Ausgabe 10/2007
Inhalt (29 Artikel)
PET probes and oncological surgery: a productive new marriage for nuclear medicine?
Orazio Schillaci
Positron detection for the intraoperative localisation of cancer deposits
Morand Piert, Maria Burian, Günther Meisetschläger, Hubert J. Stein, Sibylle Ziegler, Jörg Nährig, Maria Picchio, Andreas Buck, Joerg R. Siewert, Markus Schwaiger
Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract
A. Hubalewska-Dydejczyk, J. Kulig, P. Szybinski, R. Mikolajczak, D. Pach, A. Sowa-Staszczak, K. Fröss-Baron, B. Huszno
Prospective comparison of two gamma probes for intraoperative detection of 18F-FDG: in vitro assessment and clinical evaluation in differentiated thyroid cancer patients with iodine-negative recurrence
Chantal Curtet, Thomas Carlier, Eric Mirallié, Caroline Bodet-Milin, Caroline Rousseau, Jacques Barbet, Francoise Kraeber-Bodéré
Imaging of tumour hypoxia using PET and 18F-labelled tracers: biology meets technology
Tove Grönroos, Heikki Minn
Tumour hypoxia imaging with [18F]FAZA PET in head and neck cancer patients: a pilot study
M. Souvatzoglou, A. L. Grosu, B. Röper, B. J. Krause, R. Beck, G. Reischl, M. Picchio, H.-J. Machulla, H.-J. Wester, M. Piert
Predicting response to chemoradiotherapy in rectal and oesophageal cancer with 18F-FDG: prognostic value and possible role in patient management
Elif Hindié, Christophe Hennequin, Jean-luc Moretti
Sequential FDG-PET/CT reliably predicts response of locally advanced rectal cancer to neo-adjuvant chemo-radiation therapy
Carlo Capirci, Lucia Rampin, Paola A. Erba, Fabrizio Galeotti, Giorgio Crepaldi, Elena Banti, Marcello Gava, Stefano Fanti, Giuliano Mariani, Pier Carlo Muzzio, Domenico Rubello
PET/CT colonography in patients with colorectal polyps: a feasibility study
Pier Paolo Mainenti, Barbara Salvatore, Dario D’Antonio, Teresa De Falco, Giovanni Domenico De Palma, Francesco Paolo D’Armiento, Luigi Bucci, Leonardo Pace, Marco Salvatore
Diagnostic impact of PET with 18F-FDG, 18F-DOPA and 3-O-methyl-6-[18F]fluoro-DOPA in recurrent or metastatic medullary thyroid carcinoma
B. Beuthien-Baumann, A. Strumpf, J. Zessin, J. Bredow, J. Kotzerke
Correlation of 18F-FLT and 18F-FDG uptake on PET with Ki-67 immunohistochemistry in non-small cell lung cancer
Yuka Yamamoto, Yoshihiro Nishiyama, Shinya Ishikawa, Jun Nakano, Sung Soo Chang, Shuji Bandoh, Nobuhiro Kanaji, Reiji Haba, Yoshio Kushida, Motoomi Ohkawa
Comparison of 68Ga-DOTATOC PET and 111In-DTPAOC (Octreoscan) SPECT in patients with neuroendocrine tumours
I. Buchmann, M. Henze, S. Engelbrecht, M. Eisenhut, A. Runz, M. Schäfer, T. Schilling, S. Haufe, T. Herrmann, U. Haberkorn
Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer
Ukihide Tateishi, Tetsuo Maeda, Tsuyoshi Morimoto, Mototaka Miyake, Yasuaki Arai, E. Edmund Kim
Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma
Rafał Czepczyński, Maria Gemma Parisella, Jerzy Kosowicz, Renata Mikołajczak, Katarzyna Ziemnicka, Maria Gryczyńska, Jerzy Sowiński, Alberto Signore
Are there adaptive changes in the human brain of patients with Parkinson’s disease treated with long-term deep brain stimulation of the subthalamic nucleus? A 4-year follow-up study with regional cerebral blood flow SPECT
Stelvio Sestini, Alberto Pupi, Franco Ammannati, Ramat Silvia, Sandro Sorbi, Antonio Castagnoli
Partial volume effect-corrected FDG PET and grey matter volume loss in patients with mild Alzheimer’s disease
Miharu Samuraki, Ichiro Matsunari, Wei-Ping Chen, Kazuyoshi Yajima, Daisuke Yanase, Akihiko Fujikawa, Nozomi Takeda, Shintaro Nishimura, Hiroshi Matsuda, Masahito Yamada
Synthesis and initial evaluation of [11C](R)-RWAY in monkey—a new, simply labeled antagonist radioligand for imaging brain 5-HT1A receptors with PET
Julie A. McCarron, Sami S. Zoghbi, H. Umesha Shetty, Eric S. Vermeulen, Håkan V. Wikström, Masanori Ichise, Fumihiko Yasuno, Christer Halldin, Robert B. Innis, Victor W. Pike
Performance of the new generation of whole-body PET/CT scanners: Discovery STE and Discovery VCT
M. Teräs, T. Tolvanen, J. J. Johansson, J. J. Williams, J. Knuuti
Lymphoscintigraphic and intraoperative detection of sentinel lymph nodes
Ali T. Akpinar
Clinical radionuclide therapy dosimetry: the quest for the “Holy Gray”
Glenn Flux, Manuel Bardies, Carlo Chiesa, Myriam Monsieurs, Sauli Savolainen, Sven-Erik Strand, Michael Lassmann
Negative MIBI thyroid scans exclude differentiated and medullary thyroid cancer in 100% of patients with hypofunctioning thyroid nodules
Luis-Mauricio Hurtado-López, Carlos Martínez-Duncker
11C/18F-choline PET or 11C/18F-acetate PET in prostate cancer: may a choice be recommended?
Cristina Nanni, Paolo Castellucci, Mohsen Farsad, Domenico Rubello, Stefano Fanti
Hybrid 3D Sono/PET in a mouse
N. Lang, S. Hermann, S. Hold, M. Mienkina, L. Stegger, J. Stypmann, O. Schober, M. Schäfers, K. P. Schäfers, G. Schmitz
Habib Zaidi: Quantitative Analysis in Nuclear Medicine Imaging
Mario Quarantelli, Anna Prinster
G. Schmidt. Thieme clinical companions: ultrasound, 5th edition.
M. P. M. Stokkel, Luigi Mansi
C Schiepers (ed): Diagnostic nuclear medicine, 2nd rev. edn.
Vincenzo Cuccurullo, Pier Francesco Rambaldi
Diagnosis of endoneural sciatic nerve invasion by uterine cervical epidermoid cancer using [18F]FDG-PET/CT
Gaetano Paone, Emmanuel Itti, Daniela Capacchione, Nicolas Ortonne, Pierre Brugières, Eva Evangelista, Faouzi Kallel, Jean-Pascal Lefaucheur, Alain Créange, Michel Meignan