Skip to main content
Erschienen in: Clinical Oral Investigations 6/2010

01.12.2010 | Short Communication

Relationship between DIAGNOdent values and sealant penetration depth on occlusal fissures

verfasst von: Jonas A. Rodrigues, Michele B. Diniz, Isabel Hug, Rita C. L. Cordeiro, Adrian Lussi

Erschienen in: Clinical Oral Investigations | Ausgabe 6/2010

Einloggen, um Zugang zu erhalten

Abstract

The aim of this in vitro study was to evaluate the relationship between laser fluorescence values and sealant penetration depth on occlusal fissures. One hundred and sixty-six permanent molars were selected and divided into four groups, which were each treated using a different sealant (two clear and two opaque). The teeth were independently measured twice by two experienced dentists using two laser fluorescence devices—DIAGNOdent (LF and LFpen)—before and after sealing, and then thermoclycled. After measuring, the teeth were histologically prepared and assessed for caries extension. Digital photographs of the cut sealed sites were assessed, and the sealant penetration depth was measured. All 166 sites were measured by one of the examiners taking as limits the outer and inner surface of the sealant into the fissure. For each device (LF and LFpen) and each group, the difference between the values at baseline and after sealing was plotted against the sealant penetration depth and scatter plots were provided. It could be observed that most of the points were concentrated around the zero line, for both LF and LFpen in the four groups. In conclusion, there is no relation between changes in DIAGNOdent values and increasing of depth sealant penetration within the occlusal fissures.
Literatur
1.
Zurück zum Zitat Manton DJ, Messer LB (1995) Pit and fissure sealants: another major cornerstone in preventive dentistry. Aust Dent J 40:20–29CrossRef Manton DJ, Messer LB (1995) Pit and fissure sealants: another major cornerstone in preventive dentistry. Aust Dent J 40:20–29CrossRef
2.
Zurück zum Zitat Simonsen RJ (1991) Retention and effectiveness of dental sealant after 15 years. J Am Dent Assoc 122:34–42PubMed Simonsen RJ (1991) Retention and effectiveness of dental sealant after 15 years. J Am Dent Assoc 122:34–42PubMed
3.
Zurück zum Zitat Mertz-Fairhurst EJ, Curtis JW Jr, Ergle JW, Rueggeberg FA, Adair SM (1998) Ultraconservative and cariostatic sealed restorations: results at year 10. J Am Dent Assoc 129:55–66PubMed Mertz-Fairhurst EJ, Curtis JW Jr, Ergle JW, Rueggeberg FA, Adair SM (1998) Ultraconservative and cariostatic sealed restorations: results at year 10. J Am Dent Assoc 129:55–66PubMed
4.
Zurück zum Zitat Simonsen RJ (2002) Pit and fissure sealant: review of the literature. Pediatr Dent 24:393–414PubMed Simonsen RJ (2002) Pit and fissure sealant: review of the literature. Pediatr Dent 24:393–414PubMed
5.
Zurück zum Zitat Diniz MB, Rodrigues JA, Hug I, Cordeiro RC, Lussi A (2008) The influence of pit and fissure sealants on infrared fluorescence measurements. Caries Res 42:328–333CrossRefPubMed Diniz MB, Rodrigues JA, Hug I, Cordeiro RC, Lussi A (2008) The influence of pit and fissure sealants on infrared fluorescence measurements. Caries Res 42:328–333CrossRefPubMed
6.
Zurück zum Zitat Hibst R, Paulus R, Lussi A (2001) A detection of occlusal caries by laser fluorescence: basic and clinical investigations. Med Laser Appl 16:295–213CrossRef Hibst R, Paulus R, Lussi A (2001) A detection of occlusal caries by laser fluorescence: basic and clinical investigations. Med Laser Appl 16:295–213CrossRef
7.
Zurück zum Zitat Bader JD, Shugars DA (2004) A systematic review of the performance of a laser fluorescence device for detecting caries. J Am Dent Assoc 135:1413–1426PubMed Bader JD, Shugars DA (2004) A systematic review of the performance of a laser fluorescence device for detecting caries. J Am Dent Assoc 135:1413–1426PubMed
8.
Zurück zum Zitat Rodrigues JA, Hug I, Diniz MB, Lussi A (2008) Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro. Caries Res 42:297–304CrossRefPubMed Rodrigues JA, Hug I, Diniz MB, Lussi A (2008) Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro. Caries Res 42:297–304CrossRefPubMed
9.
Zurück zum Zitat Sheehy EC, Brailsford SR, Kidd EAM, Beighton D, Zoitopoulos L (2001) Comparison between visual examination and a laser fluorescence system for in vivo diagnosis of occlusal caries. Caries Res 35:421–426CrossRefPubMed Sheehy EC, Brailsford SR, Kidd EAM, Beighton D, Zoitopoulos L (2001) Comparison between visual examination and a laser fluorescence system for in vivo diagnosis of occlusal caries. Caries Res 35:421–426CrossRefPubMed
10.
Zurück zum Zitat Lussi A, Imwinkelried S, Pitts N, Longbottom C, Reich E (1999) Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro. Caries Res 33:261–266CrossRefPubMed Lussi A, Imwinkelried S, Pitts N, Longbottom C, Reich E (1999) Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro. Caries Res 33:261–266CrossRefPubMed
11.
Zurück zum Zitat Lussi A, Hellwig E (2006) Performance of a new laser fluorescence device for the detection of occlusal caries in vitro. J Dent 34:467–471CrossRefPubMed Lussi A, Hellwig E (2006) Performance of a new laser fluorescence device for the detection of occlusal caries in vitro. J Dent 34:467–471CrossRefPubMed
12.
Zurück zum Zitat Diniz MB, Rodrigues JD, Paula AB, Cordeiro RD (2009) In vivo evaluation of laser fluorescence performance using different cut-off limits for occlusal caries detection. Lasers Med Sci 24:295–300CrossRefPubMed Diniz MB, Rodrigues JD, Paula AB, Cordeiro RD (2009) In vivo evaluation of laser fluorescence performance using different cut-off limits for occlusal caries detection. Lasers Med Sci 24:295–300CrossRefPubMed
13.
Zurück zum Zitat Lussi A, Reich E (2005) The influence of toothpastes and prophylaxis pastes on fluorescence measurements for caries detection in vitro. Eur J Oral Sci 113:141–144CrossRefPubMed Lussi A, Reich E (2005) The influence of toothpastes and prophylaxis pastes on fluorescence measurements for caries detection in vitro. Eur J Oral Sci 113:141–144CrossRefPubMed
14.
Zurück zum Zitat Hosoya Y, Matsuzaka K, Inoue T, GW M (2004) Influence of tooth-polishing pastes and sealants on DIAGNOdent values. Quintessence Int 35:605–611PubMed Hosoya Y, Matsuzaka K, Inoue T, GW M (2004) Influence of tooth-polishing pastes and sealants on DIAGNOdent values. Quintessence Int 35:605–611PubMed
15.
Zurück zum Zitat Anttonen V, Seppä L, Hausen H (2003) Clinical study of the use of the laser fluorescence device DIAGNOdent for detection of occlusal caries in children. Caries Res 37:17–23CrossRefPubMed Anttonen V, Seppä L, Hausen H (2003) Clinical study of the use of the laser fluorescence device DIAGNOdent for detection of occlusal caries in children. Caries Res 37:17–23CrossRefPubMed
16.
Zurück zum Zitat Deery C, Iloya J, Nugent ZJ, Srinivasan V (2006) Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: An in vitro study. Caries Res 40:186–193CrossRefPubMed Deery C, Iloya J, Nugent ZJ, Srinivasan V (2006) Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: An in vitro study. Caries Res 40:186–193CrossRefPubMed
17.
Zurück zum Zitat Krause F, Braun A, Frentzen M, Jepsen S (2008) Effects of composite fissure sealants on IR laser fluorescence measurements. Lasers Med Sci 23:133–139CrossRefPubMed Krause F, Braun A, Frentzen M, Jepsen S (2008) Effects of composite fissure sealants on IR laser fluorescence measurements. Lasers Med Sci 23:133–139CrossRefPubMed
18.
Zurück zum Zitat Takamori K, Hokari N, Okumura Y, Watanabe S (2001) Detection of occlusal caries under sealants by use of a laser fluorescence system. J Clin Laser Med Surg 19:267–271CrossRefPubMed Takamori K, Hokari N, Okumura Y, Watanabe S (2001) Detection of occlusal caries under sealants by use of a laser fluorescence system. J Clin Laser Med Surg 19:267–271CrossRefPubMed
19.
Zurück zum Zitat Gostanian HV, Shey Z, Kasinathan C, Caceda J, Janal MN (2006) An in vitro evaluation of the effect of sealant characteristics on laser fluorescence for caries detection. Pediatr Dent 28:445–450PubMed Gostanian HV, Shey Z, Kasinathan C, Caceda J, Janal MN (2006) An in vitro evaluation of the effect of sealant characteristics on laser fluorescence for caries detection. Pediatr Dent 28:445–450PubMed
20.
Zurück zum Zitat Celiberti P, Lussi A (2007) Penetration ability and microleakage of a fissure sealant applied on artificial and natural enamel fissure caries. J Dent 35:59–67CrossRefPubMed Celiberti P, Lussi A (2007) Penetration ability and microleakage of a fissure sealant applied on artificial and natural enamel fissure caries. J Dent 35:59–67CrossRefPubMed
21.
Zurück zum Zitat Francescut P, Zimmerli B, Lussi A (2006) Influence of different storage methods on laser fluorescence values: A two-year study. Caries Res 40:181–185CrossRefPubMed Francescut P, Zimmerli B, Lussi A (2006) Influence of different storage methods on laser fluorescence values: A two-year study. Caries Res 40:181–185CrossRefPubMed
22.
Zurück zum Zitat Deery C, Fyffe H, Nugent Z, Nuttall N, Pitts N (1995) The effect of placing a clear pit and fissure sealant on the validity and reproducibility of occlusal caries diagnosis. Caries Res 29:377–381CrossRefPubMed Deery C, Fyffe H, Nugent Z, Nuttall N, Pitts N (1995) The effect of placing a clear pit and fissure sealant on the validity and reproducibility of occlusal caries diagnosis. Caries Res 29:377–381CrossRefPubMed
23.
Zurück zum Zitat Carvalho JC, Ekstrand KR, Thylstrup A (1989) Dental plaque and caries on occlusal surfaces of first permanent molars in relation to stage of eruption. J Dent Res 68:773–779PubMed Carvalho JC, Ekstrand KR, Thylstrup A (1989) Dental plaque and caries on occlusal surfaces of first permanent molars in relation to stage of eruption. J Dent Res 68:773–779PubMed
24.
Zurück zum Zitat Pearce EIF, Larsen M, Coote G (1999) Fluoride in enamel lining pits and fissures of the occlusal groove–fossa system in human molar teeth. Caries Res 33:196–205CrossRefPubMed Pearce EIF, Larsen M, Coote G (1999) Fluoride in enamel lining pits and fissures of the occlusal groove–fossa system in human molar teeth. Caries Res 33:196–205CrossRefPubMed
25.
Zurück zum Zitat Rock WP, Weatherill S, Anderson RJ (1990) Retention of three fissure sealants resins. The effects of etching agent and curing method. Results over 3 years. Br Dent J 168:232–325 Rock WP, Weatherill S, Anderson RJ (1990) Retention of three fissure sealants resins. The effects of etching agent and curing method. Results over 3 years. Br Dent J 168:232–325
Metadaten
Titel
Relationship between DIAGNOdent values and sealant penetration depth on occlusal fissures
verfasst von
Jonas A. Rodrigues
Michele B. Diniz
Isabel Hug
Rita C. L. Cordeiro
Adrian Lussi
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 6/2010
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-009-0321-1

Weitere Artikel der Ausgabe 6/2010

Clinical Oral Investigations 6/2010 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.