Background

The measurement of Apical Vertebral Rotation (AVR) is vital to the surgical and conservative treatment of idiopathic scoliosis. Several measuring methods are used to assess the AVR on plain radiographs, including the visual Nash and Moe, Perdriolle’s torsion meter and Raimondi’s table, all of which have positive and negative aspects[13].

Purpose

We developed an AVR image scale of 0-55° rotation, pre-determined, to assess its ease of use as a visual method when comparing the mean inter- and intra-reliability against Perdriolle’s and Raimondi’s scales.

Method

A human lumbar vertebra (L4) set on a rotating device, and a series of X rays were taken, at 1 degree increments, from 0-55° clockwise rotation. These images were flipped to produce 0-55° counterclockwise rotation. The apical rotations of 39 curves was measured by three different observers (each having more than three years of experience specializing in the field of scoliosis) using the SpineCor AVR scale, Perdriolle’s torsion meter and Raimondi’s table. The measurements were taken twice, with a minimum of one week between each measurement.

Results

The inter-rater mean difference for the SpineCor AVR scale versus both Perdriolle’s and Raimondi’s was the same (within 0.01°) but this mean difference was greater than the mean difference between Raimondi’s and Perdriolle’s by 0.48° and 0.49° respectively (SpineCor AVR scale versus Raimondi = mean difference of 4.18° SD+/- 2.04°, SpineCor AVR scale v Perdriolle’s = mean difference 4.19° SD +/- 2.05°, Raimondi’s v Perdriolle’s = 3.70° SD +/- 1.92°); the intra-rater mean difference was 1.07° greater with the SpineCor AVR scales than with Perdriolle’s and 0.45° greater than Raimondi’s table (intra-rater mean difference for the three testers with SpineCor images= 2.29° SD +/- 0.44°, with Raimondi’s = 1.84° SD +/- 0.39° and with Perdriolle’s = 1.22° SD +/- 0.44°).

Conclusions and discussion

The SpineCor AVR scales demonstrated high intra-reliability mean differences with a mean difference of 2.29° SD +/- 0.44° and inter-reliability of 4.18° +/- 2.04° SD and 4.19° +/- 2.05° SD, which does appear to demonstrate favourable intra- and inter-reliability in comparison to both Perdriolle’s and Raimondi’s scales[1, 2].
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Literatur
1.
Zurück zum Zitat Omeroglu H, Ozekin O, Bicimoglu A: 'A measurement of vertebral rotation in idiopathic scoliosis using the Perdriolle torsionmeter: a clinical study on intra-observer and inter-observer error'. Eur. Spine J. 1996, 5 (3): 167-171. 10.1007/BF00395508.CrossRefPubMed Omeroglu H, Ozekin O, Bicimoglu A: 'A measurement of vertebral rotation in idiopathic scoliosis using the Perdriolle torsionmeter: a clinical study on intra-observer and inter-observer error'. Eur. Spine J. 1996, 5 (3): 167-171. 10.1007/BF00395508.CrossRefPubMed
2.
Zurück zum Zitat Lam GC: 'Vertebral rotation measurement: a summary and comparison of common radiographic and CT methods'. Scoliosis. 2008, 3: 16-10.1186/1748-7161-3-16.PubMedCentralCrossRefPubMed Lam GC: 'Vertebral rotation measurement: a summary and comparison of common radiographic and CT methods'. Scoliosis. 2008, 3: 16-10.1186/1748-7161-3-16.PubMedCentralCrossRefPubMed
3.
Zurück zum Zitat Weiss HR: 'Measurement of vertebral rotation: Perdriolle versus Raimondi'. Eur Spine J. 1995, 4 (1): 34-38. 10.1007/BF00298416.CrossRefPubMed Weiss HR: 'Measurement of vertebral rotation: Perdriolle versus Raimondi'. Eur Spine J. 1995, 4 (1): 34-38. 10.1007/BF00298416.CrossRefPubMed
Metadaten
Titel
'SpineCor' apical vertebral rotation measuring tool
verfasst von
Alison Murray
Tim Cook
Publikationsdatum
01.09.2013
Verlag
BioMed Central
Erschienen in
Scoliosis and Spinal Disorders / Ausgabe Sonderheft 2/2013
Elektronische ISSN: 2397-1789
DOI
https://doi.org/10.1186/1748-7161-8-S2-O19

Weitere Artikel der Sonderheft 2/2013

Scoliosis and Spinal Disorders 2/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.