Skip to main content
Erschienen in: European Spine Journal 12/2013

01.12.2013 | Original Article

Retrieval analysis of PEEK rods for posterior fusion and motion preservation

verfasst von: Steven M. Kurtz, Todd H. Lanman, Genymphas Higgs, Daniel W. MacDonald, Sigurd H. Berven, Jorge E. Isaza, Eual Phillips, Marla J. Steinbeck

Erschienen in: European Spine Journal | Ausgabe 12/2013

Einloggen, um Zugang zu erhalten

Abstract

Introduction

The purpose of this study was to analyze explanted PEEK rod spinal systems in the context of their clinical indications. We evaluated damage to the implant and histological changes in explanted periprosthetic tissues.

Methods

12 patients implanted with 23 PEEK rods were revised between 2008 and 2012. PEEK rods were of the same design (CD Horizon Legacy, Medtronic, Memphis TN, USA). Retrieved components were assessed for surface damage mechanisms, including plastic deformation, scratching, burnishing, and fracture. Patient history and indications for PEEK rod implantation were obtained from analysis of the medical records.

Results

11/12 PEEK rod systems were employed for fusion at one level, and motion preservation at the adjacent level. Surgical complications in the PEEK cohort included a small dural tear in one case that was immediately repaired. There were no cases of PEEK rod fracture or pedicle screw fracture. Retrieved PEEK rods exhibited scratching, as well as impressions from the set screws and pedicle screw saddles. PEEK debris was observed in two patient tissues, which were located adjacent to PEEK rods with evidence of scratching and burnishing.

Conclusion

This study documents the surface changes and tissue reactions for retrieved PEEK rod stabilization systems. Permanent indentations by the set screws and pedicle screws were the most prevalent observations on the surface of explanted PEEK rods.
Literatur
1.
Zurück zum Zitat Kurtz SM (2012) Applications of polyaryletheretherketone in spinal implants: fusion and motion presevation. In: Kurtz SM (ed) The PEEK Biomaterials Handbook. William Andrew, Elsevier, pp 201–220CrossRef Kurtz SM (2012) Applications of polyaryletheretherketone in spinal implants: fusion and motion presevation. In: Kurtz SM (ed) The PEEK Biomaterials Handbook. William Andrew, Elsevier, pp 201–220CrossRef
2.
Zurück zum Zitat Gornet MF, Chan FW, Coleman JC, Murrell B, Nockels RP, Taylor BA, Lanman TH, Ochoa JA (2011) Biomechanical assessment of a PEEK rod system for semi-rigid fixation of lumbar fusion constructs. J Biomech Eng 133:081009. doi:10.1115/1.4004862 PubMedCrossRef Gornet MF, Chan FW, Coleman JC, Murrell B, Nockels RP, Taylor BA, Lanman TH, Ochoa JA (2011) Biomechanical assessment of a PEEK rod system for semi-rigid fixation of lumbar fusion constructs. J Biomech Eng 133:081009. doi:10.​1115/​1.​4004862 PubMedCrossRef
4.
Zurück zum Zitat Highsmith JM, Tumialan LM, Rodts GE Jr (2007) Flexible rods and the case for dynamic stabilization. Neurosurg Focus 22:E11PubMedCrossRef Highsmith JM, Tumialan LM, Rodts GE Jr (2007) Flexible rods and the case for dynamic stabilization. Neurosurg Focus 22:E11PubMedCrossRef
6.
Zurück zum Zitat Mageswaran P, Techy F, Colbrunn RW, Bonner TF, McLain RF (2012) Hybrid dynamic stabilization: a biomechanical assessment of adjacent and supraadjacent levels of the lumbar spine. J Neurosurg 17:232–242. doi:10.3171/2012.6.SPINE111054 Mageswaran P, Techy F, Colbrunn RW, Bonner TF, McLain RF (2012) Hybrid dynamic stabilization: a biomechanical assessment of adjacent and supraadjacent levels of the lumbar spine. J Neurosurg 17:232–242. doi:10.​3171/​2012.​6.​SPINE111054
7.
Zurück zum Zitat Siewe J, Otto C, Knoell P, Koriller M, Stein G, Kaulhausen T, Eysel P, Zarghooni K, Franklin J, Sobottke R (2011) Comparison of standard fusion with a “topping off” system in lumbar spine surgery: a protocol for a randomized controlled trial. BMC musculoskelet Disord 12:239. doi:10.1186/1471-2474-12-239 PubMedCrossRef Siewe J, Otto C, Knoell P, Koriller M, Stein G, Kaulhausen T, Eysel P, Zarghooni K, Franklin J, Sobottke R (2011) Comparison of standard fusion with a “topping off” system in lumbar spine surgery: a protocol for a randomized controlled trial. BMC musculoskelet Disord 12:239. doi:10.​1186/​1471-2474-12-239 PubMedCrossRef
9.
Zurück zum Zitat Kurtz SM, Steinbeck MJ, Ianuzzi A, van Ooij A, Punt IM, Isaza J, Ross ERS (2009) Retrieval analysis of motion preserving spinal devices and periprosthetic tissues. SAS J 3:161–177CrossRef Kurtz SM, Steinbeck MJ, Ianuzzi A, van Ooij A, Punt IM, Isaza J, Ross ERS (2009) Retrieval analysis of motion preserving spinal devices and periprosthetic tissues. SAS J 3:161–177CrossRef
11.
Zurück zum Zitat Ianuzzi A, Kurtz SM, Kane W, Shah P, Siskey R, van Ooij A, Bindal R, Ross R, Lanman T, Büttner-Janz K, Isaza J (2010) In vivo deformation, surface damage, and biostability of retrieved dynesys systems. Spine 35:E1310–E1316. doi:10.1097/BRS.0b013e3181d6f84f PubMedCrossRef Ianuzzi A, Kurtz SM, Kane W, Shah P, Siskey R, van Ooij A, Bindal R, Ross R, Lanman T, Büttner-Janz K, Isaza J (2010) In vivo deformation, surface damage, and biostability of retrieved dynesys systems. Spine 35:E1310–E1316. doi:10.​1097/​BRS.​0b013e3181d6f84f​ PubMedCrossRef
Metadaten
Titel
Retrieval analysis of PEEK rods for posterior fusion and motion preservation
verfasst von
Steven M. Kurtz
Todd H. Lanman
Genymphas Higgs
Daniel W. MacDonald
Sigurd H. Berven
Jorge E. Isaza
Eual Phillips
Marla J. Steinbeck
Publikationsdatum
01.12.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 12/2013
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-013-2920-4

Weitere Artikel der Ausgabe 12/2013

European Spine Journal 12/2013 Zur Ausgabe

Open Operating Theatre (OOT)

Correction of kyphoscoliosis

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.