Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 5/2013

01.05.2013 | Surgical Technique

Surgical Technique: Simple Technique for Removing a Locking Recon Plate With Damaged Screw Heads

verfasst von: Nirmal Raj Gopinathan, (MS)Ortho, Mandeep Singh Dhillon, (MS)Ortho, Rajesh Kumar, (MS)Ortho

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 5/2013

Einloggen, um Zugang zu erhalten

Abstract

Background

The introduction of locking plates in the treatment of periarticular fractures was a major breakthrough in orthopaedic evolution. Removal of these implants is extremely difficult as a result of cold welding and stripping of screw heads.

Description of Technique

A 31-year-old man had a schwannoma of the left C5-C6 nerve roots and upper trunk of the brachial plexus. One year before presentation he had undergone excision of the lesion through an approach using a clavicular osteotomy. The osteotomy had been fixed with a titanium locking recon plate. While surgically removing the implant, only one screw could be removed. The remaining five screws could not be turned owing to cold welding; repeated attempts at removing the screws damaged the screw heads. A large bolt cutter was used to cut the plate between the holes, and the resulting rectangular sections with the screws then were unscrewed from the bone.

Review of Literature

Limited literature is available regarding techniques for locking screw removal. These include using a carbide drill bit or diamond-tipped burr, high-speed disc, or conical extraction screw.

Conclusions

Not all centers have specialized instruments such as carbide drill bits to remove screw heads, but a large bolt cutter usually is available when screws cannot be unscrewed owing to cold welding. The technique of cutting is easily reproducible and does not require additional soft tissue stripping.
Literatur
1.
Zurück zum Zitat Bae JH, Oh JK, Oh CW, Hur CR. Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg. 2009;129:91–95.PubMedCrossRef Bae JH, Oh JK, Oh CW, Hur CR. Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg. 2009;129:91–95.PubMedCrossRef
2.
Zurück zum Zitat Bhutta MA, Dunkow PD, Lovell ME. A simple technique for removal of screws with damaged heads. Ann R Coll Surg Engl. 2003;85:207.PubMedCrossRef Bhutta MA, Dunkow PD, Lovell ME. A simple technique for removal of screws with damaged heads. Ann R Coll Surg Engl. 2003;85:207.PubMedCrossRef
3.
Zurück zum Zitat Cole PA, Zlowodzki M, Kregor PJ. Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma. 2004;18:528–535.PubMedCrossRef Cole PA, Zlowodzki M, Kregor PJ. Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma. 2004;18:528–535.PubMedCrossRef
4.
Zurück zum Zitat Dougherty P, Kim D, Meisterling S, Wybo C, Yeni Y. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model. J Orthop Trauma. 2008;22:399–403.PubMedCrossRef Dougherty P, Kim D, Meisterling S, Wybo C, Yeni Y. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model. J Orthop Trauma. 2008;22:399–403.PubMedCrossRef
5.
Zurück zum Zitat Ehlinger M, Adam P, Simon P, Bonnomet F. Technical difficulties in hardware removal in titanium compression plates with locking screws. Orthop Traumatol Surg Res. 2009;95:373–376.PubMedCrossRef Ehlinger M, Adam P, Simon P, Bonnomet F. Technical difficulties in hardware removal in titanium compression plates with locking screws. Orthop Traumatol Surg Res. 2009;95:373–376.PubMedCrossRef
6.
Zurück zum Zitat Georgiadis GM, Gove NK, Smith AD, Rodway IP. Removal of the less invasive stabilization system. J Orthop Trauma. 2004;18:562–564.PubMedCrossRef Georgiadis GM, Gove NK, Smith AD, Rodway IP. Removal of the less invasive stabilization system. J Orthop Trauma. 2004;18:562–564.PubMedCrossRef
7.
Zurück zum Zitat Hak DJ, McElvany M. Removal of broken hardware. J Am Acad Orthop Surg. 2008;16:113–120.PubMed Hak DJ, McElvany M. Removal of broken hardware. J Am Acad Orthop Surg. 2008;16:113–120.PubMed
8.
Zurück zum Zitat Hamilton P, Doig S, Williamson O. Technical difficulty of metal removal after LISS plating. Injury. 2004;35:626–628.PubMedCrossRef Hamilton P, Doig S, Williamson O. Technical difficulty of metal removal after LISS plating. Injury. 2004;35:626–628.PubMedCrossRef
9.
Zurück zum Zitat Kumar G, Dunlop C. A technique to remove a jammed locking screw from a locking plate. Clin Orthop Relat Res. 2011;469:613–616.PubMedCrossRef Kumar G, Dunlop C. A technique to remove a jammed locking screw from a locking plate. Clin Orthop Relat Res. 2011;469:613–616.PubMedCrossRef
10.
Zurück zum Zitat Pattison G, Reynold J, Hardy J. Salvaging a stripped drive connection when removing screws. Injury. 1999;30:74–75.PubMedCrossRef Pattison G, Reynold J, Hardy J. Salvaging a stripped drive connection when removing screws. Injury. 1999;30:74–75.PubMedCrossRef
11.
Zurück zum Zitat Phisitkul P, McKinley TO, Nepola JV, Marsh JL. Complications of locking plate fixation in complex proximal tibia injuries. J Orthop Trauma. 2007;21:83–91.PubMedCrossRef Phisitkul P, McKinley TO, Nepola JV, Marsh JL. Complications of locking plate fixation in complex proximal tibia injuries. J Orthop Trauma. 2007;21:83–91.PubMedCrossRef
12.
Zurück zum Zitat Raja S, Imbuldeniya AM, Garg S, Groom G. Difficulties encountered removing locked plates. Ann R Coll Surg Engl. 2012;94:502–505.PubMedCrossRef Raja S, Imbuldeniya AM, Garg S, Groom G. Difficulties encountered removing locked plates. Ann R Coll Surg Engl. 2012;94:502–505.PubMedCrossRef
13.
Zurück zum Zitat Suzuki T, Smith WR, Stahel PF, Morgan SJ, Baron AJ, Hak DJ. Technical problems and complications in the removal of the less invasive stabilization system. J Orthop Trauma. 2010;24:369–373.PubMedCrossRef Suzuki T, Smith WR, Stahel PF, Morgan SJ, Baron AJ, Hak DJ. Technical problems and complications in the removal of the less invasive stabilization system. J Orthop Trauma. 2010;24:369–373.PubMedCrossRef
Metadaten
Titel
Surgical Technique: Simple Technique for Removing a Locking Recon Plate With Damaged Screw Heads
verfasst von
Nirmal Raj Gopinathan, (MS)Ortho
Mandeep Singh Dhillon, (MS)Ortho
Rajesh Kumar, (MS)Ortho
Publikationsdatum
01.05.2013
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 5/2013
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2733-5

Weitere Artikel der Ausgabe 5/2013

Clinical Orthopaedics and Related Research® 5/2013 Zur Ausgabe

Symposium: Special Considerations for TKA in Asian Patients

Comparative Demographics, ROM, and Function After TKA in Chinese, Malays, and Indians

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.