Background

The survivorship of total elbow arthroplasties is lower than surgeons and patients would like it to be, especially in patients with posttraumatic arthritis of the elbow. To improve durability, it is important to understand the failure modes of existing implants. Total elbow arthroplasties were designed primarily for low-demand rheumatoid patients. As surgical indications have extended to more active patient populations, the mechanical performance of current designs must meet an increased mechanical burden. Evaluating the degree to which they do this will guide conclusions about which contemporary devices might still meet the need and, as importantly, what design and material changes might be needed to improve performance.

Where Are We Now?

The reasons for failures of total elbow arthroplasties include infection, loosening, polyethylene wear, locking mechanism failure, periprosthetic fracture, implant fracture, and instability. Implant design factors that have influenced wear include implant constraint, material, coatings, and metal backing. Surgical factors associated with increased wear and subsequent total elbow arthroplasty failure include soft tissue balancing and restoration of alignment and implant positioning.

Where Do We Need to Go?

A clear need exists for improving the performance of total elbow arthroplasty. Many of the failures that have limited the survivorship of elbow arthroplasties thus far are mechanical in nature with wear-related problems a dominating influence. Much of what we know about the results of total elbow arthroplasty is from small studies frequently involving the designer of the implant. The establishment of total elbow arthroplasty registries coupled with the increasing regulatory burden of postmarket surveillance would lead to a better understanding of the complications and survivorship of elbow arthroplasties. Another primary goal must be to achieve a better understanding of the biomechanics of the normal elbow and how the mechanics are altered after the insertion of elbow arthroplasty components.

How Do We Get There?

Improving the performance and survivorship of total elbow arthroplasty will require the integration of clinical and implant performance data gained through the establishment of registries with a concerted basic science effort to better understand the functional loads across the joint and to incorporate these loads into experimental and computational models to allow assessment of design and material changes intended to improve durability.
Literatur
1.
Zurück zum Zitat Athwal GS, Morrey BF. Revision total elbow arthroplasty for prosthetic fractures. J Bone Joint Surg Am. 2006;88:2017–2026.PubMedCrossRef Athwal GS, Morrey BF. Revision total elbow arthroplasty for prosthetic fractures. J Bone Joint Surg Am. 2006;88:2017–2026.PubMedCrossRef
2.
Zurück zum Zitat Brownhill JR, Pollock JW, Ferreira LM, Johnson JA, King GJ. The effect of implant malalignment on joint loading in total elbow arthroplasty: an in vitro study. J Shoulder Elbow Surg. 2012;21:1032–1038.PubMedCrossRef Brownhill JR, Pollock JW, Ferreira LM, Johnson JA, King GJ. The effect of implant malalignment on joint loading in total elbow arthroplasty: an in vitro study. J Shoulder Elbow Surg. 2012;21:1032–1038.PubMedCrossRef
3.
Zurück zum Zitat Celli A, Morrey BF. Total elbow arthroplasty in patients forty years of age or less. J Bone Joint Surg Am. 2009;91:1414–1418.PubMedCrossRef Celli A, Morrey BF. Total elbow arthroplasty in patients forty years of age or less. J Bone Joint Surg Am. 2009;91:1414–1418.PubMedCrossRef
4.
Zurück zum Zitat Degreef I, Sciot R, De Smet L. Metallosis in revision total elbow arthroplasty. Complications and staging method. Acta Orthop Belg. 2008;74:753–760.PubMed Degreef I, Sciot R, De Smet L. Metallosis in revision total elbow arthroplasty. Complications and staging method. Acta Orthop Belg. 2008;74:753–760.PubMed
5.
Zurück zum Zitat Ewald FC, Simmons ED Jr, Sullivan JA, Thomas WH, Scott RD, Poss R, Thornhill TS, Sledge CB. Capitellocondylar total elbow replacement in rheumatoid arthritis. Long-term results. J Bone Joint Surg Am. 1993;75:498–507.PubMed Ewald FC, Simmons ED Jr, Sullivan JA, Thomas WH, Scott RD, Poss R, Thornhill TS, Sledge CB. Capitellocondylar total elbow replacement in rheumatoid arthritis. Long-term results. J Bone Joint Surg Am. 1993;75:498–507.PubMed
6.
Zurück zum Zitat Fevang BT, Lie SA, Havelin LI, Skredderstuen A, Furnes O. Results after 562 total elbow replacements: a report from the Norwegian Arthroplasty Register. J Shoulder Elbow Surg. 2009;18:449–456.PubMedCrossRef Fevang BT, Lie SA, Havelin LI, Skredderstuen A, Furnes O. Results after 562 total elbow replacements: a report from the Norwegian Arthroplasty Register. J Shoulder Elbow Surg. 2009;18:449–456.PubMedCrossRef
7.
Zurück zum Zitat Figgie HE 3rd, Inglis AE, Mow C. A critical analysis of alignment factors affecting functional outcome in total elbow arthroplasty. J Arthroplasty. 1986;1:169–173.PubMedCrossRef Figgie HE 3rd, Inglis AE, Mow C. A critical analysis of alignment factors affecting functional outcome in total elbow arthroplasty. J Arthroplasty. 1986;1:169–173.PubMedCrossRef
8.
Zurück zum Zitat Figgie MP, Gerwin M, Weiland AJ. Revision total elbow replacement. Hand Clin. 1994;10:507–520.PubMed Figgie MP, Gerwin M, Weiland AJ. Revision total elbow replacement. Hand Clin. 1994;10:507–520.PubMed
9.
Zurück zum Zitat Figgie MP, Su EP, Kahn B, Lipman J. Locking mechanism failure in semiconstrained total elbow arthroplasty. J Shoulder Elbow Surg. 2006;15:88–93.PubMedCrossRef Figgie MP, Su EP, Kahn B, Lipman J. Locking mechanism failure in semiconstrained total elbow arthroplasty. J Shoulder Elbow Surg. 2006;15:88–93.PubMedCrossRef
10.
Zurück zum Zitat Futai K, Tomita T, Yamazaki T, Murase T, Yoshikawa H, Sugamoto K. In vivo three-dimensional kinematics of total elbow arthroplasty using fluoroscopic imaging. Int Orthop. 2010;34:847–854.PubMedCentralPubMedCrossRef Futai K, Tomita T, Yamazaki T, Murase T, Yoshikawa H, Sugamoto K. In vivo three-dimensional kinematics of total elbow arthroplasty using fluoroscopic imaging. Int Orthop. 2010;34:847–854.PubMedCentralPubMedCrossRef
11.
Zurück zum Zitat Gill DR, Morrey BF. The Coonrad-Morrey total elbow arthroplasty in patients who have rheumatoid arthritis. A ten to fifteen-year follow-up study. J Bone Joint Surg Am. 1998;80:1327–1335.PubMedCrossRef Gill DR, Morrey BF. The Coonrad-Morrey total elbow arthroplasty in patients who have rheumatoid arthritis. A ten to fifteen-year follow-up study. J Bone Joint Surg Am. 1998;80:1327–1335.PubMedCrossRef
12.
Zurück zum Zitat Goldberg SH, Urban RM, Jacobs JJ, King GJ, O’Driscoll SW, Cohen MS. Modes of wear after semi-constrained total elbow arthroplasty. J Bone Joint Surg Am. 2008;90:609–619.PubMedCrossRef Goldberg SH, Urban RM, Jacobs JJ, King GJ, O’Driscoll SW, Cohen MS. Modes of wear after semi-constrained total elbow arthroplasty. J Bone Joint Surg Am. 2008;90:609–619.PubMedCrossRef
13.
Zurück zum Zitat Goodman SB, Wright TM. Osteolysis and implant wear: biological, biomedical engineering, and surgical principles. J Am Acad Orthop Surg. 2008;16(Suppl):x–xi. Goodman SB, Wright TM. Osteolysis and implant wear: biological, biomedical engineering, and surgical principles. J Am Acad Orthop Surg. 2008;16(Suppl):x–xi.
14.
Zurück zum Zitat Gschwend N, Scheier NH, Baehler AR. Long-term results of the GSB III elbow arthroplasty. J Bone Joint Surg Br. 1999;81:1005–1012.PubMedCrossRef Gschwend N, Scheier NH, Baehler AR. Long-term results of the GSB III elbow arthroplasty. J Bone Joint Surg Br. 1999;81:1005–1012.PubMedCrossRef
15.
Zurück zum Zitat Heyse TJ, Ries MD, Bellemans J, Goodman SB, Scott RD, Wright TM, Lipman JD, Schwarzkopf R, Figgie MP. Total knee arthroplasty in patients with juvenile idiopathic arthritis. Clin Orthop Relat Res. 2014;472:147–154.PubMedCrossRef Heyse TJ, Ries MD, Bellemans J, Goodman SB, Scott RD, Wright TM, Lipman JD, Schwarzkopf R, Figgie MP. Total knee arthroplasty in patients with juvenile idiopathic arthritis. Clin Orthop Relat Res. 2014;472:147–154.PubMedCrossRef
16.
Zurück zum Zitat Ikävalko M, Tiihonen R, Skyttä ET, Belt EA. Long-term survival of the Souter-Strathclyde total elbow replacement in patients with rheumatoid arthritis. J Bone Joint Surg Br. 2010;92:656–660.PubMedCrossRef Ikävalko M, Tiihonen R, Skyttä ET, Belt EA. Long-term survival of the Souter-Strathclyde total elbow replacement in patients with rheumatoid arthritis. J Bone Joint Surg Br. 2010;92:656–660.PubMedCrossRef
17.
Zurück zum Zitat Jeon IH, Morrey BF, Sanchez-Sotelo J. Ulnar component surface finish influenced the outcome of primary Coonrad-Morrey total elbow arthroplasty. J Shoulder Elbow Surg. 2012;21:1229–1235.PubMedCrossRef Jeon IH, Morrey BF, Sanchez-Sotelo J. Ulnar component surface finish influenced the outcome of primary Coonrad-Morrey total elbow arthroplasty. J Shoulder Elbow Surg. 2012;21:1229–1235.PubMedCrossRef
18.
Zurück zum Zitat Kudo H, Iwano K, Nishino J. Cementless or hybrid total elbow arthroplasty with titanium-alloy implants. A study of interim clinical results and specific complications. J Arthroplasty. 1994;9:269–278.PubMedCrossRef Kudo H, Iwano K, Nishino J. Cementless or hybrid total elbow arthroplasty with titanium-alloy implants. A study of interim clinical results and specific complications. J Arthroplasty. 1994;9:269–278.PubMedCrossRef
19.
Zurück zum Zitat Kudo H, Iwano K, Nishino J. Total elbow arthroplasty with use of a nonconstrained humeral component inserted without cement in patients who have rheumatoid arthritis. J Bone Joint Surg Am. 1999;81:1268–1280.PubMed Kudo H, Iwano K, Nishino J. Total elbow arthroplasty with use of a nonconstrained humeral component inserted without cement in patients who have rheumatoid arthritis. J Bone Joint Surg Am. 1999;81:1268–1280.PubMed
20.
Zurück zum Zitat Landor I, Vavrik P, Jahoda D, Guttler K, Sosna A. Total elbow replacement with the Souter-Strathclyde prosthesis in rheumatoid arthritis. Long-term follow-up. J Bone Joint Surg Br. 2006;88:1460–1463.PubMedCrossRef Landor I, Vavrik P, Jahoda D, Guttler K, Sosna A. Total elbow replacement with the Souter-Strathclyde prosthesis in rheumatoid arthritis. Long-term follow-up. J Bone Joint Surg Br. 2006;88:1460–1463.PubMedCrossRef
21.
Zurück zum Zitat Lee BP, Adams RA, Morrey BF. Polyethylene wear after total elbow arthroplasty. J Bone Joint Surg Am. 2005;87:1080–1087.PubMedCrossRef Lee BP, Adams RA, Morrey BF. Polyethylene wear after total elbow arthroplasty. J Bone Joint Surg Am. 2005;87:1080–1087.PubMedCrossRef
22.
Zurück zum Zitat Little CP, Graham AJ, Karatzas G, Woods DA, Carr AJ. Outcomes of total elbow arthroplasty for rheumatoid arthritis: comparative study of three implants. J Bone Joint Surg Am. 2005;87:2439–2448.PubMedCrossRef Little CP, Graham AJ, Karatzas G, Woods DA, Carr AJ. Outcomes of total elbow arthroplasty for rheumatoid arthritis: comparative study of three implants. J Bone Joint Surg Am. 2005;87:2439–2448.PubMedCrossRef
23.
Zurück zum Zitat Morrey BF, Adams RA, Bryan RS. Total replacement for post-traumatic arthritis of the elbow. J Bone Joint Surg Br. 1991;73:607–612.PubMed Morrey BF, Adams RA, Bryan RS. Total replacement for post-traumatic arthritis of the elbow. J Bone Joint Surg Br. 1991;73:607–612.PubMed
24.
Zurück zum Zitat Patil N, Cheung EV, Mow CS. High revision rate after total elbow arthroplasty with a linked semiconstrained device. Orthopedics. 2009;32:321.PubMedCrossRef Patil N, Cheung EV, Mow CS. High revision rate after total elbow arthroplasty with a linked semiconstrained device. Orthopedics. 2009;32:321.PubMedCrossRef
25.
Zurück zum Zitat Rasmussen JV, Olsen BS, Fevang BT, Furnes O, Skytta ET, Rahme H, Salomonsson B, Mohammed KD, Page RS, Carr AJ. A review of national shoulder and elbow joint replacement registries. J Shoulder Elbow Surg. 2012;21:1328–1335.PubMedCrossRef Rasmussen JV, Olsen BS, Fevang BT, Furnes O, Skytta ET, Rahme H, Salomonsson B, Mohammed KD, Page RS, Carr AJ. A review of national shoulder and elbow joint replacement registries. J Shoulder Elbow Surg. 2012;21:1328–1335.PubMedCrossRef
26.
Zurück zum Zitat Reinhard R, van der Hoeven M, de Vos MJ, Eygendaal D. Total elbow arthroplasty with the Kudo prosthesis. Int Orthop. 2003;27:370–372.PubMedCentralPubMedCrossRef Reinhard R, van der Hoeven M, de Vos MJ, Eygendaal D. Total elbow arthroplasty with the Kudo prosthesis. Int Orthop. 2003;27:370–372.PubMedCentralPubMedCrossRef
27.
Zurück zum Zitat Robinson E, Burke N, Douglas P, Orr J, Pooley J. Mechanism of loosening of the Souter-Strathclyde total elbow replacement evidence from revision surgery. Acta Orthop Belg. 2010;76:27–29.PubMed Robinson E, Burke N, Douglas P, Orr J, Pooley J. Mechanism of loosening of the Souter-Strathclyde total elbow replacement evidence from revision surgery. Acta Orthop Belg. 2010;76:27–29.PubMed
28.
Zurück zum Zitat Rozing P. Souter-Strathclyde total elbow arthroplasty. J Bone Joint Surg Br. 2000;82:1129–1134.PubMedCrossRef Rozing P. Souter-Strathclyde total elbow arthroplasty. J Bone Joint Surg Br. 2000;82:1129–1134.PubMedCrossRef
29.
Zurück zum Zitat Sayed-Noor AS, Sjödén GO. Severe metallosis after total elbow arthroplasty—a case report. Hand (NY). 2010;5:86–89.CrossRef Sayed-Noor AS, Sjödén GO. Severe metallosis after total elbow arthroplasty—a case report. Hand (NY). 2010;5:86–89.CrossRef
30.
Zurück zum Zitat Schneeberger AG, Adams R, Morrey BF. Semiconstrained total elbow replacement for the treatment of post-traumatic osteoarthrosis. J Bone Joint Surg Am. 1997;79:1211–1222.PubMed Schneeberger AG, Adams R, Morrey BF. Semiconstrained total elbow replacement for the treatment of post-traumatic osteoarthrosis. J Bone Joint Surg Am. 1997;79:1211–1222.PubMed
31.
Zurück zum Zitat Schuind F, O’Driscoll S, Korinek S, An KN, Morrey BF. Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics. J Arthroplasty. 1995;10:670–678.PubMedCrossRef Schuind F, O’Driscoll S, Korinek S, An KN, Morrey BF. Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics. J Arthroplasty. 1995;10:670–678.PubMedCrossRef
32.
Zurück zum Zitat Seitz WH Jr, Bismar H, Evans PJ. Failure of the hinge mechanism in total elbow arthroplasty. J Shoulder Elbow Surg. 2010;19:368–375.PubMedCrossRef Seitz WH Jr, Bismar H, Evans PJ. Failure of the hinge mechanism in total elbow arthroplasty. J Shoulder Elbow Surg. 2010;19:368–375.PubMedCrossRef
33.
Zurück zum Zitat Shah BM, Trail IA, Nuttal D, Stanley JK. The effect of epidemiologic and intraoperative factors on survival of the standard Souter-Strathclyde total elbow arthroplasty. J Arthroplasty. 2000;15:994–998.PubMedCrossRef Shah BM, Trail IA, Nuttal D, Stanley JK. The effect of epidemiologic and intraoperative factors on survival of the standard Souter-Strathclyde total elbow arthroplasty. J Arthroplasty. 2000;15:994–998.PubMedCrossRef
34.
Zurück zum Zitat Shi LL, Zurakowski D, Jones DG, Koris MJ, Thornhill TS. Semicontrained primary and revision total elbow arthroplasty with use of the Coonrad-Morrey prosthesis. J Bone Joint Surg Am. 2007;89:1467–1475.PubMedCrossRef Shi LL, Zurakowski D, Jones DG, Koris MJ, Thornhill TS. Semicontrained primary and revision total elbow arthroplasty with use of the Coonrad-Morrey prosthesis. J Bone Joint Surg Am. 2007;89:1467–1475.PubMedCrossRef
35.
Zurück zum Zitat Skyttä ET, Eskelinen A, Paavolainen P, Ikävalko M, Remes V. Total elbow arthroplasty in rheumatoid arthritis: a population-based study from the Finnish Arthroplasty Register. Acta Orthop. 2009;80:472–477.PubMedCentralPubMedCrossRef Skyttä ET, Eskelinen A, Paavolainen P, Ikävalko M, Remes V. Total elbow arthroplasty in rheumatoid arthritis: a population-based study from the Finnish Arthroplasty Register. Acta Orthop. 2009;80:472–477.PubMedCentralPubMedCrossRef
36.
Zurück zum Zitat Stokdijk M, Meskers CGM, Veeger HEJ, deBoer YA, Rozing PM. Determination of the optimal elbow axis for evaluation of placement of prostheses. Clin Biomech. 1999;14:177–184. Stokdijk M, Meskers CGM, Veeger HEJ, deBoer YA, Rozing PM. Determination of the optimal elbow axis for evaluation of placement of prostheses. Clin Biomech. 1999;14:177–184.
37.
Zurück zum Zitat Tanaka N, Kudo H, Iwano K, Sakahashi H, Sato E, Ishii S. Kudo total elbow arthroplasty in patients with rheumatoid arthritis: a long-term follow-up study. J Bone Joint Surg Am. 2001;83:1506–1513.PubMedCrossRef Tanaka N, Kudo H, Iwano K, Sakahashi H, Sato E, Ishii S. Kudo total elbow arthroplasty in patients with rheumatoid arthritis: a long-term follow-up study. J Bone Joint Surg Am. 2001;83:1506–1513.PubMedCrossRef
38.
Zurück zum Zitat Throckmorton T, Zarkadas P, Sanchez-Sotelo J, Morrey B. Failure patterns after linked semiconstrained total elbow arthroplasty for posttraumatic arthritis. J Bone Joint Surg Am. 2010;92:1432–1441.PubMedCrossRef Throckmorton T, Zarkadas P, Sanchez-Sotelo J, Morrey B. Failure patterns after linked semiconstrained total elbow arthroplasty for posttraumatic arthritis. J Bone Joint Surg Am. 2010;92:1432–1441.PubMedCrossRef
39.
Zurück zum Zitat van der Lugt JCT, Valstar ER, Witvoet-Braam SW, Nelissen RGHH. Migration of the humeral component of the Souter-Strathclyde elbow prosthesis. J Bone Joint Surg-Br. 2010;92:235–241.PubMedCrossRef van der Lugt JCT, Valstar ER, Witvoet-Braam SW, Nelissen RGHH. Migration of the humeral component of the Souter-Strathclyde elbow prosthesis. J Bone Joint Surg-Br. 2010;92:235–241.PubMedCrossRef
40.
Zurück zum Zitat van Riet RP, Morrey BF, O’Driscoll SW. The Pritchard ERS total elbow prosthesis: lessons to be learned from failure. J Shoulder Elbow Surg. 2009;18:791–795.PubMedCrossRef van Riet RP, Morrey BF, O’Driscoll SW. The Pritchard ERS total elbow prosthesis: lessons to be learned from failure. J Shoulder Elbow Surg. 2009;18:791–795.PubMedCrossRef
41.
Zurück zum Zitat Willing R, King GJ, Johnson JA. The effect of implant design of linked total elbow arthroplasty on stability and stress: a finite element analysis. Comput Methods Biomech Biomed Eng. 2014;17:1165–1172.CrossRef Willing R, King GJ, Johnson JA. The effect of implant design of linked total elbow arthroplasty on stability and stress: a finite element analysis. Comput Methods Biomech Biomed Eng. 2014;17:1165–1172.CrossRef
42.
Zurück zum Zitat Wright TM, Goodman SB. Implant Wear: The Future of Total Joint Replacement. Rosemont, IL, USA: American Academy of Orthopaedic Surgeons; 1996. Wright TM, Goodman SB. Implant Wear: The Future of Total Joint Replacement. Rosemont, IL, USA: American Academy of Orthopaedic Surgeons; 1996.
43.
Zurück zum Zitat Wright TM, Goodman SB. Implant Wear in Total Joint Replacement: Clinical and Biologic Issues, Materials and Design Considerations. Rosemont, IL, USA: American Academy of Orthopaedic Surgeons; 2001. Wright TM, Goodman SB. Implant Wear in Total Joint Replacement: Clinical and Biologic Issues, Materials and Design Considerations. Rosemont, IL, USA: American Academy of Orthopaedic Surgeons; 2001.
44.
Zurück zum Zitat Wright TW, Hastings H. Total elbow arthroplasty failure due to overuse, C-ring failure, and/or bushing wear. J Shoulder Elbow Surg. 2005;14:65–72.PubMedCrossRef Wright TW, Hastings H. Total elbow arthroplasty failure due to overuse, C-ring failure, and/or bushing wear. J Shoulder Elbow Surg. 2005;14:65–72.PubMedCrossRef
Metadaten
Titel
What Design and Material Factors Impact the Wear and Corrosion Performance in Total Elbow Arthroplasties?
verfasst von
Mark P. Figgie, MD
Timothy M. Wright, PhD
Denise Drinkwater, BA
The Bioengineering Working Group
Publikationsdatum
01.12.2014
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 12/2014
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-014-3781-9

Weitere Artikel der Ausgabe 12/2014

Clinical Orthopaedics and Related Research® 12/2014 Zur Ausgabe

Symposium: ABJS Carl T. Brighton Workshop on Implant Wear and Tribocorrosion of Total Joint Replacements

Which Design and Biomaterial Factors Affect Clinical Wear Performance of Total Disc Replacements? A Systematic Review

Symposium: ABJS Carl T. Brighton Workshop on Implant Wear and Tribocorrosion of Total Joint Replacements

How Have New Bearing Surfaces Altered the Local Biological Reactions to Byproducts of Wear and Modularity?

Symposium: ABJS Carl T. Brighton Workshop on Implant Wear and Tribocorrosion of Total Joint Replacements

How Have Alternative Bearings and Modularity Affected Revision Rates in Total Hip Arthroplasty?

Symposium: Award Papers from Turkish Society of Orthopaedics and Traumatology 2013

Apical and Intermediate Anchors Without Fusion Improve Cobb Angle and Thoracic Kyphosis in Early-onset Scoliosis

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.