Background

Scapular notching is a unique complication of Grammont-style reverse total shoulder arthroplasty. While reverse total shoulder arthroplasty has revolutionized the treatment of pseudoparalysis secondary to cuff tear arthropathy, the implications of scapular notching with regard to patient function and implant stability remain unclear.

Questions/purposes

We reviewed literature to determine the etiology and incidence, radiographic progression and effect on implant stability, relationship with postoperative function, and risk factors for the development of scapular notching.

Methods

We reviewed PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE with the terms “reverse total shoulder arthroplasty” and “scapular notching.” Inclusion criteria were a level of evidence of IV (or better). Twenty-four articles were selected after manual review.

Results

Scapular notching after reverse total shoulder arthroplasty is due to repetitive contact between the polyethylene of the humeral component and the inferior scapular neck during adduction, leading to erosion of the scapular neck, polyethylene wear, joint inflammation, and potential implant loosening. Scapular notching appears between 6 and 14 months postoperatively, with an incidence of 44% to 96%. Radiographic progression and effect on patient function remain controversial. Predictors of scapular notching include surgical approach, glenoid wear, preoperative diagnosis, infraspinatus muscle quality, cranial–caudal positioning, and tilt of the glenosphere.

Conclusions

Improved understanding of the etiology and risk factors for scapular notching will lead to refinement in implant technology and surgical technique that may translate into improved patient function and implant longevity for Grammont-style reverse total shoulder arthroplasty.
Literatur
1.
Zurück zum Zitat Boileau P, Watkinson DJ, Hatzidakis AM, Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14(1 Suppl S):147S–161S.PubMedCrossRef Boileau P, Watkinson DJ, Hatzidakis AM, Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14(1 Suppl S):147S–161S.PubMedCrossRef
2.
Zurück zum Zitat Boulahia A, Edwards TB, Walch G, Baratta RV. Early results of a reverse design prosthesis in the treatment of arthritis of the shoulder in elderly patients with a large rotator cuff tear. Orthopedics. 2002;25:129–133.PubMed Boulahia A, Edwards TB, Walch G, Baratta RV. Early results of a reverse design prosthesis in the treatment of arthritis of the shoulder in elderly patients with a large rotator cuff tear. Orthopedics. 2002;25:129–133.PubMed
3.
Zurück zum Zitat Cuff D, Pupello D, Virani N, Levy J, Frankle M. Reverse shoulder arthroplasty for the treatment of rotator cuff deficiency. J Bone Joint Surg Am. 2008;90:1244–1251.PubMedCrossRef Cuff D, Pupello D, Virani N, Levy J, Frankle M. Reverse shoulder arthroplasty for the treatment of rotator cuff deficiency. J Bone Joint Surg Am. 2008;90:1244–1251.PubMedCrossRef
4.
Zurück zum Zitat Delloye C, Joris D, Colette A, Eudier A, Dubuc JE. Mechanical complications of total shoulder inverted prosthesis [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2002;88:410–414.PubMed Delloye C, Joris D, Colette A, Eudier A, Dubuc JE. Mechanical complications of total shoulder inverted prosthesis [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2002;88:410–414.PubMed
5.
Zurück zum Zitat Edwards TB, Boulahia A, Kempf JF, Boileau P, Nemoz C, Walch G. The influence of rotator cuff disease on the results of shoulder arthroplasty for primary osteoarthritis: results of a multicenter study. J Bone Joint Surg Am. 2002;84:2240–2248.PubMed Edwards TB, Boulahia A, Kempf JF, Boileau P, Nemoz C, Walch G. The influence of rotator cuff disease on the results of shoulder arthroplasty for primary osteoarthritis: results of a multicenter study. J Bone Joint Surg Am. 2002;84:2240–2248.PubMed
6.
Zurück zum Zitat Favard L, Lautman S, Sirveaux F, Oudet D, Kerjean Y, Huguet D. Hemiarthroplasty versus reverse arthroplasty in the treatment of osteoarthritis with massive rotator cuff tear. In: Boileau P, Walch G, Mole D, eds. Protheses d’epaule…recul de 2 a 10 ans. Paris, France: Sauramps Medical; 2001:261–268. Favard L, Lautman S, Sirveaux F, Oudet D, Kerjean Y, Huguet D. Hemiarthroplasty versus reverse arthroplasty in the treatment of osteoarthritis with massive rotator cuff tear. In: Boileau P, Walch G, Mole D, eds. Protheses d’epaule…recul de 2 a 10 ans. Paris, France: Sauramps Medical; 2001:261–268.
7.
Zurück zum Zitat Gerber C, Pennington SD, Nyffeler RW. Reverse total shoulder arthroplasty. J Am Acad Orthop Surg. 2009;17:284–295.PubMed Gerber C, Pennington SD, Nyffeler RW. Reverse total shoulder arthroplasty. J Am Acad Orthop Surg. 2009;17:284–295.PubMed
8.
Zurück zum Zitat Gutierrez S, Greiwe RM, Frankle MA, Siegal S, Lee WE 3rd. Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis. J Shoulder Elbow Surg. 2007;16(3 Suppl):S9–S12.PubMedCrossRef Gutierrez S, Greiwe RM, Frankle MA, Siegal S, Lee WE 3rd. Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis. J Shoulder Elbow Surg. 2007;16(3 Suppl):S9–S12.PubMedCrossRef
9.
Zurück zum Zitat Gutierrez S, Levy JC, Frankle MA, Cuff D, Keller TS, Pupello DR, Lee WE 3rd. Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model. J Shoulder Elbow Surg. 2008;17:608–615.PubMedCrossRef Gutierrez S, Levy JC, Frankle MA, Cuff D, Keller TS, Pupello DR, Lee WE 3rd. Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model. J Shoulder Elbow Surg. 2008;17:608–615.PubMedCrossRef
10.
Zurück zum Zitat Kontaxis A, Johnson GR. The biomechanics of reverse anatomy shoulder replacement—a modeling study. Clin Biomech (Bristol, Avon). 2009;24:254–260.CrossRef Kontaxis A, Johnson GR. The biomechanics of reverse anatomy shoulder replacement—a modeling study. Clin Biomech (Bristol, Avon). 2009;24:254–260.CrossRef
11.
Zurück zum Zitat Levigne C, Boileau P, Favard L, Garaud P, Mole D, Sirveaux F, Walch G. Scapular notching in reverse shoulder arthroplasty. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F, eds. Reverse Shoulder Arthroplasty: Clinical Results, Complications, Revision. Montpellier, France: Sauramps Medical; 2006:353–372. Levigne C, Boileau P, Favard L, Garaud P, Mole D, Sirveaux F, Walch G. Scapular notching in reverse shoulder arthroplasty. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F, eds. Reverse Shoulder Arthroplasty: Clinical Results, Complications, Revision. Montpellier, France: Sauramps Medical; 2006:353–372.
12.
Zurück zum Zitat Nyffeler RW, Werner CM, Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg. 2005;14:524–528.PubMedCrossRef Nyffeler RW, Werner CM, Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg. 2005;14:524–528.PubMedCrossRef
13.
Zurück zum Zitat Nyffeler RW, Werner CM, Simmen BR, Gerber C. Analysis of a retrieved Delta III total shoulder prosthesis. J Bone Joint Surg Br. 2004;86:1187–1191.PubMedCrossRef Nyffeler RW, Werner CM, Simmen BR, Gerber C. Analysis of a retrieved Delta III total shoulder prosthesis. J Bone Joint Surg Br. 2004;86:1187–1191.PubMedCrossRef
14.
Zurück zum Zitat Roche C, Flurin PH, Wright T, Crosby LA, Mauldin M, Zuckerman JD. An evaluation of the relationships between reverse shoulder design parameters and range of motion, impingement, and stability. J Shoulder Elbow Surg. 2009;18:734–741.PubMedCrossRef Roche C, Flurin PH, Wright T, Crosby LA, Mauldin M, Zuckerman JD. An evaluation of the relationships between reverse shoulder design parameters and range of motion, impingement, and stability. J Shoulder Elbow Surg. 2009;18:734–741.PubMedCrossRef
15.
Zurück zum Zitat Seebauer L. Reverse prosthesis through a superior approach for cuff tear arthropathy. Tech Shoulder Elbow Surg. 2006;7:13–26.CrossRef Seebauer L. Reverse prosthesis through a superior approach for cuff tear arthropathy. Tech Shoulder Elbow Surg. 2006;7:13–26.CrossRef
16.
Zurück zum Zitat Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C. Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am. 2007;89:588–600.PubMedCrossRef Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C. Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am. 2007;89:588–600.PubMedCrossRef
17.
Zurück zum Zitat Sirveaux F. A prothese de Grammont dans le traitement des arthropathies de l’epaule a coiffe detruite: a propos d’une serie multi-centrique de 42 cas [thesis]. Nancy, France: Faculté de médecine de Nancy, L’Université de Nancy I; 1997:245. Sirveaux F. A prothese de Grammont dans le traitement des arthropathies de l’epaule a coiffe detruite: a propos d’une serie multi-centrique de 42 cas [thesis]. Nancy, France: Faculté de médecine de Nancy, L’Université de Nancy I; 1997:245.
18.
Zurück zum Zitat Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff: results of a multicentre study of 80 shoulders. J Bone Joint Surg Br. 2004;86:388–395.PubMedCrossRef Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff: results of a multicentre study of 80 shoulders. J Bone Joint Surg Br. 2004;86:388–395.PubMedCrossRef
19.
Zurück zum Zitat Valenti PH, Boutens D, Nerot C. Delta 3 reversed prosthesis for osteoarthritis with massive rotator cuff tear: long term results. In: Boileau P, Walch G, Mole D, eds. Protheses d’epaule…recul de 2 a 10 ans. Paris, France: Sauramps Medical; 2001:253–259. Valenti PH, Boutens D, Nerot C. Delta 3 reversed prosthesis for osteoarthritis with massive rotator cuff tear: long term results. In: Boileau P, Walch G, Mole D, eds. Protheses d’epaule…recul de 2 a 10 ans. Paris, France: Sauramps Medical; 2001:253–259.
20.
Zurück zum Zitat Vanhove B, Beugnies A. Grammont’s reverse shoulder prosthesis for rotator cuff arthropathy: a retrospective study of 32 cases. Acta Orthop Belg. 2004;70:219–225.PubMed Vanhove B, Beugnies A. Grammont’s reverse shoulder prosthesis for rotator cuff arthropathy: a retrospective study of 32 cases. Acta Orthop Belg. 2004;70:219–225.PubMed
21.
Zurück zum Zitat Wall B, Nove-Josserand L, O’Connor DP, Edwards TB, Walch G. Reverse total shoulder arthroplasty: a review of results according to etiology. J Bone Joint Surg Am. 2007;89:1476–1485.PubMedCrossRef Wall B, Nove-Josserand L, O’Connor DP, Edwards TB, Walch G. Reverse total shoulder arthroplasty: a review of results according to etiology. J Bone Joint Surg Am. 2007;89:1476–1485.PubMedCrossRef
22.
Zurück zum Zitat Werner CM, Steinmann PA, Gilbart M, Gerber C. Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. J Bone Joint Surg Am. 2005;87:1476–1486.PubMedCrossRef Werner CM, Steinmann PA, Gilbart M, Gerber C. Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. J Bone Joint Surg Am. 2005;87:1476–1486.PubMedCrossRef
23.
Zurück zum Zitat Wiater JM, Fabing MH. Shoulder arthroplasty: prosthetic options and indications. J Am Acad Orthop Surg. 2009;17:415–425.PubMed Wiater JM, Fabing MH. Shoulder arthroplasty: prosthetic options and indications. J Am Acad Orthop Surg. 2009;17:415–425.PubMed
24.
Zurück zum Zitat Wierks C, Skolasky RL, Ji JH, McFarland EG. Reverse total shoulder replacement: intraoperative and early postoperative complications. Clin Orthop Relat Res. 2009;467:225–234.PubMedCrossRef Wierks C, Skolasky RL, Ji JH, McFarland EG. Reverse total shoulder replacement: intraoperative and early postoperative complications. Clin Orthop Relat Res. 2009;467:225–234.PubMedCrossRef
Metadaten
Titel
Scapular Notching: Recognition and Strategies to Minimize Clinical Impact
verfasst von
Gregory P. Nicholson, MD
Eric J. Strauss, MD
Seth L. Sherman, MD
Publikationsdatum
01.09.2011
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 9/2011
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-010-1720-y

Weitere Artikel der Ausgabe 9/2011

Clinical Orthopaedics and Related Research® 9/2011 Zur Ausgabe

Symposium: Reverse Total Shoulder Arthroplasty

How Reverse Shoulder Arthroplasty Works

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.