Skip to main content
Erschienen in: Journal of Cardiothoracic Surgery 1/2019

Open Access 01.12.2019 | Case report

3D printing and thoracoscopy assisted MIPO in treatment of long-range comminuted rib fractures, a case report

verfasst von: Xuetao Zhou, Dongsheng Zhang, Zexin Xie, Menghui Chen, Yang Yang, Zheng Liang, Guoliang Zhang

Erschienen in: Journal of Cardiothoracic Surgery | Ausgabe 1/2019

Abstract

Background

To investigate the application of 3D printing technology combined with percutaneous Minimally Invasive Plate Oseoynthesis (MIPO) and thoracoscopic techniques in the treatment of long comminuted rib fractures.

Case presentation

One case of multiple rib fractures with abnormal respiratory disease (including rib 3 and 4 of long comminuted fractures) due to a fall injury was selected. The 3D model of comminuted rib fracture was reconstructed and printed according to the thin-layer CT scan results. After the fracture model was restored to the normal rib anatomy, the metal plate was accurately shaped according to the 3D rib shape.

Conclusions

3D printing technology combined with MIPO technology under thoracoscopy in the minimally invasive treatment of long-range comminuted rib fractures, greatly reduced the time and improved the accuracy of intraoperative fixation, reduced the difficulty of surgery, patient injury, and perfectly reconstructed the chest wall. Application of the 3D printing technique to make the rib model and pre-mold the metal plate combined the thoracoscopic MIPO technology provides less invasive and accurate individualized treatment for complex rib fractures.
Abkürzungen
MIPO
Minimally Invasive Plate Oseoynthesis

Background

The traditional treatment of rib fractures is mainly conservative treatment [1].In recent years, with the continuous availability of new rib internal fixation materials and equipment, the development of surgical treatment has been greatly promoted, and the operation has also been simplified and minimally invasive [2]. The indications for internal fixation of rib fractures have also been constantly updated and broadened [3], but high rib fractures, especially behind the scapula, are complex and challenging issues for the surgeon. Traditional operation methods are not only difficult to operate, but also cause great damage to patients. However; the MIPO technique does not break the skin of the fracture end, and fix the fracture through the periosteal subcutaneous tunnel without destroying the blood supply of periosteum. With the rapid development of minimally invasive techniques in various medical fields, the use of orthopaedic MIPO technology and thoracoscopic technology, combined with 3D printing technology to rebuild the 3D model, preoperatively shaping the metal bone plate brings great convenience to surgery and greatly reduces patient injury.

Case presentation

Typical case

The patient was a 61-year-old man with multiple left rib fractures (1–6 ribs), left pneumothorax, left lung contusion, and left thoracic subcutaneous emphysema due to a fall injury. The examination showed a partial depression in the left front rib and abnormal breathing (see Fig. 1).
Admission chest CT examination: 1–6 rib fractures on the left side (of which 3, 4 ribs are long comminuted fractures (see Fig. 2)); left pneumothorax, left traumatic wet lung; a small amount of liquid pneumothorax on the left side.
Patient was given early chest straps, multiparametric monitoring, analgesia, and oxygen therapy. The chest pain was still severe. The visual analogue scale scored 7–8 points for the pain at rest and 9 points for the cough.

Surgical methods

Physical examination revealed that the left chest wall was recessed and abnormally breathed. The CT scan of the rib showed a long comminuted fracture of 3 and 4 ribs. The key to successful operation was the reduction and fixation of these two rib fractures. A preoperative CT scan was performed to reconstruct the 3D model based on the scan results (see Fig. 3), and 3D printing technology was used to prepare 3 and 4 rib models (see Fig. 4). The three D print models of each fracture segment of the two ribs were adherently reconstructed.
The two rib metal plates were separately shaped according to the reconstruction model (see Figs. 5 and 6).
The patient is scheduled to have a open reduction and internal fixation of 3–6 rib fracture. After general anesthesia, right side lying position, small incision about 8 cm was performed under the edge of 4th rib underarm. The skin was sequentially incised and the subcutaneous tissue was freed layer by layer. The front of the latissimus dorsi muscle and the anterior serratus were exposed. The tunnel was established on the 3rd and 4th rib surfaces from the back of the chest and small muscles to the back of the scapula. The special long hooks lifted the scapula and exposed the scapular operation space. With assistance of endoscope, the electrocautery is useful to expose 3 cm outside the outermost fracture lines of the 3 and 4 ribs. The locking plate was molded on the surface of the third rib before operation, and the broken end of the non-fracture at the anterior and posterior portions of the third rib was well fitted. The distance between the two ends of the metal bone plate exceeded the fracture line to 3 nail holes distance. Under the thoracoscope, the metal plate and the ribs were temporarily fixed with long-angled forceps. The MIPO system was used to drill the holes. Two screws were implanted and locked at both ends to firmly fix the metal plate. In turn, each fracture segment was reset and drilled and secured to a metal plate. The fourth rib is fixed in the same way. Intraoperative image (Figs. 7, and 8). 5, 6 rib fractures given to fix the ribs, not the content of this article, not elaborated. Sufficient to stop the bleeding, the wound was given to leave a negative pressure drainage tube. After a routine thoracoscopic probe of the chest cavity, a closed thoracic drainage tube was placed posterior to the 7th intercostal space and the incision was closed layer by layer. After the chest wall is well-shaped. Three days after surgery review the map (Fig. 9).

Discussion and conclusions

Rib fractures are most common in chest injuries, accounting for 40 to 60% thoracic injuries [4]. Surgical treatment of complex rib fractures has become a routine method. However, for long segment, superior, and comminuted rib fractures, due to the complex anatomical location, conventional surgical operations are more difficult and patients have greater surgical injury.
The thorax is a complex three-dimensional structure, and the ribs also have relatively special anatomical characteristics. In addition to the conventional anatomical parameters such as length and width, bending angle and longitudinal twisting angle are also important parameters. Although the commonly used fixtures have been greatly improved, it is still difficult to fully comply with the normal physiological and anatomical characteristics of three-dimensional bending and twisting of the ribs. For long segments and crushed rib fractures, the ribs have been severely deformed, and the basis for the shaping of the fixed material has been lost, causing great difficulties for surgery, and repeated adjustment of fixed materials increases the operation time and trauma. In particular, if the poor shape of the internal fixation is poor and the two ends of the fracture are poorly attached, the internal fixation body will have a distorted tension, and the ribs are weak and continuous moving. All these will easily lead to unscrewing and fixation (see Fig. 10).
The 3D printing technology has already brought about big improvements in various fields of medicine, especially orthopaedics [57] and also thoracic surgery [811]. This study used 3D printing technology, preoperative CT thin-layer scanning, reconstruction of 3D models based on scan results, and preparation of rib models using 3D printing techniques. The fractures were modeled before the reconstruction of the normal rib morphology. Reshape the ribbed metal plate according to the reconstruction model. During the operation, the shaped metal plate is fixed on the ribs outside the fracture line to establish the basic frame, and then the other fracture segments are respectively reset and fixed on the metal plate, which saves time and labor, and is satisfactory in shaping.
Especially for long upper rib fractures, due to the anatomical relationship between scapula and other anatomies, traditional surgical methods are difficult and traumatic [12]. With the help of thoracoscopy, only a small space is needed to perfectly reveal the area under the scapula, and the fractured end is well exposed. It is easier to complete the rib drilling fixation with the MIPO system [2], especially in combination with the above-mentioned 3D printing technology for pre-shaping the steel plate. And individualized treatments provide new methods.
In summary, the combination of 3D printing technology and MIPO technology in the minimally invasive treatment of long comminuted rib fractures assisted by thoracoscopy, greatly reduced the time and improved the accuracy of intraoperative fixed plastics, reducing the difficulty of surgery and patient injury. The method still needs more clinical experience to provide better services for the majority of patients.

Acknowledgements

N/A.

Funding

2019 Medical Science Research Key Project Program Directory of Hebei Province.

Availability of data and materials

All data generated or analysed during this study are included in this published article.
N/A.
We have obtained consent to publish from the participant to report individual patient data (including images).

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Mayberry JC, et al. Surveyed opinion of American trauma, orthopedic, and thoracic surgeons on rib and sternal fracture repair. J Trauma. 2009;66(3):875–9.CrossRef Mayberry JC, et al. Surveyed opinion of American trauma, orthopedic, and thoracic surgeons on rib and sternal fracture repair. J Trauma. 2009;66(3):875–9.CrossRef
2.
Zurück zum Zitat Bemelman M, et al. The role of minimally invasive plate Osteosynthesis in rib fixation: a review. Korean J Thorac Cardiovasc Surg. 2016;49(1):1–8.CrossRef Bemelman M, et al. The role of minimally invasive plate Osteosynthesis in rib fixation: a review. Korean J Thorac Cardiovasc Surg. 2016;49(1):1–8.CrossRef
3.
Zurück zum Zitat Nirula R, et al. Rib fracture repair: indications, technical issues, and future directions. World J Surg. 2009;33(1):14–22.CrossRef Nirula R, et al. Rib fracture repair: indications, technical issues, and future directions. World J Surg. 2009;33(1):14–22.CrossRef
4.
Zurück zum Zitat Bemelman M, et al. Rib fractures: to fix or not to fix? An evidence-based algorithm. Korean J Thorac Cardiovasc Surg. 2017;50(4):229–34.CrossRef Bemelman M, et al. Rib fractures: to fix or not to fix? An evidence-based algorithm. Korean J Thorac Cardiovasc Surg. 2017;50(4):229–34.CrossRef
5.
Zurück zum Zitat Morris S. Future of 3D printing: how 3D bioprinting technology can revolutionize healthcare? Birth Defects Res. 2018;110(13):1098–101.CrossRef Morris S. Future of 3D printing: how 3D bioprinting technology can revolutionize healthcare? Birth Defects Res. 2018;110(13):1098–101.CrossRef
6.
Zurück zum Zitat Lieben L. Regenerative medicine: the future of 3D printing of human tissues is taking shape. Nat Rev Rheumatol. 2016;12(4):191.CrossRef Lieben L. Regenerative medicine: the future of 3D printing of human tissues is taking shape. Nat Rev Rheumatol. 2016;12(4):191.CrossRef
7.
Zurück zum Zitat Reighard CL, Hollister SJ, Zopf DA. Auricular reconstruction from rib to 3D printing. J 3D Print Med. 2018;2(1):35–41.CrossRef Reighard CL, Hollister SJ, Zopf DA. Auricular reconstruction from rib to 3D printing. J 3D Print Med. 2018;2(1):35–41.CrossRef
8.
Zurück zum Zitat Finotello A, Marconi S, Pane B, et al. Twelve-year follow-up post-thoracic endovascular repair in type B aortic dissection shown by three-dimensional printing. Ann Vasc Surg. 2019;55:309.e13–9.CrossRef Finotello A, Marconi S, Pane B, et al. Twelve-year follow-up post-thoracic endovascular repair in type B aortic dissection shown by three-dimensional printing. Ann Vasc Surg. 2019;55:309.e13–9.CrossRef
9.
Zurück zum Zitat Chen YY, Lin KH, Huang HK, et al. The beneficial application of preoperative 3D printing for surgical stabilization of rib fractures. PLoS One. 2018;13(10):e0204652.CrossRef Chen YY, Lin KH, Huang HK, et al. The beneficial application of preoperative 3D printing for surgical stabilization of rib fractures. PLoS One. 2018;13(10):e0204652.CrossRef
10.
Zurück zum Zitat Mendez A, Gomez-Ciriza G, Raboisson MJ, et al. Apical muscular ventricular septal defects: surgical strategy using three-dimensional printed model. Semin Thorac Cardiovasc Surg. 2018;30(4):450–3.CrossRef Mendez A, Gomez-Ciriza G, Raboisson MJ, et al. Apical muscular ventricular septal defects: surgical strategy using three-dimensional printed model. Semin Thorac Cardiovasc Surg. 2018;30(4):450–3.CrossRef
11.
Zurück zum Zitat Li H, Qingyao B, et al. Application of 3D printing technology to left atrial appendage occlusion. Int J Cardiol. 2017;231:258–63.CrossRef Li H, Qingyao B, et al. Application of 3D printing technology to left atrial appendage occlusion. Int J Cardiol. 2017;231:258–63.CrossRef
12.
Zurück zum Zitat de Jong MB, et al. Surgical Management of rib Fractures: strategies and literature review. Scand J Surg. 2014;103(2):120–5.CrossRef de Jong MB, et al. Surgical Management of rib Fractures: strategies and literature review. Scand J Surg. 2014;103(2):120–5.CrossRef
Metadaten
Titel
3D printing and thoracoscopy assisted MIPO in treatment of long-range comminuted rib fractures, a case report
verfasst von
Xuetao Zhou
Dongsheng Zhang
Zexin Xie
Menghui Chen
Yang Yang
Zheng Liang
Guoliang Zhang
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
Journal of Cardiothoracic Surgery / Ausgabe 1/2019
Elektronische ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-019-0892-0

Weitere Artikel der Ausgabe 1/2019

Journal of Cardiothoracic Surgery 1/2019 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.