Skip to main content
Erschienen in: BMC Musculoskeletal Disorders 1/2020

Open Access 01.12.2020 | Case report

Utility of CT-based navigation in revision total hip arthroplasty for a patient with severe posterior pelvic tilt-case report-

verfasst von: Shintaro Watanabe, Hyonmin Choe, Naomi Kobayashi, Hiroyuki Ike, Daigo Kobayashi, Syota Higashihira, Yutaka Inaba

Erschienen in: BMC Musculoskeletal Disorders | Ausgabe 1/2020

Abstract

Background

Hip dislocation after total hip arthroplasty (THA) or hemi-arthroplasty is a rare but serious complication. Dislocation may be prevented by appropriate positioning of the cup angle of inclination and anteversion.

Case presentation

This report describes a 66-year-old woman who underwent revision THA using a computer tomography (CT)-based navigation system to treat an anterior dislocation after hemi-arthroplasty due to a severe posterior pelvic tilt. At initial presentation, her sagittal pelvic tilt angle, measured as anterior pelvic plane (APP) in the supine position, was 38 degrees posterior to the coronal plane. Owing to the posterior pelvic tilt, revision THA was performed using CT-based navigation, while dual mobility was utilized to reduce the risk of re-dislocation. Postoperatively, her sagittal pelvic tilt angle showed further progression over time, with an APP of 66 degrees posterior to the coronal plane in the standing position 3 years after revision THA. Simulation with the Zed Hip system showed that the risk of implant-to-implant impingement was much higher posteriorly than anteriorly. Gait analysis demonstrated hyperextension of the hip joint while walking, although hip joint function required for daily activity was maintained.

Conclusions

Preoperative planning of implant orientation, based on posterior progression of pelvic tilt and accurate placement of components, is important to prevent dislocation in patients with severe posterior pelvic tilt. A dual mobility cup may also improve hip function in these patients.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
THA
Total hip arthroplasty
CT
Computer tomography
ROM
Range of motion
APP
Anterior pelvic plane
FPP
Functional pelvic plane
HHS
Harris Hip score.

Background

Changes in sagittal pelvic tilt affect the functional angle of implant position after total hip arthroplasty (THA). Appropriate positioning of the acetabular component can reduce the risk of hip dislocation after THA. Consideration of changes in functional cup inclination and anteversion due to sagittal pelvic tilt is critical in obtaining good clinical outcomes [1].
This report describes a patient who underwent revision THA using a computer tomography (CT)-based navigation system to treat an anterior dislocation after hemi-arthroplasty caused by a severe posterior pelvic tilt. Use of a CT-based navigation system enabled accurate cup placement in the presence of a severe posterior pelvic tilt. Daily activities of the patient were preserved despite a progressive posterior change in pelvic tilt after revision THA.

Case presentation

A 66-year-old woman presented at our hospital for the treatment of a dislocation 15 years after hemi-arthroplasty. She had undergone hemi-arthroplasty at another hospital using a porous coated anatomical stem (Stryker, MI) for a femoral neck fracture. The patient had poor posture due to compression fracture but was still able to walk until 4 months before presentation at our hospital. The patient had difficulty walking without experiencing trauma and was diagnosed with an anterior dislocation due to reduction of lumbar lordosis and severe posterior pelvic tilt. Because the dislocation could not be reduced at the other hospital, the patient was admitted to our hospital for treatment.
Physical findings at the time of her first visit to our hospital included height of 148 cm, weight of 38 kg, and body mass index of 17.4 kg/m2. There was no tenderness at the femoral triangle, her left leg was shortened in external rotation, she had limited range of motion (ROM; 70 ° of flexion, − 10 ° of extension and 10 ° of abduction) in her left hip joint, and she was unable to keep standing. An X-ray image of her hip in the supine position showed anterior dislocation of the hemi-arthroplasty with severe posterior pelvic tilt (Fig. 1). An X-ray image of her lumbar spine showed a wedge-shaped compression fracture of the fifth lumbar vertebra due to osteoporosis and reduction of lumbar lordosis. The small bone fragment in the anterior part of the acetabulum indicated the occurrence of a dislocation fracture due to stress concentration on the anterior wall of the acetabulum.
The anterior pelvic plane (APP), defined as a plane through the bilateral anterior superior iliac spines to the pubic symphysis, was regarded as the anatomic plane of the pelvis in this patient. The angle between the APP and the coronal plane passing through the bilateral anterior superior iliac spines (ASIS) was defined as the sagittal pelvic tilt angle (APP tilting angle) in the supine or standing position. CT data and the Zed Hip system (Lexi, Japan) showed that the APP tilting angle in this patient at admission was 38 degrees posterior in the supine position.
We planned to transform hemi-arthroplasty into THA because anterior coverage with reduced cup anteversion was required for the prevention of anterior dislocation in this case. Due to the severe posterior tilting of the pelvis, cup positioning was planned preoperatively (Fig. 2). Because there was no evidence suggesting the loosening of the femoral component, the stem was planned to be retained. CT showed that the anteversion angle of the stem on the femoral table top plane was 16 degrees. Based on a previously published method of calculation [2, 3], we planned radiographic cup positioning angle to be 40 degrees of inclination and 26 degrees of anteversion relative to the functional pelvic plane (FPP), which was defined as the coronal plane passing through the bilateral ASIS in the supine position. The anatomic cup positioning angle was planned to be 37.3 degrees of inclination and − 8.3 degrees of anteversion, whereas the radiographic cup positioning angle was planned to be 37 degrees of inclination and − 5 degrees of anteversion and the operative cup positioning angle was planned to be 36.8 degrees of inclination and − 6.3 degrees of anteversion, relative to the APP based on a previously published method [4]. Preoperative planning using the Stryker navigation system (Stryker, MI) [2, 4], a CT-based hip navigation system (Fig. 2). We did not perform ROM simulation before surgery because the patient’s implant was already dislocated at the presence to our hospital and the CT data cannot to be used for the ROM simulation.
The operation was performed using a direct lateral approach. The stem was retained after confirmation of rigid stability during surgery. Exposure of the acetabulum revealed a bone defect in its anterior wall. A 46 mm cup was inserted at 37 degrees of inclination and − 5 degrees of anteversion relative to the APP, as determined radiographically using navigation. Because some patients experience progressive posterior changes in pelvic tilt after surgery, the dual mobility MDM X3 Mobile Bearing Hip System (Stryker, MI) was utilized to reduce the risk of re-dislocation. Intraoperative press fit on acetabular implant was adequate for initial stability.
The patient started standing and walking rehabilitation the day after the operation. Three months later, she was able to walk short distances without pain and had a Harris Hip score (HHS) of 78 points. Measurement of her APP tilting angle showed progressive posterior pelvic tilting after the operation (Fig. 3), with CT 1 year later showing an APP tilting angle of 47 degrees in the supine position. Three years after the operation, EOS imaging (Paris, France) showed that her APP tilting angle was 60 degrees posterior in the standing position (Fig. 4). The sagittal view of EOS imaging showed the angle between APP and femoral shaft was measured to be − 66 degrees (66 degrees extension), indicating hyperextension of the femur in the standing position. The maximum ROM of this patient was assessed by the Zed Hip system. Implant-to-implant impingement was observed at a flexion of 99 degrees and an extension of 68 degrees relative to the APP (Fig. 5), indicating a high risk of posterior impingement in the standing position. Gait analysis was also performed 3 years after surgery using VICON612 (Vicon Motion Systems, Oxford, UK) and plug-in-gait marker placement [5]. The hip joint angle was defined as the angle between the APP and the femoral bone axis. The left hip joint was hyperextended relative to the right hip (Fig. 6), although the patient was still able to walk for short distances without pain. At the final follow up of three years after operation, hip flexion, extension, inner rotation and external rotation angle and HHS were improved to 90 °, 0 °, 20 ° and 0 °, and was 74 points.

Discussion

Hip dislocation after THA or hemi-arthroplasty is a rare but serious complication. Dislocation may be prevented by appropriate positioning of the cup angle of inclination and anteversion [2, 68]. Because sagittal pelvic tilt significantly affects functional cup inclination and anteversion, it is necessary to consider changes of pelvic tilt for accurate cup placement. Although most patients who undergo THA do not experience postural changes in pelvic tilt, some patients may experience severe changes in pelvic tilt from the supine to the standing position, which may result in anterior dislocation following THA [9]. In most patients, the coronal plane in the supine position can act as the FPP for planning of the cup angle [9]. THA patients with small lumbo-lordotic angle have tendency of time course change of posterior pelvic tilt after surgery [1, 3]. In this case, because the patient had a reduced-lumbar lordosis, postoperative posterior pelvic change was expected and then, the change was considered in preoperative planning of cup positioning [1, 3].
Our report describes a patient who experienced anterior dislocation after hemi-arthroplasty. Previously, less than − 10 ° of APP angle was considered to increase the anterior dislocation in standing position [3], therefore, our current patient was considered having the severe posterior pelvic tilt that resulted in anterior dislocation. In the previous reports, late postoperative dislocation of THA due to severe posterior tilt were treated by revision THA with elevated liner or optimization of cup anteversion [10] or use of dual mobility cup [11]. In our case, she underwent revision THA using a CT-based navigation system for the appropriate cup positioning in combination with a dual mobility cup. In this patient, the coronal plane in the supine position was considered the FPP, because she had difficulty standing due to hip dislocation and had a severe posterior pelvic tilt in the supine position. Thus, radiographic preoperative planning of cup placement resulted in an inclination of 40 degrees and an anteversion of 26 degrees relative to the FPP (the coronal plane in the supine position), whereas anatomic preoperative planning of cup placement resulted in an inclination of 37.3 degrees and an anteversion of − 8.3 degrees relative to the APP. A dual mobility cup was utilized in this patient to prevent dislocation due to progressive posterior changes in pelvic tilt. This patient experienced a progressive posterior change in pelvic tilt after the operation from the supine position preoperatively to the standing position postoperatively. Interestingly, the change in pelvic tilt resulted in hyperextension of the femur, as she did not experience a compensational change in knee flexion.
Evaluation of global alignment using an EOS imaging system showed that the extension angle of the femur was 66 degrees relative to the APP, indicating an increased risk of bone-to-bone or implant-to-implant impingement in the standing position. This may have been due to the extension of ROM resulting from reduced cup anteversion, the surgical removal of the impinging bone, and/or the surgical improvement in contractions. ROM simulation using the Zed Hip system indicated that femoral extension of 68 degrees relative to the APP resulted in implant-to-implant impingement. Gait analysis demonstrated femoral hyperextension while walking. These results indicated that the risk of posterior impingement was high in this patient.
CT-based navigation was reportedly useful tool for the accurate placement of implants during THA [12, 13]. Appropriate implant positioning is important in preventing dislocation, therefore, cup planning should be planned considering the progressive posterior change of pelvic tilt in patients with severe posterior pelvic tilt.
We utilized dual mobility cup in the current case, because dual mobility cups reportedly reduce dislocation rate after THA [11, 14]. Although dual mobility cup may not be suitable for young patients or re-revision cases [15], it may be a useful option for the prevention of dislocation for patients with severe posterior pelvic tilt.

Conclusion

This report describes a patient who underwent THA using CT-based navigation for dislocation after hemi-arthroplasty with a posterior pelvic tilt. Implant planning in patients with preoperative posterior pelvic tilt should consider possible progressive postoperative posterior changes in pelvic tilt while standing. Dual mobility cups may be useful in patients at risk of dislocation.

Acknowledgments

Not applicable.
Not applicable.
Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor of this journal.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Suzuki H, Inaba Y, Kobayashi N, Ishida T, Ike H, Saito T. Postural and chronological change in pelvic tilt five years after Total hip Arthroplasty in patients with developmental dysplasia of the hip: a three-dimensional analysis. J Arthroplast. 2016;31:317–22.CrossRef Suzuki H, Inaba Y, Kobayashi N, Ishida T, Ike H, Saito T. Postural and chronological change in pelvic tilt five years after Total hip Arthroplasty in patients with developmental dysplasia of the hip: a three-dimensional analysis. J Arthroplast. 2016;31:317–22.CrossRef
2.
Zurück zum Zitat Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004;22:815–21.CrossRef Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004;22:815–21.CrossRef
3.
Zurück zum Zitat Inaba Y, Kobayashi N, Suzuki H, Ike H, Kubota S, Saito T. Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation. BMC Musculoskelet Disord. 2016;17:280.CrossRef Inaba Y, Kobayashi N, Suzuki H, Ike H, Kubota S, Saito T. Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation. BMC Musculoskelet Disord. 2016;17:280.CrossRef
4.
Zurück zum Zitat Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br Vol. 1993;75:228–32.CrossRef Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br Vol. 1993;75:228–32.CrossRef
5.
Zurück zum Zitat Davis RB, OS, Tyburski D, Gage JR. A gait analysis data collection and reduction technique. Hum Mov Sci. 1991;10(5):575–87.CrossRef Davis RB, OS, Tyburski D, Gage JR. A gait analysis data collection and reduction technique. Hum Mov Sci. 1991;10(5):575–87.CrossRef
6.
Zurück zum Zitat Yoshimine F. The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech. 2006;39:1315–23.CrossRef Yoshimine F. The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech. 2006;39:1315–23.CrossRef
7.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–20.CrossRef Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–20.CrossRef
8.
Zurück zum Zitat Dorr LD, Malik A, Dastane M, Wan Z. Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009;467:119–27.CrossRef Dorr LD, Malik A, Dastane M, Wan Z. Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009;467:119–27.CrossRef
9.
Zurück zum Zitat Nishihara S, Sugano N, Nishii T, Ohzono K, Yoshikawa H. Measurements of pelvic flexion angle using three-dimensional computed tomography. Clin Orthop Relat Res. 2003;411:140–51. Nishihara S, Sugano N, Nishii T, Ohzono K, Yoshikawa H. Measurements of pelvic flexion angle using three-dimensional computed tomography. Clin Orthop Relat Res. 2003;411:140–51.
10.
Zurück zum Zitat Kobayashi H, Nakashima Y, Yamamoto T, et al. Late anterior dislocation due to posterior pelvic tilt in Total hip Arthroplasty. Open Orthop J. 2016;10:206–12.CrossRef Kobayashi H, Nakashima Y, Yamamoto T, et al. Late anterior dislocation due to posterior pelvic tilt in Total hip Arthroplasty. Open Orthop J. 2016;10:206–12.CrossRef
11.
Zurück zum Zitat Carulli C, Macera A, Matassi F, Civinini R, Innocenti M. The use of a dual mobility cup in the management of recurrent dislocations of hip hemiarthroplasty. J Orthop Traumatol. 2016;17:131–6.CrossRef Carulli C, Macera A, Matassi F, Civinini R, Innocenti M. The use of a dual mobility cup in the management of recurrent dislocations of hip hemiarthroplasty. J Orthop Traumatol. 2016;17:131–6.CrossRef
12.
Zurück zum Zitat Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br Vol. 2006;88:163–7.CrossRef Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br Vol. 2006;88:163–7.CrossRef
13.
Zurück zum Zitat Gurgel HM, Croci AT, Cabrita HA, Vicente JR, Leonhardt MC, Rodrigues JC. Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomized and controlled study. J Arthroplast. 2014;29:167–71.CrossRef Gurgel HM, Croci AT, Cabrita HA, Vicente JR, Leonhardt MC, Rodrigues JC. Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomized and controlled study. J Arthroplast. 2014;29:167–71.CrossRef
14.
Zurück zum Zitat Epinette JA. Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up. J Arthroplast. 2015;30:241–8.CrossRef Epinette JA. Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up. J Arthroplast. 2015;30:241–8.CrossRef
15.
Zurück zum Zitat Hailer NP, Weiss RJ, Stark A, Karrholm J. Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation: 228 patients from the Swedish hip Arthroplasty register. Acta Orthop. 2012;83:566–71.CrossRef Hailer NP, Weiss RJ, Stark A, Karrholm J. Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation: 228 patients from the Swedish hip Arthroplasty register. Acta Orthop. 2012;83:566–71.CrossRef
Metadaten
Titel
Utility of CT-based navigation in revision total hip arthroplasty for a patient with severe posterior pelvic tilt-case report-
verfasst von
Shintaro Watanabe
Hyonmin Choe
Naomi Kobayashi
Hiroyuki Ike
Daigo Kobayashi
Syota Higashihira
Yutaka Inaba
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
BMC Musculoskeletal Disorders / Ausgabe 1/2020
Elektronische ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-020-03263-9

Weitere Artikel der Ausgabe 1/2020

BMC Musculoskeletal Disorders 1/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.