Abstract

Screws, clamps and other spinal instrumentation materials are tested using healthy animal and healthy human vertebrae, but the application of similar tests to an osteoporotic vertebra is generally neglected because of high costs and limited availability of high quality and consistent osteoporotic vertebrae. The objective of this study is to develop an in-vitro method to decrease the mineral content of an animal vertebra utilizing decalcifying chemical agents that alters the bone mineral density and some biomechanical properties to such an extent that they biomechanically mimic the osteoporotic spine. This study was performed on 24 fresh calf lumbar vertebrae. Twelve out of these 24 vertebrae were demineralized and the others served as control. A hole was opened in the pedicles of each vertebrae and the bone mineral density was measured. Each vertebra was then placed into a beher-glass filled with hydrochloric acid decalcifier solution. The decalcifier solution was introduced through the holes in the pedicles with an infusion pump. The vertebrae were then subjected to DEXA to measure post process BMD. Pedicle screws were introduced into both pedicles of each vertebrae and pullout testing was performed at a rate of 5 mm/min. The difference of BMD measurements between pre- and post-demineralizing process were also statistically significant (p < 0.001). The difference of pullout loads between pre- and post-demineralizing process were also statistically significant (p < 0.001). The acid demineralizing process may be useful for producing a vertebra that has some biomechanical properties that are consistent with osteopenia or osteoporosis in humans.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Birkedal-Hansen H (1974) Kinetics of acid demineralization in histologic technique. J Histochem Cytochem 22(6):434–441PubMed Birkedal-Hansen H (1974) Kinetics of acid demineralization in histologic technique. J Histochem Cytochem 22(6):434–441PubMed
2.
Zurück zum Zitat Boivin G, Meunier PJ (2002) Effects of bisphosphonates on matrix mineralization. J Musculoskelet Neuronal Interact 2(6):538–543PubMed Boivin G, Meunier PJ (2002) Effects of bisphosphonates on matrix mineralization. J Musculoskelet Neuronal Interact 2(6):538–543PubMed
3.
Zurück zum Zitat Boskey AL (1992) Mineral-matrix interactions in bone and cartilage. Clin Orthop Relat Res 281:244–274PubMed Boskey AL (1992) Mineral-matrix interactions in bone and cartilage. Clin Orthop Relat Res 281:244–274PubMed
4.
Zurück zum Zitat Cook SD, Salkeld SL, Stanley T, Faciane A, Miller SD (2004) Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J 4(4):402–408PubMedCrossRef Cook SD, Salkeld SL, Stanley T, Faciane A, Miller SD (2004) Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J 4(4):402–408PubMedCrossRef
6.
Zurück zum Zitat Egermann M, Goldhahn J, Schneider E (2005) Animal models for fracture treatment in osteoporosis. Osteoporos Int 2(Suppl):S129–S138CrossRef Egermann M, Goldhahn J, Schneider E (2005) Animal models for fracture treatment in osteoporosis. Osteoporos Int 2(Suppl):S129–S138CrossRef
7.
Zurück zum Zitat Faibish D, Ott SM, Boskey AL (2006) Mineral changes in osteoporosis: a review. Clin Orthop Relat Res 443:28–38PubMedCrossRef Faibish D, Ott SM, Boskey AL (2006) Mineral changes in osteoporosis: a review. Clin Orthop Relat Res 443:28–38PubMedCrossRef
8.
Zurück zum Zitat Goldhahn J, Neuhoff D, Schaeren S, Steiner B, Linke B, Aebi M, Schneider E (2006) Osseointegration of hollow cylinder based spinal implants in normal and osteoporotic vertebrae: a sheep study. Arch Orthop Trauma Surg 126(8):554–561PubMedCrossRef Goldhahn J, Neuhoff D, Schaeren S, Steiner B, Linke B, Aebi M, Schneider E (2006) Osseointegration of hollow cylinder based spinal implants in normal and osteoporotic vertebrae: a sheep study. Arch Orthop Trauma Surg 126(8):554–561PubMedCrossRef
9.
Zurück zum Zitat Inceoglu S, Burghardt A, Akbay A, Majumdar S, McLain RF (2005) Trabecular architecture of lumbar vertebral pedicle. Spine 30(13):1485-1490PubMedCrossRef Inceoglu S, Burghardt A, Akbay A, Majumdar S, McLain RF (2005) Trabecular architecture of lumbar vertebral pedicle. Spine 30(13):1485-1490PubMedCrossRef
10.
Zurück zum Zitat Jee WS, Yao W (2001) Overview: animal models of osteopenia and osteoporosis. J Musculoskelet Neuronal Interact 1(3):193–207PubMed Jee WS, Yao W (2001) Overview: animal models of osteopenia and osteoporosis. J Musculoskelet Neuronal Interact 1(3):193–207PubMed
11.
Zurück zum Zitat Kettler A, Schmoelz W, Shezifi Y, Ohana N, Ben-Arye A, Claes L, Wilke HJ (2006) Biomechanical performance of the new BeadEx implant in the treatment of osteoporotic vertebral body compression fractures: restoration and maintenance of height and stability. Clin Biomech (Bristol, Avon) 21(7):676–682CrossRef Kettler A, Schmoelz W, Shezifi Y, Ohana N, Ben-Arye A, Claes L, Wilke HJ (2006) Biomechanical performance of the new BeadEx implant in the treatment of osteoporotic vertebral body compression fractures: restoration and maintenance of height and stability. Clin Biomech (Bristol, Avon) 21(7):676–682CrossRef
12.
Zurück zum Zitat Lewandrowski K, Tomford WW, Michaud NA, Schomacker KT, Deutsch TF (1997) An electron microscopic study on the process of acid demineralization of cortical bone. Calcif Tissue Int 61(4):294–297PubMedCrossRef Lewandrowski K, Tomford WW, Michaud NA, Schomacker KT, Deutsch TF (1997) An electron microscopic study on the process of acid demineralization of cortical bone. Calcif Tissue Int 61(4):294–297PubMedCrossRef
13.
Zurück zum Zitat Lewandrowski KU, Venugopalan V, Tomford WW, Schomacker KT, Mankin HJ, Deutsch TF (1996) Kinetics of cortical bone demineralization: controlled demineralization—a new method for modifying cortical bone allografts. J Biomed Mater Res 31(3):365–372PubMedCrossRef Lewandrowski KU, Venugopalan V, Tomford WW, Schomacker KT, Mankin HJ, Deutsch TF (1996) Kinetics of cortical bone demineralization: controlled demineralization—a new method for modifying cortical bone allografts. J Biomed Mater Res 31(3):365–372PubMedCrossRef
14.
Zurück zum Zitat Nayak S, Olkin I, Liu H, Grabe M, Gould MK, Allen IE, Owens DK, Bravata DM (2006) Meta-analysis: accuracy of quantitative ultrasound for identifying patients with osteoporosis. Ann Intern Med 6;144(11):832–841 Nayak S, Olkin I, Liu H, Grabe M, Gould MK, Allen IE, Owens DK, Bravata DM (2006) Meta-analysis: accuracy of quantitative ultrasound for identifying patients with osteoporosis. Ann Intern Med 6;144(11):832–841
15.
Zurück zum Zitat Nelson HD, Helfand M, Woolf SH, Allan JD (2002) Screening for postmenopausal osteoporosis: a review of the evidence for the US Preventive Services Task Force. Ann Intern Med 137(6):529–541 Summary for patients in: Ann Inter Med 17 September 2002 137(6):I59PubMed Nelson HD, Helfand M, Woolf SH, Allan JD (2002) Screening for postmenopausal osteoporosis: a review of the evidence for the US Preventive Services Task Force. Ann Intern Med 137(6):529–541 Summary for patients in: Ann Inter Med 17 September 2002 137(6):I59PubMed
16.
Zurück zum Zitat Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K (2001) Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J 1(6):402–407PubMedCrossRef Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K (2001) Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J 1(6):402–407PubMedCrossRef
17.
Zurück zum Zitat Priemel M, Schilling AF, Haberland M, Pogoda P, Rueger JM, Amling M (2002) Osteopenic mice: animal models of the aging skeleton. J Musculoskelet Neuronal Interact 2(3):212–218PubMed Priemel M, Schilling AF, Haberland M, Pogoda P, Rueger JM, Amling M (2002) Osteopenic mice: animal models of the aging skeleton. J Musculoskelet Neuronal Interact 2(3):212–218PubMed
18.
Zurück zum Zitat Reitman CA, Nguyen L, Fogel GR (2004) Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine. J Spinal Disord Tech 17(4):306–311PubMedCrossRef Reitman CA, Nguyen L, Fogel GR (2004) Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine. J Spinal Disord Tech 17(4):306–311PubMedCrossRef
19.
Zurück zum Zitat Seebeck J, Goldhahn J, Morlock MM, Schneider E (2005) Mechanical behavior of screws in normal and osteoporotic bone. Osteoporos Int 2(Suppl):S107–S111CrossRef Seebeck J, Goldhahn J, Morlock MM, Schneider E (2005) Mechanical behavior of screws in normal and osteoporotic bone. Osteoporos Int 2(Suppl):S107–S111CrossRef
20.
Zurück zum Zitat Swartz DE, Wittenberg RH, Shea M, White AA III, Hayes WC (1991) Physical and mechanical properties of calf lumbosacral trabecular bone. J Biomech 24(11):1059–1068PubMedCrossRef Swartz DE, Wittenberg RH, Shea M, White AA III, Hayes WC (1991) Physical and mechanical properties of calf lumbosacral trabecular bone. J Biomech 24(11):1059–1068PubMedCrossRef
21.
Zurück zum Zitat Turner AS (2001) Animal models of osteoporosis-necessity and limitations. Eur Cell Mater 22(1):66–81 Turner AS (2001) Animal models of osteoporosis-necessity and limitations. Eur Cell Mater 22(1):66–81
22.
Zurück zum Zitat Turner CH (2002) Determinants of skeletal fragility and bone quality. J Musculoskelet Neuronal Interact 2(6):527–528PubMed Turner CH (2002) Determinants of skeletal fragility and bone quality. J Musculoskelet Neuronal Interact 2(6):527–528PubMed
Metadaten
Titel
A demineralized calf vertebra model as an alternative to classic osteoporotic vertebra models for pedicle screw pullout studies
verfasst von
Atilla Akbay
Gokhan Bozkurt
Ozgur Ilgaz
Selcuk Palaoglu
Nejat Akalan
Edward C. Benzel
Publikationsdatum
01.03.2008
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 3/2008
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-007-0545-1

Weitere Artikel der Ausgabe 3/2008

European Spine Journal 3/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.