Background

There is clear evidence that patients with prior myocardial infarction and a reduced ejection fraction benefit from implantation of a cardioverter-defibrillator (ICD). It is unclear whether this benefit is altered by whether or not revascularization is performed prior to ICD implantation.

Methods

This was a retrospective cohort study following patients who underwent ICD implantation from 2002 to 2014. Patients with ischemic cardiomyopathy and either primary or secondary prevention ICDs were selected for inclusion. Using the electronic medical record, cardiac catheterization data, revascularization status (percutaneous coronary intervention or coronary bypass surgery) were recorded. The outcomes were mortality and ventricular arrhythmia.

Results

There were 606 patients included in the analysis. The mean age was 66.3 ± 10.1 years, 11.9% were women, and the mean LVEF was 30.5 ± 12.0, 58.9% had a primary indication for ICD, 82.0% of the cohort had undergone coronary catheterization prior to ICD implantation. In the overall cohort, there were fewer mortality and ventricular arrhythmia events in patients who had undergone prior revascularization. In patients who had an ICD for secondary prevention, revascularization was associated with a decrease in mortality (HR 0.46, 95% CI (0.24, 0.85) p = 0.015), and a trend towards fewer ventricular arrhythmia (HR 0.62, 95% CI (0.38, 1.00) p = 0.051). There was no association between death or ventricular arrhythmia with revascularization in patients with primary prevention ICDs.

Conclusion

Revascularization may be beneficial in preventing recurrent ventricular arrhythmia, and should be considered as adjunctive therapy to ICD implantation to improve cardiovascular outcomes.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
ICD
Implantable Cardioverter defibrillator
LVEF
Left ventricular ejection fraction
EF
Ejection fraction
HR
Hazard ratio
CI
Confidence interval
VT
Ventricular tachycardia
VF
Ventricular fibrillation
CAD
Coronary artery disease
CMP
Cardiomyopathy
ATP
Anti-tachycardia pacing

Introduction

Sudden cardiac death accounts for at least 300,000 deaths each year in the United States alone [1] with at least 80% occurring in the setting of coronary artery disease [2]. The arrhythmogenic effects of coronary artery occlusion have been well demonstrated in animal and human studies [35]. In patients with ischemic cardiomyopathy (ICM), the effect of revascularization on mortality has largely been driven from surgical trials assessing the benefit of coronary artery bypass surgery (CABG) with limited evidence for the mortality benefit of percutaneous coronary intervention in this patient population [6]. In a large randomized trial of CABG versus medical therapy, no mortality benefit was observed as the study was underpowered; however, 10 year follow-up showed overall survival benefit from revascularization [7].. Thus, the overall survival association between coronary revascularization and mortality in this patient population is clear. Nevertheless, the evidence is conflicting regarding the association of revascularization and recurrent ventricular arrhythmia in ICM patients with some trials reporting beneficial association [8, 9] and others reporting no association [1012]. In this study we assessed the association between revascularization and the clinical outcomes of mortality and recurrent ventricular arrhythmia in patients with ICM and implantable cardiac defibrillator (ICD) utilizing data from a large provincial ICD registry in real world setting.

Methods

Study design and patient population

This is a retrospective cohort analysis of patients with ICDs between 2002 and 2014. Data from all patients who underwent ICD or cardiac resynchronization therapy defibrillator (CRT-D) for any reason and had known ischemic heart disease in the province of Nova Scotia, Canada were included. The protocol was approved by the institutional research ethics board. The patient cohort was derived from a comprehensive provincial ICD registry, details of which have been published previously [13]. Patients with inherited cardiomyopathy, ion channelopathies, non-ischemic cardiomyopathy, and those without documented coronary anatomy were excluded from this analysis.
Using the electronic medical record and paper records when required, the following variables were recorded: baseline demographics, clinical characteristics, medications, indication for ICD, cardiac catheterization data, revascularization status (percutaneous coronary intervention, coronary bypass surgery or both interventions), and cardiac non-invasive imaging for CAD including both radionuclide imaging and stress echocardiography. ICD programming was left to the discretion of the electrophysiologist responsible for the care of the patient; shock reduction programming came into effect at the end of this study. The basic programming principles in primary prevention patients were as follows: VT zone range 176–188 bpm, three bursts of ATP followed by the maximum number of shocks, detection intervals varied by device manufacturer but were based on programming in the RAFT study [14]. The VF zone was shock only, with ATP prior to shock delivery in newer generation devices. In secondary prevention patients, the VT zone was set to 20 bpm lower than the documented VT rate, with similar principles to the primary prevention devices for the remainder of the programming. Treatment of ventricular arrhythmias were performed according to current guidelines at the time of this study; this included amiodarone, sotalol, mexilitine or catheter ablation, as indicated [15].
Coronary anatomy and revascularization status were obtained from cardiac catheterization reports and coronary artery bypass graft surgery (CABG) report prior to ICD implantation. If patients had both CABG and percutaneous coronary intervention (PCI), each separate procedure was reviewed to determine the extent of revascularization. Any stenosis greater than or equal to 70% in the territory of the left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) was recorded and deemed significant. Also, any stenosis greater than or equal to 50% in the left main was recorded and deemed significant. Each coronary territory was assessed for status of revascularization and recorded. Based on these findings, patients were divided into two groups based on revascularization status prior to ICD implantation as follows: prior revascularization, and no revascularization groups. Prior revascularization was defined as intervening on all significant coronary artery disease to the greatest extent possible, via PCI, CABG or both.

Outcome measures

The outcome measures were all-cause mortality, time to first appropriate shock, and time to first appropriate shock or ATP, measured from time ICD implantation. All therapies (shocks and ATP) from the implantable defibrillator were obtained from device interrogation at scheduled or unscheduled clinic visits, remote follow-ups and any emergency department visits or hospitalizations. All devices were capable of continuous monitoring, with storage of any detected events in the device memory. The follow-up schedule was every six months either in-clinic or through the use of remote monitoring, as per current guidelines [16]. All ICD therapies were independently adjudicated for appropriateness by two cardiac electrophysiologists blinded to the cohort allocation of the patient. Any disagreement between the two interpretations was resolved by review with a third electrophysiologist, also blinded. Mortality was obtained from Vital Statistics of Nova Scotia.

Statistical analysis

Categorical variables were described as frequencies with percentages; continuous variables were described as mean ± SD. Demographic and clinical characteristics were compared between cohorts using Fisher’s exact test for categorical data and the Student’s t-test for continuous data.
Using Kaplan-Meier analysis, time to either death or ventricular arrhythmia were compared between the no-revascularization group and the prior revascularization group. This analysis was also implemented within each of the Primary and Secondary indication subgroups. The log-rank test was used to test for statistical significance. Time to mortality, and time to ventricular arrhythmia were also assessed individually and effect size data summarized as Hazard Ratios (HR) and 95% confidence intervals (CI) using Cox proportional hazard models. A multivariable Cox proportional hazard model was used to assess the association between revascularization and composite end-point while adjusting for known confounders as well as time to revascularization, identified a priori based on published literature including sex, age, sex, age, ejection fraction, left main or three vessel disease, time to revascularization and creatinine [17, 18]. P-values less than 0.05 were considered to be statistically significant. All analyses were performed using SAS 9.4 (the SAS Institute, Cary NC).

Results

Population characteristics

There were 2034 patients included in the registry from 2002 until 2014. Of these, 606 patients fulfilled the inclusion criteria. Mean follow up was 5.5 ± 3.1 years. Patients were divided into no revascularization (n = 109) and prior revascularization (n = 497) groups, as shown in Fig. 1. The mean age was 66.3 ± 10.1 years, 72 women (11.9%), mean LVEF for the cohort was 30.5 ± 12.0%. Of the study population 58.9% had a primary indication for ICD and 69.3% had a prior history of heart failure symptoms. Cardiac resynchronization therapy was present in 95 patients (19.1%) in the prior revascularization group, and 19 (17.4%) in the no revascularization group. Coronary catheterization was performed in 89% of the cohort prior to ICD implantation. Revascularization was performed in 95.3% of the cohort prior to ICD implantation, with a median of 3.5 (IQR 0.7,10) years prior to ICD implantation. In the secondary prevention group, this was a median of 2.2 (IQR 0.04, 10) years. The baseline characteristics were similar between the no revascularization and prior revascularization groups (Table 1). Utilizing the Charlson Comorbidity Index, the burden of comorbidity was similar in both groups (5.7 vs 5.6, p = 0.45). In addition, baseline medications were similar between groups. Over 90 and 85% of the cohort were treated with beta-blocker and angiotensin-converting enzyme inhibitors/angiotensin receptor blockers at baseline, respectively. (Table 1.)
Table 1
Baseline characteristics
Variable
Prior revascularization
N = 497 (%)
No revascularization N = 109 (%)
P value
Age
66.3 ± 10.2
66.4 ± 9.9
0.90
Women
61 (12.3)
11 (10.1)
0.62
Ejection fraction
31.0 ± 12.2
28.4 ± 11.2
0.04
Primary Prevention
292 (58.8)
65 (59.6)
0.91
Cardiac resynchronization therapy
95 (19.1)
19 (17.4)
0.82
Heart Failure
338 (68.0)
82 (75.2)
0.17
Atrial fibrillation
166 (33.4)
38 (34.9)
0.82
Chronic obstructive pulmonary disease
82 (16.5)
14 (12.8)
0.39
Diabetes
191 (38.4)
34 (31.2)
0.19
Hypertension
322 (64.8)
63 (57.8)
0.19
Hyperlipidemia
339 (68.2)
63 (57.8)
0.044
Peripheral vascular disease
77 (15.5)
16 (14.7)
0.88
Creatinine (umol/L)
104.8 ± 61.6
103.2 ± 60.3
0.81
NYHA Class III
128/489 (26.2)
32/105 (30.4)
0.29
NYHA IV
6/489 (1.2)
3/105 (2.9)
0.95
Charlson Comorbidity Index
5.7 (1.7)
5.6 (1.8)
0.45
Beta Blocker
460 (92.6)
104 (95.4)
0.40
Angiotensin converting enzyme inhibitor/angiotensin receptor blocker
426 (85.7)
93 (85.3)
0.88
Spironolactone
98 (19.7)
24 (22.0)
0.60
Loop Diuretic
270 (54.3)
60 (55.1)
0.92
Oral anticoagulant
159 (32.0)
41 (37.6)
0.26
Digoxin
86 (17.3)
24 (22.0)
0.27
Amiodarone
88 (17.7)
21 (19.3)
0.68
Other antiarrhythmic
16 (3.2)
5 (4.6)
0.56
In this cohort, patients who had received ICD therapy (ATP, shock with ATP or shock without ATP) were grouped based on revascularization status. The median time lapsed from revascularization to ICD therapy was 2.9 years with IQR (0.3–9.8). Among the patients with prior revascularization, 42 patients (8.5%) had appropriate ICD therapy and only 1 patient had received ATP therapy alone. In contrast, among the non-revascularized subgroup, 14 patients (12.8%) had received appropriate ICD therapy, and none received isolated ATP therapy.

Outcomes

The extent of coronary artery disease prior to ICD implantation differed between the groups (p <  0.001). The revascularized group had mostly three vessel disease (36.6%) while single vessel disease predominated in the no revascularization group (40.4%) (Table 2). In addition, the revascularized group had a higher proportion of patients with significant left main disease when compared to the no revascularization group (18.1 and 2.9% respectively with p <  0.0001). (Fig. 2) Among the entire cohort, the total number of deaths during the follow up period was 262 (43.2%). The non-revascularized group had a higher mortality rate (n = 61) when compared to the revascularized group (n = 201), respectively (60.0% vs 40.4%, p = 0.004). Revascularization was associated with a fewer deaths or ventricular arrhythmia events in the overall cohort (HR 0.71, 95% CI (0.53, 0.96) p = 0.025). When examining patients by indication for ICD, patients in the revascularization group implanted for secondary prevention had fewer deaths or ventricular arrhythmia events (HR 0.57, 95% CI (0.38,0.86) p = 0.007), whereas no statistically significant association was shown on this outcome in patients in the revascularization group with ICDs for a primary prevention indication (HR 0.83, 95% CI (0.54,1.28) p = 0.39).(Fig. 3a and b) In analysis of the components of the composite outcome, patients with secondary prevention ICDs who underwent revascularization had lower mortality (HR 0.46, 95% CI (0.24,0.86) p = 0.015) and a trend towards fewer ventricular arrhythmia events alone (HR 0.62, 95% CI (0.38, 1.00) p = 0.05).
Table 2
Extent of coronary artery disease at time of ICD implant
Coronary Disease
Prior revascularization
N = 497 (%)
No revascularization
N = 109 (%)
P value
Left main stenosis ≥ 50%
90 (18.1)
3 (2.8)
<  0.0001
Single vessel disease
79 (15.9)
44 (40.4)
<  0.0001
Two vessel disease
104 (20.9)
24 (22.0)
Three vessel disease
182 (36.6)
14 (12.8)
Subcritical disease
40 (8.0)
17 (15.6)
 
A multivariable analysis was performed after adjusting for the following variables: sex, age, ejection fraction, left main or three vessel disease, time to revascularization and creatinine. Based on this analysis, prior revascularization was associated with significantly fewer composite end-point events in the secondary prevention ICD group (HR 0.35 (95% CI 0.16, 0.77) p = 0.009, and HR 0.51 (95% CI 0.32, 0.83) p = 0.007, respectively). However, a non-significant trend towards fewer ventricular arrhythmia events was observed in the secondary prevention group (HR 0.59 (95% CI 0.34, 1.03) p = 0.064). In addition, time to revascularization in the secondary prevention ICD group did not affect mortality, ventricular arrhythmias or composite end-point. In contrast, the primary prevention ICD group, prior revascularization was associated with fewer ventricular arrhythmias (HR 0.50 (95% CI 0.27, 0.96) p = 0.036) but did not affect mortality or composite end point. This is further demonstrated in the forest plot in Fig. 4.

Types of ventricular arrhythmia and association with ischemia

Of the 316 patients who had appropriate therapy, the type of ventricular arrhythmia was available in 291 patients. The majority of patients had monomorphic VT (n = 261, 89.7%), polymorphic VT/VF was present in the remaining (n = 30, 11.3%). There was a greater proportion of patients with PMVT/VF with myocardial ischemia (n = 14, 70%) compared to patients with MMVT (n = 18, 32.7%) (P = 0.007). Three patients (15%) with PMVT/VF and two patients (3.6%) with MMVT underwent further revascularization (P = 0.15), after receiving ICD therapy. In patients presenting with electrical storm; myocardial ischemia was found in 4/7 (57.1%) patients presenting with PMVT/VF compared to 8/23 (34.8%) patients with MMVT storm. Revascularization was performed in one patient (14.3%) with PMVT/VF storm and one patient (4.3%) with MMVT storm.

Discussion

In this large cohort study, we found that a history of revascularization was associated with fewer deaths or recurrent ventricular arrhythmia events in patients with a secondary, but not with a primary prevention indication for ICD. This implies that patients with an established arrhythmia substrate might derive more benefit from revascularization. These findings need to be interpreted with caution as our study is at most hypothesis-generating, and does not demonstrate causality. Nevertheless, we did find in multivariable analysis, that these findings remained significant and that revascularization therapy remains an important consideration in patients who have an ICD.
Prior studies have shown conflicting results. In a cohort study of 274 patients with preserved ejection fraction (EF ≥ 40%), revascularization was not associated with a difference in mortality or recurrent ventricular arrhythmia [19]. In the MADIT-CRT trial, revascularization was found to be associated with a significant reduction in mortality and recurrent ICD therapy [9]. In a post-hoc analysis of the MADIT II study, revascularization demonstrated time dependence, with attenuating benefit as time from coronary revascularization increased [20]. In a post-hoc analysis of the VANISH study, patients with more advanced disease that presented with recurrent ventricular arrhythmia despite antiarrhythmic medications. Furthermore, revascularization was not associated with a difference in clinical outcomes [21]. This suggests that the timing of coronary revascularization may have an association with ventricular arrhythmia burden. In addition, our study suggests that this association was more prominent in those patients who have an established arrhythmia substrate, rather than those with a potential substrate.
The beneficial effects of coronary revascularization could be due to restoration of blood flow to hibernating myocardium which may improve cardiac function and limit the progression of ischemic substrate [22]. It is well known that left main disease is associated with a three year mortality of 50% if revascularization is not performed; the optimal form of revascularization has been coronary artery bypass grafting, however, percutaneous coronary intervention has been shown to provide similar outcomes [23, 24]. The association between revascularization and mortality is dependent on the severity of disease and the presence of disease in the left anterior descending (LAD) territory. Prior data supports revascularization to reduce mortality in two and three vessel disease but is equivocal in single vessel unless it is a proximal LAD lesion [25]. In our study, there was a significant proportion of patients with medium to high risk coronary disease who were not revascularized; this was associated with a higher risk of mortality in the overall cohort. From our study and prior data, revascularization has been shown to reduce mortality, and this corroborates to our findings in this population of patients with ischemic heart disease and ICDs. It is also possible that revascularization reduces myocardial ischemia, which is a common trigger for ventricular arrhythmia. This has a wide spectrum, which included not only polymorphic ventricular tachycardia and ventricular fibrillation [26], but also monomorphic ventricular tachycardia [27, 28]. The decision to perform coronary revascularization is often a complex decision that takes into account multiple factors, including the patient’s condition and comorbidities, myocardial ischemia and viability, as well as the technical feasibility of revascularization. These variables could not be considered in the context of our study as is further discussed in our limitations.
There are a number of variables present in this patient population that could have influenced outcomes. Metabolic syndrome, predominant in patients with Type 2 diabetes, has been associated with worse heart failure outcomes in patients with cardiac resynchronization therapy [29], as well as patients with ischemic heart disease [30]. There was no difference in the rate of diabetes in the two groups, and no influence of diabetes on mortality in the multivariable analysis, but the influence of metabolic syndrome could not be further assessed. The effect of inflammatory markers including C reactive protein, brain natriuretic peptide and emerging markers such as heat shock proteins or ST2 could not be measured in this study, but deserve further work to better elucidate outcomes in patients with ICDs.
Remote monitoring (RM) was not used consistently in this study. RM has been shown to be associated with a reduction in mortality and heart failure outcomes [31, 32], but this has not been borne out in randomized clinical trials, with the exception of the IN-TIME Study [33]. RM has demonstrated reduction in the time to detection of arrhythmia and reduction in inappropriate shocks [34]. Further research into determining the effect of RM on this patient population and its outcomes is required to determine effects on total mortality. In this study, all patients were followed every six months for device follow up, there was no loss to follow up in this cohort. The effect of RM use could not be further assessed in this cohort.
There were approximately 1/5 of the population that had cardiac resynchronization therapy (CRT) devices. Response to CRT has been shown to have effects on clinical outcomes including rate of ventricular arrhythmia and overall prognosis [29, 35]. Nevertheless, there is data that demonstrated no difference in left ventricular reverse remodeling irrespective of revascularization [36]. It is also well known that ischemic cardiomyopathy has a lower rate of CRT response, compared to non-ischemic cardiomyopathy [37]. CRT response rates were not available for analysis in this cohort, and may have affect the rate of ventricular arrhythmias, but given the balanced numbers in the two groups and the lack of finding any effect with multivariable analysis, the magnitude of this effect is likely to be small.

Limitations

There were some limitations to this study. The cause of death was not available for analysis. The study was retrospective in nature, where the decision to perform revascularization was left to physician discretion prior to ICD implantation. The study addressed the revascularization status at the time of the index event, thus there was limited data on revascularization after ICD implantation, with the exception of those with recurrent ICD shocks, as discussed in the results section. The variables considered to perform revascularization were not available for analysis in this dataset, a limitation of the registry. Nevertheless, the concomitant comorbidities that preclude revascularization appear to have an impact on overall mortality, particularly in the secondary prevention group. This finding remains significant and at least provides some indication as to prognosis in this population. Other variables including the effect of metabolic syndrome, heart failure severity, response to cardiac resynchronization therapy, and the use of remote monitoring could not be measured in the groups. Biomarkers such as NT-pro brain natriuretic peptide and C reactive protein, were not in widespread use for prognosis and would have been useful data given its utility in prognostication in this population [30]. An additional limitation is that the power to detect meaningful differences in outcomes in the patients with primary and secondary prevention ICDs as subgroups was limited due to the available sample size in the registry, and overfitting of the Cox models may have occurred. Moreover, myocardial viability was not routinely available in our database for this cohort, but rather a portion of the database; hence, it was not included. The exact cause of death could not be determined, it is possible that death due to cardiac causes was significant in all groups, however, overall mortality remains most important. In addition, since this study spanned 12 years, a temporal effect on mortality and ventricular arrhythmias could be possible but was not evaluated. Finally, selection bias is possible in this study, and causality of ventricular arrhythmia is very unlikely to be related to less complete revascularization alone.

Conclusion

Our study demonstrated that revascularization was associated with significantly lower mortality events alone, and fewer composite end-point of mortality and ventricular arrhythmias in patients with ischemic cardiomyopathy. This finding was most pronounced in patients with a secondary prevention indication for an ICD, compared to those with a primary prevention indication. Revascularization might be beneficial in patients who present with ventricular arrhythmia, and should be considered as an adjunctive therapy to ICD implantation to improve cardiovascular outcomes.

Acknowledgements

Not applicable.

Conflict of interest

Dr. Parkash and Dr. Sapp have received consulting fees from St. Jude and honoraria from Medtronic in the past.
This study was approved by the Nova Scotia Health Authority Research Ethics Board. A waiver of consent was obtained to include the study subjects. Clinical Study IRB Number: 1020495.
Approval Study Date: 2015/10/09.
Not applicable.

Competing interests

Not applicable.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Zipes DP, Wellens HJJ. Sudden cardiac death. Circulation. 1998;98(21):2334–51.CrossRef Zipes DP, Wellens HJJ. Sudden cardiac death. Circulation. 1998;98(21):2334–51.CrossRef
2.
Zurück zum Zitat Myerburg RJ, Junttila MJ. Sudden cardiac death caused by coronary heart disease. Circulation. 2012;125(8):1043–52.CrossRef Myerburg RJ, Junttila MJ. Sudden cardiac death caused by coronary heart disease. Circulation. 2012;125(8):1043–52.CrossRef
3.
Zurück zum Zitat Curtis MJ. Characterisation, utilisation and clinical relevance of isolated perfused heart models of ischaemia-induced ventricular fibrillation. Cardiovasc Res. 1998;39(1):194–215.CrossRef Curtis MJ. Characterisation, utilisation and clinical relevance of isolated perfused heart models of ischaemia-induced ventricular fibrillation. Cardiovasc Res. 1998;39(1):194–215.CrossRef
4.
Zurück zum Zitat Sutton PMI, Taggart P, Opthof T, Coronel R, Trimlett R, Pugsley W, et al. Repolarisation and refractoriness during early ischaemia in humans. Heart. 2000;84(4):365–9.CrossRef Sutton PMI, Taggart P, Opthof T, Coronel R, Trimlett R, Pugsley W, et al. Repolarisation and refractoriness during early ischaemia in humans. Heart. 2000;84(4):365–9.CrossRef
5.
Zurück zum Zitat Myerburg RJ, Kessler KM, Mallon SM, Cox MM, Demarchena E, Interian A Jr, et al. Life-threatening ventricular arrhythmias in patients with silent myocardial ischemia due to coronary artery spasm. N Engl J Med. 1992;326(22):1451–5.CrossRef Myerburg RJ, Kessler KM, Mallon SM, Cox MM, Demarchena E, Interian A Jr, et al. Life-threatening ventricular arrhythmias in patients with silent myocardial ischemia due to coronary artery spasm. N Engl J Med. 1992;326(22):1451–5.CrossRef
6.
Zurück zum Zitat Velazquez EJ, Bonow RO. Revascularization in severe left ventricular dysfunction. J Am Coll Cardiol. 2015;65(6):615–24.CrossRef Velazquez EJ, Bonow RO. Revascularization in severe left ventricular dysfunction. J Am Coll Cardiol. 2015;65(6):615–24.CrossRef
7.
Zurück zum Zitat Velazquez EJ, Lee KL, Deja MA, Jain A, Sopko G, Marchenko A, et al. Coronary-artery bypass surgery in patients with left ventricular dysfunction. N Engl J Med. 2011;364(17):1607–16.CrossRef Velazquez EJ, Lee KL, Deja MA, Jain A, Sopko G, Marchenko A, et al. Coronary-artery bypass surgery in patients with left ventricular dysfunction. N Engl J Med. 2011;364(17):1607–16.CrossRef
8.
Zurück zum Zitat Levine JH, Mellits ED, Baumgardner RA, Veltri EP, Mower M, Grunwald L, et al. Predictors of first discharge and subsequent survival in patients with automatic implantable cardioverter-defibrillators. Circulation. 1991;84(2):558–66.CrossRef Levine JH, Mellits ED, Baumgardner RA, Veltri EP, Mower M, Grunwald L, et al. Predictors of first discharge and subsequent survival in patients with automatic implantable cardioverter-defibrillators. Circulation. 1991;84(2):558–66.CrossRef
9.
Zurück zum Zitat Barsheshet A, Goldenberg I, Narins CR, Moss AJ, McNitt S, Wang PJ, et al. Time dependence of life-threatening ventricular tachyarrhythmias after coronary revascularization in MADIT-CRT. Heart Rhythm. 2010;7(10):1421–7.CrossRef Barsheshet A, Goldenberg I, Narins CR, Moss AJ, McNitt S, Wang PJ, et al. Time dependence of life-threatening ventricular tachyarrhythmias after coronary revascularization in MADIT-CRT. Heart Rhythm. 2010;7(10):1421–7.CrossRef
10.
Zurück zum Zitat Daoud EG, Niebauer M, Kou WH, Man KC, Horwood L, Morady F, et al. Incidence of implantable defibrillator discharges after coronary revascularization in survivors of ischemic sudden cardiac death. Am Heart J. 1995;130(2):277–80.CrossRef Daoud EG, Niebauer M, Kou WH, Man KC, Horwood L, Morady F, et al. Incidence of implantable defibrillator discharges after coronary revascularization in survivors of ischemic sudden cardiac death. Am Heart J. 1995;130(2):277–80.CrossRef
11.
Zurück zum Zitat AUTSCHBACH R, FALK V, CONSKA BD, DALICHAU H. The effect of coronary bypass graft surgery for the prevention of sudden cardiac death: recurrent episodes after ICD implantation and review of literature. Pacing Clin Electrophysiol. 1994;17(3):552–8.CrossRef AUTSCHBACH R, FALK V, CONSKA BD, DALICHAU H. The effect of coronary bypass graft surgery for the prevention of sudden cardiac death: recurrent episodes after ICD implantation and review of literature. Pacing Clin Electrophysiol. 1994;17(3):552–8.CrossRef
12.
Zurück zum Zitat Lessmeier TJ, Lehmann MH, Steinman RT, Fromm BS, Akhtar M, Calkins H, et al. Implantable cardioverter-defibrillator therapy in 300 patients with coronary artery disease presenting exclusively with ventricular fibrillation. Am Heart J. 1994;128(2):211–8.CrossRef Lessmeier TJ, Lehmann MH, Steinman RT, Fromm BS, Akhtar M, Calkins H, et al. Implantable cardioverter-defibrillator therapy in 300 patients with coronary artery disease presenting exclusively with ventricular fibrillation. Am Heart J. 1994;128(2):211–8.CrossRef
13.
Zurück zum Zitat Parkash R, Sapp JL, Basta M, Doucette S, Thompson K, Gardner M, et al. Use of primary prevention implantable Cardioverter-defibrillators in a population-based cohort is associated with a significant survival BenefitClinical perspective. Circ Arrhythm Electrophysiol. 2012;5(4):706–13.CrossRef Parkash R, Sapp JL, Basta M, Doucette S, Thompson K, Gardner M, et al. Use of primary prevention implantable Cardioverter-defibrillators in a population-based cohort is associated with a significant survival BenefitClinical perspective. Circ Arrhythm Electrophysiol. 2012;5(4):706–13.CrossRef
14.
Zurück zum Zitat Tang AS, Wells GA, Talajic M, Arnold MO, Sheldon R, Connolly S, et al. Cardiac-resynchronization therapy for mild-to-moderate heart failure. NEnglJMed. 2010;363(25):2385–95.CrossRef Tang AS, Wells GA, Talajic M, Arnold MO, Sheldon R, Connolly S, et al. Cardiac-resynchronization therapy for mild-to-moderate heart failure. NEnglJMed. 2010;363(25):2385–95.CrossRef
15.
Zurück zum Zitat Zipes DP, Camm AJ, Borggrefe M, Buxton AE, Chaitman B, Fromer M, et al. ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death--executive summary: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Eur Heart J. 2006;27(17):2099–140.CrossRef Zipes DP, Camm AJ, Borggrefe M, Buxton AE, Chaitman B, Fromer M, et al. ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death--executive summary: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Eur Heart J. 2006;27(17):2099–140.CrossRef
16.
Zurück zum Zitat Gillis AM, Philippon F, Cassidy MR, Singh N, Dorian P, Love BA, et al. Guidelines for implantable cardioverter defibrillator follow-up in Canada: a consensus statement of the Canadian working group on cardiac pacing. Can J Cardiol. 2003;19(1):21–37.PubMed Gillis AM, Philippon F, Cassidy MR, Singh N, Dorian P, Love BA, et al. Guidelines for implantable cardioverter defibrillator follow-up in Canada: a consensus statement of the Canadian working group on cardiac pacing. Can J Cardiol. 2003;19(1):21–37.PubMed
17.
Zurück zum Zitat Cygankiewicz I, Gillespie J, Zareba W, Brown MW, Goldenberg I, Klein H, et al. Predictors of long-term mortality in multicenter automatic defibrillator implantation trial II (MADIT II) patients with implantable cardioverter-defibrillators. Heart Rhythm. 2009;6(4):468–73.CrossRef Cygankiewicz I, Gillespie J, Zareba W, Brown MW, Goldenberg I, Klein H, et al. Predictors of long-term mortality in multicenter automatic defibrillator implantation trial II (MADIT II) patients with implantable cardioverter-defibrillators. Heart Rhythm. 2009;6(4):468–73.CrossRef
18.
Zurück zum Zitat Goldenberg I, Moss AJ, McNitt S, Zareba W, Hall WJ, Andrews ML, et al. Time dependence of defibrillator benefit after coronary revascularization in the multicenter automatic defibrillator implantation trial (MADIT)-II. J Am Coll Cardiol. 2006;47(9):1811–7.CrossRef Goldenberg I, Moss AJ, McNitt S, Zareba W, Hall WJ, Andrews ML, et al. Time dependence of defibrillator benefit after coronary revascularization in the multicenter automatic defibrillator implantation trial (MADIT)-II. J Am Coll Cardiol. 2006;47(9):1811–7.CrossRef
19.
Zurück zum Zitat Mondésert B, Khairy P, Schram G, Shohoudi A, Talajic M, Andrade JG, et al. Impact of revascularization in patients with sustained ventricular arrhythmias, prior myocardial infarction, and preserved left ventricular ejection fraction. Heart Rhythm. 2016;13(6):1221–7.CrossRef Mondésert B, Khairy P, Schram G, Shohoudi A, Talajic M, Andrade JG, et al. Impact of revascularization in patients with sustained ventricular arrhythmias, prior myocardial infarction, and preserved left ventricular ejection fraction. Heart Rhythm. 2016;13(6):1221–7.CrossRef
20.
Zurück zum Zitat Barsheshet A, Goldenberg I, Moss AJ, Huang DT, Zareba W, McNITT S, et al. Effect of elapsed time from coronary revascularization to implantation of a Cardioverter defibrillator on long-term survival in the MADIT-II trial. J Cardiovasc Electrophysiol. 2011;22(11):1237–42.CrossRef Barsheshet A, Goldenberg I, Moss AJ, Huang DT, Zareba W, McNITT S, et al. Effect of elapsed time from coronary revascularization to implantation of a Cardioverter defibrillator on long-term survival in the MADIT-II trial. J Cardiovasc Electrophysiol. 2011;22(11):1237–42.CrossRef
21.
Zurück zum Zitat Elsokkari I, Parkash R, Gray CJ, Gardner MJ, AM AW, Doucette S. et al, Effect of coronary revascularization on long term clinical outcomes in patients with ischemic cardiomyopathy and recurrent ventricular arrhythmia. Pacing Clin Electrophysiol. 2018. Elsokkari I, Parkash R, Gray CJ, Gardner MJ, AM AW, Doucette S. et al, Effect of coronary revascularization on long term clinical outcomes in patients with ischemic cardiomyopathy and recurrent ventricular arrhythmia. Pacing Clin Electrophysiol. 2018.
22.
Zurück zum Zitat Allman KC, Shaw LJ, Hachamovitch R, Udelson JE. Myocardial viability testing and impact of revascularization on prognosis in patients with coronary artery disease and left ventricular dysfunction: a meta-analysis. J Am Coll Cardiol. 2002;39(7):1151–8.CrossRef Allman KC, Shaw LJ, Hachamovitch R, Udelson JE. Myocardial viability testing and impact of revascularization on prognosis in patients with coronary artery disease and left ventricular dysfunction: a meta-analysis. J Am Coll Cardiol. 2002;39(7):1151–8.CrossRef
23.
Zurück zum Zitat Collet C, Capodanno D, Onuma Y, Banning A, Stone GW, Taggart DP, et al. Left main coronary artery disease: pathophysiology, diagnosis, and treatment. Nat Rev Cardiol. 2018;15(6):321–31.CrossRef Collet C, Capodanno D, Onuma Y, Banning A, Stone GW, Taggart DP, et al. Left main coronary artery disease: pathophysiology, diagnosis, and treatment. Nat Rev Cardiol. 2018;15(6):321–31.CrossRef
24.
Zurück zum Zitat Stone GW, Kappetein AP, Sabik JF, Pocock SJ, Morice MC, Puskas J, et al. Five-year outcomes after PCI or CABG for left Main coronary disease. N Engl J Med. 2019;381(19):1820–30.CrossRef Stone GW, Kappetein AP, Sabik JF, Pocock SJ, Morice MC, Puskas J, et al. Five-year outcomes after PCI or CABG for left Main coronary disease. N Engl J Med. 2019;381(19):1820–30.CrossRef
25.
Zurück zum Zitat Yusuf S, Zucker D, Peduzzi P, Fisher LD, Takaro T, Kennedy JW, et al. Effect of coronary artery bypass graft surgery on survival: overview of 10-year results from randomised trials by the coronary artery bypass graft surgery Trialists collaboration. Lancet. 1994;344(8922):563–70.CrossRef Yusuf S, Zucker D, Peduzzi P, Fisher LD, Takaro T, Kennedy JW, et al. Effect of coronary artery bypass graft surgery on survival: overview of 10-year results from randomised trials by the coronary artery bypass graft surgery Trialists collaboration. Lancet. 1994;344(8922):563–70.CrossRef
26.
Zurück zum Zitat Benito B, Josephson ME. Ventricular tachycardia in coronary artery disease. Revista Española de Cardiología (English Edition). 2012;65(10):939–55.CrossRef Benito B, Josephson ME. Ventricular tachycardia in coronary artery disease. Revista Española de Cardiología (English Edition). 2012;65(10):939–55.CrossRef
27.
Zurück zum Zitat Rosman J, Hanon S, Shapiro M, Evans SJ, Schweitzer P. Triggers of sustained monomorphic ventricular tachycardia differ among patients with varying etiologies of left ventricular dysfunction. Ann Noninvasive Electrocardiol. 2006;11(2):113–7.CrossRef Rosman J, Hanon S, Shapiro M, Evans SJ, Schweitzer P. Triggers of sustained monomorphic ventricular tachycardia differ among patients with varying etiologies of left ventricular dysfunction. Ann Noninvasive Electrocardiol. 2006;11(2):113–7.CrossRef
28.
Zurück zum Zitat Peters RW, Kim HJ, Buser GA, Gold MR. Ischemically mediated sustained monomorphic ventricular tachycardia. Resolution with anti-ischemic therapy. Chest. 1993;104(5):1613–4.CrossRef Peters RW, Kim HJ, Buser GA, Gold MR. Ischemically mediated sustained monomorphic ventricular tachycardia. Resolution with anti-ischemic therapy. Chest. 1993;104(5):1613–4.CrossRef
29.
Zurück zum Zitat Sardu C, Santamaria M, Funaro S, Sacra C, Barbieri M, Paolisso P, et al. Cardiac electrophysiological alterations and clinical response in cardiac resynchronization therapy with a defibrillator treated patients affected by metabolic syndrome. Medicine (Baltimore). 2017;96(14):e6558. https://doi.org/10.1097/MD.0000000000006558. PMID: 28383431; PMCID: PMC5411215. Sardu C, Santamaria M, Funaro S, Sacra C, Barbieri M, Paolisso P, et al. Cardiac electrophysiological alterations and clinical response in cardiac resynchronization therapy with a defibrillator treated patients affected by metabolic syndrome. Medicine (Baltimore). 2017;96(14):e6558. https://​doi.​org/​10.​1097/​MD.​0000000000006558​. PMID: 28383431; PMCID: PMC5411215.
30.
Zurück zum Zitat Sardu C, Marfella R, Santamaria M, Papini S, Parisi Q, Sacra C, et al. Stretch, Injury and Inflammation Markers Evaluation to Predict Clinical Outcomes After Implantable Cardioverter Defibrillator Therapy in Heart Failure Patients With Metabolic Syndrome. Front Physiol. 2018;9:758.CrossRef Sardu C, Marfella R, Santamaria M, Papini S, Parisi Q, Sacra C, et al. Stretch, Injury and Inflammation Markers Evaluation to Predict Clinical Outcomes After Implantable Cardioverter Defibrillator Therapy in Heart Failure Patients With Metabolic Syndrome. Front Physiol. 2018;9:758.CrossRef
31.
Zurück zum Zitat Saxon LA, Hayes DL, Gilliam FR, Heidenreich PA, Day J, Seth M, et al. Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study. Circulation. 2010;122(23):2359–67.CrossRef Saxon LA, Hayes DL, Gilliam FR, Heidenreich PA, Day J, Seth M, et al. Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study. Circulation. 2010;122(23):2359–67.CrossRef
32.
Zurück zum Zitat Sardu C, Santamaria M, Rizzo MR, Barbieri M, di Marino M, Paolisso G, et al. Telemonitoring in heart failure patients treated by cardiac resynchronisation therapy with defibrillator (CRT-D): the TELECART study. Int J Clin Pract. 2016;70(7):569–76.CrossRef Sardu C, Santamaria M, Rizzo MR, Barbieri M, di Marino M, Paolisso G, et al. Telemonitoring in heart failure patients treated by cardiac resynchronisation therapy with defibrillator (CRT-D): the TELECART study. Int J Clin Pract. 2016;70(7):569–76.CrossRef
33.
Zurück zum Zitat Hindricks G, Taborsky M, Glikson M, Heinrich U, Schumacher B, Katz A, et al. Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial. Lancet. 2014;384(9943):583–90.CrossRef Hindricks G, Taborsky M, Glikson M, Heinrich U, Schumacher B, Katz A, et al. Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial. Lancet. 2014;384(9943):583–90.CrossRef
34.
Zurück zum Zitat Parthiban N, Esterman A, Mahajan R, Twomey DJ, Pathak RK, Lau DH, et al. Remote monitoring of implantable Cardioverter-defibrillators: a systematic review and meta-analysis of clinical outcomes. J Am Coll Cardiol. 2015;65(24):2591–600.CrossRef Parthiban N, Esterman A, Mahajan R, Twomey DJ, Pathak RK, Lau DH, et al. Remote monitoring of implantable Cardioverter-defibrillators: a systematic review and meta-analysis of clinical outcomes. J Am Coll Cardiol. 2015;65(24):2591–600.CrossRef
35.
Zurück zum Zitat Goldstein RE, Haigney MC, Krone RJ, McNitt S, Zareba W, Moss AJ. Differing effects of cardiac resynchronization therapy on long-term mortality in patient subgroups of MADIT-CRT defined by baseline conduction and 1-year post-treatment left ventricular remodeling. Heart Rhythm. 2013;10(3):366–73.CrossRef Goldstein RE, Haigney MC, Krone RJ, McNitt S, Zareba W, Moss AJ. Differing effects of cardiac resynchronization therapy on long-term mortality in patient subgroups of MADIT-CRT defined by baseline conduction and 1-year post-treatment left ventricular remodeling. Heart Rhythm. 2013;10(3):366–73.CrossRef
36.
Zurück zum Zitat Husaini M, Biton Y, Stair B, Moss AJ, Biering-Sorensen T, Solomon S, et al. Effectiveness of cardiac resynchronization therapy by the frequency of revascularization procedures in ischemic cardiomyopathy patients. Cardiol J. 2016;23(4):437–45.CrossRef Husaini M, Biton Y, Stair B, Moss AJ, Biering-Sorensen T, Solomon S, et al. Effectiveness of cardiac resynchronization therapy by the frequency of revascularization procedures in ischemic cardiomyopathy patients. Cardiol J. 2016;23(4):437–45.CrossRef
37.
Zurück zum Zitat Barsheshet A, Goldenberg I, Moss AJ, Eldar M, Huang DT, McNitt S, et al. Response to preventive cardiac resynchronization therapy in patients with ischaemic and nonischaemic cardiomyopathy in MADIT-CRT. Eur Heart J. 2011;32(13):1622–30.CrossRef Barsheshet A, Goldenberg I, Moss AJ, Eldar M, Huang DT, McNitt S, et al. Response to preventive cardiac resynchronization therapy in patients with ischaemic and nonischaemic cardiomyopathy in MADIT-CRT. Eur Heart J. 2011;32(13):1622–30.CrossRef
Metadaten
Titel
The effect of revascularization on mortality and risk of ventricular arrhythmia in patients with ischemic cardiomyopathy
verfasst von
Ahmad Alkharaza
Mousa Al-Harbi
Ihab El-sokkari
Steve Doucette
Ciorsti MacIntyre
Christopher Gray
Amir Abdelwahab
John L. Sapp
Martin Gardner
Ratika Parkash
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
BMC Cardiovascular Disorders / Ausgabe 1/2020
Elektronische ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-020-01726-4

Weitere Artikel der Ausgabe 1/2020

BMC Cardiovascular Disorders 1/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.