Skip to main content
Erschienen in: International Orthopaedics 8/2018

17.02.2018 | Original Paper

Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup

verfasst von: Jing-Xin Zhao, Xiu-Yun Su, Zhe Zhao, Ruo-Xiu Xiao, Li-Cheng Zhang, Pei-Fu Tang

Erschienen in: International Orthopaedics | Ausgabe 8/2018

Einloggen, um Zugang zu erhalten

Abstract

Aim

The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model.

Methods

A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed.

Results

When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously.

Discussion

This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Grammatopoulos G, Alvand A, Monk AP, Mellon S, Pandit H, Rees J, Gill HS, Murray DW (2016) Surgeons' accuracy in achieving their desired acetabular component orientation. J Bone Joint Surg Am 98(17):e72CrossRefPubMed Grammatopoulos G, Alvand A, Monk AP, Mellon S, Pandit H, Rees J, Gill HS, Murray DW (2016) Surgeons' accuracy in achieving their desired acetabular component orientation. J Bone Joint Surg Am 98(17):e72CrossRefPubMed
2.
Zurück zum Zitat Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg (Br) 75(2):228–232CrossRef Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg (Br) 75(2):228–232CrossRef
3.
Zurück zum Zitat Pradhan R (1999) Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg (Br) 81(3):431–435CrossRef Pradhan R (1999) Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg (Br) 81(3):431–435CrossRef
4.
Zurück zum Zitat Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplast 19(3):387–390CrossRef Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplast 19(3):387–390CrossRef
5.
Zurück zum Zitat Liaw CK, Yang RS, Hou SM, Wu TY, Fuh CS (2009) Measurement of the acetabular cup anteversion on simulated radiographs. J Arthroplast 24(3):468–474CrossRef Liaw CK, Yang RS, Hou SM, Wu TY, Fuh CS (2009) Measurement of the acetabular cup anteversion on simulated radiographs. J Arthroplast 24(3):468–474CrossRef
6.
Zurück zum Zitat Derbyshire B (2008) Correction of acetabular cup orientation measurements for X-ray beam offset. Med Eng Phys 30(9):1119–1126CrossRefPubMed Derbyshire B (2008) Correction of acetabular cup orientation measurements for X-ray beam offset. Med Eng Phys 30(9):1119–1126CrossRefPubMed
7.
Zurück zum Zitat Amiri S, Masri BA, Garbuz D, Anglin C, Wilson DR (2012) A multiplanar radiography method for assessing cup orientation in total hip arthroplasty. J Biomech Eng 134(10):101008CrossRefPubMed Amiri S, Masri BA, Garbuz D, Anglin C, Wilson DR (2012) A multiplanar radiography method for assessing cup orientation in total hip arthroplasty. J Biomech Eng 134(10):101008CrossRefPubMed
8.
Zurück zum Zitat Stuart Kerrigan C, McKenna SJ, Ricketts IW, Wigderowitz C (2008) Automated assessment of polyethylene wear in cemented acetabular components using anteroposterior radiographs of total hip replacements. Comput Med Imaging Graph 32(3):221–238CrossRefPubMed Stuart Kerrigan C, McKenna SJ, Ricketts IW, Wigderowitz C (2008) Automated assessment of polyethylene wear in cemented acetabular components using anteroposterior radiographs of total hip replacements. Comput Med Imaging Graph 32(3):221–238CrossRefPubMed
9.
Zurück zum Zitat Ackland MK, Bourne WB, Uhthoff HK (1986) Anteversion of the acetabular cup. Measurement of angle after total hip replacement. J Bone Joint Surg (Br) 68(3):409–413CrossRef Ackland MK, Bourne WB, Uhthoff HK (1986) Anteversion of the acetabular cup. Measurement of angle after total hip replacement. J Bone Joint Surg (Br) 68(3):409–413CrossRef
10.
Zurück zum Zitat Malik A, Wan Z, Jaramaz B, Bowman G, Dorr LD (2010) A validation model for measurement of acetabular component position. J Arthroplast 25(5):812–819CrossRef Malik A, Wan Z, Jaramaz B, Bowman G, Dorr LD (2010) A validation model for measurement of acetabular component position. J Arthroplast 25(5):812–819CrossRef
11.
Zurück zum Zitat Wan Z, Malik A, Jaramaz B, Chao L, Dorr LD (2009) Imaging and navigation measurement of acetabular component position in THA. Clin Orthop Relat Res 467(1):32–42CrossRefPubMed Wan Z, Malik A, Jaramaz B, Chao L, Dorr LD (2009) Imaging and navigation measurement of acetabular component position in THA. Clin Orthop Relat Res 467(1):32–42CrossRefPubMed
12.
Zurück zum Zitat Wang L, Thoreson AR, Trousdale RT, Morrey BF, Dai K, An KN (2017) Radiographic cup anteversion measurement corrected from pelvic tilt. Med Eng Phys 49:103–108CrossRefPubMed Wang L, Thoreson AR, Trousdale RT, Morrey BF, Dai K, An KN (2017) Radiographic cup anteversion measurement corrected from pelvic tilt. Med Eng Phys 49:103–108CrossRefPubMed
13.
Zurück zum Zitat Blendea S, Eckman K, Jaramaz B, Levison TJ, Digioia AM 3rd (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10(1):37–43CrossRefPubMed Blendea S, Eckman K, Jaramaz B, Levison TJ, Digioia AM 3rd (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10(1):37–43CrossRefPubMed
14.
Zurück zum Zitat Mellano CR, Spitzer AI (2015) How does pelvic rotation or tilt affect radiographic measurement of acetabular component inclination angle during THA? J Orthop 12(4):222–227CrossRef Mellano CR, Spitzer AI (2015) How does pelvic rotation or tilt affect radiographic measurement of acetabular component inclination angle during THA? J Orthop 12(4):222–227CrossRef
15.
Zurück zum Zitat Schwarz TJ, Weber M, Dornia C, Worlicek M, Renkawitz T, Grifka J, Craiovan B (2017) Correction of pelvic tilt and pelvic rotation in cup measurement after THA—an experimental study. Rofo 189(9):864–873CrossRefPubMed Schwarz TJ, Weber M, Dornia C, Worlicek M, Renkawitz T, Grifka J, Craiovan B (2017) Correction of pelvic tilt and pelvic rotation in cup measurement after THA—an experimental study. Rofo 189(9):864–873CrossRefPubMed
16.
Zurück zum Zitat Zhao JX, Su XY, Xiao RX, Zhao Z, Zhang LH, Zhang LC, Tang PF (2016) A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty. Med Eng Phys 38(11):1376–1381CrossRefPubMed Zhao JX, Su XY, Xiao RX, Zhao Z, Zhang LH, Zhang LC, Tang PF (2016) A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty. Med Eng Phys 38(11):1376–1381CrossRefPubMed
17.
Zurück zum Zitat Goergen TG, Resnick D (1975) Evaluation of acetabular anteversion following total hip arthroplasty: necessity of proper centring. Br J Radiol 48(568):259–260CrossRefPubMed Goergen TG, Resnick D (1975) Evaluation of acetabular anteversion following total hip arthroplasty: necessity of proper centring. Br J Radiol 48(568):259–260CrossRefPubMed
18.
Zurück zum Zitat Schwarz T, Weber M, Worner M, Renkawitz T, Grifka J, Craiovan B (2017) Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study. Int J Comput Assist Radiol Surg 12(5):829–837CrossRefPubMed Schwarz T, Weber M, Worner M, Renkawitz T, Grifka J, Craiovan B (2017) Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study. Int J Comput Assist Radiol Surg 12(5):829–837CrossRefPubMed
19.
Zurück zum Zitat Westacott DJ, McArthur J, King RJ, Foguet P (2013) Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography. J Orthop Surg Res 8:8CrossRefPubMedPubMedCentral Westacott DJ, McArthur J, King RJ, Foguet P (2013) Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography. J Orthop Surg Res 8:8CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J (2006) Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58(2):294–300CrossRefPubMed Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J (2006) Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58(2):294–300CrossRefPubMed
21.
Zurück zum Zitat Amirouche F, Solitro GF, Chandrasekaran S, Domb BG, Gonzalez MH (2016) Validating a modified circle theorem method for the measurement of acetabular cup anteversion on plain radiography with intra-operative data from robotic assisted total hip arthroplasty. J Arthroplast 31(1):323–329CrossRef Amirouche F, Solitro GF, Chandrasekaran S, Domb BG, Gonzalez MH (2016) Validating a modified circle theorem method for the measurement of acetabular cup anteversion on plain radiography with intra-operative data from robotic assisted total hip arthroplasty. J Arthroplast 31(1):323–329CrossRef
Metadaten
Titel
Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup
verfasst von
Jing-Xin Zhao
Xiu-Yun Su
Zhe Zhao
Ruo-Xiu Xiao
Li-Cheng Zhang
Pei-Fu Tang
Publikationsdatum
17.02.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 8/2018
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-3809-y

Weitere Artikel der Ausgabe 8/2018

International Orthopaedics 8/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.