Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 2/2013

01.02.2013 | Hip Arthroplasty

Results of metal-on-metal hip resurfacing in patients 40 years old and younger

verfasst von: Aleksi Reito, Antti Eskelinen, Timo Puolakka, Jorma Pajamäki

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 2/2013

Einloggen, um Zugang zu erhalten

Abstract

The prevalence of total hip arthroplasty in young patients is small but increasing. We analyzed the results of metal-on-metal hip resurfacing (MMHR) in patients aged 40 years or less. In total 74 operations were performed on 64 patients. Mean age at operation was 33.2 years. HHS averaged 92.3 points at latest follow-up, mean UCLA activity was 8.2. Patients with comorbidity evinced lower scores in HHS, in UCLA activity and in quality of life than patients without comorbidities. Eight revisions (10.8 %) were performed, of which seven due to adverse reaction to metal debris. Seven-year survival was 90.5 %. The functional outcome of hip resurfacing in this cohort was excellent, but overall survival was unsatisfactory. Further analysis is required to verify the role of hip resurfacing among young and active patients.
Literatur
1.
Zurück zum Zitat Skyttä ET, Jarkko L, Antti E, Huhtala H, Ville R (2011) Increasing incidence of hip arthroplasty for primary osteoarthritis in 30- to 59-year-old patients. Acta Orthop 82(1):1–5PubMedCrossRef Skyttä ET, Jarkko L, Antti E, Huhtala H, Ville R (2011) Increasing incidence of hip arthroplasty for primary osteoarthritis in 30- to 59-year-old patients. Acta Orthop 82(1):1–5PubMedCrossRef
2.
Zurück zum Zitat Johanson PE, Fenstad AM, Furnes O, Garellick G, Havelin LI, Overgaard S et al (2010) Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty. Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007. Acta Orthop 81(5):535–541 Johanson PE, Fenstad AM, Furnes O, Garellick G, Havelin LI, Overgaard S et al (2010) Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty. Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007. Acta Orthop 81(5):535–541
3.
Zurück zum Zitat Beaule PE, Lee JL, Le Duff MJ, Amstutz HC, Ebramzadeh E (2004) Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. J Bone Joint Surg [Am] 86(9):2015–2021 Beaule PE, Lee JL, Le Duff MJ, Amstutz HC, Ebramzadeh E (2004) Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. J Bone Joint Surg [Am] 86(9):2015–2021
4.
Zurück zum Zitat Amstutz HC, Le Duff MJ, Beaule PE (2004) Prevention and treatment of dislocation after total hip replacement using large diameter balls. Clin Orthop 429:108–116PubMedCrossRef Amstutz HC, Le Duff MJ, Beaule PE (2004) Prevention and treatment of dislocation after total hip replacement using large diameter balls. Clin Orthop 429:108–116PubMedCrossRef
5.
Zurück zum Zitat Coulter G, Young DA, Dalziel RE, Shimmin AJ (2012) Birmingham hip resurfacing at a mean of ten years: results from an independent centre. J Bone Joint Surg [Br] 94(3):315–321 Coulter G, Young DA, Dalziel RE, Shimmin AJ (2012) Birmingham hip resurfacing at a mean of ten years: results from an independent centre. J Bone Joint Surg [Br] 94(3):315–321
6.
Zurück zum Zitat Holland JP, Langton DJ, Hashmi M (2012) Ten-year clinical, radiological and metal ion analysis of the Birmingham hip resurfacing: from a single, non-designer surgeon. J Bone Joint Surg [Br] 94(4):471–476 Holland JP, Langton DJ, Hashmi M (2012) Ten-year clinical, radiological and metal ion analysis of the Birmingham hip resurfacing: from a single, non-designer surgeon. J Bone Joint Surg [Br] 94(4):471–476
7.
Zurück zum Zitat Treacy RB, McBryde CW, Shears E, Pynsent PB (2011) Birmingham hip resurfacing: a minimum follow-up of ten years. J Bone Joint Surg [Br] 93(1):27–33 Treacy RB, McBryde CW, Shears E, Pynsent PB (2011) Birmingham hip resurfacing: a minimum follow-up of ten years. J Bone Joint Surg [Br] 93(1):27–33
8.
Zurück zum Zitat Baker RP, Pollard TC, Eastaugh-Waring SJ, Bannister GC (2011) A medium-term comparison of hybrid hip replacement and Birmingham hip resurfacing in active young patients. J Bone Joint Surg [Br] 93(2):158–163 Baker RP, Pollard TC, Eastaugh-Waring SJ, Bannister GC (2011) A medium-term comparison of hybrid hip replacement and Birmingham hip resurfacing in active young patients. J Bone Joint Surg [Br] 93(2):158–163
9.
Zurück zum Zitat No authors listed. Australian Orthopaedic Association National Joint Replacement Registry: hip and knee arthroplasty annual report 2010 No authors listed. Australian Orthopaedic Association National Joint Replacement Registry: hip and knee arthroplasty annual report 2010
10.
Zurück zum Zitat Glyn-Jones S, Pandit H, Kwon YM, Doll H, Gill HS, Murray DW (2009) Risk factors for inflammatory pseudotumour formation following hip resurfacing. J Bone Joint Surg [Br] 91(12):1566–1574 Glyn-Jones S, Pandit H, Kwon YM, Doll H, Gill HS, Murray DW (2009) Risk factors for inflammatory pseudotumour formation following hip resurfacing. J Bone Joint Surg [Br] 91(12):1566–1574
11.
Zurück zum Zitat Cunningham WE, Nakazono TT, Tsai KL, Hays RD (2003) Do differences in methods for constructing SF-36 physical and mental health summary measures change their associations with chronic medical conditions and utilization? Qual Life Res 12(8):1029–1035PubMedCrossRef Cunningham WE, Nakazono TT, Tsai KL, Hays RD (2003) Do differences in methods for constructing SF-36 physical and mental health summary measures change their associations with chronic medical conditions and utilization? Qual Life Res 12(8):1029–1035PubMedCrossRef
12.
Zurück zum Zitat Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP (2011) Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg [Br] 93(2):164–171 Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP (2011) Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg [Br] 93(2):164–171
13.
Zurück zum Zitat Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV (2010) Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg [Br] 92(1):38–46 Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV (2010) Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg [Br] 92(1):38–46
14.
Zurück zum Zitat Le Duff MJ, Amstutz HC (2012) The relationship of sporting activity and implant survivorship after hip resurfacing. J Bone Joint Surg [Am] 94:911–918CrossRef Le Duff MJ, Amstutz HC (2012) The relationship of sporting activity and implant survivorship after hip resurfacing. J Bone Joint Surg [Am] 94:911–918CrossRef
15.
Zurück zum Zitat Seyler TM, Marker DR, Boyd HS, Zywiel MG, McGrath MS, Mont MA (2009) Preoperative evaluation to determine candidates for metal-on-metal hip resurfacing. J Bone Joint Surg [Am] 91(Suppl 6):32–41CrossRef Seyler TM, Marker DR, Boyd HS, Zywiel MG, McGrath MS, Mont MA (2009) Preoperative evaluation to determine candidates for metal-on-metal hip resurfacing. J Bone Joint Surg [Am] 91(Suppl 6):32–41CrossRef
16.
Zurück zum Zitat Sayeed SA, Johnson AJ, Stroh DA, Gross TP, Mont MA (2010) Hip resurfacing in patients who have osteonecrosis and are 25 years or under. Clin Orthop 469(6):1582–1588 Sayeed SA, Johnson AJ, Stroh DA, Gross TP, Mont MA (2010) Hip resurfacing in patients who have osteonecrosis and are 25 years or under. Clin Orthop 469(6):1582–1588
17.
Zurück zum Zitat Aalto AM, Aro AR, Teperi J (1999) RAND-36 terveyteen liittyvän elämänlaadun mittarina:Mittarin luotettavuus ja suomalaiset väestöarvot. STAKES publications, London Aalto AM, Aro AR, Teperi J (1999) RAND-36 terveyteen liittyvän elämänlaadun mittarina:Mittarin luotettavuus ja suomalaiset väestöarvot. STAKES publications, London
18.
Zurück zum Zitat Shimmin AJ, Walter WL, Esposito C (2010) The influence of the size of the component on the outcome of resurfacing arthroplasty of the hip: a review of the literature. J Bone Joint Surg [Br] 92(4):469–476 Shimmin AJ, Walter WL, Esposito C (2010) The influence of the size of the component on the outcome of resurfacing arthroplasty of the hip: a review of the literature. J Bone Joint Surg [Br] 92(4):469–476
19.
Zurück zum Zitat Jeffers JR, Roques A, Taylor A, Tuke MA (2009) The problem with large diameter metal-on-metal acetabular cup inclination. Bull NYU Hosp Jt Dis 67(2):189–192PubMed Jeffers JR, Roques A, Taylor A, Tuke MA (2009) The problem with large diameter metal-on-metal acetabular cup inclination. Bull NYU Hosp Jt Dis 67(2):189–192PubMed
20.
Zurück zum Zitat Khan M, Kuiper JH, Richardson JB (2008) The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg [Br] 90(9):1152–1157CrossRef Khan M, Kuiper JH, Richardson JB (2008) The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg [Br] 90(9):1152–1157CrossRef
21.
Zurück zum Zitat Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP (2005) The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg [Am] 87(4):781–787CrossRef Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP (2005) The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg [Am] 87(4):781–787CrossRef
22.
Zurück zum Zitat Hart AJ, Skinner JA, Henckel J, Sampson B, Gordon F (2011) Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing. Clin Orthop Relat Res 469(9):2590–2597PubMedCrossRef Hart AJ, Skinner JA, Henckel J, Sampson B, Gordon F (2011) Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing. Clin Orthop Relat Res 469(9):2590–2597PubMedCrossRef
23.
Zurück zum Zitat De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg [Br] 90(10):1291–1297 De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg [Br] 90(10):1291–1297
24.
Zurück zum Zitat Catelas I, Wimmer MA (2011) New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg [Am] 93(Suppl 2):76–83CrossRef Catelas I, Wimmer MA (2011) New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg [Am] 93(Suppl 2):76–83CrossRef
Metadaten
Titel
Results of metal-on-metal hip resurfacing in patients 40 years old and younger
verfasst von
Aleksi Reito
Antti Eskelinen
Timo Puolakka
Jorma Pajamäki
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 2/2013
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-012-1640-2

Weitere Artikel der Ausgabe 2/2013

Archives of Orthopaedic and Trauma Surgery 2/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.