In this study, we proposed an approach able to predict whether a pregnant woman with contractions would give birth earlier than expected (i.e., before the 37 t h week of gestation (WG)). It only processes non-invasive electrohysterographic (EHG) signals fully automatically without assistance of an expert or an additional medical system. We used term and preterm EHG signals of 30-minutes duration collected between the 27 t h and the 32 n d WG. Preterm deliveries (< 37W G) had occurred in average 4.00 ± 1.88 weeks since recording dates. Each recording contains three bipolar channels. Using the Huang-Hilbert transform (HHT), we obtained up to twelve intrinsic mode functions (IMFs) for each signal. We found that the most relevant IMFs for both term and preterm records were IMF3 and IMF6. From these two IMFs, we extracted 8 most relevant features targeting EHG signal specificities. We investigated features classifications using support vector machine (SVM) for the 3 single-channels and for all their possible combinations. High discrimination power between term and preterm EHG records was obtained with linear-SVM classifiers. For almost all the cases, mean areas under curves (AUC) exceeded 0.92. A two-channel combination (7 features) achieved the best mean results with A c c u r a c y = 95.70%, S e n s i t i v i t y = 98.40%, S p e c i f i c i t y = 93.00% and A U C = 0.95. Results of the three-channel combination (9 features) were A c c u r a c y = 92.30%, S e n s i t i v i t y = 93.00%, S p e c i f i c i t y = 91.60% and A U C = 0.96. The best single-channel (8 features) gave the mean values: A c c u r a c y = 90.40%, S e n s i t i v i t y = 93.60% and A U C = 0.94. Thus, the advantage of our approach is the high diagnostic performance at low computational cost.
Literatur
1.
Zurück zum Zitat Acharya, U. R., Sudarshan, V. K., Rong, S. Q., Tan, Z., Lim, C. M., Koh, J. E., Nayak, S., and Bhandary, S. V., Automated detection of premature delivery using empirical mode and wavelet packet decomposition techniques with uterine electromyogram signals. Comput. Biol. Med. 85:33–42, 2017. Acharya, U. R., Sudarshan, V. K., Rong, S. Q., Tan, Z., Lim, C. M., Koh, J. E., Nayak, S., and Bhandary, S. V., Automated detection of premature delivery using empirical mode and wavelet packet decomposition techniques with uterine electromyogram signals. Comput. Biol. Med. 85:33–42, 2017.
3.
Zurück zum Zitat Blanco-Velasco, M., Weng, B., and Barner, K. E., Ecg signal denoising and baseline wander correction based on the empirical mode decomposition. Comput. Biol. Med. 38(1):1–13, 2008. Blanco-Velasco, M., Weng, B., and Barner, K. E., Ecg signal denoising and baseline wander correction based on the empirical mode decomposition. Comput. Biol. Med. 38(1):1–13, 2008.
4.
5.
Zurück zum Zitat Debnath, L., Recent developments in the wigner-ville distribution and time-frequency signal analysis. Proceedings-Indian National Science Academy Part A 68(1):35–56, 2002. Debnath, L., Recent developments in the wigner-ville distribution and time-frequency signal analysis. Proceedings-Indian National Science Academy Part A 68(1):35–56, 2002.
6.
Zurück zum Zitat DeLong, E. R., DeLong, D. M., and Clarke-Pearson, D. L., Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44:837–845, 1988. DeLong, E. R., DeLong, D. M., and Clarke-Pearson, D. L., Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44:837–845, 1988.
7.
Zurück zum Zitat Devedeux, D., Marque, C., Mansour, S., Germain, G., and Duchêne, J., Uterine electromyography: a critical review. Am. J. Obstet. Gynecol. 169(6):1636–1653, 1993. Devedeux, D., Marque, C., Mansour, S., Germain, G., and Duchêne, J., Uterine electromyography: a critical review. Am. J. Obstet. Gynecol. 169(6):1636–1653, 1993.
8.
Zurück zum Zitat Diab, M. O., El-Merhie, A., El-Halabi, N., and Khoder, L., Classification of uterine emg signals using supervised classification method. J. Biomed. Sci. Eng. 3(9):837, 2010. Diab, M. O., El-Merhie, A., El-Halabi, N., and Khoder, L., Classification of uterine emg signals using supervised classification method. J. Biomed. Sci. Eng. 3(9):837, 2010.
9.
Zurück zum Zitat Doret, M., Pasquier, J., Gharib, C., and Gaucherand, P., Uterine electromyogram: principle and interest in the diagnosis of preterm labour. J. Gynecol. Obstet. Biol. Reprod. 37(1):24–32, 2008. Doret, M., Pasquier, J., Gharib, C., and Gaucherand, P., Uterine electromyogram: principle and interest in the diagnosis of preterm labour. J. Gynecol. Obstet. Biol. Reprod. 37(1):24–32, 2008.
10.
Zurück zum Zitat Duchene, J., Devedeux, D., Mansour, S., and Marque, C., Analyzing uterine emg: tracking instantaneous burst frequency. IEEE Eng. Med. Biol. Mag. 14(2):125–132, 1995. Duchene, J., Devedeux, D., Mansour, S., and Marque, C., Analyzing uterine emg: tracking instantaneous burst frequency. IEEE Eng. Med. Biol. Mag. 14(2):125–132, 1995.
11.
Zurück zum Zitat Fawcett, T., Roc graphs: Notes and practical considerations for data mining researchers. Copyright HP Co, 2003. Fawcett, T., Roc graphs: Notes and practical considerations for data mining researchers. Copyright HP Co, 2003.
12.
Zurück zum Zitat Fele-Żorż, G., Kavṡek, G., Novak-Antoliċ, Ż., and Jager, F., A comparison of various linear and non-linear signal processing techniques to separate uterine emg records of term and pre-term delivery groups. Med. Biol. Eng. Comput. 46(9):911–922, 2008. Fele-Żorż, G., Kavṡek, G., Novak-Antoliċ, Ż., and Jager, F., A comparison of various linear and non-linear signal processing techniques to separate uterine emg records of term and pre-term delivery groups. Med. Biol. Eng. Comput. 46(9):911–922, 2008.
13.
Zurück zum Zitat Fergus, P., Cheung, P., Hussain, A., Al-Jumeily, D., Dobbins, C., and Iram, S., Prediction of preterm deliveries from ehg signals using machine learning. PloS one 8(10):e77,154, 2013. Fergus, P., Cheung, P., Hussain, A., Al-Jumeily, D., Dobbins, C., and Iram, S., Prediction of preterm deliveries from ehg signals using machine learning. PloS one 8(10):e77,154, 2013.
14.
Zurück zum Zitat Flandrin, P., Gonċalves, P., and Rilling, G., EMD equivalent filter banks, from interpretation to applications. In: Huang, NE and Shen, SSP (Eds.) Hilbert-Huang Transform and Its Applications, chapter 5, pp 57–74. Singapore: World Scientific, 2005. Flandrin, P., Gonċalves, P., and Rilling, G., EMD equivalent filter banks, from interpretation to applications. In: Huang, NE and Shen, SSP (Eds.) Hilbert-Huang Transform and Its Applications, chapter 5, pp 57–74. Singapore: World Scientific, 2005.
15.
Zurück zum Zitat Fraiwan, L., Predicting preterm delivery based on wavelet packet analysis of a single electrohysterography channel. J. Med. Imaging Health Inf. 6(6):1419–1425, 2016. Fraiwan, L., Predicting preterm delivery based on wavelet packet analysis of a single electrohysterography channel. J. Med. Imaging Health Inf. 6(6):1419–1425, 2016.
16.
Zurück zum Zitat Garfield, R. E., Maner, W. L., MacKay, L. B., Schlembach, D., and Saade, G. R., Comparing uterine electromyography activity of antepartum patients versus term labor patients. Am. J. Obstet. Gynecol. 193(1):23–29, 2005. Garfield, R. E., Maner, W. L., MacKay, L. B., Schlembach, D., and Saade, G. R., Comparing uterine electromyography activity of antepartum patients versus term labor patients. Am. J. Obstet. Gynecol. 193(1):23–29, 2005.
17.
Zurück zum Zitat Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C. K., and Stanley, H. E., PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation 101(23):e215—e220, 2000. https://doi.org/10.1161/01.CIR.101.23.e215. Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C. K., and Stanley, H. E., PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation 101(23):e215—e220, 2000. https://​doi.​org/​10.​1161/​01.​CIR.​101.​23.​e215.
18.
Zurück zum Zitat Hajian-Tilaki, K., Receiver operating characteristic (roc) curve analysis for medical diagnostic test evaluation. Caspian J. Intern. Med. 4(2):627, 2013. Hajian-Tilaki, K., Receiver operating characteristic (roc) curve analysis for medical diagnostic test evaluation. Caspian J. Intern. Med. 4(2):627, 2013.
19.
Zurück zum Zitat Hanley, J. A., and McNeil, B. J., The meaning and use of the area under a receiver operating characteristic (roc) curve. Radiology 143(1):29–36, 1982. Hanley, J. A., and McNeil, B. J., The meaning and use of the area under a receiver operating characteristic (roc) curve. Radiology 143(1):29–36, 1982.
20.
Zurück zum Zitat Hanley, J. A., and McNeil, B. J., A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148(3):839–843, 1983. Hanley, J. A., and McNeil, B. J., A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148(3):839–843, 1983.
21.
Zurück zum Zitat Hassan, M., Alexandersson, A., Terrien, J., Karlsson, B., and Marque, C., Wavelet phase synchronization between ehgs at different uterine sites: comparison of pregnancy and labor contractions. In: XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, Springer, pp 21–24, 2010. Hassan, M., Alexandersson, A., Terrien, J., Karlsson, B., and Marque, C., Wavelet phase synchronization between ehgs at different uterine sites: comparison of pregnancy and labor contractions. In: XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, Springer, pp 21–24, 2010.
22.
Zurück zum Zitat Hassan, M., Boudaoud, S., Terrien, J., Karlsson, B., and Marque, C., Combination of canonical correlation analysis and empirical mode decomposition applied to denoising the labor electrohysterogram. IEEE Trans. Biomed. Eng. 58(9):2441–2447, 2011. Hassan, M., Boudaoud, S., Terrien, J., Karlsson, B., and Marque, C., Combination of canonical correlation analysis and empirical mode decomposition applied to denoising the labor electrohysterogram. IEEE Trans. Biomed. Eng. 58(9):2441–2447, 2011.
23.
Zurück zum Zitat Hassan, M., Terrien, J., Muszynski, C., Alexandersson, A., Marque, C., and Karlsson, B., Better pregnancy monitoring using nonlinear correlation analysis of external uterine electromyography. IEEE Trans. Biomed. Eng. 60(4):1160–1166, 2013. Hassan, M., Terrien, J., Muszynski, C., Alexandersson, A., Marque, C., and Karlsson, B., Better pregnancy monitoring using nonlinear correlation analysis of external uterine electromyography. IEEE Trans. Biomed. Eng. 60(4):1160–1166, 2013.
24.
Zurück zum Zitat Huang, N. E., Hilbert-Huang transform and its applications. Vol 16 Singapore: World Scientific, 2014. Huang, N. E., Hilbert-Huang transform and its applications. Vol 16 Singapore: World Scientific, 2014.
25.
Zurück zum Zitat Jacod, B. C., Graatsma, E. M., Van Hagen, E., and Visser, G. H., A validation of electrohysterography for uterine activity monitoring during labour. J. Matern. Fetal Neonatal Med. 23(1):17–22, 2010. Jacod, B. C., Graatsma, E. M., Van Hagen, E., and Visser, G. H., A validation of electrohysterography for uterine activity monitoring during labour. J. Matern. Fetal Neonatal Med. 23(1):17–22, 2010.
26.
Zurück zum Zitat de Lau, H., Rabotti, C., Oosterbaan, H. P., Mischi, M., and Oei, G. S., Study protocol: Pope-prediction of preterm delivery by electrohysterography. BMC Pregnancy Childbirth 14(1):192, 2014. de Lau, H., Rabotti, C., Oosterbaan, H. P., Mischi, M., and Oei, G. S., Study protocol: Pope-prediction of preterm delivery by electrohysterography. BMC Pregnancy Childbirth 14(1):192, 2014.
27.
Zurück zum Zitat Lucovnik, M., Maner, W. L., Chambliss, L. R., Blumrick, R., Balducci, J., Novak-Antolic, Z., and Garfield, R. E., Noninvasive uterine electromyography for prediction of preterm delivery. Am. J. Obstet. Gynecol. 204(3):228–e1, 2011. Lucovnik, M., Maner, W. L., Chambliss, L. R., Blumrick, R., Balducci, J., Novak-Antolic, Z., and Garfield, R. E., Noninvasive uterine electromyography for prediction of preterm delivery. Am. J. Obstet. Gynecol. 204(3):228–e1, 2011.
28.
Zurück zum Zitat Maner, W. L., Garfield, R. E., Maul, H., Olson, G., and Saade, G., Predicting term and preterm delivery with transabdominal uterine electromyography. Obstet. Gynecol. 101(6):1254–1260, 2003. Maner, W. L., Garfield, R. E., Maul, H., Olson, G., and Saade, G., Predicting term and preterm delivery with transabdominal uterine electromyography. Obstet. Gynecol. 101(6):1254–1260, 2003.
29.
Zurück zum Zitat Provost, F. J., Fawcett, T., and et al, Analysis and visualization of classifier performance: comparison under imprecise class and cost distributions. In: KDD, Vol. 97, pp. 43–48, 1997. Provost, F. J., Fawcett, T., and et al, Analysis and visualization of classifier performance: comparison under imprecise class and cost distributions. In: KDD, Vol. 97, pp. 43–48, 1997.
30.
Zurück zum Zitat Ren, P., Yao, S., Li, J., Valdes-Sosa, P. A., and Kendrick, K. M., Improved prediction of preterm delivery using empirical mode decomposition analysis of uterine electromyography signals. PloS one 10(7):e0132,116, 2015. Ren, P., Yao, S., Li, J., Valdes-Sosa, P. A., and Kendrick, K. M., Improved prediction of preterm delivery using empirical mode decomposition analysis of uterine electromyography signals. PloS one 10(7):e0132,116, 2015.
31.
Zurück zum Zitat Rilling, G., Flandrin, P., Goncalves, P., and et al, On empirical mode decomposition and its algorithms. In: IEEE-EURASIP workshop nonlinear signal image process, IEEER, Grado, Italy, Vol. 3, pp. 8–11, 2003. Rilling, G., Flandrin, P., Goncalves, P., and et al, On empirical mode decomposition and its algorithms. In: IEEE-EURASIP workshop nonlinear signal image process, IEEER, Grado, Italy, Vol. 3, pp. 8–11, 2003.
32.
Zurück zum Zitat Terrien, J., Marque, C., and Karlsson, B., Spectral characterization of human ehg frequency components based on the extraction and reconstruction of the ridges in the scalogram, pp. Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, IEEE, pp 1872–1875, 2007. Terrien, J., Marque, C., and Karlsson, B., Spectral characterization of human ehg frequency components based on the extraction and reconstruction of the ridges in the scalogram, pp. Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, IEEE, pp 1872–1875, 2007.
33.
Zurück zum Zitat Vapnik, V., The nature of statistical learning theory. Berlin: Springer science & business media, 2013. Vapnik, V., The nature of statistical learning theory. Berlin: Springer science & business media, 2013.
34.
Zurück zum Zitat Vrhovec, J., Rudel, D., Pajntar, M., and Lebar, A. M., A uterine electromyographic activity as a measure of labour progression. Zdrav Vestn 79(2), (2010). Vrhovec, J., Rudel, D., Pajntar, M., and Lebar, A. M., A uterine electromyographic activity as a measure of labour progression. Zdrav Vestn 79(2), (2010).
35.
Zurück zum Zitat Weng, B., and Barner, K. E. Optimal signal reconstruction using the empirical mode decomposition. EURASIP J Adv Signal Process, 2008. Weng, B., and Barner, K. E. Optimal signal reconstruction using the empirical mode decomposition. EURASIP J Adv Signal Process, 2008.
36.
Zurück zum Zitat Yan, R., and Gao, R. X., Rotary machine health diagnosis based on empirical mode decomposition. J. Vib. Acoust. 130(2):1–12, 2008. Yan, R., and Gao, R. X., Rotary machine health diagnosis based on empirical mode decomposition. J. Vib. Acoust. 130(2):1–12, 2008.
37.
Zurück zum Zitat Zweig, M. H., and Campbell, G., Receiver-operating characteristic (roc) plots: a fundamental evaluation tool in clinical medicine. Clin. Chem. 39(4):561–577, 1993. Zweig, M. H., and Campbell, G., Receiver-operating characteristic (roc) plots: a fundamental evaluation tool in clinical medicine. Clin. Chem. 39(4):561–577, 1993.
Metadaten
Titel
Relevant Features Selection for Automatic Prediction of Preterm Deliveries from Pregnancy ElectroHysterograhic (EHG) records
verfasst von
Nafissa Sadi-Ahmed
Baya Kacha
Hamza Taleb
Malika Kedir-Talha
Publikationsdatum
01.12.2017
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 12/2017
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-017-0847-8

Weitere Artikel der Ausgabe 12/2017

Journal of Medical Systems 12/2017 Zur Ausgabe