Abstract

Purpose

Spica magnectic resonance imaging (MRI) is an established technique for postoperative determination of hip reduction in patients treated for developmental dysplasia of the hip (DDH). A hip abduction angle >55° is considered excessive and has been associated with epiphyseal osteonecrosis. Our purpose was to establish objective criteria for measuring hip abduction angles on MRI after hip reduction and spica casting in patients with DDH, and evaluate reproducibility and reliability of angle measurement using these criteria.

Methods

Forty patients with DDH at our institution who underwent spica MRI after hip reduction between 3 April 2008 and 3 March 2015 were identified. Hip abduction angles were measured on proton density axial images as follows. A transverse line was drawn connecting the posterior ischial tuberosities. A second line was drawn medially along the distal femoral diaphysis, and the angle between these two lines was measured; this value was subtracted from 90°, yielding the degree of abduction from midline. Measurements were independently performed by three faculty radiologists, one orthopedist, and one radiology resident. Inter-reader and intra-reader reliability was assessed using intraclass correlation (ICC), with 0 representing no agreement and 1 representing perfect agreement.

Results

For inter-reader reliability, the ICC of the five physicians was 0.89 (95 % CI 0.84–0.92). For intra-reader reliability, the ICC of the five physicians ranged from 0.90−0.97 (95 % CI 0.85–0.98). The mean standard deviation of hip abduction angle measurement among readers was 3.6°.

Conclusion

The proposed hip abduction angle measurement criteria for spica MRI are both reproducible and easy to perform. The high ICC and low standard deviation of independently evaluated hip abduction angles indicates high reproducibility of measurement. This applies to both inter- and intra-reader reliability.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Bis zum 22.10. bestellen und 100 € sparen!

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Nicht verpassen: e.Med bis 22. Oktober 100 € günstiger.

e.Med Pädiatrie

Kombi-Abonnement

Mit e.Med Pädiatrie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Pädiatrie, den Premium-Inhalten der pädiatrischen Fachzeitschriften, inklusive einer gedruckten Pädiatrie-Zeitschrift Ihrer Wahl.

Nicht verpassen: e.Med bis 22. Oktober 100 € günstiger.

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 5/2016

Journal of Children's Orthopaedics 5/2016Zur Ausgabe

Neu im Fachgebiet Orthopädie und Unfallchirurgie

 

 

 
 

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Orthopädie und Unfallchirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise