Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 3/2011

01.09.2011

A multi-purpose spiral high-density mapping catheter: initial clinical experience in complex atrial arrhythmias

verfasst von: David Gareth Jones, James W. McCready, Riyaz A. Kaba, Syed Y. Ahsan, Jonathan C. Lyne, Jack Wang, Oliver R. Segal, Vias Markides, Pier D. Lambiase, Tom Wong, Anthony W. C. Chow

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

Purpose

There is an increasing need for catheter ablation procedures to treat complex atrial tachycardias (AT) and atrial fibrillation (AF), often requiring detailed endocardial mapping. The sequential point-to-point contact mapping of complex arrhythmias is time-consuming and may not always be feasible. We assessed the utility of a novel spiral duo-decapolar high-density (HD) mapping catheter to delineate complex arrhythmia substrates for ablation.

Methods

The patients underwent HD mapping using a spiral catheter (AFocusII) and the EnSite NavX system, during catheter ablation procedures, to treat atrial arrhythmias.

Results

In 26 patients, a total of 32 atrial arrhythmias were mapped and ablated, comprising of five focal AT, eight macroreentrant AT, 11 persistent AF and eight paroxysmal AF. The HD catheter was used to acquire endocardial surface geometries in all cases and to map the pulmonary veins in patients undergoing AF ablation. In persistent AF, HD catheter mapping permitted the creation of highly detailed complex fractionated electrogram maps (left atrium 449 ± 128 points in 7.2 ± 2.6 min; right atrium 411 ± 113 points in 6.7 ± 1.6 min). In AT, activation mapping was performed with the acquisition of 305 ± 158 timing points in 7.3 ± 2.6 min, guiding successful ablation in all cases. During the follow-up of 7.0 ± 2.6 months, all AT patients remained free of significant arrhythmia.

Conclusions

High-density contact mapping with a novel spiral multipolar catheter allows rapid assessment of focal and macroreentrant AT, and complex fractionated electrical activity in the atria. It has further multi-functional capabilities as a pulmonary vein mapping catheter and for accurate geometry creation when used with a 3D mapping system.
Literatur
1.
Zurück zum Zitat Packer, D. L. (2005). Three-dimensional mapping in interventional electrophysiology: Techniques and technology. Journal of Cardiovascular Electrophysiology, 16(10), 1110–1116.PubMedCrossRef Packer, D. L. (2005). Three-dimensional mapping in interventional electrophysiology: Techniques and technology. Journal of Cardiovascular Electrophysiology, 16(10), 1110–1116.PubMedCrossRef
2.
Zurück zum Zitat de Groot, N. M., Schalij, M. J., Zeppenfeld, K., Blom, N. A., Van der Velde, E. T., & Van der Wall, E. E. (2003). Voltage and activation mapping: How the recording technique affects the outcome of catheter ablation procedures in patients with congenital heart disease. Circulation, 108(17), 2099–2106.PubMedCrossRef de Groot, N. M., Schalij, M. J., Zeppenfeld, K., Blom, N. A., Van der Velde, E. T., & Van der Wall, E. E. (2003). Voltage and activation mapping: How the recording technique affects the outcome of catheter ablation procedures in patients with congenital heart disease. Circulation, 108(17), 2099–2106.PubMedCrossRef
3.
Zurück zum Zitat Abrams, D. J., Earley, M. J., Sporton, S. C., Kistler, P. M., Gatzoulis, M. A., Mullen, M. J., et al. (2007). Comparison of noncontact and electroanatomic mapping to identify scar and arrhythmia late after the fontan procedure. Circulation, 115(13), 1738–1746.PubMedCrossRef Abrams, D. J., Earley, M. J., Sporton, S. C., Kistler, P. M., Gatzoulis, M. A., Mullen, M. J., et al. (2007). Comparison of noncontact and electroanatomic mapping to identify scar and arrhythmia late after the fontan procedure. Circulation, 115(13), 1738–1746.PubMedCrossRef
4.
Zurück zum Zitat Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., et al. (2004). A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate. Journal of the American College of Cardiology, 43(11), 2044–2053.PubMedCrossRef Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., et al. (2004). A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate. Journal of the American College of Cardiology, 43(11), 2044–2053.PubMedCrossRef
5.
Zurück zum Zitat Lin, Y. J., Tai, C. T., Chang, S. L., Lo, L. W., Tuan, T. C., Wongcharoen, W., et al. (2009). Efficacy of additional ablation of complex fractionated atrial electrograms for catheter ablation of nonparoxysmal atrial fibrillation. Journal of Cardiovascular Electrophysiology, 20(6), 607–615.PubMedCrossRef Lin, Y. J., Tai, C. T., Chang, S. L., Lo, L. W., Tuan, T. C., Wongcharoen, W., et al. (2009). Efficacy of additional ablation of complex fractionated atrial electrograms for catheter ablation of nonparoxysmal atrial fibrillation. Journal of Cardiovascular Electrophysiology, 20(6), 607–615.PubMedCrossRef
6.
Zurück zum Zitat Oral, H., Chugh, A., Yoshida, K., Sarrazin, J. F., Kuhne, M., Crawford, T., et al. (2009). A randomized assessment of the incremental role of ablation of complex fractionated atrial electrograms after antral pulmonary vein isolation for long-lasting persistent atrial fibrillation. Journal of the American College of Cardiology, 53(9), 782–789.PubMedCrossRef Oral, H., Chugh, A., Yoshida, K., Sarrazin, J. F., Kuhne, M., Crawford, T., et al. (2009). A randomized assessment of the incremental role of ablation of complex fractionated atrial electrograms after antral pulmonary vein isolation for long-lasting persistent atrial fibrillation. Journal of the American College of Cardiology, 53(9), 782–789.PubMedCrossRef
7.
Zurück zum Zitat Stiles, M. K., Brooks, A. G., John, B., Wilson, L., Kuklik, P., Dimitri, H., et al. (2008). The effect of electrogram duration on quantification of complex fractionated atrial electrograms and dominant frequency. Journal of Cardiovascular Electrophysiology, 19(3), 252–258.PubMedCrossRef Stiles, M. K., Brooks, A. G., John, B., Wilson, L., Kuklik, P., Dimitri, H., et al. (2008). The effect of electrogram duration on quantification of complex fractionated atrial electrograms and dominant frequency. Journal of Cardiovascular Electrophysiology, 19(3), 252–258.PubMedCrossRef
8.
Zurück zum Zitat Verma, A., Wulffhart, Z., Beardsall, M., Whaley, B., Hill, C., & Khaykin, Y. (2008). Spatial and temporal stability of complex fractionated electrograms in patients with persistent atrial fibrillation over longer time periods: Relationship to local electrogram cycle length. Heart Rhythm, 5(8), 1127–1133.PubMedCrossRef Verma, A., Wulffhart, Z., Beardsall, M., Whaley, B., Hill, C., & Khaykin, Y. (2008). Spatial and temporal stability of complex fractionated electrograms in patients with persistent atrial fibrillation over longer time periods: Relationship to local electrogram cycle length. Heart Rhythm, 5(8), 1127–1133.PubMedCrossRef
9.
Zurück zum Zitat Patel, A. M., d’Avila, A., Neuzil, P., Kim, M. S. J., Mela, T., Singh, J. P., et al. (2008). Atrial tachycardia after ablation of persistent atrial fibrillation: Identification of the critical isthmus with a combination of multielectrode activation mapping and targeted entrainment mapping. Circ Arrhythmia Electrophysiol, 1(1), 14–22.CrossRef Patel, A. M., d’Avila, A., Neuzil, P., Kim, M. S. J., Mela, T., Singh, J. P., et al. (2008). Atrial tachycardia after ablation of persistent atrial fibrillation: Identification of the critical isthmus with a combination of multielectrode activation mapping and targeted entrainment mapping. Circ Arrhythmia Electrophysiol, 1(1), 14–22.CrossRef
10.
Zurück zum Zitat Aizer, A., Holmes, D. S., Garlitski, A. C., Bernstein, N. E., Smyth-Melsky, J. M., Ferrick, A. M., et al. (2008). Standardization and validation of an automated algorithm to identify fractionation as a guide for atrial fibrillation ablation. Heart Rhythm, 5(8), 1134–1141.PubMedCrossRef Aizer, A., Holmes, D. S., Garlitski, A. C., Bernstein, N. E., Smyth-Melsky, J. M., Ferrick, A. M., et al. (2008). Standardization and validation of an automated algorithm to identify fractionation as a guide for atrial fibrillation ablation. Heart Rhythm, 5(8), 1134–1141.PubMedCrossRef
11.
Zurück zum Zitat Estner, H. L., Deisenhofer, I., Luik, A., Ndrepepa, G., von Bary, C., Zrenner, B., et al. (2006). Electrical isolation of pulmonary veins in patients with atrial fibrillation: Reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (navx). Europace, 8(8), 583–587.PubMedCrossRef Estner, H. L., Deisenhofer, I., Luik, A., Ndrepepa, G., von Bary, C., Zrenner, B., et al. (2006). Electrical isolation of pulmonary veins in patients with atrial fibrillation: Reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (navx). Europace, 8(8), 583–587.PubMedCrossRef
12.
Zurück zum Zitat Lin, Y. J., Tai, C. T., Kao, T., Chang, S. L., Wongcharoen, W., Lo, L. W., et al. (2008). Consistency of complex fractionated atrial electrograms during atrial fibrillation. Heart Rhythm, 5(3), 406–412.PubMedCrossRef Lin, Y. J., Tai, C. T., Kao, T., Chang, S. L., Wongcharoen, W., Lo, L. W., et al. (2008). Consistency of complex fractionated atrial electrograms during atrial fibrillation. Heart Rhythm, 5(3), 406–412.PubMedCrossRef
13.
Zurück zum Zitat Verma, A., Novak, P., Macle, L., Whaley, B., Beardsall, M., Wulffhart, Z., et al. (2008). A prospective, multicenter evaluation of ablating complex fractionated electrograms (cfes) during atrial fibrillation (af) identified by an automated mapping algorithm: Acute effects on af and efficacy as an adjuvant strategy. Heart Rhythm, 5(2), 198–205.PubMedCrossRef Verma, A., Novak, P., Macle, L., Whaley, B., Beardsall, M., Wulffhart, Z., et al. (2008). A prospective, multicenter evaluation of ablating complex fractionated electrograms (cfes) during atrial fibrillation (af) identified by an automated mapping algorithm: Acute effects on af and efficacy as an adjuvant strategy. Heart Rhythm, 5(2), 198–205.PubMedCrossRef
14.
Zurück zum Zitat Nakagawa, H., Shah, N., Matsudaira, K., Overholt, E., Chandrasekaran, K., Beckman, K. J., et al. (2001). Characterization of reentrant circuit in macroreentrant right atrial tachycardia after surgical repair of congenital heart disease: Isolated channels between scars allow “focal” ablation. Circulation, 103(5), 699–709.PubMed Nakagawa, H., Shah, N., Matsudaira, K., Overholt, E., Chandrasekaran, K., Beckman, K. J., et al. (2001). Characterization of reentrant circuit in macroreentrant right atrial tachycardia after surgical repair of congenital heart disease: Isolated channels between scars allow “focal” ablation. Circulation, 103(5), 699–709.PubMed
15.
Zurück zum Zitat Rostock, T., Rotter, M., Sanders, P., Takahashi, Y., Jais, P., Hocini, M., et al. (2006). High-density activation mapping of fractionated electrograms in the atria of patients with paroxysmal atrial fibrillation. Heart Rhythm, 3(1), 27–34.PubMedCrossRef Rostock, T., Rotter, M., Sanders, P., Takahashi, Y., Jais, P., Hocini, M., et al. (2006). High-density activation mapping of fractionated electrograms in the atria of patients with paroxysmal atrial fibrillation. Heart Rhythm, 3(1), 27–34.PubMedCrossRef
16.
Zurück zum Zitat Oketani, N., Lockwood, E., & Nademanee, K. (2008). Incidence and mode of af termination during substrate ablation of af guided solely by complex fractionated atrial electrograms mapping. Circulation, 118(18_MeetingAbstracts), S_925-a-. Oketani, N., Lockwood, E., & Nademanee, K. (2008). Incidence and mode of af termination during substrate ablation of af guided solely by complex fractionated atrial electrograms mapping. Circulation, 118(18_MeetingAbstracts), S_925-a-.
17.
Zurück zum Zitat Haissaguerre, M., Sanders, P., Hocini, M., Takahashi, Y., Rotter, M., Sacher, F., et al. (2005). Catheter ablation of long-lasting persistent atrial fibrillation: Critical structures for termination. Journal of Cardiovascular Electrophysiology, 16(11), 1125–1137.PubMedCrossRef Haissaguerre, M., Sanders, P., Hocini, M., Takahashi, Y., Rotter, M., Sacher, F., et al. (2005). Catheter ablation of long-lasting persistent atrial fibrillation: Critical structures for termination. Journal of Cardiovascular Electrophysiology, 16(11), 1125–1137.PubMedCrossRef
18.
Zurück zum Zitat Takahashi, Y., O’Neill, M. D., Hocini, M., Dubois, R., Matsuo, S., Knecht, S., et al. (2008). Characterization of electrograms associated with termination of chronic atrial fibrillation by catheter ablation. Journal of the American College of Cardiology, 51(10), 1003–1010.PubMedCrossRef Takahashi, Y., O’Neill, M. D., Hocini, M., Dubois, R., Matsuo, S., Knecht, S., et al. (2008). Characterization of electrograms associated with termination of chronic atrial fibrillation by catheter ablation. Journal of the American College of Cardiology, 51(10), 1003–1010.PubMedCrossRef
19.
Zurück zum Zitat Verma, A., Montovan, R., Macle, L., De Martino, G., Chen, J., Morillo, C., et al. (2009). Substrate vs. Trigger ablation for reduction of atrial fibrillation (star-af): An international, multicenter, randomized trial. Presented at Late-Breaking Clinical Trials I, Heart Rhythm Society Annual Scientific Sessions. Verma, A., Montovan, R., Macle, L., De Martino, G., Chen, J., Morillo, C., et al. (2009). Substrate vs. Trigger ablation for reduction of atrial fibrillation (star-af): An international, multicenter, randomized trial. Presented at Late-Breaking Clinical Trials I, Heart Rhythm Society Annual Scientific Sessions.
20.
Zurück zum Zitat Porter, M., Spear, W., Akar, J. G., Helms, R., Brysiewicz, N., Santucci, P., et al. (2008). Prospective study of atrial fibrillation termination during ablation guided by automated detection of fractionated electrograms. Journal of Cardiovascular Electrophysiology, 19(6), 613–620.PubMedCrossRef Porter, M., Spear, W., Akar, J. G., Helms, R., Brysiewicz, N., Santucci, P., et al. (2008). Prospective study of atrial fibrillation termination during ablation guided by automated detection of fractionated electrograms. Journal of Cardiovascular Electrophysiology, 19(6), 613–620.PubMedCrossRef
21.
Zurück zum Zitat Wu, J., Estner, H., Luik, A., Ucer, E., Reents, T., Pflaumer, A., et al. (2008). Automatic 3D mapping of complex fractionated atrial electrograms (cfae) in patients with paroxysmal and persistent atrial fibrillation. Journal of Cardiovascular Electrophysiology, 19(9), 897–903.PubMedCrossRef Wu, J., Estner, H., Luik, A., Ucer, E., Reents, T., Pflaumer, A., et al. (2008). Automatic 3D mapping of complex fractionated atrial electrograms (cfae) in patients with paroxysmal and persistent atrial fibrillation. Journal of Cardiovascular Electrophysiology, 19(9), 897–903.PubMedCrossRef
22.
Zurück zum Zitat Roux, J. F., Gojraty, S., Bala, R., Liu, C. F., Hutchinson, M. D., Dixit, S., et al. (2008). Complex fractionated electrogram distribution and temporal stability in patients undergoing atrial fibrillation ablation. Journal of Cardiovascular Electrophysiology, 19(8), 815–820.PubMedCrossRef Roux, J. F., Gojraty, S., Bala, R., Liu, C. F., Hutchinson, M. D., Dixit, S., et al. (2008). Complex fractionated electrogram distribution and temporal stability in patients undergoing atrial fibrillation ablation. Journal of Cardiovascular Electrophysiology, 19(8), 815–820.PubMedCrossRef
23.
Zurück zum Zitat Meissner, A., van Bracht, M., Schrage, M. O., Christ, M., Trappe, H. J., Maagh, P., et al. (2009). Segmental pulmonary vein isolation in atrial fibrillation: New insights from the high density mesh mapper technique in an electrophysiologically guided approach. Journal of Interventional Cardiac Electrophysiology, 25(3), 183–192.PubMedCrossRef Meissner, A., van Bracht, M., Schrage, M. O., Christ, M., Trappe, H. J., Maagh, P., et al. (2009). Segmental pulmonary vein isolation in atrial fibrillation: New insights from the high density mesh mapper technique in an electrophysiologically guided approach. Journal of Interventional Cardiac Electrophysiology, 25(3), 183–192.PubMedCrossRef
24.
Zurück zum Zitat Neumann, T., Kuniss, M., Erkapic, D., Zaltsberg, S., Berkowitsch, A., Pajitnev, D., et al. (2010). Acute and long-term results of PVI at antrum using a novel high-density mapping catheter without help of 3D electro-anatomic mapping in patients with paroxysmal and chronic atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 27(2), 101–108.PubMedCrossRef Neumann, T., Kuniss, M., Erkapic, D., Zaltsberg, S., Berkowitsch, A., Pajitnev, D., et al. (2010). Acute and long-term results of PVI at antrum using a novel high-density mapping catheter without help of 3D electro-anatomic mapping in patients with paroxysmal and chronic atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 27(2), 101–108.PubMedCrossRef
25.
Zurück zum Zitat Maagh, P., van Bracht, M., Butz, T., Trappe, H. J., & Meissner, A. (2010). Eighteen months follow-up of the clinical efficacy of the high density mesh ablator (HDMA) in patients with atrial fibrillation after pulmonary vein isolation. Journal of Interventional Cardiac Electrophysiology, 29(1), 43–52.PubMedCrossRef Maagh, P., van Bracht, M., Butz, T., Trappe, H. J., & Meissner, A. (2010). Eighteen months follow-up of the clinical efficacy of the high density mesh ablator (HDMA) in patients with atrial fibrillation after pulmonary vein isolation. Journal of Interventional Cardiac Electrophysiology, 29(1), 43–52.PubMedCrossRef
26.
Zurück zum Zitat Mansour, M., Forleo, G. B., Pappalardo, A., Heist, E. K., Avella, A., Laurenzi, F., et al. (2008). Initial experience with the mesh catheter for pulmonary vein isolation in patients with paroxysmal atrial fibrillation. Heart Rhythm, 5(11), 1510–1516.PubMedCrossRef Mansour, M., Forleo, G. B., Pappalardo, A., Heist, E. K., Avella, A., Laurenzi, F., et al. (2008). Initial experience with the mesh catheter for pulmonary vein isolation in patients with paroxysmal atrial fibrillation. Heart Rhythm, 5(11), 1510–1516.PubMedCrossRef
27.
Zurück zum Zitat Beinart, R., Perna, F., Danik, S., Barrett, C. D., Heist, E. K., Ruskin, J., et al. (2010). Initial experience with a multielectrode catheter equipped with the single-axis sensor technology for high-density electroanatomical mapping in a swine model. J Cardiovasc Electrophysiol, 21, 1403–1407.PubMedCrossRef Beinart, R., Perna, F., Danik, S., Barrett, C. D., Heist, E. K., Ruskin, J., et al. (2010). Initial experience with a multielectrode catheter equipped with the single-axis sensor technology for high-density electroanatomical mapping in a swine model. J Cardiovasc Electrophysiol, 21, 1403–1407.PubMedCrossRef
Metadaten
Titel
A multi-purpose spiral high-density mapping catheter: initial clinical experience in complex atrial arrhythmias
verfasst von
David Gareth Jones
James W. McCready
Riyaz A. Kaba
Syed Y. Ahsan
Jonathan C. Lyne
Jack Wang
Oliver R. Segal
Vias Markides
Pier D. Lambiase
Tom Wong
Anthony W. C. Chow
Publikationsdatum
01.09.2011
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2011
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-011-9574-0

Weitere Artikel der Ausgabe 3/2011

Journal of Interventional Cardiac Electrophysiology 3/2011 Zur Ausgabe

Die „Zehn Gebote“ des Endokarditis-Managements

30.04.2024 Endokarditis Leitlinie kompakt

Worauf kommt es beim Management von Personen mit infektiöser Endokarditis an? Eine Kardiologin und ein Kardiologe fassen die zehn wichtigsten Punkte der neuen ESC-Leitlinie zusammen.

Strenge Blutdruckeinstellung lohnt auch im Alter noch

30.04.2024 Arterielle Hypertonie Nachrichten

Ältere Frauen, die von chronischen Erkrankungen weitgehend verschont sind, haben offenbar die besten Chancen, ihren 90. Geburtstag zu erleben, wenn ihr systolischer Blutdruck < 130 mmHg liegt. Das scheint selbst für 80-Jährige noch zu gelten.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Dihydropyridin-Kalziumantagonisten können auf die Nieren gehen

30.04.2024 Hypertonie Nachrichten

Im Vergleich zu anderen Blutdrucksenkern sind Kalziumantagonisten vom Diyhdropyridin-Typ mit einem erhöhten Risiko für eine Mikroalbuminurie und in Abwesenheit eines RAS-Blockers auch für ein terminales Nierenversagen verbunden.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.