Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 12/2014

01.12.2014 | Symposium: ABJS Carl T. Brighton Workshop on Implant Wear and Tribocorrosion of Total Joint Replacements

The Surgical Options and Clinical Evidence for Treatment of Wear or Corrosion Occurring With THA or TKA

verfasst von: Charles A. Engh Jr, MD, Henry Ho, MSc, Douglas E. Padgett, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 12/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Wear and corrosion occurring in patients with hip and knee arthroplasty are common causes of failure leading to revision surgery. A variety of surgical approaches to these problems have been described, with varying efficacy. Polyethylene wear, metal-on-metal (MoM) hip bearing wear, and problems associated with modular taper corrosion are the areas of greatest clinical impact; results of revisions for these problems are likely to dictate a large portion of revision resources for the foreseeable future, and so they call for specific study.

Questions/purposes

We identified the most frequently reported procedures to treat hip polyethylene wear, knee polyethylene wear, MoM wear after THA, and modular taper corrosion and determined the timing and reasons these failed.

Methods

We performed systematic reviews of the published literature on the four topics using MEDLINE® and Embase in October 2013; searches were supplemented by hand searches of bibliographies. Prespecified criteria resulted in the identification of 38 relevant articles, of which 33 were either case reports or Level IV evidence. Followup was generally at short term and ranged from 0.2 to 8 years.

Results

The most frequently reported procedures for treating clinically important wear were a partial or complete revision. When treating polyethylene wear, the more frequently reported reasons for hip and knee rerevisions were loosening, continued wear, and instability. Soft tissue reactions were more common and occasionally extensive in patients with MoM or modular taper corrosion. Patients with soft tissue reactions had more complications and higher rerevision rates.

Conclusions

Studies with longer followup and higher levels of evidence are needed to direct the treatment of wear and corrosion. When soft tissue damage secondary to MoM wear or taper corrosion is present, the results of treatment can be poor. There is an urgent need to better understand these two mechanisms of failure.
Literatur
2.
Zurück zum Zitat Babis GC, Trousdale RT, Morrey BF. The effectiveness of isolated tibial insert exchange in revision total knee arthroplasty. J Bone Joint Surg Am. 2002;84:64–68.PubMed Babis GC, Trousdale RT, Morrey BF. The effectiveness of isolated tibial insert exchange in revision total knee arthroplasty. J Bone Joint Surg Am. 2002;84:64–68.PubMed
3.
Zurück zum Zitat Bae DK, Song SJ, Heo DB, Lee SH, Song WJ. Long-term survival rate of implants and modes of failure after revision total knee arthroplasty by a single surgeon. J Arthroplasty. 2013;28:1130–1134.PubMedCrossRef Bae DK, Song SJ, Heo DB, Lee SH, Song WJ. Long-term survival rate of implants and modes of failure after revision total knee arthroplasty by a single surgeon. J Arthroplasty. 2013;28:1130–1134.PubMedCrossRef
4.
Zurück zum Zitat Ball ST, Severns D, Linn M, Meyer RS, Swenson FC. What happens to serum metal ion levels after a metal-on-metal bearing is removed? J Arthroplasty. 2013;28(8 suppl):53–55.PubMedCrossRef Ball ST, Severns D, Linn M, Meyer RS, Swenson FC. What happens to serum metal ion levels after a metal-on-metal bearing is removed? J Arthroplasty. 2013;28(8 suppl):53–55.PubMedCrossRef
5.
Zurück zum Zitat Blom AW, Astle L, Loveridge J, Learmonth ID. Revision of an acetabular liner has a high risk of dislocation. J Bone Joint Surg Br. 2005;87:1636–1638.PubMedCrossRef Blom AW, Astle L, Loveridge J, Learmonth ID. Revision of an acetabular liner has a high risk of dislocation. J Bone Joint Surg Br. 2005;87:1636–1638.PubMedCrossRef
6.
Zurück zum Zitat Boucher HR, Lynch C, Young AM, Engh CA Jr, Engh C Sr. Dislocation after polyethylene liner exchange in total hip arthroplasty. J Arthroplasty. 2003;18:654–657.PubMedCrossRef Boucher HR, Lynch C, Young AM, Engh CA Jr, Engh C Sr. Dislocation after polyethylene liner exchange in total hip arthroplasty. J Arthroplasty. 2003;18:654–657.PubMedCrossRef
7.
Zurück zum Zitat Bragdon C, Burke D, Ekeledo A, Freiberg A, Greene M, Harris W, Malchau H. Seven to ten year follow-up of highly cross-linked polyethylene liners in total hip arthroplasty. J Bone Joint Surg Br. 2010;92:511. Bragdon C, Burke D, Ekeledo A, Freiberg A, Greene M, Harris W, Malchau H. Seven to ten year follow-up of highly cross-linked polyethylene liners in total hip arthroplasty. J Bone Joint Surg Br. 2010;92:511.
8.
Zurück zum Zitat Callaghan JJ, Reynolds ER, Ting NT, Goetz DD, Clohisy JC, Maloney WJ. Liner exchange and bone grafting: rare option to treat wear and lysis of stable TKAs. Clin Orthop Relat Res. 2011;469:154–159.PubMedCentralPubMedCrossRef Callaghan JJ, Reynolds ER, Ting NT, Goetz DD, Clohisy JC, Maloney WJ. Liner exchange and bone grafting: rare option to treat wear and lysis of stable TKAs. Clin Orthop Relat Res. 2011;469:154–159.PubMedCentralPubMedCrossRef
9.
Zurück zum Zitat Chana R, Esposito C, Campbell PA, Walter WK, Walter WL. Mixing and matching causing taper wear: corrosion associated with pseudotumour formation. J Bone Joint Surg Br. 2012;94:281–286.PubMedCrossRef Chana R, Esposito C, Campbell PA, Walter WK, Walter WL. Mixing and matching causing taper wear: corrosion associated with pseudotumour formation. J Bone Joint Surg Br. 2012;94:281–286.PubMedCrossRef
10.
Zurück zum Zitat Cooper HJ, Della Valle CJ, Berger RA, Tetreault M, Paprosky WG, Sporer SM, Jacobs JJ. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012;94:1655–1661.PubMed Cooper HJ, Della Valle CJ, Berger RA, Tetreault M, Paprosky WG, Sporer SM, Jacobs JJ. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012;94:1655–1661.PubMed
11.
Zurück zum Zitat De Haan R, Campbell PA, Su EP, De Smet KA. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br. 2008;90:1158–1163.PubMedCrossRef De Haan R, Campbell PA, Su EP, De Smet KA. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br. 2008;90:1158–1163.PubMedCrossRef
12.
Zurück zum Zitat De Smet KA, Van Der Straeten C, Van Orsouw M, Doubi R, Backers K, Grammatopoulos G. Revisions of metal-on-metal hip resurfacing: lessons learned and improved outcome. Orthop Clin North Am. 2011;42:259–269.PubMedCrossRef De Smet KA, Van Der Straeten C, Van Orsouw M, Doubi R, Backers K, Grammatopoulos G. Revisions of metal-on-metal hip resurfacing: lessons learned and improved outcome. Orthop Clin North Am. 2011;42:259–269.PubMedCrossRef
13.
Zurück zum Zitat Engh CA Jr, Hopper RH Jr, Huynh C, Ho H, Sritulanondha S, Engh CA Sr. A prospective, randomized study of cross-linked and non-cross-linked polyethylene for total hip arthroplasty at 10-year follow-up. J Arthroplasty. 2012;27(8 suppl):2–7.e1. Engh CA Jr, Hopper RH Jr, Huynh C, Ho H, Sritulanondha S, Engh CA Sr. A prospective, randomized study of cross-linked and non-cross-linked polyethylene for total hip arthroplasty at 10-year follow-up. J Arthroplasty. 2012;27(8 suppl):2–7.e1.
14.
Zurück zum Zitat Engh CA Jr, Parks NL, Engh GA. Polyethylene quality affects revision knee liner exchange survivorship. Clin Orthop Relat Res. 2012;470:193–198.PubMedCentralPubMedCrossRef Engh CA Jr, Parks NL, Engh GA. Polyethylene quality affects revision knee liner exchange survivorship. Clin Orthop Relat Res. 2012;470:193–198.PubMedCentralPubMedCrossRef
15.
Zurück zum Zitat Engh GA, Koralewicz LM, Pereles TR. Clinical results of modular polyethylene insert exchange with retention of total knee arthroplasty components. J Bone Joint Surg Am. 2000;82:516–523.PubMed Engh GA, Koralewicz LM, Pereles TR. Clinical results of modular polyethylene insert exchange with retention of total knee arthroplasty components. J Bone Joint Surg Am. 2000;82:516–523.PubMed
16.
Zurück zum Zitat Garbuz DS, Hargreaves BA, Duncan CP, Masri BA, Wilson DR, Forster BB. The John Charnley Award. Diagnostic accuracy of MRI versus ultrasound for detecting pseudotumors in asymptomatic metal-on-metal THA. Clin Orthop Relat Res. 2014;472:417–423.PubMedCrossRef Garbuz DS, Hargreaves BA, Duncan CP, Masri BA, Wilson DR, Forster BB. The John Charnley Award. Diagnostic accuracy of MRI versus ultrasound for detecting pseudotumors in asymptomatic metal-on-metal THA. Clin Orthop Relat Res. 2014;472:417–423.PubMedCrossRef
17.
Zurück zum Zitat Garbuz DS, Masri BA, Duncan CP, Greidanus NV, Bohm ER, Petrak MJ, Della Valle CJ, Gross AE. The Frank Stinchfield Award. Dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial? Clin Orthop Relat Res. 2012;470:351–356.PubMedCentralPubMedCrossRef Garbuz DS, Masri BA, Duncan CP, Greidanus NV, Bohm ER, Petrak MJ, Della Valle CJ, Gross AE. The Frank Stinchfield Award. Dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial? Clin Orthop Relat Res. 2012;470:351–356.PubMedCentralPubMedCrossRef
18.
Zurück zum Zitat Grammatopoulos G, Pandit H, Kwon YM, Gundle R, McLardy-Smith P, Beard DJ, Murray DW, Gill HS. Hip resurfacing revised for inflammatory pseudotumour have a poor outcome. J Bone Joint Surg Br. 2009;91:1019–1024.CrossRef Grammatopoulos G, Pandit H, Kwon YM, Gundle R, McLardy-Smith P, Beard DJ, Murray DW, Gill HS. Hip resurfacing revised for inflammatory pseudotumour have a poor outcome. J Bone Joint Surg Br. 2009;91:1019–1024.CrossRef
19.
Zurück zum Zitat Griffin WL, Fehring TK, Mason JB, McCoy TH, Odum S, Terefenko CS. Early morbidity of modular exchange for polyethylene wear and osteolysis. J Arthroplasty. 2004 19(7 suppl):61–66.PubMedCrossRef Griffin WL, Fehring TK, Mason JB, McCoy TH, Odum S, Terefenko CS. Early morbidity of modular exchange for polyethylene wear and osteolysis. J Arthroplasty. 2004 19(7 suppl):61–66.PubMedCrossRef
20.
Zurück zum Zitat Griffin WL, Scott RD, Dalury DF, Mahoney OM, Chiavetta JB, Odum SM. Modular insert exchange in knee arthroplasty for treatment of wear and osteolysis. Clin Orthop Relat Res. 2007;464:132–137.PubMed Griffin WL, Scott RD, Dalury DF, Mahoney OM, Chiavetta JB, Odum SM. Modular insert exchange in knee arthroplasty for treatment of wear and osteolysis. Clin Orthop Relat Res. 2007;464:132–137.PubMed
21.
Zurück zum Zitat Hamilton WG, Hopper RH, Engh CA, Engh CA. Survivorship of polyethylene liner exchanges performed for the treatment of wear and osteolysis among porous-coated cups. J Arthroplasty. 2010;25(suppl 6):75–80.PubMedCrossRef Hamilton WG, Hopper RH, Engh CA, Engh CA. Survivorship of polyethylene liner exchanges performed for the treatment of wear and osteolysis among porous-coated cups. J Arthroplasty. 2010;25(suppl 6):75–80.PubMedCrossRef
22.
Zurück zum Zitat Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson B, Skinner JA. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg Br. 2011;93:1308–1313.PubMedCrossRef Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson B, Skinner JA. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg Br. 2011;93:1308–1313.PubMedCrossRef
23.
Zurück zum Zitat Hsu AR, Gross CE, Levine BR. Pseudotumor from modular neck corrosion after ceramic-on-polyethylene total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2012;41:422–426.PubMed Hsu AR, Gross CE, Levine BR. Pseudotumor from modular neck corrosion after ceramic-on-polyethylene total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2012;41:422–426.PubMed
24.
Zurück zum Zitat Kemp MA, Mitra A, da Costa TM, Spencer RF. Bearing exchange in the management of pseudotumours. Ann R Coll Surg Engl. 2013;95:266–270.PubMedCrossRef Kemp MA, Mitra A, da Costa TM, Spencer RF. Bearing exchange in the management of pseudotumours. Ann R Coll Surg Engl. 2013;95:266–270.PubMedCrossRef
25.
Zurück zum Zitat Koh KH, Moon YW, Lim SJ, Lee HI, Shim JW, Park YS. Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty. Arch Orthop Trauma Surg. 2011;131:1591–1600.PubMedCrossRef Koh KH, Moon YW, Lim SJ, Lee HI, Shim JW, Park YS. Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty. Arch Orthop Trauma Surg. 2011;131:1591–1600.PubMedCrossRef
26.
Zurück zum Zitat Kwon YM, Lombardi AV, Jacobs JJ, Fehring TK, Lewis CG, Cabanela ME. Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg Am. 2014;96:e4.PubMedCrossRef Kwon YM, Lombardi AV, Jacobs JJ, Fehring TK, Lewis CG, Cabanela ME. Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg Am. 2014;96:e4.PubMedCrossRef
27.
Zurück zum Zitat Lachiewicz PF, Soileau ES. Liner exchange in total knee arthroplasty. J Surg Orthop Adv. 2013;22:152–156.PubMedCrossRef Lachiewicz PF, Soileau ES. Liner exchange in total knee arthroplasty. J Surg Orthop Adv. 2013;22:152–156.PubMedCrossRef
28.
Zurück zum Zitat Liddle AD, Satchithananda K, Henckel J, Sabah SA, Vipulendran KV, Lewis A, Skinner JA, Mitchell AW, Hart AJ. Revision of metal-on-metal hip arthroplasty in a tertiary center: a prospective study of 39 hips with between 1 and 4 years of follow-up. Acta Orthop. 2013;84:237–245.PubMedCentralPubMedCrossRef Liddle AD, Satchithananda K, Henckel J, Sabah SA, Vipulendran KV, Lewis A, Skinner JA, Mitchell AW, Hart AJ. Revision of metal-on-metal hip arthroplasty in a tertiary center: a prospective study of 39 hips with between 1 and 4 years of follow-up. Acta Orthop. 2013;84:237–245.PubMedCentralPubMedCrossRef
29.
Zurück zum Zitat Lindgren JU, Brismar BH, Wikstrom AC. Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis. J Bone Joint Surg Br. 2011;93:1427–1430.PubMedCrossRef Lindgren JU, Brismar BH, Wikstrom AC. Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis. J Bone Joint Surg Br. 2011;93:1427–1430.PubMedCrossRef
30.
Zurück zum Zitat Maezawa K, Nozawa M, Matsuda K, Sugimoto M, Shitoto K, Kurosawa H. Serum chromium levels before and after revision surgery for loosened metal-on-metal total hip arthroplasty. J Arthroplasty. 2009;24:549–553.PubMedCrossRef Maezawa K, Nozawa M, Matsuda K, Sugimoto M, Shitoto K, Kurosawa H. Serum chromium levels before and after revision surgery for loosened metal-on-metal total hip arthroplasty. J Arthroplasty. 2009;24:549–553.PubMedCrossRef
31.
Zurück zum Zitat Maloney WJ, Paprosky W, Engh CA, Rubash H. Surgical treatment of pelvic osteolysis. Clin Orthop Relat Res. 2001;393:78–84.PubMedCrossRef Maloney WJ, Paprosky W, Engh CA, Rubash H. Surgical treatment of pelvic osteolysis. Clin Orthop Relat Res. 2001;393:78–84.PubMedCrossRef
32.
Zurück zum Zitat Mao X, Tay GH, Godbolt DB, Crawford RW. Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty. J Arthroplasty. 2012;27:493.e13–e17. Mao X, Tay GH, Godbolt DB, Crawford RW. Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty. J Arthroplasty. 2012;27:493.e13–e17.
33.
Zurück zum Zitat McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD. Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2009;91:773–782.PubMedCrossRef McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD. Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2009;91:773–782.PubMedCrossRef
34.
Zurück zum Zitat Munro JT, Masri BA, Duncan CP, Garbuz DS. High complication rate after revision of large-head metal-on-metal total hip arthroplasty. Clin Orthop Relat Res. 2014;472:523–528.PubMedCrossRef Munro JT, Masri BA, Duncan CP, Garbuz DS. High complication rate after revision of large-head metal-on-metal total hip arthroplasty. Clin Orthop Relat Res. 2014;472:523–528.PubMedCrossRef
35.
Zurück zum Zitat Nawabi DH, Hayter CL, Su EP, Koff MF, Perino G, Gold SL, Koch KM, Potter HG. Magnetic resonance imaging findings in symptomatic versus asymptomatic subjects following metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Am. 2013;95:895–902.PubMedCrossRef Nawabi DH, Hayter CL, Su EP, Koff MF, Perino G, Gold SL, Koch KM, Potter HG. Magnetic resonance imaging findings in symptomatic versus asymptomatic subjects following metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Am. 2013;95:895–902.PubMedCrossRef
36.
Zurück zum Zitat O’Brien JJ, Burnett RS, McCalden RW, MacDonald SJ, Bourne RB, Rorabeck CH. Isolated liner exchange in revision total hip arthroplasty: clinical results using the direct lateral surgical approach. J Arthroplasty. 2004;19:414–423.PubMedCrossRef O’Brien JJ, Burnett RS, McCalden RW, MacDonald SJ, Bourne RB, Rorabeck CH. Isolated liner exchange in revision total hip arthroplasty: clinical results using the direct lateral surgical approach. J Arthroplasty. 2004;19:414–423.PubMedCrossRef
37.
Zurück zum Zitat Pansard E, Fouilleron N, Dereudre G, Migaud H, Girard J. Severe corrosion after malpositioning of a metallic head over the Morse taper of a cementless hip arthroplasty: a case report. Orthop Traumatol Surg Res. 2012;98:247–250.PubMedCrossRef Pansard E, Fouilleron N, Dereudre G, Migaud H, Girard J. Severe corrosion after malpositioning of a metallic head over the Morse taper of a cementless hip arthroplasty: a case report. Orthop Traumatol Surg Res. 2012;98:247–250.PubMedCrossRef
38.
Zurück zum Zitat Pritchett JW. One-component revision of failed hip resurfacing from adverse reaction to metal wear debris. J Arthroplasty. 2014;29:219–224.PubMedCrossRef Pritchett JW. One-component revision of failed hip resurfacing from adverse reaction to metal wear debris. J Arthroplasty. 2014;29:219–224.PubMedCrossRef
39.
Zurück zum Zitat Restrepo C, Ghanem E, Houssock C, Austin M, Parvizi J, Hozack WJ. Isolated polyethylene exchange versus acetabular revision for polyethylene wear. Clin Orthop Relat Res. 2009;467:194–198.PubMedCentralPubMedCrossRef Restrepo C, Ghanem E, Houssock C, Austin M, Parvizi J, Hozack WJ. Isolated polyethylene exchange versus acetabular revision for polyethylene wear. Clin Orthop Relat Res. 2009;467:194–198.PubMedCentralPubMedCrossRef
40.
Zurück zum Zitat Schelfaut S, Cool S, Mulier M. The use of structural periacetabular allografts in acetabular revision surgery: 2.5–5 years follow-up. Arch Orthop Trauma Surg. 2009;129:455–461.PubMedCrossRef Schelfaut S, Cool S, Mulier M. The use of structural periacetabular allografts in acetabular revision surgery: 2.5–5 years follow-up. Arch Orthop Trauma Surg. 2009;129:455–461.PubMedCrossRef
41.
Zurück zum Zitat Tower SS. Arthroprosthetic cobaltism: neurological and cardiac manifestations in two patients with metal-on-metal arthroplasty: a case report. J Bone Joint Surg Am. 2010;92:2847–2851.PubMedCrossRef Tower SS. Arthroprosthetic cobaltism: neurological and cardiac manifestations in two patients with metal-on-metal arthroplasty: a case report. J Bone Joint Surg Am. 2010;92:2847–2851.PubMedCrossRef
42.
Zurück zum Zitat Scully WF, Teeny SM. Pseudotumor associated with metal-on-polyethylene total hip arthroplasty. Orthopedics. 2013;36:e666–e670.PubMedCrossRef Scully WF, Teeny SM. Pseudotumor associated with metal-on-polyethylene total hip arthroplasty. Orthopedics. 2013;36:e666–e670.PubMedCrossRef
43.
Zurück zum Zitat Van der Weegen W, Sijbesma T, Hoekstra HJ, Brakel K, Pilot P, Nelissen RG. Treatment of pseudotumors after metal-on-metal hip resurfacing based on magnetic resonance imaging, metal ion levels and symptoms. J Arthroplasty. 2014;29:416–421.PubMedCrossRef Van der Weegen W, Sijbesma T, Hoekstra HJ, Brakel K, Pilot P, Nelissen RG. Treatment of pseudotumors after metal-on-metal hip resurfacing based on magnetic resonance imaging, metal ion levels and symptoms. J Arthroplasty. 2014;29:416–421.PubMedCrossRef
44.
Zurück zum Zitat Verhelst LA, Van der Bracht H, Vanhegan IS, Van Backlé B, De Schepper J. Revising the well-fixed, painful resurfacing using a double-mobility head: a new strategy to address metal-on-metal complications. J Arthroplasty. 2012;27:1857–1862.PubMedCrossRef Verhelst LA, Van der Bracht H, Vanhegan IS, Van Backlé B, De Schepper J. Revising the well-fixed, painful resurfacing using a double-mobility head: a new strategy to address metal-on-metal complications. J Arthroplasty. 2012;27:1857–1862.PubMedCrossRef
45.
Zurück zum Zitat Wade FA, Rapuri VR, Parvizi J, Hozack WJ. Isolated acetabular polyethylene exchange through the anterolateral approach. J Arthroplasty. 2004;19:498–500.PubMedCrossRef Wade FA, Rapuri VR, Parvizi J, Hozack WJ. Isolated acetabular polyethylene exchange through the anterolateral approach. J Arthroplasty. 2004;19:498–500.PubMedCrossRef
46.
Zurück zum Zitat Werner SD, Bono JV, Nandi S, Ward DM, Talmo CT. Adverse tissue reactions in modular exchangeable neck implants: a report of two cases. J Arthroplasty. 2013;28:543.e13–e15. Werner SD, Bono JV, Nandi S, Ward DM, Talmo CT. Adverse tissue reactions in modular exchangeable neck implants: a report of two cases. J Arthroplasty. 2013;28:543.e13–e15.
47.
Zurück zum Zitat Whitehouse MR, Endo M, Masri BA. Adverse local tissue reaction associated with a modular hip hemiarthroplasty. Clin Orthop Relat Res. 2013;471:4082–4086.PubMedCrossRef Whitehouse MR, Endo M, Masri BA. Adverse local tissue reaction associated with a modular hip hemiarthroplasty. Clin Orthop Relat Res. 2013;471:4082–4086.PubMedCrossRef
48.
Zurück zum Zitat Wyles CC, Van Demark RE 3rd, Sierra RJ, Trousdale RT. High rate of infection after aseptic revision of failed metal-on-metal total hip arthroplasty. Clin Orthop Relat Res. 2014;472:509–516.PubMedCrossRef Wyles CC, Van Demark RE 3rd, Sierra RJ, Trousdale RT. High rate of infection after aseptic revision of failed metal-on-metal total hip arthroplasty. Clin Orthop Relat Res. 2014;472:509–516.PubMedCrossRef
Metadaten
Titel
The Surgical Options and Clinical Evidence for Treatment of Wear or Corrosion Occurring With THA or TKA
verfasst von
Charles A. Engh Jr, MD
Henry Ho, MSc
Douglas E. Padgett, MD
Publikationsdatum
01.12.2014
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 12/2014
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-014-3652-4

Weitere Artikel der Ausgabe 12/2014

Clinical Orthopaedics and Related Research® 12/2014 Zur Ausgabe

Symposium: 2013 Limb Lengthening and Reconstruction Society

Internal Lengthening Device for Congenital Femoral Deficiency and Fibular Hemimelia

Symposium: ABJS Carl T. Brighton Workshop on Implant Wear and Tribocorrosion of Total Joint Replacements

What is the Trouble With Trunnions?

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.