The use of PEEK in digital prosthodontics: A narrative review

verfasst von: Ioannis Papathanasiou, Phophi Kamposiora, George Papavasiliou, Marco Ferrari

Erschienen in: BMC Oral Health | Ausgabe 1/2020

Abstract

Background

Advanced computer-aided design and computer-aided manufacturing (CAD-CAM) technology led to the introduction of an increasing number of machinable materials suitable for dental prostheses. One of these materials is polyetheretherketone (PEEK), a high performance polymer recently used in dentistry with favorable physical, mechanical and chemical properties. The purpose of this study was to review the current published literature on the use of PEEK for the fabrication of dental prostheses with CAD-CAM techniques.

Methods

Electronic database searches were performed using the terms “PEEK”, “CAD-CAM”, “dental”, “dentistry” to identify studies related to the use of PEEK for the fabrication of CAD-CAM prostheses. The search period spanned from January 1990 through February 2020. Both in vivo and in vitro studies in English were eligible. Review articles and the references of the included publications were searched to identify relevant articles.

Results

A great number of in vitro studies are available in the current literature pointing out the noticeable properties of PEEK. The use of PEEK has been recommended for a wide range of CAD-CAM fabricated fixed and removable dental prostheses. PEEK was additionally recommended for occlusal splints, intra-radicular posts, implant abutments, customized healing abutments and provisional restorations. However, only a few clinical studies were identified.

Conclusions

PEEK could be considered as a viable alternative for CAD-CAM fixed and removable dental prostheses to well-established dental materials. Due to the scarcity of clinical data, clinical trials are needed to assess the long-term performance of PEEK prostheses.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
PEEK
Polyetheretherketone
CAD
Computer-assisted-design
CAM
Computer-assisted-manufacturing
FDP
Fixed Dental Prosthesis
IFDP
Implant-supported Fixed Dental Prosthesis
RDP
Removable Dental Prosthesis
PMMA
Poly (methyl methacrylate)
Ti
Titanium
ZrO2
Zirconia
CoCr
Cobalt-Chromium
CoCrMo
Cobalt-Chromium-Molybdenum

Background

The rapid evolution of computer-aided design and computer-aided manufacturing (CAD-CAM) technology led to the introduction of new materials that could be precisely milled for the fabrication of dental prostheses [1]. Polyetheretherketone (PEEK) is a linear, aromatic, semi-crystalline thermoplastic, high performance polymer recently used in dentistry as a framework material for metal-free fixed dental prostheses [1, 2], removable dental prostheses [3], implant-supported fixed prostheses [4], implant-retained overdentures [5], endocrowns [6] and resin bonded fixed dental prostheses [7]. It has been also used for the manufacturing of dental implants [8], implant abutments [9], healing abutments [10] and occlusal splints [11]. PEEK is a material with high biocompatibility, good mechanical properties, high temperature resistance, chemical stability, polishability, good wear resistance, low plaque affinity and high bond strength with veneering composites and luting cements. Compared to rigid framework materials such as zirconium oxide and metal alloys, PEEK has a low modulus of elasticity of 4 GPa, and is as elastic as bone, providing a cushioning effect and reduction of stresses transferred to the abutment teeth [1220]. Although PEEK is becoming widespread in clinical practice, only a few studies are available focusing on the use of this material for CAD-CAM prostheses. The purpose of this study was to review the current published literature on CAD-CAM PEEK dental prostheses.

Methods

A literature search was conducted using several electronic databases (MEDLINE, PubMed, Scopus) for studies related to the use of PEEK for the fabrication of CAD-CAM prostheses. The search terms that the reviewers used alone or in combination were “PEEK”, “CAD-CAM”, “dental”, “dentistry”. The search period spanned from January 1990 through February 2020. Initially, the reviewers screened titles, abstracts or both for relevance according to the inclusion criterion, which was studies on PEEK prostheses. Both in vitro and in vivo studies were eligible in this review. Studies in a language other than English or without an English-language abstract were excluded. The reviewers obtained the full text of all relevant articles that passed the first review phase. The option of related-articles searches was also used. At this point, reviewers searched the references of the selected studies and review articles to identify relevant articles, which provided with few papers from years before 1990 as well. Reviewers tabulated data from the included studies. The following information was obtained from the included publications: author(s), year of publication, study design, type of PEEK prosthesis or application, number of specimens or patients and main outcomes/findings.

Results

Fixed dental prostheses (FDPs)

PEEK is a relatively new material with favorable mechanical properties and good bonding with veneering composite materials that fulfills the basic requirements to be used as a framework material for fixed dental prostheses [2022]. Table 1 and Table 2 summarize the main findings of the in vitro and in vivo studies included in this review.
Table 1
In vitro studies included in the review
Study (year)
Application
Materials tested
Outcomes
Stawarczyk et al. (2015) [20]
FDPs
CAD-CAM milled PEEK
Pressed pellet PEEK
Pressed granular PEEK (n = 15/group)
Higher mean fracture load (2.354 N) for milled FPDs than those pressed from granular PEEK (1.738 N)
Stawarczyk et al. (2013) [22]
CAD-CAM PEEK (n = 225)
Μean fracture load of 1383 N Plastic deformation starting approximately at 1200 N
Niem et al.(2019) [23]
CAD-CAM PEEK
Zirconia
Lithium disilicate glass-ceramic (n = 10/group)
PEEK exhibited
higher modulus of resilience than lithium disilicate
Comparable to that of gold alloy
Niem et al. (2019) [24]
CAD-CAM PEEK
Ceramic
Composite and
Polymer-based materials
(n = 10 /group)
Flexural strength and modulus of elasticity of PEEK not significantly influenced by thermocycling
Liebermann et al. (2016) [25]
PEEK
Hybrid material
Composite resins
PMMA-based materials (n = 40/group)
PEEK demonstrated:
The lowest solubility and water absorption
Similar hardness parameters to PMMA-based materials
Taufall et al. (2016) [26]
CAD-CAM PEEK veneered with different methods
(digital veneering, conventional veneering with crea.lign, conventional with crea.lign paste, and pre-manufactured veneers) (n = 30/group)
The digital veneering showed the
highest fracture load resistance
Cekic-Nagas et al. (2018) [27]
CAD-CAM PEEK
PMMA
Composite resin and fiber-reinforced composite materials (n = 7/group)
Highest load bearing capacity for PEEK
Wimmer et al. (2016) [28]
CAD-CAM PEEK
Nanohybrid composite
PMMA-based material
(n = 12/ group)
Significantly higher wear resistance for PEEK
Wachtel et al. (2019) [29]
IFDPs
CAD-CAM PEEK screw-retained crowns on titanium implants (n = 10)
Favorable fracture mode for PEEK compared to conventional materials
Coronal displacement of bending points
No screw loosening or veneer fracture
Sirandoni et al. (2019) [30]
CAD-CAM PEEK
PMMA
Zzirconia
Co-Cr
Ti
Highest deformation for PEEK and PMMA frameworks that decreased von Mises stresses in the frameworks, implants and abutments
PEEK exhibited critical tensile stress values in the trabecular bone
Nazari et al. (2016) [31]
CAD-CAM PEEK
Zirconia
Nickel-chromium alloy (n = 10/group)
3-unit IFDPs on two implants
Failure loads:
Zirconia 2086 ± 362 N
nickel-chromium alloy 5591 ± 1200 N
PEEK 1430 ± 262 N
Elsayed et al. (2019) [32]
CAD-CAM PEEK
Zirconia
Lithium disilicate crowns supported by titanium and zirconia implant abutments (n = 8/group)
High fracture resistance of PEEK crowns, comparable to zirconia and lithium disilicate
Jin et al. (2019) [33]
CAD-CAM PEEK and titanium frameworks veneered with composite resin n = 20/group
PEEK exhibited
Higher shear bond strength than Ti, good marginal fit and fracture resistance (1518 N)
Preis et al. (2017) [1]
CAD-CAM PEEK
Zirconia-reinforced lithium silicate ceramics
Composite resins
Zirconia
(n = 8/group)
PEEK molar implant-supported crowns showed lower fracture resistance than zirconia crowns
Total failure rate of PEEK screw-retained frameworks veneered with composite paste
Yilmaz et al. (2018) [34]
Seven different CAD-CAM HPPs 100% PEEK
80% PEEK with 20% filler
80% PEKK with 20% filler Ceramic reinforced PEEK Interlaced fiberglass and resin Fiber-composite material
New generation cubic zirconia 3Y-TZP Zirconia
Higher fracture resistance for zirconia implant-supported frameworks with cantilevers than PEEK-based materials
Ghodsi et al. (2018) [35]
CAD-CAM PEEK
Zirconia
Composite
(n = 12/group)
No clinically acceptable marginal gaps for PEEK
No significant differences observed in retention forces
Zeighami et al. (2019) [36]
CAD-CAM PEEK
Zirconia,
Composite (n = 12/group)
Better marginal adaptation for zirconia than PEEK
Chen et al. (2019) [37]
RPDs
CAD-CAM PEEK
Co-Cr
Ti alloys
PEEK caused lower stresses on periodontal ligament and higher stresses on the mucosa
Tribst et al. (2020) [38]
PEEK
Polyamide
Polyoxymethylene
Gold alloy
Titanium
CoCr
Polyoxymethylene and PEEK exhibited the lowest retentive forces
Peng et al. (2019) [39]
PEEK
CoCr alloy
No significant difference in the long-term deformation
Muhsin et al. (2018) [40]
CAD-CAM PEEK
granular PEEK
Co-Cr casting alloy
(n = 10/group)
Higher retentive force for milled PEEK clasps than thermopressed clasps
Higher retentive forces for PEEK clasps at deeper undercuts with a thicker clasp design than Co-Cr clasps after 3 years of fatigue simulation
Negm et al. (2019) [41]
CAD-CAM Milled PEEK Thermo-pressed PEEK (n = 10/group)
Higher fit and trueness for directly milled frameworks
Arnold et al. (2018) [42]
CAD-CAM Milled PEEK
Cast metal frameworks with different techniques (n = 12/group)
PEEK RPD frameworks have better precision and fit than metal frameworks fabricated using different techniques
Hada et al. (2020) [43]
Complete denture framework
PEEK
Fiber-reinforced composite
Nano-zirconia
cobalt-chromium-molybdenum alloy (n = 6group)
PEEK provides lower reinforcement than the other materials
Emera et al. (2019) [5]
Double-crown-retained Removable Dental Prostheses
Zirconia or PEEK primary crowns
Zirconia or PEEK secondary crowns
Telescopic attachments fabricated from zirconia primary crowns and PEEK secondary crowns exhibited the lowest stresses transmitted to the implants
Schubert et al. (2019) [44]
Implant-supported zirconia primary crowns with
electroformed secondary crowns or CAD-CAM PEEK secondary crowns (n = 10/group)
Stable retentive force values over 10 years of simulated aging for PEEK secondary crowns
Merk et al. (2016) [45]
Zirconia primary crowns
Secondary PEEK crowns of different taper and manufacturing methods;
milled from PEEK blanks; thermo-pressed from PEEK pellets;
thermo-pressed from granular PEEK (n = 10/group)
Fabrication method and taper angle had no consistent effect on retentive forces within different groups
Stock et al. (2016) [46]
Zirconia primary crowns
Secondary PEEK crowns of different taper and manufacturing methods;
milled from PEEK blanks; thermo-pressed from PEEK pellets;
thermo-pressed from granular PEEK (n = 30/group)
Milled 0° tapered PEEK crowns presented the lowest retention force
Milled 2° tapered PEEK crowns had the highest retention force values
Retention force of pressed PEEK not influenced by the taper angle
Decrease of retention after the first twenty pull-off cyclew for pressed PEEK
Wagner et al. (2018) [47]
PEEK telescopic crowns and cobalt chrome copings of different taper and manufacturing methods (n = 10/group)
Stable retention load values for each test group
Stock et al. (2016) [48]
Milled PEEK primary and cobalt-chromium (CoCr), zirconia (ZrO2) and galvanic
(GAL) secondary crowns with three different tapers (n = 30, 10/taper)
Milled PEEK can be used as primary crown material with high retentive forces in combination with secondary zirconia, cobalt-chromium or electroformed crowns
Benli et al. (2020) [11]
Occlusal splint
CAD-CAM PEEK
Vinyl acetate
Polymethyl methacrylate
Polycarbonate
Polyethyleneterephthalate
(n = 12/group)
After chewing simulation PEEK occlusal splints exhibited lower loss of volume and lower roughness alteration compared to other CAD-CAM materials
Benli et al. (2020) [49]
Intra-radicular posts
Milled PEEK
Glass-fiber
Cast-metal
(n = 20/group)
PEEK posts exhibited the highest tensile bond strength and the lowest surface roughness
Kaleli et al. (2018) [9]
Implant abutments
PEEK and zirconia customized abutments
Finite element analysis showed higher stress values in restorative crowns for PEEK abutments
Abdullah et al. (2016) [50]
Provisional crowns
PEEK
VITA CAD Temp
Telio CAD-Temp
Protemp 4
PEEK demonstrated superior fit and fracture strength than other materials
Table 2
Clinical studies included in the review
Study (Year)
Study design
Intervention
Outcome
Parmigiani-Izquierdo et al. (2017) [51]
Case report
Zirconia implants restored with milled PEEK frameworks veneered with composite resin for the replacement of upper molars
Cushioning of occlusal loads while chewing
Viable solution for patients with intolerance to metal alloys
Cabello-Dominguez et al. (2019) [52]
Case report
Monolithic zirconia fixed prosthesis in the maxilla and PEEK framework with gingival composite resin combined with lithium disilicate crowns in the mandible for the rehabilitation of a completely edentulous patient
The reduced weight and modulus of elasticity of PEEK could reduce the risk of mechanical complications
Higher cost than metal-ceramic or metal-acrylic restoration
Zoidis (2018) [4]
Case report
PEEK implant framework material in combination with prefabricated
PMMA veneers for the fabrication of a complete maxillary arch implant-supported fixed restoration
Esthetic outcome comparable with that of ceramic restoration
After 2 years, no sign of screw loosening,
veneering material chipping, wear, or staining
Harb et al. (2019) [53]
Case report
Milled PEEK framework combined with acrylic resin denture teeth and heat-cured acrylic resin denture for Kennedy Class I RPD fabrication
Adequate fit and good patient satisfaction in terms of function and esthetics
Costa-Palau et al. (2014) [54]
Case report
Milled PEEK framework for the fabrication of a maxillary obturator prosthesis
Compared to conventional obturators
PEEK frameworks permit the fabrication of lighter prostheses with improved retention, function and esthetics
Mangano et al. (2019) [55]
Clinical study
Combining Intraoral and Face Scans for the Design and Fabrication of
CAD-CAM PEEK Implant-Supported Bars for Maxillary Overdentures (15 patients)
After a year in function
100% implant survival
80% success rate
Spies et al. (2018) [56]
Case report
Implant-supported overdenture with the receptor part of the bar milled from PEEK polymerized into a zirconia framework for the rehabitation of an edentulous patient
High patient satisfaction with function and esthetics after 6 months
Hahnel et al. (2018) [57]
Case report
Primary CoCr copings and secondary CAD-CAM PEEK framework veneered with composite resin for the fabrication of double-crown-retained interim removable dental prosthesis
Biocompatibilityand low weight
no complications after 3 months
Siewert (2018) [58]
Case report
Primary zirconia copings and secondary PEEK framework veneered with monolithic zirconia for the rehabilitation of an edentulous patient with intolerance to titanium
High chewing comfort
Dampening of chewing forces
Beretta et al. (2019) [10]
Randomized clinical trial
Comparison of CAD-CAM fabricated customized healing abutments and standard healing caps placed at the surgical stage for the creation of the desired emergence profile (n = 10/group)
After a healing period of 1–3 months
Patients with PEEK customized healing abutments showed higher functional implant prosthodontics score (FIPS) and lower numerical rating scale (NRS) values
Although there are no clinical reports on CAD-CAM fabricated PEEK FDPs available in the literature, Stawarczyk et al. in an in vitro study found that three-unit fixed dental prostheses milled using CAD-CAM technology from pre-pressed PEEK blanks showed lower deformation and higher fracture loads (2354 N) than those pressed in granular form (1738 N) [20]. Furthermore, several in vitro studies claimed that PEEK could be a viable alternative for single crowns and fixed dental prostheses [2226]. Three-unit PEEK frameworks demonstrated deformation of the FDPs at 1200 N and fracture in the connector of the FDPs at 1383 N [22]. If 870 N is considered the average maximum posterior mastication force [59] PEEK could be regarded as a suitable material for restorations in load bearing areas. Moreover, the fracture resistance of the CAD-CAM milled PEEK FDPs is much higher than those of lithium disilicate glass-ceramic (950 N), alumina (851 N) and zirconia (981-1331 N) [60, 61]. Another in vitro study testing different types of inlay-retained FDPs, found that PEEK had the highest load bearing capacity compared to PMMA, composite resin paste and fiber-reinforced composite materials [27].
Compared to zirconia, lithium disilicate, and a high-content gold alloy, PEEK presented a higher value for the modulus of resilience than lithium disilicate, comparable to that of gold alloy, indicating a high capability to elastically absorb destructive fracture energy [23]. Based on the stress-strain curves observed, a high capacity to dissipate energy plastically was also found. Furthermore, PEEK has a low modulus of elasticity (4 GPa) compared to chrome-cobalt alloys (220 GPa), gold alloys (91 GPa), zirconia (220 GPa), alumina (314 GPa) and lithium dissilicate (95 GPa), zirconia reinforced lithium silicate (70 GPa), Feldspathic porcelain (48,7 GPa) [62]. A 3D-Finite Element Analysis of monolithic full posterior crowns revealed that materials with higher elastic modulus present higher tensile stress concentration on the crown intaglio surface and higher shear stress on the cement layer that could facilitate crown debonding in oral conditions [62]. Due to its low modulus of elasticity, PEEK allows the absorption of functional stresses by deformation and acts as stress breaker reducing forces transferred to the abutment teeth [2, 6]. For this reason, two clinical reports suggested the use of a pressed PEEK based framework veneered with light polymerized composite resin for the fabrication of single crown or endocrown in cases of weakened or severely damaged abutment tooth, patient’s allergy to metals and parafunctional habits [2, 6].
In an attempt to assess longevity of restorative materials, Niem et al. evaluated the influence of thermocycling on mechanical properties of ceramic, composite and polymer-based materials. Flexural strength and modulus of elasticity of PEEK were not significantly influenced by thermocycling, indicating the material’s ability to preserve its properties [24]. After aging in different solutions, PEEK demonstrated the lowest solubility and water absorption values compared to composite resins, a hybrid material and PMMA-based materials and similar hardness parameters to PMMA-based materials [25].
PEEK frameworks have a grayish-brown or pearl-white opaque color and need to be veneered with a composite resin. Several studies on bond strength of PEEK with composite resins have proposed different pre-treatments such as airborne-particle abrasion, silica coating [63], piranha-etching [64], sulfuric acid [65], phosphoric acid or argon plasma [66] with conflicting results. However, most of the studies concluded that reliable bond strength to composite veneering resins and luting cements can be achieved when PEEK surfaces are pretreated and conditioned using adhesive systems containing methylmethac-monomers, such as Signum PEEK bond and Visio.link [6771].
Several veneering methods are available; CAD-CAM fabricated veneers, conventional veneering with light polymerized composite resin and pre-manufactured veneers. Taufall et al. evaluated the fracture load of PEEK three-unit fixed dental prostheses veneered with different methods. The highest fracture load values were found for digital veneers, indicating that digital veneering is more reliable than conventional techniques. Adhesive failures were most common for pre-manufactured veneers while cracks in the pontic region starting from the connector area were observed for digital veneers and conventional composite resin [26].
An in vitro study evaluated the colorimetric properties of different veneering materials on PEEK, zirconium oxide (ZrO2), cobalt–chromium–molybdenum alloy (CoCrMo), and titanium oxide. PEEK showed comparable results when compared to well established core materials such as ZrO2 and CoCrMo with respect to the CieLab-System parameters of the assemblies and the modification of the CieLab-System parameters for each veneering material [72].
Additional advantages of PEEK are the low abrasiveness to enamel and the high wear resistance. In an in vitro study, Wimmer et al. found significantly higher wear resistance for PEEK than a nanohybrid composite and a poly (methyl methacrylate) material when loaded laterally and comparable wear of enamel antagonists [28].
The overall conclusion of the previous studies is that PEEK can be used for CAD-CAM FDPs due to its good mechanical and bonding properties, although clinical evidence needs to be improved.

Implant-supported fixed dental prostheses (IFDPs)

Frameworks for implant-supported fixed dental prostheses are typically fabricated by casting metal alloys or milling either titanium or zirconia. However, two recent clinical reports have presented PEEK frameworks veneered with composite resin as a solution for IFDPs, suitable for patients experiencing metal allergies [4, 51]. Another clinical report suggested the use of monolithic zirconia fixed prosthesis in the maxilla and PEEK framework with gingival composite resin combined with lithium disilicate crowns in the mandible for the rehabilitation of a completely edentulous patient. PEEK frameworks have reduced weight and higher elasticity than zirconia frameworks, which could reduce the risk of mechanical complications, but this solution has a higher cost compared to conventional metal-ceramic or metal-acrylic restorations [52].
Due to its low elastic modulus PEEK provides a cushioning effect on occlusal forces. When such an elastic framework is combined with materials with low elastic modulus such as poly (methyl methacrylate) (PMMA) pre-fabricated veneers or veneering composite resin, it will further reduce occlusal forces to the restoration and the opposing dentition. Therefore, the use of PEEK could be advantageous for IFDPs where proprioception is reduced by the absence of periodontal ligaments and eliminate mechanical complications such as veneer fractures and clicking sound during function reported for metal-ceramic or monolithic zirconia restorations [4, 52]. In agreement with this statement, an in vitro study evaluating screw-retained PEEK crowns on titanium implants found favorable fracture mode for PEEK compared to conventional materials while bending points were displaced coronally, providing protection from damage to the implant and the abutment screws [29]. No screw loosening, or veneer complication was found. On the other hand, the use of rigid frameworks fabricated by metal or zirconia could lead to plastic deformation of the implant shoulder [73, 74]. These results are in consistency with the in vitro study of Kaleli et al. reporting higher stress values of zirconia customized abutments on implant components, crown and cortical bone, compared to PEEK customized abutments [9]. Moreover, a three-dimensional finite element analysis on different framework materials for implant-supported fixed mandibular prostheses found the highest deformation for PEEK and PMMA frameworks that decreased von Mises stresses in the frameworks, implants and abutments. However, PEEK frameworks showed critical tensile stress values in the trabecular bone, while ZrO2, Co-Cr, and Ti reached stress values in the bone within physiologic limits [30].
Adequate fracture resistance is required to ensure good long-term outcomes of implant-supported prostheses. An in vitro study evaluating three-unit IFDPs on two implants fabricated by zirconia, nickel-chromium alloy, or PEEK found failure loads of 2086 ± 362 N, 5591 ± 1200 N and 1430 ± 262 N, respectively [31]. However, the fracture strength reported for PEEK prostheses was higher than the physiological maximum posterior masticatory of 870 N [59]. Thus, PEEK prostheses have been considered capable to withstand occlusal forces in the molar region while the failure mode observed was adhesive between veneering composite and framework [31]. El Sayed et al. found high fracture resistance of PEEK crowns, comparable to zirconia and lithium disilicate crowns supported by titanium and zirconia implant abutments [32]. Adequate fracture resistance values of 1518 ± 134 N have also been found by Jin et al. in an in vitro study [33]. On the other hand, Preis et al. in a fatigue testing of PEEK molar crowns either bonded or screw-retained found lower fracture resistance than zirconia ones, while a total failure rate was observed for PEEK frameworks veneered with composite paste used for screw-retained restorations, indicating that the insertion of screw channels weakened the PEEK frameworks [1]. Moreover, zirconia implant-supported frameworks with cantilevers showed higher fracture resistance than PEEK-based materials [34].
Clinically acceptable marginal gap is considered to be less than 120 μm while acceptable marginal adaptation has been suggested to be between 50 and 100 μm. Ghodsi et al. found in an vitro study no clinically acceptable marginal gaps for PEEK and composite implant-supported copings while zirconia had the best marginal and internal adaptation. However, no significant differences were observed in retention forces among materials evaluated with pull-out test [35]. In another study the marginal adaptation of PEEK implant-supported frameworks before and after cementation has been on the borderline of clinical acceptability but with significantly higher marginal discrepancy than zirconia frameworks [36]. On the other hand, Jin et al. found good marginal fit values of 19 ± 4 μm for PEEK three-unit implant-supported frameworks [33], in agreement with the results of Wachtel et al. who reported no bacterial leakage of screw-retained PEEK crowns during masticatory simulation [29].
Chipping of the veneering materials is a common complication of IFDPs with a titanium framework. A previous in vitro study reported stronger bonding of PEEK three-unit implant-supported frameworks (31.1 ± 3.5 MPa) with composite resins than titanium frameworks (20.5 ± 1.8 MPa), concluding that PEEK could be used as an alternative framework material to titanium [1]. Durable bonding of PEEK with composite resins permits, also, easy intraoral repair of PEEK restorations with composite resin in case of chipping [4].
Additional advantages of PEEK is its radiolucency, which may facilitate cement removal and screw loosening diagnosis and its low specific weight permitting the construction of lighter prostheses [4]. Due to the white color of PEEK frameworks, the grayish appearance of metal frameworks can be eliminated and a high esthetic outcome can be achieved in combination with composite veneering materials. Furthermore, PEEK has good biocompatibility combined with low water solubility and high chemical and thermal stability. Thus, PEEK prostheses could be suitable for patients experiencing allergies to metals and metallic taste and for patients demanding metal-free restorations [4]. However, more clinical studies are needed to evaluate the behavior of these new material.

Removable dental prostheses (RDPs)

Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques can be also used to fabricate RDP frameworks. A previous clinical report has suggested PEEK frameworks combined with acrylic resin denture teeth and heat-cured acrylic resin denture bases as an alternative to conventional Co-Cr frameworks [53]. PEEK presents favorable properties such as excellent biocompatility, good mechanical properties, good thermal and chemical resistance, white color and low specific weight that permit the fabrication of lighter metal-free RPDs eliminating the esthetically unacceptable display of metal claps and the risk for metallic taste and allergies of conventional RDP metal frameworks [3, 53]. Another study described the use of milled PEEK frameworks for the fabrication of a removable maxillary obturator prosthesis [54]. Both studies reported high patient satisfaction with regard to esthetics, retention and comfort [53, 54].
Due to its high elasticity, PEEK could reduce stresses and distal torque on the abutment teeth during function [3]. In agreement with this statement, a three-dimensional finite element analysis of Chen et al. found that PEEK frameworks caused lower stress values on periodontal ligament than cobalt-chromium and Ti-6Al-4 V alloy. Thus, PEEK RPDs could be recommended for patients with poor periodontal conditions [37]. However in the same study, it was found that PEEK caused the highest stresses on the mucosa and the greatest displacement on the free-end that could lead to pain, advanced bone resorption, denture base failure and compromised chewing efficiency [37]. The authors concluded that PEEK should be used with caution in distal extension RDPs. Moreover, compared to metal frameworks, PEEK ones showed significantly lower internal stresses.
Retention force and fatigue resistance are crucial factors for RDP clasps. Two in vitro studies found that PEEK clasps exhibited lower retentive force than Co-Cr alloy clasps [38]. However, retention force values of PEEK clasps were considered sufficient for clinical use, while Tannous et al. recommended the use of 0,5 mm undercuts [75]. No significant differences were found in deformation of PEEK and metal clasps after fatigue testing [39]. On the other side, Tribst et al. claimed that PEEK should not be used for clasp fabrication because stress values during removal of clasps with higher undercuts are higher than the material strength [38]. With respect to fabrication method of PEEK frameworks, milled PEEK clasps demonstrated higher retentive force than thermo-pressed ones. Both milled and thermo-pressed PEEK clasps showed higher retaining forces at deeper undercuts with a thicker clasp desing than Co-Cr clasps after 3 years of fatigue simulation [40].
CAD-CAM PEEK RDP frameworks can be fabricated by several methods such as direct milling of PEEK blanks or 3D printing of a resin/wax pattern framework which is then thermo-pressed using the conventional lost-wax/resin technique [41]. Clinically acceptable fit values were found for both techniques but directly milled PEEK frameworks had higher fit and trueness values than indirectly fabricated frameworks. In agreement with this result, Arnold et al. found that directly milled PEEK RPD frameworks have better precision and fit (43 ± 23 mm horizontal, and 38 ± 21 mm vertical) than cast metal frameworks fabricated using the conventional lost-wax casting technique, indirect rapid prototyping or direct rapid prototyping. This was attributed to the high-quality finish achieved by the milling technique [42].
PEEK could also be used as a framework material for complete dentures in order to decrease denture deformation responsible for midline fractures [43, 76]. However, PEEK frameworks with a thickness of 1 mm could offer only a slight reinforcement to complete dentures, while more rigid materials such as fiber-reinforced composite (FRC), nano-zirconia (N–Zr), cobalt-chromium-molybdenum alloy provide greater reinforcement with a thickness of 0,5 mm [43]. This finding can be explained by the similar deformation of PEEK and PMMA due to their compararable elastic moduli which are 4 GPa [19] and 2.7 GPa [77], respectively. Muhsin et al. evaluated denture bases fabricated by milled or thermo-pressed PEEK and PMMA. The results of this in vitro study showed that PEEK denture bases had higher impact and tensile strength than PMMA. Thus, PEEK could be regarded as a material suitable for denture bases providing resistance to notch concentration and fracture [78]. Futhermore, two in vitro studies found better stain resistance and lower surface roughness after polishing of PEEK materials compared with PMMA [79, 80].
Furthermore, a few studies stated that PEEK may be used as an attachment retaining implant-supported overdentures [55, 56]. In a clinical study of Mangano et al., 15 fully edentulous patients were rehabilitated with a maxillary overdenture supported by 4 implants and CAD-CAM fabricated PEEK bar. After a year in function, no implants were lost and an 80% success rate for implant-supported overdentures was found [55]. A clinical report also suggested the use of an implant-supported overdenture with the receptor part of the bar milled from PEEK polymerized into a zirconia framework for the rehabitation of an edentulous patient. The authors reported high patient satisfaction with function and esthetics after 6 months [56].

Double-crown-retained removable dental prostheses

A case report of Hahnel et al. suggested the use of primary metal copings and secondary CAD-CAM PEEK framework veneered with composite resin for the fabrication of double-crown-retained interim removable dental prosthesis [57]. Another case report described the use of primary zirconia copings and secondary PEEK framework veneered with monolithic zirconia for the rehabilitation of an edentulous patient with intolerance to titanium [58]. The study reported high chewing comfort and patient satisfaction with low weight, very good fit and retention. According to Emera et al. telescopic attachments fabricated from zirconia primary crowns and PEEK secondary crowns could also be a viable solution for retaining implant overdentures, providing a reduction of stresses transmitted to the implants due to the stress-breaking capacity of PEEK [5].
Several in vitro studies tested retention forces of double crown systems with primary zirconia crowns and secondary PEEK crowns. An in vitro study found that secondary PEEK crowns provide stable retentive forces after 10 years of simulated aging and comparable values at baseline with well-established electroformed crowns [44]. Another advantage of digitally fabricated telescopic crowns is that in case of loss of retention or other technical complication any part of the double crown system can be reproduced using the stored data. Merk et al. evaluated retention between zirconia primary crowns and secondary PEEK crowns of different taper and manufacturing methods; milled from PEEK blanks; thermo-pressed from PEEK pellets; thermo-pressed from granular PEEK. The outcomes of the study showed that the fabrication method and taper angle had no consistent effect on retentive forces within different groups. However, with regard to retention, PEEK could be considered as viable solution for double-crown-retained RDPs with primary zirconia crowns [45]. In a similar study, Stock et al. found that milled 0° tapered PEEK crowns presented the lowest retention force, whereas milled 2° tapered PEEK crowns had the highest retention force values. The retention force of the pressed PEEK crowns was not influenced by the taper angle [46]. However, pressed PEEK groups showed a decrease of retention after the first twenty pull-off cycles. The explanation given by the authors was that the higher elasticity of pressed PEEK leads to a slight deformation during the removal of the secondary crowns. Thus, precise milling of PEEK blanks could be a more predicable technique for double crown systems [46]. The same conclusions were reached by Wagner et al. who studied the retention between PEEK telescopic crowns and cobalt chrome copings of different taper and manufacturing methods [47]. Another in vitro study demonstrated that milled PEEK could be also used as primary crown material with high retentive forces in combination with secondary zirconia, cobalt-chromium or electroformed crowns [48].

Occlusal splints, intra-radicular posts, implant abutments, healing abutments and provisional restorations

The use of PEEK was additionally recommended for CAD-CAM fabricated occlusal splints. An in vitro study of Benli et al. found lower loss of volume and change in roughness for PEEK occlusal splints after chewing simulation compared to other CAD-CAM materials such as vinyl acetate (EVA), polymethyl methacrylate (PMMA), polycarbonate (PC), and polyethyleneterephthalate (PETG) [11]. It was also claimed that milled PEEK intra-radicular posts could be an alternative to glass-fiber and cast-metal posts. According to an in vitro study, PEEK posts presented higher tensile bond strength than metal and glass-fiber posts when used with the appropriate surface treatment and adhesive system [49]. Previous studies evaluated the performance of PEEK for CAD-CAM fabricated implant abutments, customized healing abutments and provisional crowns [9, 10, 50]. A finite element analysis comparing PEEK and zirconia customized abutments found higher stress values in restorative crowns for PEEK abutments [9]. A randomized clinical trial of Beretta et al. evaluated the use of CAD-CAM fabricated customized healing abutments and standard healing caps placed at the surgical stage for the creation of the desired emergence profile. After a healing period of 1–3 months PEEK customized healing abutments created a natural gingival architecture and required less prosthetic steps for the formation of the emergence profile compared to the use of standard healing caps [10]. Last but not least, Abdullah et al. in an in vitro study compared CAD-CAM provisional crowns with direct provisional crowns. The materials used were VITA CAD Temp, PEEK, Telio CAD-Temp, and Protemp 4. Based on the results of this study, digitally produced PEEK provisional restorations demonstrated better fit and fracture strength than conventional provisional crowns [50].

Conclusions

Several in vitro studies and clinical reports suggested that PEEK could be suitable for CAD-CAM fabricated fixed and removable dental prostheses due to its favorable mechanical, chemical and physical properties. However, further in vitro and clinical studies are needed to evaluate the long-term performance of these prostheses before PEEK can be safely recommended as an alternative to well-established prosthodontic materials.

Acknowledgments

Not applicable.
Not applicable because the present study is a review.
Not applicable.

Competing interests

The authors declare that they have no competing interests in relation to the present work.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Preis V, Hahnel S, Behr M, Bein L, Rosentritt M. In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater. 2017;33(4):427–33.PubMed Preis V, Hahnel S, Behr M, Bein L, Rosentritt M. In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater. 2017;33(4):427–33.PubMed
2.
Zurück zum Zitat Zoidis P, Bakiri E, Papathanasiou I, Zappi A. Modified PEEK as an alternative crown framework material for weak abutment teeth: a case report. Gen Dent. 2017;65(5):37–40.PubMed Zoidis P, Bakiri E, Papathanasiou I, Zappi A. Modified PEEK as an alternative crown framework material for weak abutment teeth: a case report. Gen Dent. 2017;65(5):37–40.PubMed
3.
Zurück zum Zitat Zoidis P, Papathanasiou I, Polyzois G. The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses. A clinical report. J Prosthodont. 2016;25(7):580–4.PubMed Zoidis P, Papathanasiou I, Polyzois G. The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses. A clinical report. J Prosthodont. 2016;25(7):580–4.PubMed
4.
Zurück zum Zitat Zoidis P. The all-on-4 modified polyetheretherketone treatment approach: a clinical report. J Prosthet Dent. 2018;119(4):516–21.PubMed Zoidis P. The all-on-4 modified polyetheretherketone treatment approach: a clinical report. J Prosthet Dent. 2018;119(4):516–21.PubMed
5.
Zurück zum Zitat Emera RM, Altonbary GY, Elbashir SA. Comparison between all zirconia, all PEEK, and zirconia-PEEK telescopic attachments for two implants retained mandibular complete overdentures: in vitro stress analysis study. J Dent Implant. 2019;9:24–9. Emera RM, Altonbary GY, Elbashir SA. Comparison between all zirconia, all PEEK, and zirconia-PEEK telescopic attachments for two implants retained mandibular complete overdentures: in vitro stress analysis study. J Dent Implant. 2019;9:24–9.
6.
Zurück zum Zitat Zoidis P, Bakiri E, Polyzois G. Using modified polyetheretherketone (PEEK) as an alternative material for endocrown restorations: a short-term clinical report. J Prosthet Dent. 2017;117(3):335–9.PubMed Zoidis P, Bakiri E, Polyzois G. Using modified polyetheretherketone (PEEK) as an alternative material for endocrown restorations: a short-term clinical report. J Prosthet Dent. 2017;117(3):335–9.PubMed
7.
Zurück zum Zitat Zoidis P, Papathanasiou I. Modified PEEK resin-bonded fixed dental prosthesis as an interim restoration after implant placement. J Prosthet Dent. 2016;116(5):637–41.PubMed Zoidis P, Papathanasiou I. Modified PEEK resin-bonded fixed dental prosthesis as an interim restoration after implant placement. J Prosthet Dent. 2016;116(5):637–41.PubMed
8.
Zurück zum Zitat Schwitalla A, Müller WD. PEEK dental implants: a review of the literature. J Oral Implantol. 2013;39:743–9.PubMed Schwitalla A, Müller WD. PEEK dental implants: a review of the literature. J Oral Implantol. 2013;39:743–9.PubMed
9.
Zurück zum Zitat Kaleli N, Sarac D, Külünk S, Öztürk Ö. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study. J Prosthet Dent. 2018;119(3):437–45.PubMed Kaleli N, Sarac D, Külünk S, Öztürk Ö. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study. J Prosthet Dent. 2018;119(3):437–45.PubMed
10.
Zurück zum Zitat Beretta M, Poli PP, Pieriboni S, Tansella S, Manfredini M, Cicciù M, et al. Peri-implant soft tissue conditioning by means of customized healing abutment: a randomized controlled clinical trial. Materials (Basel). 2019;12(18):3041. Beretta M, Poli PP, Pieriboni S, Tansella S, Manfredini M, Cicciù M, et al. Peri-implant soft tissue conditioning by means of customized healing abutment: a randomized controlled clinical trial. Materials (Basel). 2019;12(18):3041.
11.
Zurück zum Zitat Benli M, Eker Gümüş B, Kahraman Y, Gökçen-Rohlig B, Evlioğlu G, Huck O, et al. Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers. Odontology. 2020;108(2):240–50.PubMed Benli M, Eker Gümüş B, Kahraman Y, Gökçen-Rohlig B, Evlioğlu G, Huck O, et al. Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers. Odontology. 2020;108(2):240–50.PubMed
12.
Zurück zum Zitat Seferis JC. Polyetheretherketone (PEEK): processing-structure and properties studies for a matrix in high performance composites. Polym Compos. 1986;7:158–69. Seferis JC. Polyetheretherketone (PEEK): processing-structure and properties studies for a matrix in high performance composites. Polym Compos. 1986;7:158–69.
13.
Zurück zum Zitat Katzer A, Marquardt H, Westendorf J, et al. Polyetheretherketone–cytotoxicity and mutagenicity in vitro. Biomaterials. 2002;23:1749–59.PubMed Katzer A, Marquardt H, Westendorf J, et al. Polyetheretherketone–cytotoxicity and mutagenicity in vitro. Biomaterials. 2002;23:1749–59.PubMed
14.
Zurück zum Zitat Rivard CH, Rhalmi S, Coillard C. In vivo biocompatibility testing of peek polymer for a spinal implant system: a study in rabbits. J Biomed Mater Res. 2002;62:488–98.PubMed Rivard CH, Rhalmi S, Coillard C. In vivo biocompatibility testing of peek polymer for a spinal implant system: a study in rabbits. J Biomed Mater Res. 2002;62:488–98.PubMed
15.
Zurück zum Zitat Kistler F, Adler S, Kistler S, et al. PEEK-Hochleistungskunststoffe implantat-prothetischen workflow. Implantologie J. 2013;7:17–42. Kistler F, Adler S, Kistler S, et al. PEEK-Hochleistungskunststoffe implantat-prothetischen workflow. Implantologie J. 2013;7:17–42.
16.
Zurück zum Zitat Adler S, Kistler S, Kistler F, et al. Compression-moulding rather than milling: a wealth of possible applications for high performance polymers. Quintessenz Zahntech. 2013;39:376–84. Adler S, Kistler S, Kistler F, et al. Compression-moulding rather than milling: a wealth of possible applications for high performance polymers. Quintessenz Zahntech. 2013;39:376–84.
17.
Zurück zum Zitat Neugebauer J, Adler S, Kisttler F, et al. The use of plastics in fixed prosthetic implant restoration. ZWR- German Dent J. 2013;122:242–5. Neugebauer J, Adler S, Kisttler F, et al. The use of plastics in fixed prosthetic implant restoration. ZWR- German Dent J. 2013;122:242–5.
18.
Zurück zum Zitat Siewert B, Parra M. A new group of material in dentistry. Peek as a framework material used in 12-piece implant-supported bridges. Z Zahnarzt Implantol. 2013;29:148–59. Siewert B, Parra M. A new group of material in dentistry. Peek as a framework material used in 12-piece implant-supported bridges. Z Zahnarzt Implantol. 2013;29:148–59.
19.
Zurück zum Zitat Alexakou E, Damanaki M, Zoidis P, Bakiri E, Mouzis N, Smidt G, et al. PEEK high performance polymers: a review of properties and clinical applications in prosthodontics and restorative dentistry. Eur J Prosthodont Restor Dent. 2019;27(3):113–21.PubMed Alexakou E, Damanaki M, Zoidis P, Bakiri E, Mouzis N, Smidt G, et al. PEEK high performance polymers: a review of properties and clinical applications in prosthodontics and restorative dentistry. Eur J Prosthodont Restor Dent. 2019;27(3):113–21.PubMed
20.
Zurück zum Zitat Stawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR. Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J. 2015;34(1):7–12.PubMed Stawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR. Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J. 2015;34(1):7–12.PubMed
21.
Zurück zum Zitat Schwitalla AD, Spintig T, Kallage I, Müller WD. Flexural behavior of PEEK materials for dental application. Dent Mater. 2015;31(11):1377–84.PubMed Schwitalla AD, Spintig T, Kallage I, Müller WD. Flexural behavior of PEEK materials for dental application. Dent Mater. 2015;31(11):1377–84.PubMed
22.
Zurück zum Zitat Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, et al. Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater. 2013;101(7):1209–16.PubMed Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, et al. Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater. 2013;101(7):1209–16.PubMed
23.
Zurück zum Zitat Niem T, Youssef N, Wöstmann B. Energy dissipation capacities of CAD-CAM restorative materials: a comparative evaluation of resilience and toughness. J Prosthet Dent. 2019;121(1):101–9.PubMed Niem T, Youssef N, Wöstmann B. Energy dissipation capacities of CAD-CAM restorative materials: a comparative evaluation of resilience and toughness. J Prosthet Dent. 2019;121(1):101–9.PubMed
24.
Zurück zum Zitat Niem T, Youssef N, Wöstmann B. Influence of accelerated ageing on the physical properties of CAD/CAM restorative materials. Clin Oral Investig. 2020;24(7):2415–25. Niem T, Youssef N, Wöstmann B. Influence of accelerated ageing on the physical properties of CAD/CAM restorative materials. Clin Oral Investig. 2020;24(7):2415–25.
25.
Zurück zum Zitat Liebermann A, Wimmer T, Schmidlin PR, Scherer H, Löffler P, Roos M, et al. Physicomechanical characterization of polyetheretherketone and current esthetic dental CAD/CAM polymers after aging in different storage media. J Prosthet Dent. 2016;115(3):321–8.e2.PubMed Liebermann A, Wimmer T, Schmidlin PR, Scherer H, Löffler P, Roos M, et al. Physicomechanical characterization of polyetheretherketone and current esthetic dental CAD/CAM polymers after aging in different storage media. J Prosthet Dent. 2016;115(3):321–8.e2.PubMed
26.
Zurück zum Zitat Taufall S, Eichberger M, Schmidlin PR, Stawarczyk B. Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses. Clin Oral Investig. 2016;20(9):2493–500.PubMed Taufall S, Eichberger M, Schmidlin PR, Stawarczyk B. Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses. Clin Oral Investig. 2016;20(9):2493–500.PubMed
27.
Zurück zum Zitat Cekic-Nagas I, Egilmez F, Ergun G, Vallittu PK, Lassila LVJ. Load-bearing capacity of novel resin-based fixed dental prosthesis materials. Dent Mater J. 2018;37(1):49–58.PubMed Cekic-Nagas I, Egilmez F, Ergun G, Vallittu PK, Lassila LVJ. Load-bearing capacity of novel resin-based fixed dental prosthesis materials. Dent Mater J. 2018;37(1):49–58.PubMed
28.
Zurück zum Zitat Wimmer T, Huffmann AM, Eichberger M, Schmidlin PR, Stawarczyk B. Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: effect of specimen geometries, antagonist materials and test set-up configuration. Dent Mater. 2016;32(6):e127–36.PubMed Wimmer T, Huffmann AM, Eichberger M, Schmidlin PR, Stawarczyk B. Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: effect of specimen geometries, antagonist materials and test set-up configuration. Dent Mater. 2016;32(6):e127–36.PubMed
29.
Zurück zum Zitat Wachtel A, Zimmermann T, Sütel M, Adali U, Abou-Emara M, Müller WD, et al. Bacterial leakage and bending moments of screw-retained, composite-veneered PEEK implant crowns. J Mech Behav Biomed Mater. 2019;91:32–7.PubMed Wachtel A, Zimmermann T, Sütel M, Adali U, Abou-Emara M, Müller WD, et al. Bacterial leakage and bending moments of screw-retained, composite-veneered PEEK implant crowns. J Mech Behav Biomed Mater. 2019;91:32–7.PubMed
30.
Zurück zum Zitat Sirandoni D, Leal E, Weber B, Noritomi PY, Fuentes R, Borie E. Effect of different framework materials in implant-supported fixed mandibular prostheses: a finite element analysis. Int J Oral Maxillofac Implants. 2019;34(6):e107–14.PubMed Sirandoni D, Leal E, Weber B, Noritomi PY, Fuentes R, Borie E. Effect of different framework materials in implant-supported fixed mandibular prostheses: a finite element analysis. Int J Oral Maxillofac Implants. 2019;34(6):e107–14.PubMed
31.
Zurück zum Zitat Nazari V, Ghodsi S, Alikhasi M, Sahebi M, Shamshiri AR. Fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials. J Dent (Tehran). 2016;13(6):400–6. Nazari V, Ghodsi S, Alikhasi M, Sahebi M, Shamshiri AR. Fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials. J Dent (Tehran). 2016;13(6):400–6.
32.
Zurück zum Zitat Elsayed A, Farrag G, Chaar MS, Abdelnabi N, Kern M. Influence of different CAD/CAM crown materials on the fracture of custom-made titanium and zirconia implant abutments after artificial aging. Int J Prosthodont. 2019;32(1):91–6.PubMed Elsayed A, Farrag G, Chaar MS, Abdelnabi N, Kern M. Influence of different CAD/CAM crown materials on the fracture of custom-made titanium and zirconia implant abutments after artificial aging. Int J Prosthodont. 2019;32(1):91–6.PubMed
33.
Zurück zum Zitat Jin HY, Teng MH, Wang ZJ, Li X, Liang JY, Wang WX, et al. Comparative evaluation of BioHPP and titanium as a framework veneered with composite resin for implant-supported fixed dental prostheses. J Prosthet Dent. 2019;122(4):383–8.PubMed Jin HY, Teng MH, Wang ZJ, Li X, Liang JY, Wang WX, et al. Comparative evaluation of BioHPP and titanium as a framework veneered with composite resin for implant-supported fixed dental prostheses. J Prosthet Dent. 2019;122(4):383–8.PubMed
34.
Zurück zum Zitat Yilmaz B, Batak B, Seghi RR. Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Clin Implant Dent Relat Res. 2019;21(6):1132–9.PubMed Yilmaz B, Batak B, Seghi RR. Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Clin Implant Dent Relat Res. 2019;21(6):1132–9.PubMed
35.
Zurück zum Zitat Ghodsi S, Zeighami S, Meisami AM. Comparing retention and internal adaptation of different implant-supported, metal-free frameworks. Int J Prosthodont. 2018;31(5):475–7.PubMed Ghodsi S, Zeighami S, Meisami AM. Comparing retention and internal adaptation of different implant-supported, metal-free frameworks. Int J Prosthodont. 2018;31(5):475–7.PubMed
36.
Zurück zum Zitat Zeighami S, Ghodsi S, Sahebi M, Yazarloo S. Comparison of marginal adaptation of different implant-supported metal-free frameworks before and after cementation. Int J Prosthodont. 2019;32(4):361–3.PubMed Zeighami S, Ghodsi S, Sahebi M, Yazarloo S. Comparison of marginal adaptation of different implant-supported metal-free frameworks before and after cementation. Int J Prosthodont. 2019;32(4):361–3.PubMed
37.
Zurück zum Zitat Chen X, Mao B, Zhu Z, Yu J, Lu Y, Zhang Q, et al. A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK. Sci Rep. 2019;9(1):13975.PubMedPubMedCentral Chen X, Mao B, Zhu Z, Yu J, Lu Y, Zhang Q, et al. A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK. Sci Rep. 2019;9(1):13975.PubMedPubMedCentral
38.
Zurück zum Zitat Tribst JPM, Dal Piva AMO, Borges ALS, Araújo RM, da Silva JMF, Bottino MA, et al. Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures. Dent Mater. 2020;36(2):179–86.PubMed Tribst JPM, Dal Piva AMO, Borges ALS, Araújo RM, da Silva JMF, Bottino MA, et al. Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures. Dent Mater. 2020;36(2):179–86.PubMed
39.
Zurück zum Zitat Peng TY, Ogawa Y, Akebono H, Iwaguro S, Sugeta A, Shimoe S. Finite-element analysis and optimization of the mechanical properties of polyetheretherketone (PEEK) clasps for removable partial dentures. J Prosthodont Res. 2020;64(3):250–6. Peng TY, Ogawa Y, Akebono H, Iwaguro S, Sugeta A, Shimoe S. Finite-element analysis and optimization of the mechanical properties of polyetheretherketone (PEEK) clasps for removable partial dentures. J Prosthodont Res. 2020;64(3):250–6.
40.
Zurück zum Zitat Muhsin SA, Wood DJ, Johnson A, et al. Effects of novel polyetheretherketone (PEEK) clasp design on retentive force at different tooth undercuts. J Oral Dent Res. 2018;5:13–25. Muhsin SA, Wood DJ, Johnson A, et al. Effects of novel polyetheretherketone (PEEK) clasp design on retentive force at different tooth undercuts. J Oral Dent Res. 2018;5:13–25.
41.
Zurück zum Zitat Negm EE, Aboutaleb FA, Alam-Eldein AM. Virtual evaluation of the accuracy of fit and trueness in maxillary poly (etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques. J Prosthodont. 2019;28(7):804–10.PubMed Negm EE, Aboutaleb FA, Alam-Eldein AM. Virtual evaluation of the accuracy of fit and trueness in maxillary poly (etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques. J Prosthodont. 2019;28(7):804–10.PubMed
42.
Zurück zum Zitat Arnold C, Hey J, Schweyen R, Setz JM. Accuracy of CAD-CAM-fabricated removable partial dentures. J Prosthet Dent. 2018;119(4):586–92.PubMed Arnold C, Hey J, Schweyen R, Setz JM. Accuracy of CAD-CAM-fabricated removable partial dentures. J Prosthet Dent. 2018;119(4):586–92.PubMed
43.
Zurück zum Zitat Hada T, Suzuki T, Minakuchi S, Takahashi H. Reduction in maxillary complete denture deformation using framework material made by computer-aided design and manufacturing systems. J Mech Behav Biomed Mater. 2020;103:103514.PubMed Hada T, Suzuki T, Minakuchi S, Takahashi H. Reduction in maxillary complete denture deformation using framework material made by computer-aided design and manufacturing systems. J Mech Behav Biomed Mater. 2020;103:103514.PubMed
44.
Zurück zum Zitat Schubert O, Reitmaier J, Schweiger J, Erdelt K, Güth JF. Retentive force of PEEK secondary crowns on zirconia primary crowns over time. Clin Oral Investig. 2019;23(5):2331–8.PubMed Schubert O, Reitmaier J, Schweiger J, Erdelt K, Güth JF. Retentive force of PEEK secondary crowns on zirconia primary crowns over time. Clin Oral Investig. 2019;23(5):2331–8.PubMed
45.
Zurück zum Zitat Merk S, Wagner C, Stock V, Eichberger M, Schmidlin PR, Roos M, et al. Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: the influence of fabrication method and taper. Materials (Basel). 2016;9(11):908. Merk S, Wagner C, Stock V, Eichberger M, Schmidlin PR, Roos M, et al. Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: the influence of fabrication method and taper. Materials (Basel). 2016;9(11):908.
46.
Zurück zum Zitat Stock V, Wagner C, Merk S, Roos M, Schmidlin PR, Eichberger M, et al. Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dent Mater J. 2016;35(4):594–600.PubMed Stock V, Wagner C, Merk S, Roos M, Schmidlin PR, Eichberger M, et al. Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dent Mater J. 2016;35(4):594–600.PubMed
47.
Zurück zum Zitat Wagner C, Stock V, Merk S, Schmidlin PR, Roos M, Eichberger M, et al. Retention load of telescopic crowns with different taper angles between cobalt-chromium and Polyetheretherketone made with three different manufacturing processes examined by pull-off test. J Prosthodont. 2018;27(2):162–8.PubMed Wagner C, Stock V, Merk S, Schmidlin PR, Roos M, Eichberger M, et al. Retention load of telescopic crowns with different taper angles between cobalt-chromium and Polyetheretherketone made with three different manufacturing processes examined by pull-off test. J Prosthodont. 2018;27(2):162–8.PubMed
48.
Zurück zum Zitat Stock V, Schmidlin PR, Merk S, Wagner C, Roos M, Eichberger M, et al. PEEK primary crowns with cobalt-chromium, zirconia and galvanic secondary crowns with different tapers-a comparison of retention forces. Materials (Basel). 2016;9(3):187. Stock V, Schmidlin PR, Merk S, Wagner C, Roos M, Eichberger M, et al. PEEK primary crowns with cobalt-chromium, zirconia and galvanic secondary crowns with different tapers-a comparison of retention forces. Materials (Basel). 2016;9(3):187.
50.
Zurück zum Zitat Abdullah AO, Tsitrou EA, Pollington S. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns. J Appl Oral Sci. 2016;24(3):258–63.PubMedPubMedCentral Abdullah AO, Tsitrou EA, Pollington S. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns. J Appl Oral Sci. 2016;24(3):258–63.PubMedPubMedCentral
51.
Zurück zum Zitat Parmigiani-Izquierdo JM, Cabaña-Muñoz ME, Merino JJ, Sánchez-Pérez A. Zirconia implants and peek restorations for the replacement of upper molars. Int J Implant Dent. 2017;3(1):5.PubMedPubMedCentral Parmigiani-Izquierdo JM, Cabaña-Muñoz ME, Merino JJ, Sánchez-Pérez A. Zirconia implants and peek restorations for the replacement of upper molars. Int J Implant Dent. 2017;3(1):5.PubMedPubMedCentral
52.
Zurück zum Zitat Cabello-Domínguez G, Pérez-López J, Veiga-López B, González D, Revilla-León M. Maxillary zirconia and mandibular composite resin-lithium disilicate-modified PEEK fixed implant-supported restorations for a completely edentulous patient with an atrophic maxilla and mandible: a clinical report. J Prosthet Dent. 2019;S0022-3913(19)30663–8. Cabello-Domínguez G, Pérez-López J, Veiga-López B, González D, Revilla-León M. Maxillary zirconia and mandibular composite resin-lithium disilicate-modified PEEK fixed implant-supported restorations for a completely edentulous patient with an atrophic maxilla and mandible: a clinical report. J Prosthet Dent. 2019;S0022-3913(19)30663–8.
53.
Zurück zum Zitat Harb IE, Abdel-Khalek EA, Hegazy SA. CAD/CAM constructed poly (etheretherketone) (PEEK) framework of Kennedy class I removable partial denture: a clinical report. J Prosthodont. 2019;28(2):e595–8.PubMed Harb IE, Abdel-Khalek EA, Hegazy SA. CAD/CAM constructed poly (etheretherketone) (PEEK) framework of Kennedy class I removable partial denture: a clinical report. J Prosthodont. 2019;28(2):e595–8.PubMed
54.
Zurück zum Zitat Costa-Palau S, Torrents-Nicolas J, Brufau-de Barberà M, Cabratosa-Termes J. Use of polyetheretherketone in the fabrication of a maxillary obturator prosthesis: a clinical report. J Prosthet Dent. 2014;112(3):680–2.PubMed Costa-Palau S, Torrents-Nicolas J, Brufau-de Barberà M, Cabratosa-Termes J. Use of polyetheretherketone in the fabrication of a maxillary obturator prosthesis: a clinical report. J Prosthet Dent. 2014;112(3):680–2.PubMed
55.
Zurück zum Zitat Mangano F, Mangano C, Margiani B, Admakin O. Combining intraoral and face scans for the design and fabrication of computer-assisted design/computer-assisted manufacturing (CAD/CAM) polyether-ether-ketone (PEEK) implant-supported bars for maxillary overdentures. Scanning. 2019;2019:4274715.PubMedPubMedCentral Mangano F, Mangano C, Margiani B, Admakin O. Combining intraoral and face scans for the design and fabrication of computer-assisted design/computer-assisted manufacturing (CAD/CAM) polyether-ether-ketone (PEEK) implant-supported bars for maxillary overdentures. Scanning. 2019;2019:4274715.PubMedPubMedCentral
56.
Zurück zum Zitat Spies BC, Petsch M, Kohal RJ, Beuer F. Digital production of a zirconia, implant-supported removable prosthesis with an individual Bar attachment milled from polyether ether ketone: a case history report. Int J Prosthodont. 2018;31(5):471–4.PubMed Spies BC, Petsch M, Kohal RJ, Beuer F. Digital production of a zirconia, implant-supported removable prosthesis with an individual Bar attachment milled from polyether ether ketone: a case history report. Int J Prosthodont. 2018;31(5):471–4.PubMed
57.
Zurück zum Zitat Hahnel S, Scherl C, Rosentritt M. Interim rehabilitation of occlusal vertical dimension using a double-crown-retained removable dental prosthesis with polyetheretherketone framework. J Prosthet Dent. 2018;119(3):315–8.PubMed Hahnel S, Scherl C, Rosentritt M. Interim rehabilitation of occlusal vertical dimension using a double-crown-retained removable dental prosthesis with polyetheretherketone framework. J Prosthet Dent. 2018;119(3):315–8.PubMed
58.
Zurück zum Zitat Siewert B. Metal-free implant-supported restorations in the edentulous jaw. EDI J. 2018;3:68–74. Siewert B. Metal-free implant-supported restorations in the edentulous jaw. EDI J. 2018;3:68–74.
59.
Zurück zum Zitat Waltimo A, Kononen M. A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res. 1993;101(3):171–5.PubMed Waltimo A, Kononen M. A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res. 1993;101(3):171–5.PubMed
60.
Zurück zum Zitat Beuer F, Steff B, Naumann M, Sorensen JA. Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials. Eur J Oral Sci. 2008;116:381–6.PubMed Beuer F, Steff B, Naumann M, Sorensen JA. Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials. Eur J Oral Sci. 2008;116:381–6.PubMed
61.
Zurück zum Zitat Kolbeck C, Behr M, Rosentritt M, Handel G. Fracture force of tooth–tooth-and implant–tooth-supported all-ceramic fixed partial dentures using titanium vs. customized zirconia implant abutments. Clin Oral Implants Res. 2008;19:1049–53.PubMed Kolbeck C, Behr M, Rosentritt M, Handel G. Fracture force of tooth–tooth-and implant–tooth-supported all-ceramic fixed partial dentures using titanium vs. customized zirconia implant abutments. Clin Oral Implants Res. 2008;19:1049–53.PubMed
62.
Zurück zum Zitat Dal Piva AMO, Tribst JPM, Borges ALS, Souza ROAE, Bottino MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater. 2018;34(9):1342–50.PubMed Dal Piva AMO, Tribst JPM, Borges ALS, Souza ROAE, Bottino MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater. 2018;34(9):1342–50.PubMed
63.
Zurück zum Zitat Caglar I, Ates SM, Yesil Duymus Z. An in vitro evaluation of the effect of various adhesives and surface treatments on bond strength of resin cement to Polyetheretherketone. J Prosthodont. 2019;28(1):e342–9.PubMed Caglar I, Ates SM, Yesil Duymus Z. An in vitro evaluation of the effect of various adhesives and surface treatments on bond strength of resin cement to Polyetheretherketone. J Prosthodont. 2019;28(1):e342–9.PubMed
64.
Zurück zum Zitat Keul C, Liebermann A, Schmidlin PR, Roos M, Sener B, Stawarczyk B. Influence of PEEK surface modification on surface properties and bond strength to veneering resin composites. J Adhes Dent. 2014;16(4):383–92.PubMed Keul C, Liebermann A, Schmidlin PR, Roos M, Sener B, Stawarczyk B. Influence of PEEK surface modification on surface properties and bond strength to veneering resin composites. J Adhes Dent. 2014;16(4):383–92.PubMed
65.
Zurück zum Zitat Uhrenbacher J, Schmidlin PR, Keul C, Eichberger M, Roos M, Gernet W, et al. The effect of surface modification on the retention strength of polyetheretherketone crowns adhesively bonded to dentin abutments. J Prosthet Dent. 2014;112(6):1489–97.PubMed Uhrenbacher J, Schmidlin PR, Keul C, Eichberger M, Roos M, Gernet W, et al. The effect of surface modification on the retention strength of polyetheretherketone crowns adhesively bonded to dentin abutments. J Prosthet Dent. 2014;112(6):1489–97.PubMed
66.
Zurück zum Zitat Zhou L, Qian Y, Zhu Y, Liu H, Gan K, Guo J. The effect of different surface treatments on the bond strength of PEEK composite materials. Dent Mater. 2014;30(8):e209–15.PubMed Zhou L, Qian Y, Zhu Y, Liu H, Gan K, Guo J. The effect of different surface treatments on the bond strength of PEEK composite materials. Dent Mater. 2014;30(8):e209–15.PubMed
67.
Zurück zum Zitat Stawarczyk B, Taufall S, Roos M, Schmidlin PR, Lümkemann N. Bonding of composite resins to PEEK: the influence of adhesive systems and air-abrasion parameters. Clin Oral Investig. 2018;22(2):763–71.PubMed Stawarczyk B, Taufall S, Roos M, Schmidlin PR, Lümkemann N. Bonding of composite resins to PEEK: the influence of adhesive systems and air-abrasion parameters. Clin Oral Investig. 2018;22(2):763–71.PubMed
68.
Zurück zum Zitat Stawarczyk B, Bähr N, Beuer F, Wimmer T, Eichberger M, Gernet W, et al. Influence of plasma pretreatment on shear bond strength of self-adhesive resin cements to polyetheretherketone. Clin Oral Investig. 2014;18(1):163–70.PubMed Stawarczyk B, Bähr N, Beuer F, Wimmer T, Eichberger M, Gernet W, et al. Influence of plasma pretreatment on shear bond strength of self-adhesive resin cements to polyetheretherketone. Clin Oral Investig. 2014;18(1):163–70.PubMed
69.
Zurück zum Zitat Stawarczyk B, Jordan P, Schmidlin PR, Roos M, Eichberger M, Gernet W, et al. PEEK surface treatment effects on tensile bond strength to veneering resins. J Prosthet Dent. 2014;112(5):1278–88.PubMed Stawarczyk B, Jordan P, Schmidlin PR, Roos M, Eichberger M, Gernet W, et al. PEEK surface treatment effects on tensile bond strength to veneering resins. J Prosthet Dent. 2014;112(5):1278–88.PubMed
70.
Zurück zum Zitat Stawarczyk B, Thrun H, Eichberger M, Roos M, Edelhoff D, Schweiger J, et al. Effect of different surface pretreatments and adhesives on the load-bearing capacity of veneered 3-unit PEEK FDPs. J Prosthet Dent. 2015;114(5):666–73.PubMed Stawarczyk B, Thrun H, Eichberger M, Roos M, Edelhoff D, Schweiger J, et al. Effect of different surface pretreatments and adhesives on the load-bearing capacity of veneered 3-unit PEEK FDPs. J Prosthet Dent. 2015;114(5):666–73.PubMed
71.
Zurück zum Zitat Stawarczyk B, Keul C, Beuer F, Roos M, Schmidlin PR. Tensile bond strength of veneering resins to PEEK: impact of different adhesives. Dent Mater J. 2013;32(3):441–8.PubMed Stawarczyk B, Keul C, Beuer F, Roos M, Schmidlin PR. Tensile bond strength of veneering resins to PEEK: impact of different adhesives. Dent Mater J. 2013;32(3):441–8.PubMed
72.
Zurück zum Zitat Stawarczyk B, Schmid P, Roos M, Eichberger M, Schmidlin PR. Spectrophotometric evaluation of Polyetheretherketone (PEEK) as a Core material and a comparison with gold standard Core materials. Materials (Basel). 2016;9(6):491. Stawarczyk B, Schmid P, Roos M, Eichberger M, Schmidlin PR. Spectrophotometric evaluation of Polyetheretherketone (PEEK) as a Core material and a comparison with gold standard Core materials. Materials (Basel). 2016;9(6):491.
73.
Zurück zum Zitat Mühlemann S, Truninger TC, Stawarczyk B, Hämmerle CH, Sailer I. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging. Clin Oral Implants Res. 2014;25(1):74–81.PubMed Mühlemann S, Truninger TC, Stawarczyk B, Hämmerle CH, Sailer I. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging. Clin Oral Implants Res. 2014;25(1):74–81.PubMed
74.
Zurück zum Zitat Sailer I, Asgeirsson AG, Thoma DS, Fehmer V, Aspelund T, Özcan M, et al. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: a study on the titanium resin base concept. Clin Oral Implants Res. 2018;29(4):411–23.PubMed Sailer I, Asgeirsson AG, Thoma DS, Fehmer V, Aspelund T, Özcan M, et al. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: a study on the titanium resin base concept. Clin Oral Implants Res. 2018;29(4):411–23.PubMed
75.
Zurück zum Zitat Tannous F, Steiner M, Shahin R, Kern M. Retentive forces and fatigue resistance of thermoplastic resin clasps. Dent Mater. 2012;28(3):273–8.PubMed Tannous F, Steiner M, Shahin R, Kern M. Retentive forces and fatigue resistance of thermoplastic resin clasps. Dent Mater. 2012;28(3):273–8.PubMed
76.
Zurück zum Zitat Reddy BM, Himabindu M, Padmaja BI, Sunil M, Reddy NR. Palatal vault depth influence on the flexural strength of two heat cure acrylic denture base resins: an in vitro study. J Contemp Dent Pract. 2013;14(6):1131–6.PubMed Reddy BM, Himabindu M, Padmaja BI, Sunil M, Reddy NR. Palatal vault depth influence on the flexural strength of two heat cure acrylic denture base resins: an in vitro study. J Contemp Dent Pract. 2013;14(6):1131–6.PubMed
77.
Zurück zum Zitat Hamanaka I, Iwamoto M, Lassila L, Vallittu P, Shimizu H, Takahashi Y. Influence of water sorption on mechanical properties of injection-molded thermoplastic denture base resins. Acta Odontol Scand. 2014;72(8):859–65.PubMed Hamanaka I, Iwamoto M, Lassila L, Vallittu P, Shimizu H, Takahashi Y. Influence of water sorption on mechanical properties of injection-molded thermoplastic denture base resins. Acta Odontol Scand. 2014;72(8):859–65.PubMed
78.
Zurück zum Zitat Muhsin SA, Hatton PV, Johnson A, Sereno N, Wood DJ. Determination of Polyetheretherketone (PEEK) mechanical properties as a denture material. Saudi Dent J. 2019;31(3):382–91.PubMedPubMedCentral Muhsin SA, Hatton PV, Johnson A, Sereno N, Wood DJ. Determination of Polyetheretherketone (PEEK) mechanical properties as a denture material. Saudi Dent J. 2019;31(3):382–91.PubMedPubMedCentral
79.
Zurück zum Zitat Heimer S, Schmidlin PR, Roos M, Stawarczyk B. Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols. J Prosthet Dent. 2017;117(3):419–25.PubMed Heimer S, Schmidlin PR, Roos M, Stawarczyk B. Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols. J Prosthet Dent. 2017;117(3):419–25.PubMed
80.
Zurück zum Zitat Heimer S, Schmidlin PR, Stawarczyk B. Discoloration of PMMA, composite, and PEEK. Clin Oral Investig. 2017;21(4):1191–200.PubMed Heimer S, Schmidlin PR, Stawarczyk B. Discoloration of PMMA, composite, and PEEK. Clin Oral Investig. 2017;21(4):1191–200.PubMed
Metadaten
Titel
The use of PEEK in digital prosthodontics: A narrative review
verfasst von
Ioannis Papathanasiou
Phophi Kamposiora
George Papavasiliou
Marco Ferrari
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
BMC Oral Health / Ausgabe 1/2020
Elektronische ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-020-01202-7

Weitere Artikel der Ausgabe 1/2020

BMC Oral Health 1/2020 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.