Skip to main content
Erschienen in: Journal of Cardiothoracic Surgery 1/2016

Open Access 01.12.2016 | Case report

A modified Park's stitch to correct aortic insufficiency for bioprosthetic valve at time of left ventricular assist device implant: a case report

verfasst von: Toshinobu Kazui, Nicole Sydow, Mark Friedman, Samuel Kim, Scott Lick, Zain Khalpey

Erschienen in: Journal of Cardiothoracic Surgery | Ausgabe 1/2016

Abstract

Background

Aortic valve insufficiency (AI) at the time of left ventricular assist device (LVAD) insertion needs to be corrected, however there is little known about how to manage bioprosthetic valvular AI.

Case presentation

A 55-year-old female with dilated cardiomyopathy who previously had a bioprosthetic aortic valve replacement needed a LVAD as a bridge to transplant. Her left ventricular ejection fraction was 10% and had mild to moderate transvalvular AI. She underwent a HeartWare HVAD insertion along with aortic valvular coaptation stitch repair (Park's stitch) to the bioprosthetic valve.

Conclusion

Her AI improved to trivial with minimal ejection through the bioprosthetic valve. She was transplanted 6 months following the surgery. A Park's stitch to the bioprosthetic aortic valve with more than mild AI might be a good option for bridge to transplant patient.

Background

Continuous flow left ventricular assist devices (LVADs) are known to cause progressive aortic valve commissural fusion as well as progressive aortic insufficiency with greater pump speeds and larger aortic root dimensions [1, 2]. Currently, consensus is to intervene on the aortic valve at the time of LVAD implant if the patient has more than mild aortic insufficiency (AI) (Class I, Level of Evidence C) [3]. The aortic valve can either be repaired or replaced with a bioprosthetic valve. The central coaptation repair stitch (Park’s stitch) has been shown to effectively and durably reduce the AI as well as improve survival, while maintaining aortic valve opening to allow ejection, without the additional cardiopulmonary bypass time that would be required for bioprosthetic valve replacement [4, 5]. This technique has typically been applied to native aortic valves in patients who present with significant AI at the time of LVAD implantation, but there is little known about the application of this technique to patients who present with bioprosthetic transvalvular aortic valve insufficiency at time of LVAD implant. This report demonstrates first clinical application of a Park’s stitch to a patient with a previous bioprosthetic aortic valve replacement (AVR) developing transvalvular AI.

Case presentation

A 55 year-old female with non-ischemic cardiomyopathy who initially presented with multiple syncopal episodes and increasing shortness of breath on exertion for the preceding 2 months. Her left ventricular ejection fraction (LVEF) was 20% at that time, with severe aortic stenosis and mild AI. Her aortic valve area was 1.0 cm2, with a peak gradient 16.9 mmHg and mean gradient 9.2 mmHg gradient. She underwent AVR with a 21 mm Mitroflow (Sorin, Milan, Italy) bioprosthetic valve with significant improvement in her symptoms (aortic valve area 1.8cm2, peak gradient 18.2 mmHg and mean gradient 9.0 mmHg).
Over the next 2 months, the patient had worsening heart failure with a decline in her LVEF to 15%. Her medical regimen was optimized with some improvement in her symptoms initially, however the improvement was short lived. Subsequent echocardiograms showed 15% LVEF, with new mild to moderate intra-valvular AI and mild perivalvular leak. Seven months after her AVR the patient was severely short of breath with declining ventricular function and mild to moderate AI. Her right ventricular function was severely depressed. The decision was made to insert HeartWare HVAD (Framingham, MA) with prosthetic aortic valve repair, Park’s stitch. Her INTERMACS profile was 3. Her pre operative platelet count, prothrombin time, and INR were 138 (1000/μl), 14.5 s, and 1.1. At the time of her LVAD insertion, the repair stitch was able to minimize her ischemic time to help preserve her RV. A pledgeted 4-0 Prolene (Ethicon, Cincinnati, OH) was placed to center of the each aortic valve leaflet. We could not appreciate perivalvular leak intraoperatively, however pledgeted mattressed 2-0 ethibond sutures were passed through from subvalvular leaflets to aortic wall and tied over pledgets. No obvious leaflet prolapse or perforation was noted (Fig. 1). The cardiopulmonary bypass time was 167 min and myocardial ischemic time was 52 min. Post-operatively, the patient had no AI on transesophageal echocardiogram as well as limited ejection through the aortic valve. The anticoagulation management was aspirin 325 mg/day and continuous heparin infusion based on thromboelastogram until Coumadin gets therapeutic, INR 2-3. She recovered well and was discharged home at postoperative day 27. At 4 months post HVAD insertion, the patient was feeling well with only trace AI on transthoracic echocardiogram. She developed lacunar infarction within the ventromedial nucleus of the right thalamus on 3 months after LVAD insertion. She was heart transplanted at 6 months following her LVAD insertion. Her aortic valve was fused and closed. No thrombus formation underneath the aortic valve was noted (Fig. 2).

Conclusion

Little has been known about management of recurrent AI after bioprosthetic AVR at the time of LVAD placement. A central coaptation stitch to these patients potentially is a good option for a bridge to transplant.
Short-term follow up in this patient shows promising results with only trace AI on echocardiogram. Although this technique has been shown to be a durable solution for patients with significant native aortic valve insufficiency [4], the long-term results of this technique especially in bioprosthetic valves remains to be seen to determine the durability of these results in the face of continued bioprosthetic valve degeneration.
Although there have been numerous studies of AI in LVAD patients, we don't know the long-term prognosis of patients who develops acquired AI. Since AI seemed to have negative impact on survival [1, 6], either bioprosthetic AVR or aortic valve repair is recommended for these patients. Patients with AI with following a previous bioprosthetic AVR, no recommendation is currently available. Performing a re-replacement bioprosthetic AVR may be more durable to prevent leaflet fusion, however explanting a previous valve and re-implant new valve in patients having an LVAD placement with concomitant severe RV dysfunction raises concerns about further impairing postoperative RV function. A Park's stitch to a bioprosthetic AVR is relatively easy, timely, safe and durable in LVAD patients being bridged to transplant.
This procedure was able to be performed in a quick and effective manner with short aortic cross clamp time to minimize the risk of RV dysfunction after LVAD placement.
The limitation of this technique in the setting of previous bioprosthetic AVR is no long-term mortality and morbidity data reported, therefore the application of this technique to destination patients should be cautious because of aortic valve leaflet fusion and potential thrombus formation below the fused aortic valve. If patients with AI from degenerating bioprosthetic AVR is listed as bridge to transplant, a Park's stitch to the bioprosthetic valve leaflets might be a good option to consider.
In conclusion, we reported a first successful case with Park's stitch and LVAD placement to previously placed bioprosthetic AVR. Further studies are mandatory to prove longevity and survival of this procedure in this context.

Acknowledgements

We would like to thank Destiny Dicken for her contribution on the submission process.

Funding

There was no funding for this case report.

Availability of data and materials

The data supporting the results is available.

Authors’ contributions

The individual contributions of authors to the manuscript should be specified in this section. TK: Performed the surgery, writing the manuscript, data collecting. NS: writing manuscript, data collecting. MF: patient management, correct the manuscript. SK: correct the manuscript. SL: performed the surgery, correct the manuscript. ZK: performed the surgery, correct the manuscript. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.
The consent for publication was obtained.
Manuscripts reporting studies involving human participants, human data or human tissue must: Include a statement on ethics approval and consent (even where the need for approval was waived). Per institutional protocol, ethics approval and consent was waived.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Rajagopal K, Daneshmand MA, Patel CB, Ganapathi AM, Schechter MA, Rogers JG, Milano CA. Natural history and clinical effect of aortic valve regurgitation after left ventricular assist device implantation. J Thorac Cardiovasc Surg. 2013;145:1373–9.CrossRefPubMed Rajagopal K, Daneshmand MA, Patel CB, Ganapathi AM, Schechter MA, Rogers JG, Milano CA. Natural history and clinical effect of aortic valve regurgitation after left ventricular assist device implantation. J Thorac Cardiovasc Surg. 2013;145:1373–9.CrossRefPubMed
2.
Zurück zum Zitat Mudd JO, Cuda JD, Halushka M, Soderlund KA, Conte JV, Russell SD. Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device. J Heart Lung Transplant. 2008;27:1269–74.CrossRefPubMed Mudd JO, Cuda JD, Halushka M, Soderlund KA, Conte JV, Russell SD. Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device. J Heart Lung Transplant. 2008;27:1269–74.CrossRefPubMed
3.
Zurück zum Zitat Goldstein DJ, Grady KL, Jones K, Hryniewicz K, John R, Kaan A, Kusne S, Loebe M, Massicotte MP, Moazami N, Mohacsi P, Mooney M, Nelson T, Pagani F, Perry W, Potapov EV, Eduardo Rame J, Russell SD, Sorensen EN, Sun B, Strueber M, Mangi AA, Petty MG, Rogers J, International Society for Heart and Lung Transplantation. The 2013 international society for heart and lung transplantation guidelines for mechanical circulatory support: Executive summary. J Heart Lung Transplant. 2013;32:157–87.CrossRefPubMed Goldstein DJ, Grady KL, Jones K, Hryniewicz K, John R, Kaan A, Kusne S, Loebe M, Massicotte MP, Moazami N, Mohacsi P, Mooney M, Nelson T, Pagani F, Perry W, Potapov EV, Eduardo Rame J, Russell SD, Sorensen EN, Sun B, Strueber M, Mangi AA, Petty MG, Rogers J, International Society for Heart and Lung Transplantation. The 2013 international society for heart and lung transplantation guidelines for mechanical circulatory support: Executive summary. J Heart Lung Transplant. 2013;32:157–87.CrossRefPubMed
4.
Zurück zum Zitat McKellar SH, Deo S, Daly RC, Durham 3rd LA, Joyce LD, Stulak JM, Park SJ. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices. J Thorac Cardiovasc Surg. 2014;147:344–8.CrossRefPubMed McKellar SH, Deo S, Daly RC, Durham 3rd LA, Joyce LD, Stulak JM, Park SJ. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices. J Thorac Cardiovasc Surg. 2014;147:344–8.CrossRefPubMed
5.
Zurück zum Zitat Park SJ, Liao KK, Segurola R, Madhu KP, Miller LW. Management of aortic insufficiency in patients with left ventricular assist devices: A simple coaptation stitch method (park's stitch). J Thorac Cardiovasc Surg. 2004;127:264–6.CrossRefPubMed Park SJ, Liao KK, Segurola R, Madhu KP, Miller LW. Management of aortic insufficiency in patients with left ventricular assist devices: A simple coaptation stitch method (park's stitch). J Thorac Cardiovasc Surg. 2004;127:264–6.CrossRefPubMed
6.
Zurück zum Zitat Toda K, Fujita T, Domae K, Shimahara Y, Kobayashi J, Nakatani T. Late aortic insufficiency related to poor prognosis during left ventricular assist device support. Ann Thorac Surg. 2011;92:929–34.CrossRefPubMed Toda K, Fujita T, Domae K, Shimahara Y, Kobayashi J, Nakatani T. Late aortic insufficiency related to poor prognosis during left ventricular assist device support. Ann Thorac Surg. 2011;92:929–34.CrossRefPubMed
Metadaten
Titel
A modified Park's stitch to correct aortic insufficiency for bioprosthetic valve at time of left ventricular assist device implant: a case report
verfasst von
Toshinobu Kazui
Nicole Sydow
Mark Friedman
Samuel Kim
Scott Lick
Zain Khalpey
Publikationsdatum
01.12.2016
Verlag
BioMed Central
Erschienen in
Journal of Cardiothoracic Surgery / Ausgabe 1/2016
Elektronische ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-016-0555-3

Weitere Artikel der Ausgabe 1/2016

Journal of Cardiothoracic Surgery 1/2016 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.