Purpose

Although a C2 pedicle screw and a C1–2 transarticular screw are the most rigid anchors, these screws cannot be used in cases with bilateral high-riding vertebral arteries. The authors describe their recent experience using a novel method of C2–3 transuncovertebral joint screw placement for occipitocervical fixation.

Methods

A 67-year-old patient suffered myelopathy due to instability at C1–2. The patient had bilateral high-riding vertebral arteries that precluded the use of a C2 pedicle screw or a C1–2 transarticular screw.

Results

A C2–3 transuncovertebral joint screw was applied bilaterally under 3D navigation guidance. The patient’s postoperative course was uneventful, and his neurological status improved after the surgery. Bony fusion was achieved after the surgery.

Conclusions

This is the first report to describe the technique of transuncovertebral joint screw. Using a C2–3 transuncovertebral joint screw, a long screw could be used, and it provided an anchor at C3 and C2 from a posterior approach.
Literatur
1.
Zurück zum Zitat Du JY, Aichmair A, Kueper J, Wright T, Lebl DR (2015) Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systemic review and meta-analysis. J Neurosurg Spine 22:151–161CrossRefPubMed Du JY, Aichmair A, Kueper J, Wright T, Lebl DR (2015) Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systemic review and meta-analysis. J Neurosurg Spine 22:151–161CrossRefPubMed
2.
Zurück zum Zitat Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162CrossRefPubMed Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162CrossRefPubMed
3.
Zurück zum Zitat Daentzer D (2009) Operative management for atlantoaxial instability in case of bilateral high riding vertebral artery. Arch Orthop Trauma Surg 129:177–182CrossRefPubMed Daentzer D (2009) Operative management for atlantoaxial instability in case of bilateral high riding vertebral artery. Arch Orthop Trauma Surg 129:177–182CrossRefPubMed
4.
Zurück zum Zitat Hong JT, Takigawa T, Udayakunmar R, Shin HK, Simon P, Orías AAE et al (2011) Biomechanical effect of the C2 laminar decortication on the stability of C2 intralaminar screw construct and biomechanical comparison of C2 intralaminar screw and C2 pars screw. Neurosurgery 69:ons1–ons6CrossRefPubMed Hong JT, Takigawa T, Udayakunmar R, Shin HK, Simon P, Orías AAE et al (2011) Biomechanical effect of the C2 laminar decortication on the stability of C2 intralaminar screw construct and biomechanical comparison of C2 intralaminar screw and C2 pars screw. Neurosurgery 69:ons1–ons6CrossRefPubMed
5.
Zurück zum Zitat Izeki M, Neo M, Ito H, Nagai K, Ishizaki T, Okamoto T et al (2013) Reduction of atlantoaxial subluxation causes airway stenosis. Spine (Phila Pa) 38:E513–E520CrossRef Izeki M, Neo M, Ito H, Nagai K, Ishizaki T, Okamoto T et al (2013) Reduction of atlantoaxial subluxation causes airway stenosis. Spine (Phila Pa) 38:E513–E520CrossRef
6.
Zurück zum Zitat Izeki M, Neo M, Takemoto M, Fujibayashi S, Ito H, Nagai K, Matsuda S (2014) The O-C2 angle established at occipito-cervical fusion dictates the patient’s density in terms of postoperative dyspnea and/or dysphagia. Eur Spine J 23:328–336CrossRefPubMedPubMedCentral Izeki M, Neo M, Takemoto M, Fujibayashi S, Ito H, Nagai K, Matsuda S (2014) The O-C2 angle established at occipito-cervical fusion dictates the patient’s density in terms of postoperative dyspnea and/or dysphagia. Eur Spine J 23:328–336CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat White AA, Panjabi MM (1978) Kinematics of the spine. In: White AA, Panjabi MM (eds) Clinical biomechanics of the spine. JB Lippincott, Philadelphia, pp 61–90 White AA, Panjabi MM (1978) Kinematics of the spine. In: White AA, Panjabi MM (eds) Clinical biomechanics of the spine. JB Lippincott, Philadelphia, pp 61–90
8.
Zurück zum Zitat Panjabi MM, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions. Spine (Phila Pa) 16:861–869CrossRef Panjabi MM, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions. Spine (Phila Pa) 16:861–869CrossRef
9.
Zurück zum Zitat Abumi K, Ito M, Sudo H (2012) Reconstruction of the subaxial cervical spine using pedicle screw instrumentation. Spine (Phila Pa) 37:E349–E356CrossRef Abumi K, Ito M, Sudo H (2012) Reconstruction of the subaxial cervical spine using pedicle screw instrumentation. Spine (Phila Pa) 37:E349–E356CrossRef
10.
Zurück zum Zitat Pal GP, Routal RV, Saggu SK (2001) The orientation of the articular facets of the zygapophyseal joints at the cervical and upper thoracic region. J Anat 198:431–441CrossRefPubMedPubMedCentral Pal GP, Routal RV, Saggu SK (2001) The orientation of the articular facets of the zygapophyseal joints at the cervical and upper thoracic region. J Anat 198:431–441CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Mason A, Paulsen R, Babuska JM, Rajpal S, Burneikiene S, Nelson EL et al (2014) The accuracy of pedicle screw placement using intraoperative image guidance systems. A systemic review. J Neurosurgery Spine 20:196–203CrossRef Mason A, Paulsen R, Babuska JM, Rajpal S, Burneikiene S, Nelson EL et al (2014) The accuracy of pedicle screw placement using intraoperative image guidance systems. A systemic review. J Neurosurgery Spine 20:196–203CrossRef
Metadaten
Titel
Transuncovertebral joint screw placement: technical note
verfasst von
Tomoyuki Takigawa
Masato Tanaka
Takuya Morita
Yoshihisa Sugimoto
Ozaki Toshifumi
Publikationsdatum
30.11.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 6/2016
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-4343-x

Weitere Artikel der Ausgabe 6/2016

European Spine Journal 6/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.