Skip to main content
Erschienen in: Osteoporosis International 3/2013

01.03.2013 | Original Article

3D characterization of pores in the cortical bone of human femur in the elderly at different locations as determined by synchrotron micro-computed tomography images

verfasst von: C. Chappard, S. Bensalah, C. Olivier, P. J. Gouttenoire, A. Marchadier, C. Benhamou, F. Peyrin

Erschienen in: Osteoporosis International | Ausgabe 3/2013

Einloggen, um Zugang zu erhalten

Abstract

Summary

Diaphysis, inferior, and lateral superior regions of the femoral neck are subjected to diverse mechanical loads. Using micro-CT based on synchrotron radiation, three-dimensional morphology and connectivity of the pore network are location dependent, underlying different remodeling mechanisms.

Introduction

The three-dimensional (3D) morphology and connectivity of the pore network at various locations in human femurs subjected to diverse mechanical loads were assessed using micro-CT based on synchrotron radiation.

Methods

The cortex from 20 human femurs (mean age, 78.3 ± 12.4 years) was taken from the diaphysis (D), the inferior (IN), and the lateral superior (LS) regions of the femoral neck. The voxel size of the 3D reconstructed image was 7.5 μm. Cortical thickness and pore volume/tissue volume (Po.V/TV), pore diameter (Po.Dm) and spacing (Po.Sp) were determined. The pore surface/pore volume ratio (Po.S/Po.V), the number of pores (Po.N), the degrees of anisotropy (DA), and the connectivity density (ConnD), the degree of mineralization (DMB) were also determined.

Results

The characteristics of the pore network in femoral cortical bone were found to be location dependent. There was greater porosity, Po.Dm, and Po.N, and more large (180–270 μm), extra-large (270–360 μm) and giant pores (>360 μm) in the LS compared to the IN and D. The difference in porosity in between the periosteal and endosteal layers was mostly due to an increase of Po.Dm rather than Po.N. There was a lower DMB of bone in the LS, which is consistent with a higher remodeling rate.

Conclusion

The results provide evidence for large variations in the structure of the internal pore network in cortical bone. These variations could involve different underlying remodeling mechanisms.
Literatur
1.
Zurück zum Zitat Cummings SR, Melton LJ (2002) Epidemiology and outcomes of osteoporotic fractures. Lancet 359:1761–1767, ReviewPubMedCrossRef Cummings SR, Melton LJ (2002) Epidemiology and outcomes of osteoporotic fractures. Lancet 359:1761–1767, ReviewPubMedCrossRef
2.
Zurück zum Zitat Holzer G, von Skrbensky G, Holzer LA, Pichl W (2009) Hip fractures and the contribution of cortical versus trabecular bone to femoral neck strength. J Bone Miner Res 24:468–474PubMedCrossRef Holzer G, von Skrbensky G, Holzer LA, Pichl W (2009) Hip fractures and the contribution of cortical versus trabecular bone to femoral neck strength. J Bone Miner Res 24:468–474PubMedCrossRef
3.
Zurück zum Zitat Schaffler MB, Burr DB (1988) Stiffness of compact bone: effects of porosity and density. J Biomech 21:13–16PubMedCrossRef Schaffler MB, Burr DB (1988) Stiffness of compact bone: effects of porosity and density. J Biomech 21:13–16PubMedCrossRef
4.
Zurück zum Zitat Martin RB, Ishida J (1989) The relative effects of collagen fiber orientation, porosity, density, and mineralization on bone strength. J Biomech 22:419–426PubMedCrossRef Martin RB, Ishida J (1989) The relative effects of collagen fiber orientation, porosity, density, and mineralization on bone strength. J Biomech 22:419–426PubMedCrossRef
5.
Zurück zum Zitat McCalden RW, McGeough JA, Barker MB, Court-Brown CM (1993) Age-related changes in the tensile properties of cortical bone. The relative importance of changes in porosity, mineralization, and microstructure. J Bone Joint Surg Am 75:1193–1205PubMed McCalden RW, McGeough JA, Barker MB, Court-Brown CM (1993) Age-related changes in the tensile properties of cortical bone. The relative importance of changes in porosity, mineralization, and microstructure. J Bone Joint Surg Am 75:1193–1205PubMed
6.
Zurück zum Zitat Yeni YN, Norman TL (2000) Fracture toughness of human femoral neck: effect of microstructure, composition, and age. Bone 26:499–504, Erratum in: Bone 2000 27:327PubMedCrossRef Yeni YN, Norman TL (2000) Fracture toughness of human femoral neck: effect of microstructure, composition, and age. Bone 26:499–504, Erratum in: Bone 2000 27:327PubMedCrossRef
7.
Zurück zum Zitat Stout SD, Brunsden BS, Hildebolt CF, Commean PK, Smith KE, Tappen NC (1999) Computer-assisted 3D reconstruction of serial sections of cortical bone to determine the 3D structure of osteons. Calcif Tissue Int 65:280–284PubMedCrossRef Stout SD, Brunsden BS, Hildebolt CF, Commean PK, Smith KE, Tappen NC (1999) Computer-assisted 3D reconstruction of serial sections of cortical bone to determine the 3D structure of osteons. Calcif Tissue Int 65:280–284PubMedCrossRef
8.
Zurück zum Zitat Müller R (2009) Hierarchical microimaging of bone structure and function. Nat Rev Rheumatol 5:373–381PubMedCrossRef Müller R (2009) Hierarchical microimaging of bone structure and function. Nat Rev Rheumatol 5:373–381PubMedCrossRef
9.
Zurück zum Zitat Bousson V, Peyrin F, Bergot C, Haussard M, Sautet A, Laredo J (2004) Cortical bone in the human femoral neck: three-dimensional appearance and porosity using synchrotron radiation. J Bone Miner Res 19:794–801PubMedCrossRef Bousson V, Peyrin F, Bergot C, Haussard M, Sautet A, Laredo J (2004) Cortical bone in the human femoral neck: three-dimensional appearance and porosity using synchrotron radiation. J Bone Miner Res 19:794–801PubMedCrossRef
10.
Zurück zum Zitat Cooper DM, Erickson B, Peele AG, Hannah K, Thomas CD, Clement JG (2011) Visualization of 3D osteon morphology by synchrotron radiation micro-CT. J Anat 219:481–489PubMedCrossRef Cooper DM, Erickson B, Peele AG, Hannah K, Thomas CD, Clement JG (2011) Visualization of 3D osteon morphology by synchrotron radiation micro-CT. J Anat 219:481–489PubMedCrossRef
11.
Zurück zum Zitat Wachter NJ, Augat P, Krischak GD, Mentzel M, Kinzl L, Claes L (2001) Prediction of cortical bone porosity in vitro by microcomputed tomography. Calcif Tissue Int 68:38–42PubMedCrossRef Wachter NJ, Augat P, Krischak GD, Mentzel M, Kinzl L, Claes L (2001) Prediction of cortical bone porosity in vitro by microcomputed tomography. Calcif Tissue Int 68:38–42PubMedCrossRef
12.
Zurück zum Zitat Cooper DML, Turinsky AML, Jensen CW, Hallgrimsson B (2003) Quantitative 3D analysis of the canal network in cortical bone by microcomputed tomography. Anat Rec 274:169–179CrossRef Cooper DML, Turinsky AML, Jensen CW, Hallgrimsson B (2003) Quantitative 3D analysis of the canal network in cortical bone by microcomputed tomography. Anat Rec 274:169–179CrossRef
13.
Zurück zum Zitat Cooper DM, Thomas CD, Clement JG, Turinsky AL, Sensen CW, Hallgrímsson B (2007) Age-dependent change in the 3D structure of cortical porosity at the human femoral midshaft. Bone 40:957–965PubMedCrossRef Cooper DM, Thomas CD, Clement JG, Turinsky AL, Sensen CW, Hallgrímsson B (2007) Age-dependent change in the 3D structure of cortical porosity at the human femoral midshaft. Bone 40:957–965PubMedCrossRef
14.
Zurück zum Zitat Cooper D, Turinsky A, Sensen C, Hallgrimsson B (2007) Effect of voxel size on 3D micro-CT analysis of cortical bone porosity. Calcif Tissue Int 80:211–219PubMedCrossRef Cooper D, Turinsky A, Sensen C, Hallgrimsson B (2007) Effect of voxel size on 3D micro-CT analysis of cortical bone porosity. Calcif Tissue Int 80:211–219PubMedCrossRef
15.
Zurück zum Zitat Basillais A, Bensamoun S, Chappard C, Brunet-Imbault B, Lemineur G, Ilharreborde B, Ho Ba Tho M, Benhamou C (2007) Three-dimensional characterization of cortical bone microstructure by microcomputed tomography: validation with ultrasonic and microscopic measurements. J Orthop Sci 12:141–148PubMedCrossRef Basillais A, Bensamoun S, Chappard C, Brunet-Imbault B, Lemineur G, Ilharreborde B, Ho Ba Tho M, Benhamou C (2007) Three-dimensional characterization of cortical bone microstructure by microcomputed tomography: validation with ultrasonic and microscopic measurements. J Orthop Sci 12:141–148PubMedCrossRef
16.
Zurück zum Zitat Chen H, Zhou X, Shoumura S, Emura S, Bunai Y (2010) Age- and gender-dependent changes in three-dimensional microstructure of cortical and trabecular bone at the human femoral neck. Osteoporos Int 21:627–636PubMedCrossRef Chen H, Zhou X, Shoumura S, Emura S, Bunai Y (2010) Age- and gender-dependent changes in three-dimensional microstructure of cortical and trabecular bone at the human femoral neck. Osteoporos Int 21:627–636PubMedCrossRef
17.
Zurück zum Zitat Zebaze RM, Ghasem-Zadeh A, Bohte A, Iuliano-Burns S, Mirams M, Price RI, Mackie EJ, Seeman E (2010) Intracortical remodelling and porosity in the distal radius and post-mortem femurs of women: a cross-sectional study. Lancet 15:1729–1736CrossRef Zebaze RM, Ghasem-Zadeh A, Bohte A, Iuliano-Burns S, Mirams M, Price RI, Mackie EJ, Seeman E (2010) Intracortical remodelling and porosity in the distal radius and post-mortem femurs of women: a cross-sectional study. Lancet 15:1729–1736CrossRef
18.
Zurück zum Zitat Currey JD (2002) Bone: structure and mechanics. Chapter 1. Princeton University Press, Princeton Currey JD (2002) Bone: structure and mechanics. Chapter 1. Princeton University Press, Princeton
19.
Zurück zum Zitat Brown CU, Yeni YN, Norman TL (1998) Fracture toughness of the femoral neck, femoral shaft, and tibial shaft in aged bone. Adv Bioeng 39:279–280 Brown CU, Yeni YN, Norman TL (1998) Fracture toughness of the femoral neck, femoral shaft, and tibial shaft in aged bone. Adv Bioeng 39:279–280
20.
Zurück zum Zitat Lotz JC, Cheal EJ, Hayes WC (1995) Stress distributions within the proximal femur during gait and falls: implications for osteoporotic fracture. Osteoporos Int 5:252–261PubMedCrossRef Lotz JC, Cheal EJ, Hayes WC (1995) Stress distributions within the proximal femur during gait and falls: implications for osteoporotic fracture. Osteoporos Int 5:252–261PubMedCrossRef
21.
Zurück zum Zitat Mayhew PM, Thomas CD, Clement JG, Loveridge N, Beck TJ, Bonfield W, Burgoyne CJ, Reeve J (2005) Relation between age, femoral neck cortical stability, and hip fracture risk. Lancet 366:129–135PubMedCrossRef Mayhew PM, Thomas CD, Clement JG, Loveridge N, Beck TJ, Bonfield W, Burgoyne CJ, Reeve J (2005) Relation between age, femoral neck cortical stability, and hip fracture risk. Lancet 366:129–135PubMedCrossRef
22.
Zurück zum Zitat Nuzzo S, Peyrin F, Cloetens P, Baruchel J, Boivin G (2002) Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography. Med Phys 29:2672–2681PubMedCrossRef Nuzzo S, Peyrin F, Cloetens P, Baruchel J, Boivin G (2002) Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography. Med Phys 29:2672–2681PubMedCrossRef
23.
Zurück zum Zitat Chappard C, Basillais A, Benhamou L, Bonassie A, Brunet-Imbault B, Bonnet N, Peyrin F (2006) Comparison of synchrotron radiation and conventional x-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads. Med Phys 33:3568–3577PubMedCrossRef Chappard C, Basillais A, Benhamou L, Bonassie A, Brunet-Imbault B, Bonnet N, Peyrin F (2006) Comparison of synchrotron radiation and conventional x-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads. Med Phys 33:3568–3577PubMedCrossRef
24.
Zurück zum Zitat Salome M, Peyrin F, Cloetens P, Odet C, Laval-Jeantet AM, Baruchel J, Spanne P (1999) A synchrotron radiation microtomography system for the analysis of trabecular bone samples. Med Phys 26:2194–2204PubMedCrossRef Salome M, Peyrin F, Cloetens P, Odet C, Laval-Jeantet AM, Baruchel J, Spanne P (1999) A synchrotron radiation microtomography system for the analysis of trabecular bone samples. Med Phys 26:2194–2204PubMedCrossRef
25.
Zurück zum Zitat Hildebrand T (1997) A new method for the model independent assessment of thickness in three dimensional images. J Microsc 185:67–75CrossRef Hildebrand T (1997) A new method for the model independent assessment of thickness in three dimensional images. J Microsc 185:67–75CrossRef
26.
Zurück zum Zitat Lorensen WE, Cline HE (1988) Marching cubes: a high resolution 3D surface construction algorithm. Comput Graph 21(Suppl 1):7–12 Lorensen WE, Cline HE (1988) Marching cubes: a high resolution 3D surface construction algorithm. Comput Graph 21(Suppl 1):7–12
27.
Zurück zum Zitat Ulrich D, Van Rietbergen B, Laib A, Ruegsegger P (1999) The ability of three dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone 25:55–60PubMedCrossRef Ulrich D, Van Rietbergen B, Laib A, Ruegsegger P (1999) The ability of three dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone 25:55–60PubMedCrossRef
28.
Zurück zum Zitat Whitehouse WJ (1974) The quantitative morphology of anisotropic trabecular bone. J Microsc 101:153–156PubMedCrossRef Whitehouse WJ (1974) The quantitative morphology of anisotropic trabecular bone. J Microsc 101:153–156PubMedCrossRef
29.
Zurück zum Zitat Odgaard A (1997) Three-dimensional methods for quantification of cancellous bone architecture. Bone 20:315–328PubMedCrossRef Odgaard A (1997) Three-dimensional methods for quantification of cancellous bone architecture. Bone 20:315–328PubMedCrossRef
30.
Zurück zum Zitat Odgaard A, Gundersen HJ (1993) Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions. Bone 14:173–182PubMedCrossRef Odgaard A, Gundersen HJ (1993) Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions. Bone 14:173–182PubMedCrossRef
31.
Zurück zum Zitat Norman GR, Streiner DL (2000) Biostatistics: the bare essentials. BC Becker Inc Norman GR, Streiner DL (2000) Biostatistics: the bare essentials. BC Becker Inc
32.
Zurück zum Zitat Cooper DM, Matyas JR, Katzenberg MA, Hallgrimsson B (2004) Comparison of microcomputed tomographic and microradiographic measurements of cortical bone porosity. Calcif Tissue Int 74:437–447PubMedCrossRef Cooper DM, Matyas JR, Katzenberg MA, Hallgrimsson B (2004) Comparison of microcomputed tomographic and microradiographic measurements of cortical bone porosity. Calcif Tissue Int 74:437–447PubMedCrossRef
33.
Zurück zum Zitat Peyrin F, Salome M, Nuzzo S, Cloetens P, Laval-Jeantet AM, Baruchel J (2000) Perspectives in three-dimensional analysis of bone samples using synchrotron radiation microtomography. Cell Mol Biol 46:1089–1102PubMed Peyrin F, Salome M, Nuzzo S, Cloetens P, Laval-Jeantet AM, Baruchel J (2000) Perspectives in three-dimensional analysis of bone samples using synchrotron radiation microtomography. Cell Mol Biol 46:1089–1102PubMed
34.
Zurück zum Zitat Szulc P, Seeman E (2009) Thinking inside and outside the envelopes of bone. Osteoporos Int 20:1281–1288PubMedCrossRef Szulc P, Seeman E (2009) Thinking inside and outside the envelopes of bone. Osteoporos Int 20:1281–1288PubMedCrossRef
35.
Zurück zum Zitat Bell KL, Loveridge N, Power J, Garrahan N, Meggitt BF, Reeve J (1999) Regional differences in cortical porosity in the fractured femoral neck. Bone 24:57–64PubMedCrossRef Bell KL, Loveridge N, Power J, Garrahan N, Meggitt BF, Reeve J (1999) Regional differences in cortical porosity in the fractured femoral neck. Bone 24:57–64PubMedCrossRef
36.
Zurück zum Zitat Stein M, Feik S, Thomas C, Clement J, Wark J (1999) An automated analysis of intracortical porosity in human femoral bone across age. J Bone Miner Res 14:624–632PubMedCrossRef Stein M, Feik S, Thomas C, Clement J, Wark J (1999) An automated analysis of intracortical porosity in human femoral bone across age. J Bone Miner Res 14:624–632PubMedCrossRef
37.
Zurück zum Zitat Pfeiffer S, Crowder C, Harrington L, Brown M (2006) Secondary osteon and Haversian canal dimensions as behavioral indicators. Am J Phys Anthropol 131:460–468PubMedCrossRef Pfeiffer S, Crowder C, Harrington L, Brown M (2006) Secondary osteon and Haversian canal dimensions as behavioral indicators. Am J Phys Anthropol 131:460–468PubMedCrossRef
38.
Zurück zum Zitat Bell KL, Loveridge N, Reeve J, Thomas CD, Feik SA, Clement JG (2001) Super-osteons (remodeling clusters) in the cortex of the femoral shaft: influence of age and gender. Anat Rec 264:378–386PubMedCrossRef Bell KL, Loveridge N, Reeve J, Thomas CD, Feik SA, Clement JG (2001) Super-osteons (remodeling clusters) in the cortex of the femoral shaft: influence of age and gender. Anat Rec 264:378–386PubMedCrossRef
39.
Zurück zum Zitat Orwoll ES (2003) Toward an expanded understanding of the role of the periosteum in skeletal health. J Bone Miner Res 18:949–954, ReviewPubMedCrossRef Orwoll ES (2003) Toward an expanded understanding of the role of the periosteum in skeletal health. J Bone Miner Res 18:949–954, ReviewPubMedCrossRef
40.
Zurück zum Zitat Allen MR, Burr DB (2005) Human femoral neck has less cellular periosteum, and more mineralized periosteum, than femoral diaphyseal bone. Bone 36:311–316PubMedCrossRef Allen MR, Burr DB (2005) Human femoral neck has less cellular periosteum, and more mineralized periosteum, than femoral diaphyseal bone. Bone 36:311–316PubMedCrossRef
41.
Zurück zum Zitat Muller R, Van Campenhout H, Van Damme B, Van Der Perre G, Dequeker J, Hildebrand T, Ruegsegger P (1998) Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography. Bone 23:59–66PubMedCrossRef Muller R, Van Campenhout H, Van Damme B, Van Der Perre G, Dequeker J, Hildebrand T, Ruegsegger P (1998) Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography. Bone 23:59–66PubMedCrossRef
42.
Zurück zum Zitat Thomas CD, Feik S, Clement JG (2006) Increase in pore area, and not pore density, is the main determinant in the development of porosity in human cortical bone. J Anat 209:219–230PubMedCrossRef Thomas CD, Feik S, Clement JG (2006) Increase in pore area, and not pore density, is the main determinant in the development of porosity in human cortical bone. J Anat 209:219–230PubMedCrossRef
43.
Zurück zum Zitat Peter Z, Bousson V, Bergot C, Peyrin F (2008) A constrained region growing approach based on watershed for the segmentation of low contrast structures in bone micro-CT images. Pattern Recogn 41:2358–2368CrossRef Peter Z, Bousson V, Bergot C, Peyrin F (2008) A constrained region growing approach based on watershed for the segmentation of low contrast structures in bone micro-CT images. Pattern Recogn 41:2358–2368CrossRef
Metadaten
Titel
3D characterization of pores in the cortical bone of human femur in the elderly at different locations as determined by synchrotron micro-computed tomography images
verfasst von
C. Chappard
S. Bensalah
C. Olivier
P. J. Gouttenoire
A. Marchadier
C. Benhamou
F. Peyrin
Publikationsdatum
01.03.2013
Verlag
Springer-Verlag
Erschienen in
Osteoporosis International / Ausgabe 3/2013
Print ISSN: 0937-941X
Elektronische ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-012-2044-4

Weitere Artikel der Ausgabe 3/2013

Osteoporosis International 3/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.