Skip to main content
Erschienen in: Journal of Medical Systems 3/2012

01.06.2012 | ORIGINAL PAPER

Singular Value Decomposition Based Feature Extraction Technique for Physiological Signal Analysis

verfasst von: Cheng-Ding Chang, Chien-Chih Wang, Bernard C. Jiang

Erschienen in: Journal of Medical Systems | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Multiscale entropy (MSE) is one of the popular techniques to calculate and describe the complexity of the physiological signal. Many studies use this approach to detect changes in the physiological conditions in the human body. However, MSE results are easily affected by noise and trends, leading to incorrect estimation of MSE values. In this paper, singular value decomposition (SVD) is adopted to replace MSE to extract the features of physiological signals, and adopt the support vector machine (SVM) to classify the different physiological states. A test data set based on the PhysioNet website was used, and the classification results showed that using SVD to extract features of the physiological signal could attain a classification accuracy rate of 89.157%, which is higher than that using the MSE value (71.084%). The results show the proposed analysis procedure is effective and appropriate for distinguishing different physiological states. This promising result could be used as a reference for doctors in diagnosis of congestive heart failure (CHF) disease.
Literatur
1.
Zurück zum Zitat Costa, M., Goldberger, A. L., Peng, C. K., Multiscale entropy analysis of complex physiologic time series. Phys. Rev. Let. 89(6):068102(1–4), 2002. Costa, M., Goldberger, A. L., Peng, C. K., Multiscale entropy analysis of complex physiologic time series. Phys. Rev. Let. 89(6):068102(1–4), 2002.
2.
Zurück zum Zitat Ferrario, M., Signorini, M. G., Magenes, G., and Cerutti, S., Comparison of entropy-based regularity estimators: Application to the fetal heart rate signal for the identification of fetal distress. IEEE Trans Biomed Eng 53(1):119–125, 2006.CrossRef Ferrario, M., Signorini, M. G., Magenes, G., and Cerutti, S., Comparison of entropy-based regularity estimators: Application to the fetal heart rate signal for the identification of fetal distress. IEEE Trans Biomed Eng 53(1):119–125, 2006.CrossRef
3.
Zurück zum Zitat Patrick, R. N., Anderson, S. M., Jenkins, J. M., Williams, A. E., and Morris, J. A., Jr., Heart rate multiscale entropy at three hours predicts hospital mortality in 3,154 trauma patient. Shock 30(1):17–22, 2008.CrossRef Patrick, R. N., Anderson, S. M., Jenkins, J. M., Williams, A. E., and Morris, J. A., Jr., Heart rate multiscale entropy at three hours predicts hospital mortality in 3,154 trauma patient. Shock 30(1):17–22, 2008.CrossRef
4.
Zurück zum Zitat Hung, C. H., and Jiang, B. C., Multi-scale entropy approach to physiological fatigue during long-term web browsing. Hum Factors Ergon Manuf 19(5):478–493, 2009.CrossRef Hung, C. H., and Jiang, B. C., Multi-scale entropy approach to physiological fatigue during long-term web browsing. Hum Factors Ergon Manuf 19(5):478–493, 2009.CrossRef
5.
Zurück zum Zitat Trunkvalterova, Z., Javorka, M., Tonhajzerova, I., Javorkova, J., Lazarova, Z., Javorka, K., and Baumert, M., Reduced short-term complexity of heart rate and blood pressure dynamic in patients with diabetes mellitus type 1: Multiscale entropy analysis. Physiol Meas 29:817–828, 2008.CrossRef Trunkvalterova, Z., Javorka, M., Tonhajzerova, I., Javorkova, J., Lazarova, Z., Javorka, K., and Baumert, M., Reduced short-term complexity of heart rate and blood pressure dynamic in patients with diabetes mellitus type 1: Multiscale entropy analysis. Physiol Meas 29:817–828, 2008.CrossRef
6.
Zurück zum Zitat Park, J. H., Kim, S., Kim, C. H., Cichocki, A., and Kim, K., Multiscale entropy analysis of EEG from patients under different pathological conditions. Fractals 15(4):399–404, 2007.CrossRef Park, J. H., Kim, S., Kim, C. H., Cichocki, A., and Kim, K., Multiscale entropy analysis of EEG from patients under different pathological conditions. Fractals 15(4):399–404, 2007.CrossRef
7.
Zurück zum Zitat Costa, M., Peng, C. K., Goldberger, A. L., and Hausdorff, J. M., Multiscale entropy analysis of human gait dynamics. Physica. A, Statistical mechanics and its applications 330(1–2):53–60, 2003.MATHCrossRef Costa, M., Peng, C. K., Goldberger, A. L., and Hausdorff, J. M., Multiscale entropy analysis of human gait dynamics. Physica. A, Statistical mechanics and its applications 330(1–2):53–60, 2003.MATHCrossRef
8.
Zurück zum Zitat Valencia, J. F., Porta, A., Vallverdú, M., Clarià, F., Baranowski, R., Orłowska-Baranowska, E., and Caminal, P., Refined multiscale entropy: Application to 24-h holter recordings of heart period variability in healthy and aortic stenosis subjects. IEEE Trans Biomed Eng 45(9):2202–2213, 2009.CrossRef Valencia, J. F., Porta, A., Vallverdú, M., Clarià, F., Baranowski, R., Orłowska-Baranowska, E., and Caminal, P., Refined multiscale entropy: Application to 24-h holter recordings of heart period variability in healthy and aortic stenosis subjects. IEEE Trans Biomed Eng 45(9):2202–2213, 2009.CrossRef
9.
Zurück zum Zitat McNames J., Thong T., Aboy M. Impulse rejection filter for artifact removal in spectral analysis of biomedical signals. Proceedings of the 26th Annual International Conference of the IEEE EMBS, 145–148, September 1–5 2004 McNames J., Thong T., Aboy M. Impulse rejection filter for artifact removal in spectral analysis of biomedical signals. Proceedings of the 26th Annual International Conference of the IEEE EMBS, 145–148, September 1–5 2004
10.
Zurück zum Zitat Kanjilal, P. P., Palit, S., and Saha, G., Fetal ECG extraction from single-channel maternal ECG using singular value decomposition. IEEE Trans Biomed Eng 44(1):51–59, 1997.CrossRef Kanjilal, P. P., Palit, S., and Saha, G., Fetal ECG extraction from single-channel maternal ECG using singular value decomposition. IEEE Trans Biomed Eng 44(1):51–59, 1997.CrossRef
11.
Zurück zum Zitat Ayat, M., Assaleh, K., and Nashash, H., Fetal ECG extraction from a single abdominal ECG signal using SVD and polynomial classifiers. IEEE Workshop on Machine Learning for Signal Processing, Cancun, Mexico, 2008. Ayat, M., Assaleh, K., and Nashash, H., Fetal ECG extraction from a single abdominal ECG signal using SVD and polynomial classifiers. IEEE Workshop on Machine Learning for Signal Processing, Cancun, Mexico, 2008.
12.
Zurück zum Zitat Moor, B. D., The singular value decomposition and long and short spaces of noisy matrices. IEEE Trans Signal Process 41(9):2826–2838, 1993.MATHCrossRef Moor, B. D., The singular value decomposition and long and short spaces of noisy matrices. IEEE Trans Signal Process 41(9):2826–2838, 1993.MATHCrossRef
15.
Zurück zum Zitat Huang, N. E., Wu, M. C., Long, S. R., Shen, S. S. P., Qu, W., Gloersen, P., and Fan, K. L., A confidence limit for the empirical mode decomposition and hilbert spectrum analysis. Proc R Soc Lond A 459:2317–2345, 2003.MathSciNetMATHCrossRef Huang, N. E., Wu, M. C., Long, S. R., Shen, S. S. P., Qu, W., Gloersen, P., and Fan, K. L., A confidence limit for the empirical mode decomposition and hilbert spectrum analysis. Proc R Soc Lond A 459:2317–2345, 2003.MathSciNetMATHCrossRef
Metadaten
Titel
Singular Value Decomposition Based Feature Extraction Technique for Physiological Signal Analysis
verfasst von
Cheng-Ding Chang
Chien-Chih Wang
Bernard C. Jiang
Publikationsdatum
01.06.2012
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 3/2012
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9636-3

Weitere Artikel der Ausgabe 3/2012

Journal of Medical Systems 3/2012 Zur Ausgabe