of five stand-alone anterior lumbar interbody fusion constructs. Eur Spine J 9(1):14–22CrossRefPubMedPubMedCentral
2.
3.
Zurück zum Zitat Mobbs RJ, Loganathan A, Yeung V, Rao PJ (2013) Indications for anterior lumbar interbody fusion. Orthop Surg 5(3):153–163CrossRefPubMed Mobbs RJ, Loganathan A, Yeung V, Rao PJ (2013) Indications for anterior lumbar interbody fusion. Orthop Surg 5(3):153–163CrossRefPubMed
4.
Zurück zum Zitat Mobbs RJ, Chung M, Rao PJ (2013) Bone graft substitutes for anterior lumbar interbody fusion. Orthop Surg 5(2):77–85CrossRefPubMed Mobbs RJ, Chung M, Rao PJ (2013) Bone graft substitutes for anterior lumbar interbody fusion. Orthop Surg 5(2):77–85CrossRefPubMed
5.
Zurück zum Zitat Park Y, Ha JW, Lee YT, Sung NY (2011) The effect of a radiographic solid fusion on clinical outcomes after minimally invasive transforaminal lumbar interbody fusion. Spine J 11(3):205–212CrossRefPubMed Park Y, Ha JW, Lee YT, Sung NY (2011) The effect of a radiographic solid fusion on clinical outcomes after minimally invasive transforaminal lumbar interbody fusion. Spine J 11(3):205–212CrossRefPubMed
6.
Zurück zum Zitat Martin CR, Gruszczynski AT, Braunsfurth HA, Fallatah SM, O’Neil J, Wai EK (2007) The surgical management of degenerative lumbar spondylolisthesis: a systematic review. Spine 32(16):1791–1798CrossRefPubMed Martin CR, Gruszczynski AT, Braunsfurth HA, Fallatah SM, O’Neil J, Wai EK (2007) The surgical management of degenerative lumbar spondylolisthesis: a systematic review. Spine 32(16):1791–1798CrossRefPubMed
7.
Zurück zum Zitat Rao PJ, Pelletier MH, Walsh WR, Mobbs RJ (2014) Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration. Orthop Surg 6(2):81–89CrossRefPubMed Rao PJ, Pelletier MH, Walsh WR, Mobbs RJ (2014) Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration. Orthop Surg 6(2):81–89CrossRefPubMed
8.
Zurück zum Zitat Lam FC, Alkalay R, Groff MW (2012) The effects of design and positioning of carbon fiber lumbar interbody cages and their subsidence in vertebral bodies. J Spinal Disord Tech 25(2):116–122CrossRefPubMed Lam FC, Alkalay R, Groff MW (2012) The effects of design and positioning of carbon fiber lumbar interbody cages and their subsidence in vertebral bodies. J Spinal Disord Tech 25(2):116–122CrossRefPubMed
9.
Zurück zum Zitat Choi JY, Sung KH (2006) Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages. Eur Spine J 15(1):16–22CrossRefPubMed Choi JY, Sung KH (2006) Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages. Eur Spine J 15(1):16–22CrossRefPubMed
10.
Zurück zum Zitat Mobbs RJ, Chong E, and Rao P (2014) Bioactive Ti/PEEK interbody cage for ACDF: early results. In: Neurosurgical Society of Australasia Annual Scientific Meeting 2014, Perth, Australia Mobbs RJ, Chong E, and Rao P (2014) Bioactive Ti/PEEK interbody cage for ACDF: early results. In: Neurosurgical Society of Australasia Annual Scientific Meeting 2014, Perth, Australia
11.
Zurück zum Zitat Sagomonyants KB, Jarman-Smith ML, Devine JN, Aronow MS, Gronowicz GA (2008) The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium. Biomaterials 29(11):1563–1572CrossRefPubMed Sagomonyants KB, Jarman-Smith ML, Devine JN, Aronow MS, Gronowicz GA (2008) The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium. Biomaterials 29(11):1563–1572CrossRefPubMed
13.
Zurück zum Zitat Walsh WR, Bertollo N, Christou C, Schaffner D, Mobbs RJ (2015) Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface. Spine J 15(5):1041–1049CrossRefPubMed Walsh WR, Bertollo N, Christou C, Schaffner D, Mobbs RJ (2015) Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface. Spine J 15(5):1041–1049CrossRefPubMed
14.
Zurück zum Zitat Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP et al (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 6(7):e1000100CrossRefPubMedPubMedCentral Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP et al (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 6(7):e1000100CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Harris JD, Quatman CE, Manring MM, Siston RA, Flanigan DC (2014) How to write a systematic review. Am J Sports Med 42(11):2761–2768CrossRefPubMed Harris JD, Quatman CE, Manring MM, Siston RA, Flanigan DC (2014) How to write a systematic review. Am J Sports Med 42(11):2761–2768CrossRefPubMed
16.
Zurück zum Zitat Kotsias A, Mularski S, Cabraja M, Kombos T, Süss O (2013) Fusion characteristics in ACDF with partially titanium coated PEEK cages. Eur Spine J 22(11):2582–2669CrossRef Kotsias A, Mularski S, Cabraja M, Kombos T, Süss O (2013) Fusion characteristics in ACDF with partially titanium coated PEEK cages. Eur Spine J 22(11):2582–2669CrossRef
17.
Zurück zum Zitat Schmitz A, Hoffmeister R, Reimann K, Ertel W (2011) First results of a cervical titanium-coated polyetheretherketone (PEEK)—disc prosthesis. Eur Spine J 20(11):1979–2066CrossRef Schmitz A, Hoffmeister R, Reimann K, Ertel W (2011) First results of a cervical titanium-coated polyetheretherketone (PEEK)—disc prosthesis. Eur Spine J 20(11):1979–2066CrossRef
18.
Zurück zum Zitat Rickert M, Schreiner S, Rauschmann M (2014) Randomized evaluation of bone ingrowth after intervertebral body fusion with a PEEK and a Titanium coated PEEK TLIF oblique cage. Radiological outcome after 12 months. Eur Spine J 23(11):2473–2569CrossRef Rickert M, Schreiner S, Rauschmann M (2014) Randomized evaluation of bone ingrowth after intervertebral body fusion with a PEEK and a Titanium coated PEEK TLIF oblique cage. Radiological outcome after 12 months. Eur Spine J 23(11):2473–2569CrossRef
19.
Zurück zum Zitat Süss O, Kühn B, Mularski S (2014) Fusion characteristics in ACDF with titanium-coated carbon fiber enhanced polyetheretherketone cages (tcCF/PEEK). Eur Spine J 23(11):2473–2569CrossRef Süss O, Kühn B, Mularski S (2014) Fusion characteristics in ACDF with titanium-coated carbon fiber enhanced polyetheretherketone cages (tcCF/PEEK). Eur Spine J 23(11):2473–2569CrossRef
20.
Zurück zum Zitat Külling F, Krebs J, Aebli N, Forster T (2013) Radiologic and clinical outcome of TLIF using CF/PEEK cages coated with titanium. Neuroradiology 55:779–800CrossRef Külling F, Krebs J, Aebli N, Forster T (2013) Radiologic and clinical outcome of TLIF using CF/PEEK cages coated with titanium. Neuroradiology 55:779–800CrossRef
21.
Zurück zum Zitat Schnake K, Weil S, Langheinrich A, Hoffmann CH, Pingel A, Scholz M et al (2013) Randomised clinical and radiological trial comparing PEEK with titanium-coated PEEK-cages for PLIF surgery. Eur Spine J 22(11):2582–2669CrossRef Schnake K, Weil S, Langheinrich A, Hoffmann CH, Pingel A, Scholz M et al (2013) Randomised clinical and radiological trial comparing PEEK with titanium-coated PEEK-cages for PLIF surgery. Eur Spine J 22(11):2582–2669CrossRef
22.
Zurück zum Zitat Benneker LM, Aksekili M, Seidel U, Haefeli P, Keel M (2014) 2 years experiences with a new Titanium coated radiolucent TLIF cage. Eur Spine J 23(11):2473–2569CrossRef Benneker LM, Aksekili M, Seidel U, Haefeli P, Keel M (2014) 2 years experiences with a new Titanium coated radiolucent TLIF cage. Eur Spine J 23(11):2473–2569CrossRef
23.
Zurück zum Zitat Fujibayashi S, Takemoto M, Neo M, Matsushita T, Kokubo T, Doi K et al (2011) A novel synthetic material for spinal fusion: a prospective clinical trial of porous bioactive titanium metal for lumbar interbody fusion. Eur Spine J 20(9):1486–1495CrossRefPubMedPubMedCentral Fujibayashi S, Takemoto M, Neo M, Matsushita T, Kokubo T, Doi K et al (2011) A novel synthetic material for spinal fusion: a prospective clinical trial of porous bioactive titanium metal for lumbar interbody fusion. Eur Spine J 20(9):1486–1495CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Diedrich O, Perlick L, Schmitt O, Kraft CN (2001) Radiographic characteristics on conventional radiographs after posterior lumbar interbody fusion: comparative study between radiotranslucent and radiopaque cages. J Spinal Disord 14(6):522–532CrossRefPubMed Diedrich O, Perlick L, Schmitt O, Kraft CN (2001) Radiographic characteristics on conventional radiographs after posterior lumbar interbody fusion: comparative study between radiotranslucent and radiopaque cages. J Spinal Disord 14(6):522–532CrossRefPubMed
26.
Zurück zum Zitat Han CM, Lee EJ, Kim HE, Koh YH, Kim KN, Ha Y et al (2010) The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties. Biomaterials 31(13):3465–3470CrossRefPubMed Han CM, Lee EJ, Kim HE, Koh YH, Kim KN, Ha Y et al (2010) The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties. Biomaterials 31(13):3465–3470CrossRefPubMed
27.
Zurück zum Zitat Wu X, Liu X, Wei J, Ma J, Deng F, Wei S (2012) Nano-TiO2/PEEK bioactive composite as a bone substitute material: in vitro and in vivo studies. Int J Nanomed 7:1215–1225 Wu X, Liu X, Wei J, Ma J, Deng F, Wei S (2012) Nano-TiO2/PEEK bioactive composite as a bone substitute material: in vitro and in vivo studies. Int J Nanomed 7:1215–1225
28.
Zurück zum Zitat Schaffarczyk D, Lauweryns P, Willems K (2014) Functionalized PEEK surface for biomimetic spine-fusion-implants: comparison of BIC and BV/TV values of titanium coated and un-coated PEEK implants in an animal model. Eur Spine J 23(11):2473–2569CrossRef Schaffarczyk D, Lauweryns P, Willems K (2014) Functionalized PEEK surface for biomimetic spine-fusion-implants: comparison of BIC and BV/TV values of titanium coated and un-coated PEEK implants in an animal model. Eur Spine J 23(11):2473–2569CrossRef
29.
Zurück zum Zitat Portalupi S, von Elm E, Schmucker C, Lang B, Motschall E, Schwarzer G et al (2013) Protocol for a systematic review on the extent of non-publication of research studies and associated study characteristics. Syst Rev 2(2):2CrossRefPubMedPubMedCentral Portalupi S, von Elm E, Schmucker C, Lang B, Motschall E, Schwarzer G et al (2013) Protocol for a systematic review on the extent of non-publication of research studies and associated study characteristics. Syst Rev 2(2):2CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Sox H, McNeil B, Eden J, Wheatley B (2008) Knowing What works in health care: a roadmap for the nation. National Academies Press, Washington, DC Sox H, McNeil B, Eden J, Wheatley B (2008) Knowing What works in health care: a roadmap for the nation. National Academies Press, Washington, DC
31.
Zurück zum Zitat Scherer RW, Huynh L, Ervin AM, Taylor J, Dickersin K (2013) ClinicalTrials.gov registration can supplement information in abstracts for systematic reviews: a comparison study. BMC Med Res Methodol 13:79CrossRefPubMedPubMedCentral Scherer RW, Huynh L, Ervin AM, Taylor J, Dickersin K (2013) ClinicalTrials.gov registration can supplement information in abstracts for systematic reviews: a comparison study. BMC Med Res Methodol 13:79CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Tumialán LM, Pan J, Rodts GE Jr, Mummaneni PV (2008) The safety and efficacy of anterior cervical discectomy and fusion with polyetheretherketone spacer and recombinant human bone morphogenetic protein–2: a review of 200 patients. J Neurosurg 8(6):529–535 Tumialán LM, Pan J, Rodts GE Jr, Mummaneni PV (2008) The safety and efficacy of anterior cervical discectomy and fusion with polyetheretherketone spacer and recombinant human bone morphogenetic protein–2: a review of 200 patients. J Neurosurg 8(6):529–535
33.
Zurück zum Zitat Ni J, Zheng Y, Liu N, Wang X, Fang X, Phukan R et al (2015) Radiological evaluation of anterior lumbar fusion using PEEK cages with adjacent vertebral autograft in spinal deformity long fusion surgeries. Eur Spine J 24(4):791–799PubMed Ni J, Zheng Y, Liu N, Wang X, Fang X, Phukan R et al (2015) Radiological evaluation of anterior lumbar fusion using PEEK cages with adjacent vertebral autograft in spinal deformity long fusion surgeries. Eur Spine J 24(4):791–799PubMed
34.
Zurück zum Zitat Young JM, Solomon MJ (2009) How to critically appraise an article. Nat Clin Pract Gastroenterol Hepatol 6(2):82–91CrossRefPubMed Young JM, Solomon MJ (2009) How to critically appraise an article. Nat Clin Pract Gastroenterol Hepatol 6(2):82–91CrossRefPubMed
35.
Zurück zum Zitat Geneletti S, Richardson S, Best N (2009) Adjusting for selection bias in retrospective, case–control studies. Biostatistics 10(1):17–31CrossRefPubMed Geneletti S, Richardson S, Best N (2009) Adjusting for selection bias in retrospective, case–control studies. Biostatistics 10(1):17–31CrossRefPubMed
36.
Zurück zum Zitat Kersten RFMR, van Gaalen SM, de Gast A, Öner FC (2013) Polyetheretherketone (PEEK) cages in cervical applications: a systematic review. Spine J 15(6):1446–1460CrossRefPubMed Kersten RFMR, van Gaalen SM, de Gast A, Öner FC (2013) Polyetheretherketone (PEEK) cages in cervical applications: a systematic review. Spine J 15(6):1446–1460CrossRefPubMed
37.
Zurück zum Zitat Goldstein C, Petis S, Kowalczuk M, Drew B, Petrisor B, Bhandari M (2010) Radiologic assessment of lumbar spine fusion: is it confused? Spine J 10(9):S71CrossRef Goldstein C, Petis S, Kowalczuk M, Drew B, Petrisor B, Bhandari M (2010) Radiologic assessment of lumbar spine fusion: is it confused? Spine J 10(9):S71CrossRef
Metadaten
Titel
Radiological and clinical outcomes of novel Ti/PEEK combined spinal fusion cages: a systematic review and preclinical evaluation
verfasst von
Yusuf Assem
Ralph J. Mobbs
Matthew H. Pelletier
Kevin Phan
William R. Walsh
Publikationsdatum
15.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 3/2017
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-4353-8

Weitere Artikel der Ausgabe 3/2017

European Spine Journal 3/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.