Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 3/2011

01.03.2011 | Arthroscopy and Sports Medicine

The “butterfly” suture technique for meniscal repair

verfasst von: Taner Gunes, Bora Bostan, Mehmet Erdem, Murat Asci, Cengiz Sen, Mehmet Halidun Kelestemur

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

One of the important factors effecting meniscal healing is the strength of primary fixation obtained by repairing technique. From this perspective, it is important to choose the technique ensuring a higher primary fixation strength for meniscal repairs. We described a new technique for meniscal repair called “butterfly” technique using Viper device and hypothesized that high primary fixation strength can be obtained with this technique. The study was performed on calve knees. Full-thickness longitudinal tears 2 cm in length and 3 mm medial from the periphery were created in corpora of medial menisci of 14 calves. After creating tears, menisci were divided into two equal groups. In Group 1, two vertical loop sutures 1 cm apart were placed using a Viper device. Whereas in Group 2, tears were repaired using “butterfly” sutures. The mean load to failure was 156.3 ± 13.1 and 186 ± 15.8 N in Group 1 and 2, respectively (p = 0.002). The fixation strength in Group 2 was significantly higher than in Group 1. We suggest that, using Viper device and all-inside “butterfly” suturing techniques, meniscal ruptures with appropriate locations can be repaired with higher primary fixation strength.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Allen PR, Denham RA, Swan AV (1984) Late degenerative changes after meniscectomy. Factors affecting the knee after operation. J Bone Jt Surg Br 66:666–671 Allen PR, Denham RA, Swan AV (1984) Late degenerative changes after meniscectomy. Factors affecting the knee after operation. J Bone Jt Surg Br 66:666–671
2.
Zurück zum Zitat Asik M, Sener N (2002) Failure strength of repair devices versus meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 10:25–29CrossRefPubMed Asik M, Sener N (2002) Failure strength of repair devices versus meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 10:25–29CrossRefPubMed
4.
Zurück zum Zitat Boenisch UW, Faber KJ, Ciarelli M, Steadman JR, Arnoczky SP (1999) Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures. Am J Sports Med 27:626–631PubMed Boenisch UW, Faber KJ, Ciarelli M, Steadman JR, Arnoczky SP (1999) Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures. Am J Sports Med 27:626–631PubMed
5.
Zurück zum Zitat Chang HC, Caborn DN, Nyland J, Burden R (2006) Effect of lesion location on fixation strength of the meniscal viper repair system: an in vitro study using porcine menisci. Arthroscopy 22:394–399CrossRefPubMed Chang HC, Caborn DN, Nyland J, Burden R (2006) Effect of lesion location on fixation strength of the meniscal viper repair system: an in vitro study using porcine menisci. Arthroscopy 22:394–399CrossRefPubMed
6.
Zurück zum Zitat Chang HC, Nyland J, Caborn DN, Burden R (2005) Biomechanical evaluation of meniscal repair systems: a comparison of the Meniscal Viper Repair System, the vertical mattress FasT-Fix Device, and vertical mattress ethibond sutures. Am J Sports Med 33:1846–1852CrossRefPubMed Chang HC, Nyland J, Caborn DN, Burden R (2005) Biomechanical evaluation of meniscal repair systems: a comparison of the Meniscal Viper Repair System, the vertical mattress FasT-Fix Device, and vertical mattress ethibond sutures. Am J Sports Med 33:1846–1852CrossRefPubMed
7.
Zurück zum Zitat Karaoglu S, Duygulu F, Inan M, Baktir A (2002) Improving the biomechanical properties of the T-fix using oblique direction: in vitro study on bovine menisci. Knee Surg Sports Traumatol Arthrosc 10:198–201CrossRefPubMed Karaoglu S, Duygulu F, Inan M, Baktir A (2002) Improving the biomechanical properties of the T-fix using oblique direction: in vitro study on bovine menisci. Knee Surg Sports Traumatol Arthrosc 10:198–201CrossRefPubMed
8.
Zurück zum Zitat Kocabey Y, Taser O, Nyland J, Doral MN, Demirhan M, Caborn DN, Sarban S (2006) Pullout strength of meniscal repair after cyclic loading: comparison of vertical, horizontal, and oblique suture techniques. Knee Surg Sports Traumatol Arthrosc 14:998–1003CrossRefPubMed Kocabey Y, Taser O, Nyland J, Doral MN, Demirhan M, Caborn DN, Sarban S (2006) Pullout strength of meniscal repair after cyclic loading: comparison of vertical, horizontal, and oblique suture techniques. Knee Surg Sports Traumatol Arthrosc 14:998–1003CrossRefPubMed
9.
Zurück zum Zitat Proctor CS, Schmidt MB, Whipple RR, Kelly MA, Mow VC (1989) Material properties of the normal medial bovine meniscus. J Orthop Res 7:771–782CrossRefPubMed Proctor CS, Schmidt MB, Whipple RR, Kelly MA, Mow VC (1989) Material properties of the normal medial bovine meniscus. J Orthop Res 7:771–782CrossRefPubMed
10.
Zurück zum Zitat Rankin CC, Lintner DM, Noble PC, Paravic V, Greer E (2002) A biomechanical analysis of meniscal repair techniques. Am J Sports Med 30:492–497PubMed Rankin CC, Lintner DM, Noble PC, Paravic V, Greer E (2002) A biomechanical analysis of meniscal repair techniques. Am J Sports Med 30:492–497PubMed
11.
Zurück zum Zitat Sgaglione NA, Steadman JR, Shaffer B, Miller MD, Fu FH (2003) Current concepts in meniscus surgery: resection to replacement. Arthroscopy 19(Suppl 1):161–188CrossRefPubMed Sgaglione NA, Steadman JR, Shaffer B, Miller MD, Fu FH (2003) Current concepts in meniscus surgery: resection to replacement. Arthroscopy 19(Suppl 1):161–188CrossRefPubMed
12.
Zurück zum Zitat Small NC (1988) Complications in arthroscopic surgery performed by experienced arthroscopists. Arthroscopy 4:215–221CrossRefPubMed Small NC (1988) Complications in arthroscopic surgery performed by experienced arthroscopists. Arthroscopy 4:215–221CrossRefPubMed
Metadaten
Titel
The “butterfly” suture technique for meniscal repair
verfasst von
Taner Gunes
Bora Bostan
Mehmet Erdem
Murat Asci
Cengiz Sen
Mehmet Halidun Kelestemur
Publikationsdatum
01.03.2011
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 3/2011
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-010-1148-6

Weitere Artikel der Ausgabe 3/2011

Archives of Orthopaedic and Trauma Surgery 3/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.