Small animal PET: aspects of performance assessment

verfasst von: Simone Weber, Andreas Bauer

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 11/2004

Einloggen, um Zugang zu erhalten

Abstract

Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET.
Literatur
1.
Zurück zum Zitat Tournai MP, Jaszcak RJ, Turkington TG, Coleman RE. Small-animal PET: advent of a new era of PET research. J Nucl Med 1999;40:1176–8.PubMed Tournai MP, Jaszcak RJ, Turkington TG, Coleman RE. Small-animal PET: advent of a new era of PET research. J Nucl Med 1999;40:1176–8.PubMed
2.
Zurück zum Zitat Cherry SR. Fundamentals of positron emission tomography and applications in preclinical drug development. J Clin Pharmacol 2001;41:482–91.CrossRefPubMed Cherry SR. Fundamentals of positron emission tomography and applications in preclinical drug development. J Clin Pharmacol 2001;41:482–91.CrossRefPubMed
3.
Zurück zum Zitat Chatziioannou AF. Molecular imaging of small animals with dedicated PET tomographs. Eur J Nucl Med Mol Imaging 2002;29:98–114.CrossRefPubMed Chatziioannou AF. Molecular imaging of small animals with dedicated PET tomographs. Eur J Nucl Med Mol Imaging 2002;29:98–114.CrossRefPubMed
5.
Zurück zum Zitat Hume SP, Myers R. Dedicated small animal scanners: a new tool for drug development? Curr Pharm Design 2002;8:1497–511. Hume SP, Myers R. Dedicated small animal scanners: a new tool for drug development? Curr Pharm Design 2002;8:1497–511.
6.
Zurück zum Zitat Karp JS, Daube-Witherspoon ME, Hoffman EJ, et al. Performance standards in positron emission tomography. J Nucl Med 1991;32:2342–50.PubMed Karp JS, Daube-Witherspoon ME, Hoffman EJ, et al. Performance standards in positron emission tomography. J Nucl Med 1991;32:2342–50.PubMed
7.
Zurück zum Zitat National Electrical Manufacturers Association. NEMA Standards Publication NU 2-1994: performance measurements of positron emission tomographs. Washington: National Electrical Manufacturers Association; 1994. National Electrical Manufacturers Association. NEMA Standards Publication NU 2-1994: performance measurements of positron emission tomographs. Washington: National Electrical Manufacturers Association; 1994.
8.
Zurück zum Zitat Daube-Witherspoon ME, Karp JE, Casey ME, et al. PET performance measurements using the NEMA NU 2-2001 standard. J Nucl Med 2002;43:1398–409.PubMed Daube-Witherspoon ME, Karp JE, Casey ME, et al. PET performance measurements using the NEMA NU 2-2001 standard. J Nucl Med 2002;43:1398–409.PubMed
9.
Zurück zum Zitat National Electrical Manufacturers Association. NEMA Standards Publication NU 2-2001: performance measurements of positron emission tomographs. Rosslyn: National Electrical Manufacturers Association; 2001. National Electrical Manufacturers Association. NEMA Standards Publication NU 2-2001: performance measurements of positron emission tomographs. Rosslyn: National Electrical Manufacturers Association; 2001.
10.
Zurück zum Zitat Tai YC, Chatziioannou A, Siegel S, et al. Performance evaluation of the microPET P4: a PET system dedicated to animal imaging. Phys Med Biol 2001;46:1845–62.CrossRefPubMed Tai YC, Chatziioannou A, Siegel S, et al. Performance evaluation of the microPET P4: a PET system dedicated to animal imaging. Phys Med Biol 2001;46:1845–62.CrossRefPubMed
11.
Zurück zum Zitat Knoess C, Siegel S, Smith A, et al. Performance evaluation of the microPET R4 scanner for rodents. Eur J Nucl Med Mol Imaging 2003;30:737–47.PubMed Knoess C, Siegel S, Smith A, et al. Performance evaluation of the microPET R4 scanner for rodents. Eur J Nucl Med Mol Imaging 2003;30:737–47.PubMed
12.
Zurück zum Zitat Jeavons AP, Chandler RA, Dettmar CAR. A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals. IEEE Trans Nucl Sci 1999;46:468–73.CrossRef Jeavons AP, Chandler RA, Dettmar CAR. A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals. IEEE Trans Nucl Sci 1999;46:468–73.CrossRef
13.
Zurück zum Zitat Missimer J, Madi Z, Honer M, Keller C, Schubiger A, Ametamey SM. Performance evaluation of the 16-module quad-HIDAC small animal PET camera. Phys Med Biol 2004;49:2069–81.CrossRefPubMed Missimer J, Madi Z, Honer M, Keller C, Schubiger A, Ametamey SM. Performance evaluation of the 16-module quad-HIDAC small animal PET camera. Phys Med Biol 2004;49:2069–81.CrossRefPubMed
14.
Zurück zum Zitat Bloomfield PM, Rajeswaran S, Spinks TJ, et al. The design and physical characteristics of a small animal positron emission tomograph. Phys Med Biol 1995;40:1105–26.CrossRefPubMed Bloomfield PM, Rajeswaran S, Spinks TJ, et al. The design and physical characteristics of a small animal positron emission tomograph. Phys Med Biol 1995;40:1105–26.CrossRefPubMed
15.
Zurück zum Zitat Bloomfield PM, Myers R, Hume SP, et al. Three-dimensional performance of a small-diameter positron emission tomograph. Phys Med Biol 1997;42:389–400.CrossRefPubMed Bloomfield PM, Myers R, Hume SP, et al. Three-dimensional performance of a small-diameter positron emission tomograph. Phys Med Biol 1997;42:389–400.CrossRefPubMed
16.
Zurück zum Zitat Watanabe M, Okada H, Shimizu K, et al. A high resolution animal PET scanner using compact PS-PMT detectors. IEEE Trans Nucl Sci 1997;44:1277–82.CrossRef Watanabe M, Okada H, Shimizu K, et al. A high resolution animal PET scanner using compact PS-PMT detectors. IEEE Trans Nucl Sci 1997;44:1277–82.CrossRef
17.
Zurück zum Zitat Weber S, Herzog H, Cremer M, et al. Evaluation of the TierPET system. IEEE Trans Nucl Sci 1999;46:1177–83.CrossRef Weber S, Herzog H, Cremer M, et al. Evaluation of the TierPET system. IEEE Trans Nucl Sci 1999;46:1177–83.CrossRef
18.
Zurück zum Zitat Weber S, Bauer A, Herzog H, et al. Recent results of the TierPET scanner. IEEE Trans Nucl Sci 2000;47:1665–9.CrossRef Weber S, Bauer A, Herzog H, et al. Recent results of the TierPET scanner. IEEE Trans Nucl Sci 2000;47:1665–9.CrossRef
19.
Zurück zum Zitat Ziegler SI, Pichler BJ, Boening G, et al. A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals. Eur J Nucl Med 2001;28:136–43.CrossRefPubMed Ziegler SI, Pichler BJ, Boening G, et al. A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals. Eur J Nucl Med 2001;28:136–43.CrossRefPubMed
20.
Zurück zum Zitat Siegel S, Vaquero JJ, Aloj L, et al. Initial results from a PET/planar small animal imaging system. IEEE Trans Nucl Sci 1999;46:571–5.CrossRef Siegel S, Vaquero JJ, Aloj L, et al. Initial results from a PET/planar small animal imaging system. IEEE Trans Nucl Sci 1999;46:571–5.CrossRef
21.
Zurück zum Zitat Lecomte R, Cadorette J, Rodrigue S, et al. Initial results from the Sherbrooke avalanche photodiode positron tomograph. IEEE Trans Nucl Sci 1996;43:1952–7.CrossRef Lecomte R, Cadorette J, Rodrigue S, et al. Initial results from the Sherbrooke avalanche photodiode positron tomograph. IEEE Trans Nucl Sci 1996;43:1952–7.CrossRef
22.
Zurück zum Zitat Bruyndonckx P, Liu X, Tavernier S, Zhang S. Performance study of a 3D small animal PET scanner based on BaF2 crystals and a photo sensitive wire chamber. Nucl Instrum Methods A 1997;392:407–13.CrossRef Bruyndonckx P, Liu X, Tavernier S, Zhang S. Performance study of a 3D small animal PET scanner based on BaF2 crystals and a photo sensitive wire chamber. Nucl Instrum Methods A 1997;392:407–13.CrossRef
23.
Zurück zum Zitat Chatziioannou AF, Cherry S, Shao Y, et al. Performance evaluation of microPET: a high resolution lutetium oxyorthosilicate PET scanner for animal imaging. J Nucl Med 1999;40:1164–75.PubMed Chatziioannou AF, Cherry S, Shao Y, et al. Performance evaluation of microPET: a high resolution lutetium oxyorthosilicate PET scanner for animal imaging. J Nucl Med 1999;40:1164–75.PubMed
24.
Zurück zum Zitat Di Domenico G, Motta A, Zavattini G, et al. Characterization of the Ferrara animal PET scanner. Nucl Instrum Methods A 2002;477:505–508. Di Domenico G, Motta A, Zavattini G, et al. Characterization of the Ferrara animal PET scanner. Nucl Instrum Methods A 2002;477:505–508.
25.
Zurück zum Zitat Bruyndonckx P, Xuan L, Rajeswaran S, Smolik W, Tavernier S, Shuping Z. Design and physical characteristics of a small animal PET using BaF2 crystals and a photosensitive wire chamber. Nucl Instrum Methods A 1996;382:589–600.CrossRef Bruyndonckx P, Xuan L, Rajeswaran S, Smolik W, Tavernier S, Shuping Z. Design and physical characteristics of a small animal PET using BaF2 crystals and a photosensitive wire chamber. Nucl Instrum Methods A 1996;382:589–600.CrossRef
26.
Zurück zum Zitat Kinahan PE, Rogers JG. Analytic 3D image reconstruction using all detected events. IEEE Trans Nucl Sci 1989;36:964–8.CrossRef Kinahan PE, Rogers JG. Analytic 3D image reconstruction using all detected events. IEEE Trans Nucl Sci 1989;36:964–8.CrossRef
27.
Zurück zum Zitat Defrise M, Kinahan P. Data acquisition and image reconstruction for 3D PET. In: Bendriem B, Townsend DW, editors. The theory and practice of 3D PET. Dordrecht: Kluwer Academic; 1998. p 11–53. Defrise M, Kinahan P. Data acquisition and image reconstruction for 3D PET. In: Bendriem B, Townsend DW, editors. The theory and practice of 3D PET. Dordrecht: Kluwer Academic; 1998. p 11–53.
28.
Zurück zum Zitat Defrise M, Kinahan PE, Townsend D, Michel C, Sibomana M, Newport DF. Exact and approximate rebinning algorithms for 3-D PET data. IEEE Trans Med Imaging 1997;16:145–58.CrossRefPubMed Defrise M, Kinahan PE, Townsend D, Michel C, Sibomana M, Newport DF. Exact and approximate rebinning algorithms for 3-D PET data. IEEE Trans Med Imaging 1997;16:145–58.CrossRefPubMed
29.
Zurück zum Zitat Liow JS, Strother SC. The convergence of object-dependent resolution in maximum likelihood based tomographic resolution. Phys Med Biol 1993;38:55–70.CrossRefPubMed Liow JS, Strother SC. The convergence of object-dependent resolution in maximum likelihood based tomographic resolution. Phys Med Biol 1993;38:55–70.CrossRefPubMed
30.
Zurück zum Zitat Bailey DL, Jones T, Spinks TJ. A method for measuring the absolute sensitivity of positron emission tomographic scanners. Eur J Nucl Med 1991;18:374–9.CrossRefPubMed Bailey DL, Jones T, Spinks TJ. A method for measuring the absolute sensitivity of positron emission tomographic scanners. Eur J Nucl Med 1991;18:374–9.CrossRefPubMed
31.
Zurück zum Zitat Strother SC, Casey ME, Hoffman EJ. Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalent counts. IEEE Trans Nucl Sci 1990;37:783–8.CrossRef Strother SC, Casey ME, Hoffman EJ. Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalent counts. IEEE Trans Nucl Sci 1990;37:783–8.CrossRef
32.
Zurück zum Zitat Badawi RD, Marsden PK, Cronin BF, Sutcliffe JL, Maisey MN. Optimization of noise-equivalent count rates in 3D PET. Phys Med Biol 1996;41:1755–76.CrossRefPubMed Badawi RD, Marsden PK, Cronin BF, Sutcliffe JL, Maisey MN. Optimization of noise-equivalent count rates in 3D PET. Phys Med Biol 1996;41:1755–76.CrossRefPubMed
33.
Zurück zum Zitat Melcher CL, Schweitzer JS. Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator. IEEE Trans Nucl Sci 1992;39:502–5.CrossRef Melcher CL, Schweitzer JS. Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator. IEEE Trans Nucl Sci 1992;39:502–5.CrossRef
34.
Zurück zum Zitat Reader AJ, Allay S, Bakatselos F, et al. One-pass list-mode EM algorithm for high resolution 3D PET image reconstruction into large arrays. IEEE Trans Nucl Sci 2002;49:693–9.CrossRef Reader AJ, Allay S, Bakatselos F, et al. One-pass list-mode EM algorithm for high resolution 3D PET image reconstruction into large arrays. IEEE Trans Nucl Sci 2002;49:693–9.CrossRef
35.
Zurück zum Zitat Myers R, Hume S, Bloomfield P, Jones T. Radio-imaging in small animals. J Psychopharmacol 1999;13:352–7.PubMed Myers R, Hume S, Bloomfield P, Jones T. Radio-imaging in small animals. J Psychopharmacol 1999;13:352–7.PubMed
36.
Zurück zum Zitat Myers R. The biological application of small animal PET imaging. Nucl Med Biol 2001;28:585–93.CrossRefPubMed Myers R. The biological application of small animal PET imaging. Nucl Med Biol 2001;28:585–93.CrossRefPubMed
37.
Zurück zum Zitat Cherry SR. Fundamentals of positron emission tomography and applications in preclinical drug development. J Clin Pharmacol 2001;41:482–91.CrossRefPubMed Cherry SR. Fundamentals of positron emission tomography and applications in preclinical drug development. J Clin Pharmacol 2001;41:482–91.CrossRefPubMed
38.
Zurück zum Zitat Rowland DJ, Lewis JS, Welch MJ. Molecular imaging: the application of small animal positron emission tomography. J Cell Biochem 2002;39(Suppl):110–5.CrossRef Rowland DJ, Lewis JS, Welch MJ. Molecular imaging: the application of small animal positron emission tomography. J Cell Biochem 2002;39(Suppl):110–5.CrossRef
39.
Zurück zum Zitat Herschman HR. Micro-PET imaging and small animal models of disease. Curr Opin Immunol 2003;15:378–84.CrossRefPubMed Herschman HR. Micro-PET imaging and small animal models of disease. Curr Opin Immunol 2003;15:378–84.CrossRefPubMed
40.
Zurück zum Zitat Hume SP, Gunn RN, Jones T. Pharmacological constraints associated with positron emission tomographic scanning of small laboratory animals. Eur J Nucl Med 1998;25:173–6.CrossRefPubMed Hume SP, Gunn RN, Jones T. Pharmacological constraints associated with positron emission tomographic scanning of small laboratory animals. Eur J Nucl Med 1998;25:173–6.CrossRefPubMed
41.
Zurück zum Zitat Phelps ME, Hoffman EJ, Huang SC, Ter-Pogossian M. Effect of positron range on spatial resolution. J Nucl Med 1975;16:649–52.PubMed Phelps ME, Hoffman EJ, Huang SC, Ter-Pogossian M. Effect of positron range on spatial resolution. J Nucl Med 1975;16:649–52.PubMed
42.
Zurück zum Zitat Cho ZH, Chan JK, Ericksson L, et al. Positron ranges obtained from biomedically important positron-emitting radionuclides. J Nucl Med 1975;16:1174–6.PubMed Cho ZH, Chan JK, Ericksson L, et al. Positron ranges obtained from biomedically important positron-emitting radionuclides. J Nucl Med 1975;16:1174–6.PubMed
43.
Zurück zum Zitat Derenzo SE. Precision measurement of annihilation point spread distributions for medically important positron emitters. In: Hasiguti RR, Fujiwara K, editors. Positron annihilation. Sendai: The Japan Institute of Metals; 1979. p 819–23. Derenzo SE. Precision measurement of annihilation point spread distributions for medically important positron emitters. In: Hasiguti RR, Fujiwara K, editors. Positron annihilation. Sendai: The Japan Institute of Metals; 1979. p 819–23.
44.
Zurück zum Zitat Palmer RP, Brownell GL. Annihilation density distribution calculations for medically important positron emitters. IEEE Trans Med Imaging 1992;11:373–8.CrossRef Palmer RP, Brownell GL. Annihilation density distribution calculations for medically important positron emitters. IEEE Trans Med Imaging 1992;11:373–8.CrossRef
45.
Zurück zum Zitat Sanchez-Crespo A, Andreo P, Larsson SA. Positron flight in human tissues and its influence on PET image spatial resolution. Eur J Nucl Med Mol Imaging 2004;31:44–51.CrossRefPubMed Sanchez-Crespo A, Andreo P, Larsson SA. Positron flight in human tissues and its influence on PET image spatial resolution. Eur J Nucl Med Mol Imaging 2004;31:44–51.CrossRefPubMed
46.
Zurück zum Zitat Levin CS, Hoffman EJ. Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution. Phys Med Biol 1999;44:781–99.CrossRefPubMed Levin CS, Hoffman EJ. Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution. Phys Med Biol 1999;44:781–99.CrossRefPubMed
47.
Zurück zum Zitat Laforest R, Rowland DJ, Welch MJ. microPET imaging with nonconventional isotopes. IEEE Trans Nucl Sci 2002;49:2119–26.CrossRef Laforest R, Rowland DJ, Welch MJ. microPET imaging with nonconventional isotopes. IEEE Trans Nucl Sci 2002;49:2119–26.CrossRef
Metadaten
Titel
Small animal PET: aspects of performance assessment
verfasst von
Simone Weber
Andreas Bauer
Publikationsdatum
01.11.2004
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 11/2004
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-004-1683-x

Weitere Artikel der Ausgabe 11/2004

European Journal of Nuclear Medicine and Molecular Imaging 11/2004 Zur Ausgabe

News & Views

November 2004