Skip to main content
Erschienen in: Journal of Nephrology 3/2019

01.06.2019 | Original Article

Sodium removal and plasma tonicity balance are not different in hemodialysis and hemodiafiltration using high-flux membranes

verfasst von: Vincenzo La Milia, Chiara Ravasi, Fabio Carfagna, Elena Alberghini, Ivano Baragetti, Laura Buzzi, Francesca Ferrario, Silvia Furiani, Gaia Santagostino Barbone, Giuseppe Pontoriero

Erschienen in: Journal of Nephrology | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Background

The clinical benefits of on-line hemodiafiltration (HDF) versus high-flux membranes hemodialysis (hf-HD) are still debated. In fact, although a superiority of one treatment over the other, especially in terms of mortality, did not emerge from the analysis of clinical trials, improved intradialytic vascular stability and cardiovascular mortality have been observed in patients undergoing HDF rather than hf-HD; the lower removal of sodium (Na+) during HDF seems to play a major role. The plasma concentration of Na+ is the major determinant of plasma tonicity, which, by determining the flow of water between the intracellular and the extracellular compartment, contributes to the vascular refilling process and the maintenance of blood pressure during the hemodialysis treatment. Plasma tonicity also depends on plasma glucose concentration, especially in patients with diabetes mellitus with hyperglycaemia at the start of hemodialysis treatment.

Materials and methods

We evaluated the removal of Na+ and plasma tonicity balance during a 2-week period by performing 2–3 consecutive sessions of hf-HD followed by 2–3 consecutive sessions of HDF, or vice versa, in 47 patients (40% diabetics) on chronic hemodialysis. Identical parameters were used in all dialytic sessions.

Results

Na+ removal per session was − 224 ± 144 mmol and − 219 ± 152 mmol, respectively, in hf-HD and in HDF (p = 0.79). The plasma tonicity balance per session was − 575 ± 310 mOsm and − 563 ± 328 mOsm, respectively, in hf-HD and in HDF (p = 0.75).

Conclusions

The removal of Na+ and plasma tonicity balance did not differ between hf-HD and HDF. This observation suggests that factors other than those assessed in our study might explain the improved cardiovascular stability reported in HDF.
Literatur
1.
Zurück zum Zitat Grooteman MP, van den Dorpel MA, Bots ML et al (2012) Effect of online hemodiafiltration on all-cause mortality and cardiovascular outcomes. J Am Soc Nephrol 23(6):1087–1096CrossRef Grooteman MP, van den Dorpel MA, Bots ML et al (2012) Effect of online hemodiafiltration on all-cause mortality and cardiovascular outcomes. J Am Soc Nephrol 23(6):1087–1096CrossRef
2.
Zurück zum Zitat Ok E, Asci G, Toz H et al (2013) Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: results from the Turkish OL-HDF study. Nephrol Dial Transpl 28(1):192–202CrossRef Ok E, Asci G, Toz H et al (2013) Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: results from the Turkish OL-HDF study. Nephrol Dial Transpl 28(1):192–202CrossRef
3.
Zurück zum Zitat Maduell F, Moreso F, Pons M et al (2013) High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients. J Am Soc Nephrol 24(3):487–497CrossRef Maduell F, Moreso F, Pons M et al (2013) High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients. J Am Soc Nephrol 24(3):487–497CrossRef
4.
Zurück zum Zitat Morena M, Jaussent A, Chalabi L et al (2017) Treatment tolerance and patient-reported outcomes favor online hemodiafiltration compared to high-flux hemodialysis in the elderly. Kidney Int 91(6):1495–1509CrossRef Morena M, Jaussent A, Chalabi L et al (2017) Treatment tolerance and patient-reported outcomes favor online hemodiafiltration compared to high-flux hemodialysis in the elderly. Kidney Int 91(6):1495–1509CrossRef
5.
Zurück zum Zitat Wang AY, Ninomiya T, Al-Kahwa A et al (2014) Effect of hemodiafiltration or hemofiltration compared with hemodialysis on mortality and cardiovascular disease in chronic kidney failure: a systematic review and meta-analysis of randomized trials. Am J Kidney Dis 63(6):968–978CrossRef Wang AY, Ninomiya T, Al-Kahwa A et al (2014) Effect of hemodiafiltration or hemofiltration compared with hemodialysis on mortality and cardiovascular disease in chronic kidney failure: a systematic review and meta-analysis of randomized trials. Am J Kidney Dis 63(6):968–978CrossRef
6.
Zurück zum Zitat Nistor I, Palmer SC, Craig JC et al (2014) Convective versus diffusive dialysis therapies for chronic kidney failure: an updated systematic review of randomized controlled trials. Am J Kidney Dis 63(6):954–967CrossRef Nistor I, Palmer SC, Craig JC et al (2014) Convective versus diffusive dialysis therapies for chronic kidney failure: an updated systematic review of randomized controlled trials. Am J Kidney Dis 63(6):954–967CrossRef
7.
Zurück zum Zitat Susantitaphong P, Siribamrungwong M, Jaber BL (2013) Convective therapies versus low-flux hemodialysis for chronic kidney failure: a meta-analysis of randomized controlled trials. Nephrol Dial Transpl 28(11):2859–2874CrossRef Susantitaphong P, Siribamrungwong M, Jaber BL (2013) Convective therapies versus low-flux hemodialysis for chronic kidney failure: a meta-analysis of randomized controlled trials. Nephrol Dial Transpl 28(11):2859–2874CrossRef
8.
Zurück zum Zitat Mostovaya IM, Blankestijn PJ, Bots ML et al (2014) Clinical evidence on hemodiafiltration: a systematic review and a meta-analysis. Semin Dial 27(2):119–127CrossRef Mostovaya IM, Blankestijn PJ, Bots ML et al (2014) Clinical evidence on hemodiafiltration: a systematic review and a meta-analysis. Semin Dial 27(2):119–127CrossRef
9.
Zurück zum Zitat Panichi V, Rocchetti MT, Scatena A et al (2017) Long term variation of serum levels of uremic toxins in patients treated by post-dilution high volume on-line hemodiafiltration in comparison to standard low-flux bicarbonate dialysis: results from the REDERT study. J Nephrol 30(4):583–591CrossRef Panichi V, Rocchetti MT, Scatena A et al (2017) Long term variation of serum levels of uremic toxins in patients treated by post-dilution high volume on-line hemodiafiltration in comparison to standard low-flux bicarbonate dialysis: results from the REDERT study. J Nephrol 30(4):583–591CrossRef
10.
Zurück zum Zitat Basile C, Davenport A, Blankestijn PJ (2017) Why choose high volume online post-dilution hemodiafiltration? J Nephrol 30(2):181–186CrossRef Basile C, Davenport A, Blankestijn PJ (2017) Why choose high volume online post-dilution hemodiafiltration? J Nephrol 30(2):181–186CrossRef
11.
Zurück zum Zitat Mion M, Kerr PG, Argiles A et al (1992) Haemodiafiltration in high-cardiovascular-risk patients. Nephrol Dial Transpl 7(5):453–454 Mion M, Kerr PG, Argiles A et al (1992) Haemodiafiltration in high-cardiovascular-risk patients. Nephrol Dial Transpl 7(5):453–454
12.
Zurück zum Zitat Pizzarelli F, Cerrai T, Dattolo P et al (1998) Convective treatments with on-line production of replacement fluid: a clinical experience lasting 6 years. Nephrol Dial Transpl 13(2):363–369CrossRef Pizzarelli F, Cerrai T, Dattolo P et al (1998) Convective treatments with on-line production of replacement fluid: a clinical experience lasting 6 years. Nephrol Dial Transpl 13(2):363–369CrossRef
13.
Zurück zum Zitat Maduell F, del Pozo C, Garcia H et al (1999) Change from conventional haemodiafiltration to on-line haemodiafiltration. Nephrol Dial Transpl 14(5):1202–1207CrossRef Maduell F, del Pozo C, Garcia H et al (1999) Change from conventional haemodiafiltration to on-line haemodiafiltration. Nephrol Dial Transpl 14(5):1202–1207CrossRef
14.
Zurück zum Zitat Locatelli F, Altieri P, Andrulli S et al (2010) Hemofiltration and hemodiafiltration reduce intradialytic hypotension in ESRD. J Am Soc Nephrol 21(10):1798–1807CrossRef Locatelli F, Altieri P, Andrulli S et al (2010) Hemofiltration and hemodiafiltration reduce intradialytic hypotension in ESRD. J Am Soc Nephrol 21(10):1798–1807CrossRef
15.
Zurück zum Zitat Pedrini LA, Ponti R, Faranna P et al (1991) Sodium modeling in hemodiafiltration. Kidney Int 40(3):525–532CrossRef Pedrini LA, Ponti R, Faranna P et al (1991) Sodium modeling in hemodiafiltration. Kidney Int 40(3):525–532CrossRef
16.
Zurück zum Zitat In: Narins RGE (ed) (1994) Maxwell and Kleeman’s clinical disorders of fluid and electrolyte metabolism. McGraw Hill, New York, pp 583–615 In: Narins RGE (ed) (1994) Maxwell and Kleeman’s clinical disorders of fluid and electrolyte metabolism. McGraw Hill, New York, pp 583–615
17.
Zurück zum Zitat Flythe JE, Xue H, Lynch KE et al (2015) Association of mortality risk with various definitions of intradialytic hypotension. J Am Soc Nephrol 26:724–734CrossRef Flythe JE, Xue H, Lynch KE et al (2015) Association of mortality risk with various definitions of intradialytic hypotension. J Am Soc Nephrol 26:724–734CrossRef
18.
Zurück zum Zitat Mc Causland FR, Waikar SS (2015) Association of predialysis calculated plasma osmolarity with intradialytic blood pressure decline. Am J Kidney Dis 66(3):499–506CrossRef Mc Causland FR, Waikar SS (2015) Association of predialysis calculated plasma osmolarity with intradialytic blood pressure decline. Am J Kidney Dis 66(3):499–506CrossRef
19.
Zurück zum Zitat Song JH, Park GH, Lee SY et al (2005) Effect of sodium balance and the combination of ultrafiltration profile during sodium profiling hemodialysis on the maintenance of the quality of dialysis and sodium and fluid balances. J Am Soc Nephrol 16(1):237–246CrossRef Song JH, Park GH, Lee SY et al (2005) Effect of sodium balance and the combination of ultrafiltration profile during sodium profiling hemodialysis on the maintenance of the quality of dialysis and sodium and fluid balances. J Am Soc Nephrol 16(1):237–246CrossRef
20.
Zurück zum Zitat Kersh ES, Kronfield SJ, Unger A et al (1974) Autonomic insufficiency in uremia as a cause of hemodialysis-induced hypotension. N Engl J Med 290(12):650–653CrossRef Kersh ES, Kronfield SJ, Unger A et al (1974) Autonomic insufficiency in uremia as a cause of hemodialysis-induced hypotension. N Engl J Med 290(12):650–653CrossRef
21.
Zurück zum Zitat Cernaro V, Lacquaniti A, Lorenzano G et al (2012) Apelin, plasmatic osmolality and hypotension in dialyzed patients. Blood Purif 33(4):317–323CrossRef Cernaro V, Lacquaniti A, Lorenzano G et al (2012) Apelin, plasmatic osmolality and hypotension in dialyzed patients. Blood Purif 33(4):317–323CrossRef
22.
Zurück zum Zitat Gennari FJ (1984) Current concepts. Serum osmolality. Uses and limitations. N Engl J Med 310(2):102–105CrossRef Gennari FJ (1984) Current concepts. Serum osmolality. Uses and limitations. N Engl J Med 310(2):102–105CrossRef
23.
Zurück zum Zitat Arieff AI, Massry SG, Barrientos A et al (1973) Brain water and electrolyte metabolism in uremia: effects of slow and rapid hemodialysis. Kidney Int 4(3):177–187CrossRef Arieff AI, Massry SG, Barrientos A et al (1973) Brain water and electrolyte metabolism in uremia: effects of slow and rapid hemodialysis. Kidney Int 4(3):177–187CrossRef
24.
Zurück zum Zitat Casino FG, Basile C (2018) A user-friendly tool for incremental haemodialysis prescription. Nephrol Dial Transpl 33(6):1046–1053CrossRef Casino FG, Basile C (2018) A user-friendly tool for incremental haemodialysis prescription. Nephrol Dial Transpl 33(6):1046–1053CrossRef
25.
Zurück zum Zitat Maggiore Q, Pizzarelli F, Zoccali C et al (1981) Effect of extracorporeal blood cooling on dialytic arterial hypotension. Proc Eur Dial Transpl Assoc 18:597–602 Maggiore Q, Pizzarelli F, Zoccali C et al (1981) Effect of extracorporeal blood cooling on dialytic arterial hypotension. Proc Eur Dial Transpl Assoc 18:597–602
26.
Zurück zum Zitat Maggiore Q, Pizzarelli F, Sisca S et al (1982) Blood temperature and vascular stability during hemodialysis and hemofiltration. Trans Am Soc Artif Intern Organs 28:523–527PubMed Maggiore Q, Pizzarelli F, Sisca S et al (1982) Blood temperature and vascular stability during hemodialysis and hemofiltration. Trans Am Soc Artif Intern Organs 28:523–527PubMed
27.
Zurück zum Zitat Maggiore Q, Dattolo P, Piacenti M et al (1995) Thermal balance and dialysis hypotension. Int J Artif Organs 18(9):518–525CrossRef Maggiore Q, Dattolo P, Piacenti M et al (1995) Thermal balance and dialysis hypotension. Int J Artif Organs 18(9):518–525CrossRef
28.
Zurück zum Zitat Mahida BH, Dumler F, Zasuwa G et al (1983) Effect of cooled dialysate on serum catecholamines and blood pressure stability. Trans Am Soc Artif Intern Organs 29:384–389PubMed Mahida BH, Dumler F, Zasuwa G et al (1983) Effect of cooled dialysate on serum catecholamines and blood pressure stability. Trans Am Soc Artif Intern Organs 29:384–389PubMed
29.
Zurück zum Zitat Lucchi L, Fiore GB, Guadagni G et al (2004) Clinical evaluation of internal hemodiafiltration (iHDF): a diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers. Int J Artif Organs 27(5):414–419CrossRef Lucchi L, Fiore GB, Guadagni G et al (2004) Clinical evaluation of internal hemodiafiltration (iHDF): a diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers. Int J Artif Organs 27(5):414–419CrossRef
30.
Zurück zum Zitat Righetti M, Filiberti O, Ranghino A et al (2010) Internal hemodiafiltration versus low-flux bicarbonate dialysis: Results from a long-term prospective study. Int J Artif Organs 33(11):796–802CrossRef Righetti M, Filiberti O, Ranghino A et al (2010) Internal hemodiafiltration versus low-flux bicarbonate dialysis: Results from a long-term prospective study. Int J Artif Organs 33(11):796–802CrossRef
31.
Zurück zum Zitat Righetti M (2012) Internal hemodiafiltration. G Ital Nefrol 29(Suppl 55):S57–S61PubMed Righetti M (2012) Internal hemodiafiltration. G Ital Nefrol 29(Suppl 55):S57–S61PubMed
32.
Zurück zum Zitat Fiore GB, Guadagni G, Lupi A et al (2006) A new semiempirical mathematical model for prediction of internal filtration in hollow fiber hemodialyzers. Blood Purif 24(5–6):555–568CrossRef Fiore GB, Guadagni G, Lupi A et al (2006) A new semiempirical mathematical model for prediction of internal filtration in hollow fiber hemodialyzers. Blood Purif 24(5–6):555–568CrossRef
33.
Zurück zum Zitat Simic-Ogrizovic S, Backus G, Mayer A et al (2001) The influence of different glucose concentrations in haemodialysis solutions on metabolism and blood pressure stability in diabetic patients. Int J Artif Organs 24(12):863–869CrossRef Simic-Ogrizovic S, Backus G, Mayer A et al (2001) The influence of different glucose concentrations in haemodialysis solutions on metabolism and blood pressure stability in diabetic patients. Int J Artif Organs 24(12):863–869CrossRef
34.
Zurück zum Zitat Lepeytre F, Ghannoum M, Ammann H et al (2017) Formulas for calculated osmolarity and osmolal gap: a study of diagnostic accuracy. Am J Kidney Dis 70(3):347–356CrossRef Lepeytre F, Ghannoum M, Ammann H et al (2017) Formulas for calculated osmolarity and osmolal gap: a study of diagnostic accuracy. Am J Kidney Dis 70(3):347–356CrossRef
35.
Zurück zum Zitat Cornelis T, van der Sande FM, Eloot S et al (2014) Acute hemodynamic response and uremic toxin removal in conventional and extended hemodialysis and hemodiafiltration: a randomized crossover study. Am J Kidney Dis 64(2):247–256CrossRef Cornelis T, van der Sande FM, Eloot S et al (2014) Acute hemodynamic response and uremic toxin removal in conventional and extended hemodialysis and hemodiafiltration: a randomized crossover study. Am J Kidney Dis 64(2):247–256CrossRef
36.
Zurück zum Zitat Randomized A (2017) Single-blind, crossover trial of recovery time in high-flux hemodialysis and hemodiafiltration. Am J Kidney Dis 69(6):762–770CrossRef Randomized A (2017) Single-blind, crossover trial of recovery time in high-flux hemodialysis and hemodiafiltration. Am J Kidney Dis 69(6):762–770CrossRef
37.
Zurück zum Zitat Donauer J, Schweiger C, Rumberger B et al (2003) Reduction of hypotensive side effects during online-haemodiafiltration and low temperature haemodialysis. Nephrol Dial Transpl 18(8):1616–1622CrossRef Donauer J, Schweiger C, Rumberger B et al (2003) Reduction of hypotensive side effects during online-haemodiafiltration and low temperature haemodialysis. Nephrol Dial Transpl 18(8):1616–1622CrossRef
Metadaten
Titel
Sodium removal and plasma tonicity balance are not different in hemodialysis and hemodiafiltration using high-flux membranes
verfasst von
Vincenzo La Milia
Chiara Ravasi
Fabio Carfagna
Elena Alberghini
Ivano Baragetti
Laura Buzzi
Francesca Ferrario
Silvia Furiani
Gaia Santagostino Barbone
Giuseppe Pontoriero
Publikationsdatum
01.06.2019
Verlag
Springer International Publishing
Erschienen in
Journal of Nephrology / Ausgabe 3/2019
Print ISSN: 1121-8428
Elektronische ISSN: 1724-6059
DOI
https://doi.org/10.1007/s40620-018-00581-z

Weitere Artikel der Ausgabe 3/2019

Journal of Nephrology 3/2019 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Echinokokkose medikamentös behandeln oder operieren?

06.05.2024 DCK 2024 Kongressbericht

Die Therapie von Echinokokkosen sollte immer in spezialisierten Zentren erfolgen. Eine symptomlose Echinokokkose kann – egal ob von Hunde- oder Fuchsbandwurm ausgelöst – konservativ erfolgen. Wenn eine Op. nötig ist, kann es sinnvoll sein, vorher Zysten zu leeren und zu desinfizieren. 

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Wo hapert es noch bei der Umsetzung der POMGAT-Leitlinie?

03.05.2024 DCK 2024 Kongressbericht

Seit November 2023 gibt es evidenzbasierte Empfehlungen zum perioperativen Management bei gastrointestinalen Tumoren (POMGAT) auf S3-Niveau. Vieles wird schon entsprechend der Empfehlungen durchgeführt. Wo es im Alltag noch hapert, zeigt eine Umfrage in einem Klinikverbund.

VHF-Ablation nützt wohl nur bei reduzierter Auswurfleistung

02.05.2024 Ablationstherapie Nachrichten

Ob die Katheterablation von Vorhofflimmern bei Patienten mit Herzinsuffizienz die Komplikationsraten senkt, scheint davon abzuhängen, ob die Auswurfleistung erhalten ist oder nicht. Das legen die Ergebnisse einer Metaanalyse nahe.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.