Abstract

Many research works have attempted to introduce passive RFID technology into medical systems to reduce medical errors. However, most of these proposed works focused on identifying patients and objects. If an RFID based medical system is only good for identifying patients and medical objects but not capable of halting any medical process immediately, then it is not possible to prevent medical errors from happening. Our research focuses on a mechanism to detect and to avoid medical harm before it occurs to patients. In this paper, we propose to incorporate multiple-constraints into the authorization scheme and used this scheme as a basis for implementing a medical management system avoiding medical errors to assist medical staff. Specifically, our scheme ensures that a medical operation is if and only if enabled when the constraints are being satisfied that an “identified patient” is being treated by a “certified medical staff member” within an “authorized area”. In practical environments, our authorization scheme can be applied to various healthcare applications, and we develop a prototype system and test it in three applications: X-ray control, specimen collection, and blood transfusion management. The experimental results show that the system can be used to enable X-ray when the X-ray is in authorized location and operated by authorized operator. For the specimen collection and blood transfusion, the logs showing which medical staff has done specimen or blood transfusion on which patient at authorized location are correctly recorded into Hospital Information System (HIS). The locating process can be performed within 10 to 20 seconds, and the locating error is less than 2 meters.
Literatur
1.
Zurück zum Zitat Kopec, D., Kabir, M. H., Reinharth, D., Rothschild, O., Castiglione, J.A., Human errors in medical practice: Systematic classification and reduction with automated information systems. J. Med. Syst. 27(4):297–313, 2003. doi:10.1023/A:1023796918654.CrossRefPubMed Kopec, D., Kabir, M. H., Reinharth, D., Rothschild, O., Castiglione, J.A., Human errors in medical practice: Systematic classification and reduction with automated information systems. J. Med. Syst. 27(4):297–313, 2003. doi:10.​1023/​A:​1023796918654.CrossRefPubMed
5.
Zurück zum Zitat Yang, A., Wrong-patient medication errors: an analysis of event reports in pennsylvania and strategies for prevention. Pa. Patient. Saf. Advis. 10(2):41–49, 2013. Yang, A., Wrong-patient medication errors: an analysis of event reports in pennsylvania and strategies for prevention. Pa. Patient. Saf. Advis. 10(2):41–49, 2013.
6.
Zurück zum Zitat Bates, D. W., Leape, L. L., Cullen, D. J., Laird, N., Petersen, L. A., Teich, J. M., Burdick, E., Hickey, M., Kleefield, S., Shea, B., Vander Vliet, M., Seger, D. L., Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. JAMA, J. Am. Med. Assoc. 208(15): 1311–1316, 1998. doi:10.1001/jama.280.15.1311.CrossRef Bates, D. W., Leape, L. L., Cullen, D. J., Laird, N., Petersen, L. A., Teich, J. M., Burdick, E., Hickey, M., Kleefield, S., Shea, B., Vander Vliet, M., Seger, D. L., Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. JAMA, J. Am. Med. Assoc. 208(15): 1311–1316, 1998. doi:10.​1001/​jama.​280.​15.​1311.CrossRef
7.
Zurück zum Zitat Charles, K., Cannon, M., Hall, R., Coustasse, A., Can utilizing a computerized provider order entry (CPOE) system prevent hospital medical errors and adverse drug events? Perspect. Health. Inf. Manag. 11:1–16, 2014. Charles, K., Cannon, M., Hall, R., Coustasse, A., Can utilizing a computerized provider order entry (CPOE) system prevent hospital medical errors and adverse drug events? Perspect. Health. Inf. Manag. 11:1–16, 2014.
8.
Zurück zum Zitat Rodriguez-Gonzalez, C. G., Herranz-Alonso, A., Martin-Barbero, M. L., Duran-Garcia, E., Durango-Limarquez, M. I., Hernändez-Sampelayo, P., Sanjurjo-Saez, M., Prevalence of medication administration errors in two medical units with automated prescription and dispensing. J. Am. Med. Inform. Assoc. 19(1):72–78, 2012. doi:10.1136/amiajnl-2011-000332.CrossRefPubMedPubMedCentral Rodriguez-Gonzalez, C. G., Herranz-Alonso, A., Martin-Barbero, M. L., Duran-Garcia, E., Durango-Limarquez, M. I., Hernändez-Sampelayo, P., Sanjurjo-Saez, M., Prevalence of medication administration errors in two medical units with automated prescription and dispensing. J. Am. Med. Inform. Assoc. 19(1):72–78, 2012. doi:10.​1136/​amiajnl-2011-000332.CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Escobar-Rodríguez, T., Monge-Lozano, P., Romero-Alonso, M. M., Bolívar-Raya, M. A., Deploying information technology and continuous control monitoring systems in hospitals to prevent medication errors. HIM J. 41(1):17–25 , 2012.PubMed Escobar-Rodríguez, T., Monge-Lozano, P., Romero-Alonso, M. M., Bolívar-Raya, M. A., Deploying information technology and continuous control monitoring systems in hospitals to prevent medication errors. HIM J. 41(1):17–25 , 2012.PubMed
11.
12.
Zurück zum Zitat Lahtela, A., Hassinen, M., Jylha, V., RFID and NFC in healthcare: Safety of hospitals medication care. In: Proceedings of the Second International Conference on Pervasive Computing Technologies for Healthcare, 2008. PervasiveHealth. doi:10.1109/PCTHEALTH.2008.4571079, Vol. 2008, pp. 241–244 (2008 ) Lahtela, A., Hassinen, M., Jylha, V., RFID and NFC in healthcare: Safety of hospitals medication care. In: Proceedings of the Second International Conference on Pervasive Computing Technologies for Healthcare, 2008. PervasiveHealth. doi:10.​1109/​PCTHEALTH.​2008.​4571079, Vol. 2008, pp. 241–244 (2008 )
13.
Zurück zum Zitat Chen, P. J., Chen, Y. F., Chai, S. K., Huang, Y. F., Implementation of an RFID-based management system for operation room. In: Proceedings of the 2009 International Conference on Machine Learning and Cybernetics. doi:10.1109/ICMLC.2009.5212613, Vol. 5, pp. 2933–2938 (2009) Chen, P. J., Chen, Y. F., Chai, S. K., Huang, Y. F., Implementation of an RFID-based management system for operation room. In: Proceedings of the 2009 International Conference on Machine Learning and Cybernetics. doi:10.​1109/​ICMLC.​2009.​5212613, Vol. 5, pp. 2933–2938 (2009)
14.
Zurück zum Zitat Frisch, P., Miodownik, S., Booth, P., Carragee, P., Dowling, M., Patient Centric Identification and Association. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2009. EMBC. doi:10.1109/IEMBS.2009.5333558, Vol. 2009, pp. 1722–1725 (2009) Frisch, P., Miodownik, S., Booth, P., Carragee, P., Dowling, M., Patient Centric Identification and Association. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2009. EMBC. doi:10.​1109/​IEMBS.​2009.​5333558, Vol. 2009, pp. 1722–1725 (2009)
19.
Zurück zum Zitat Lin, C. C., Lin, P. Y., Lu, P. K., Hsieh, G. Y., Lee, W. L., Lee, R. G., A healthcare integration system for disease assessment and safety monitoring of dementia patients. IEEE Trans. Inform. Technol. Biomed. 12(5):579–586, 2008. doi:10.1109/TITB.2008.917914.CrossRef Lin, C. C., Lin, P. Y., Lu, P. K., Hsieh, G. Y., Lee, W. L., Lee, R. G., A healthcare integration system for disease assessment and safety monitoring of dementia patients. IEEE Trans. Inform. Technol. Biomed. 12(5):579–586, 2008. doi:10.​1109/​TITB.​2008.​917914.CrossRef
22.
Zurück zum Zitat Guédon, A. C., Wauben, L. S., De Korne, D. F., Overvelde, M., Dankelman, J., van Den Dobbelsteen, J. J., A RFID specific participatory design approach to support design and implementation of Real-Time location systems in the operating room. J. Med. Syst. 39(1):168, 2015. doi:10.1007/s10916-014-0168-0.CrossRefPubMed Guédon, A. C., Wauben, L. S., De Korne, D. F., Overvelde, M., Dankelman, J., van Den Dobbelsteen, J. J., A RFID specific participatory design approach to support design and implementation of Real-Time location systems in the operating room. J. Med. Syst. 39(1):168, 2015. doi:10.​1007/​s10916-014-0168-0.CrossRefPubMed
23.
Zurück zum Zitat Hsu, J. M., Chiang, T. C., Yu, Y. C., Teng, W. G., Hou, T. W., A new energy efficient and reliable MedRadio scheme based on cooperative communication for implanted medical devices. Int. J. Distrib. Sens. N, 2015, 2015. doi:10.1155/2015/239597. Hsu, J. M., Chiang, T. C., Yu, Y. C., Teng, W. G., Hou, T. W., A new energy efficient and reliable MedRadio scheme based on cooperative communication for implanted medical devices. Int. J. Distrib. Sens. N, 2015, 2015. doi:10.​1155/​2015/​239597.
28.
Zurück zum Zitat Hanada, E., Antoku, Y., Tani, S., Kimura, M., Hasegawa, A., Urano, S., Ohe, K., Yamaki, M., Nose, Y., Electromagnetic interference on medical equipment by Low-Power mobile telecommunication systems. IEEE Trans. Electromagn. Compat. 42(4):470–476, 2000. doi:10.1109/15.902316.CrossRef Hanada, E., Antoku, Y., Tani, S., Kimura, M., Hasegawa, A., Urano, S., Ohe, K., Yamaki, M., Nose, Y., Electromagnetic interference on medical equipment by Low-Power mobile telecommunication systems. IEEE Trans. Electromagn. Compat. 42(4):470–476, 2000. doi:10.​1109/​15.​902316.CrossRef
30.
Zurück zum Zitat van Der Togt, R., van Lieshout, E. J., Hensbroek, R., Beinat, E., Binnekade, J. M., Bakker, P. J., Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment. JAMA, J. Am. Med. Assoc. 299(24):2884–2890, 2008. doi:10.1001/jama.299.24.2884.CrossRef van Der Togt, R., van Lieshout, E. J., Hensbroek, R., Beinat, E., Binnekade, J. M., Bakker, P. J., Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment. JAMA, J. Am. Med. Assoc. 299(24):2884–2890, 2008. doi:10.​1001/​jama.​299.​24.​2884.CrossRef
32.
Zurück zum Zitat Bala, R., and Kumar, N., An efficient session initiation protocol for secure communication in vehicular ad hoc networks. Emerging Research in Computing, Information, Communication and Applications 2015(1):325–334, 2015. doi:10.1007/978-81-322-2550-8_32.CrossRef Bala, R., and Kumar, N., An efficient session initiation protocol for secure communication in vehicular ad hoc networks. Emerging Research in Computing, Information, Communication and Applications 2015(1):325–334, 2015. doi:10.​1007/​978-81-322-2550-8_​32.CrossRef
33.
34.
Zurück zum Zitat Guo, P., Wang, J., Geng, X. U., Kim, C. S., Kim, J.-U., A variable Threshold-Value authentication architecture for wireless mesh networks. J. Internet. Technol. 15(6):929–936, 2014. Guo, P., Wang, J., Geng, X. U., Kim, C. S., Kim, J.-U., A variable Threshold-Value authentication architecture for wireless mesh networks. J. Internet. Technol. 15(6):929–936, 2014.
Metadaten
Titel
A Multi-Constraint Scheme with Authorized Mechanism for the Patient Safety
verfasst von
Jen-Ming Hsu
Yao-Chang Yu
Ting-Wei Hou
Wei-Guang Teng
Tzu-Chiang Chiang
Ming-Chang Yang
Publikationsdatum
01.05.2016
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 5/2016
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-016-0479-4

Weitere Artikel der Ausgabe 5/2016

Journal of Medical Systems 5/2016 Zur Ausgabe