Skip to main content
Erschienen in: BMC Gastroenterology 1/2019

Open Access 01.12.2019 | Research article

A novel technique for repositioning a nasobiliary catheter from the mouth to nostril in endoscopic retrograde cholangiopancreatography

verfasst von: Seong Ji Choi, Jae Min Lee, Hyuk Soon Choi, Eun Sun Kim, Bora Keum, Yeon Seok Seo, Yoon Tae Jeen, Hong Sik Lee, Hoon Jai Chun, Soon Ho Um, Chang Duck Kim, Chi Hyuk Oh

Erschienen in: BMC Gastroenterology | Ausgabe 1/2019

Abstract

Background

Endoscopic nasobiliary drainage (ENBD) is widely used for biliary decompression in patients with biliary disease. However, it is difficult to reposition a nasobiliary catheter from the mouth to nostril. We developed a new device, which has a curved flexible loop and bar-handle, for repositioning of ENBD catheter. The aim of this study was to evaluate the usefulness of the new loop-device for facilitating the repositioning of an ENBD catheter from the mouth to nostril.

Methods

Between January 2015 and December 2017, a comparative observational study was performed to evaluate the time taken for repositioning a nasobiliary catheter during endoscopic retrograde cholangiopancreatography (ERCP) and compare the results of ENBD procedure between the new loop-device and conventional techniques. In the subgroup analysis, we evaluated the occurrence of oral cavity injury and the time taken to transfer ENBD catheter from the mouth to nostril.

Results

In all, 145 ENBD procedures were performed using these two techniques. The procedure time was significantly shorter in the new technique group than in the conventional group. (44 s vs. 194 s, p < 0.001). The total success rate of new device technique was 97.3%. No complication, including oral cavity injury, was observed.

Conclusions

The technique using our new loop-device was useful for repositioning a nasobiliary catheter from the mouth to nostril in ERCP. The new device does not require the removal of the mouthpiece before ENBD positioning, which can help perform the ENBD procedure rapidly and avoid the finger injury of endoscopists.
Hinweise

Supplementary information

Supplementary information accompanies this paper at https://​doi.​org/​10.​1186/​s12876-019-1148-0.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
ENBD
Endoscopic nasobiliary drainage
ERCP
Endoscopic retrograde cholangiopancreatography
SD
Standard deviation

Background

Endoscopic retrograde cholangiopancreatography (ERCP) is an important procedure for the treatment of biliary diseases. In patients with cholangitis or biliary obstruction, endoscopic nasobiliary drainage (ENBD) can be required for effective drainage of bile juice [1, 2]. ENBD shows a better effect for decreasing hyperbilirubinemia and has a lower risk of catheter obstruction than endoscopic retrograde biliary drainage [3]. Also, ENBD procedure is usually needed to obtain bile juice sample for cytological analysis or bacteriological culture.
For completing the ENBD after ERCP, a drainage catheter repositioning from the mouth to nostril has to be performed. The conventional technique involves inserting a nasal plastic tube, catching the tip of the tube in the mouth, pulling out the tip, connecting the ENBD catheter with the tube and completing the repositioning by extracting the catheter toward the nose. However, the conventional technique has several disadvantages. The mouthpiece had to be removed from the mouth in sedated patients before the ENBD repositioning. It may take a long time to wait for the patients to wake up. Moreover, the finger injury of the operator often occurs from biting by poorly cooperative patients. When using the forceps, there is a risk of oral cavity injury while grasping the tip of the plastic tube.
Prior investigators have suggested modified techniques to facilitate the ENBD repositioning [47]. In a previous study, Hamano et al. suggested a new technique by making a wire loop by crossing guidewire [5]. However, in practice, the crossed guide-wire frequently slips out of the hands and an appropriate loop size or shape has not been defined. Moreover, additional fluoroscopic or endoscopic observation was required for the prior techniques. Poor visualization of the oropharynx inhibits repositioning of the ENBD, especially in patients with a high Mallampati score. Therefore, the shape of the oropharynx should be considered to develop new techniques for the ENBD repositioning.
We have developed a new device composed of a curved wire-loop and bar-handle. In this study, we compared the outcomes between the conventional technique and our new technique using the device we developed for the ENBD repositioning.

Methods

Study design and patients

This is a comparative observational study using endoscopic data in patients who underwent ERCP at a tertiary medical center in Seoul, Korea between January 2015 and December 2017. We selected patients who underwent the ENBD procedure with the conventional catheter repositioning technique or the new technique using our device. The inclusion criteria were as follows: (1) age above 18 years, (2) patients who underwent the ENBD procedure with medical records of the procedure time, (3) no medical history of nasopharyngeal deformity, and (4) written informed consent. The conventional catheter repositioning technique was used from January 2015 to August 2016, and the new technique was used since September 2016 in our center. The patients who underwent ERCP from January 2015 to August 2016 were allocated to the conventional technique group, and those who underwent ERCP from September 2016 to December 2017 were allocated to the J-Loop technique group. Total of 160 patients were enrolled, 80 patients for each group, and 9 patients from conventional technique group and 6 patients from J-loop technique group, who were without sufficient medical data such as procedure time record or Mallampati score, were excluded.
This study was conducted in accordance with the Declaration of Helsinki and was approved by the institutional human research committee. The study was reviewed and approved by the Ethics Committee of Korea University Anam Hospital(2019AN0313). All patients signed a written informed consent before the procedure.

Procedures and device

The conventional technique for ENBD has the following steps: (1) the ENBD catheter located in the oral cavity with the scope is withdrawn from the mouth, (2) the mouth piece is removed and the mouth is opened using the operator’s fingers, (3) a plastic tube is inserted into the nasal cavity, (4) the tip of plastic tube is grasped using fingers or forceps in the oral cavity, (5) the plastic tube is pulled from the oval cavity and connected with the ENBD catheter, and (6) the plastic tube, connected with the ENBD catheter, is pulled toward the nose.
The new technique was performed by using the new device. The device set composed of a loop-shaped holder and a plastic tube with markings (Fig. 1, patent pending). The loop-shaped holder named as ‘J-Loop’ consisted of a curved loop head and a bar-shaped handle. The plastic tube has several markings for measuring the insertion depth. The new technique has the following steps: (1) the ENBD catheter located in oral cavity with the scope is withdrawn from the mouth, (2) the J-loop is inserted into the oral cavity, (3) the plastic tube is inserted into the into the nasal cavity up to markings, (4) the plastic tube, caught in the loop, is pulled, and (5) the plastic tube, connected with the ENBD catheter, is pulled toward the nose. Figure 2 and Additional file 1: Video S1 show each step of the new technique using J-Loop. The ENBD catheter and the J-loop can be visualized under fluoroscopy (Additional file 2: Figure S1).
Additional file 1: Video S1. Procedural video of nasobiliary catheter reposition using J-loop

Outcomes of procedures

The results of the conventional technique and the new technique using J-Loop were compared. The outcomes were ENBD catheter positioning time, success rate and side effects. The ENBD positioning time was defined as the time from ‘scope withdrawn from the mouth’ to ‘completion of fixation of ENBD catheter toward the nose.’ The shape of the oropharynx was scored by using the Mallampati score [7].

Statistical analysis

Normally distributed data were expressed as mean ± standard deviation (SD), and student t-test was used to compare the parameters. Not normally distributed data were expressed as median (range), and Mann-Whitney U test was used to compare the parameters. Chi-square test or Fisher’s exact test was used for compare the distribution of a categorical variable. P values < 0.05 were considered statistically significant. Data were analyzed using the Statistical Package for the Social Sciences version 24.0 (IBM Corp., Armonk, N.Y., USA).

Results

A total of 145 patients were included in this study. The baseline characteristics of the patients are shown in Table 1. The mean age was 65.7 ± 14.7 years, and 75 (52%) patients were men. The conventional technique and the new technique using J-Loop were performed in 71 and 74 patients, respectively, for the ENBD repositioning. Table 2 shows the outcomes of the two techniques for the ENBD repositioning in ERCP. The new technique using J-Loop showed significantly shorter procedure time for the ENBD repositioning than the conventional technique (44 s vs. 194 s, P < 0.001). The technical success of the new technique was achieved in 97.3% (72/74) of cases. Two patients who underwent the new technique experienced difficulty due to deep insertion of the J-loop into the throat, and were barely successful with conventional method. A high Mallampati score was related to difficult ENBD repositioning using the conventional technique. However, there was no significant difference in the repositioning time using J-Loop (Table 3). In the new technique group, there were no complications such as oral cavity injury, tooth damage, and pharynx bleeding, nor any unexpected event, such as an injury to the operator’s finger.
Table 1
Baseline characteristics of the enrolled patients underwent ERCP
 
All patients (n = 145)
Conventional technique group (n = 71)
J-Loop technique group (n = 74)
P-value
Age, years
65.7 ± 14.7
67.7 ± 13.4
63.9 ± 15.8
0.124
Male, n (%)
75 (51.7)
38 (53.5)
37 (50.0)
0.671
Indication for ERCP, n (%)
   
0.154
 Gallstone disease
88 (60.7)
46 (64.8)
42 (56.8)
 
 Malignant bile duct obstruction
23 (15.9)
13 (18.3)
10 (13.5)
 
 Benign bile duct stricture
25 (17.2)
11 (15.5)
14 (18.9)
 
 Bile leak
4 (2.8)
0 (0)
4 (5.4)
 
Others
5 (3.4)
1 (1.4)
4 (5.4)
 
Mallampati score, n (%)
   
0.686
 Class 1
82 (56.6)
42 (59.2)
40 (54.1)
 
 Class 2
33 (22.8)
15 (21.1)
18 (24.3)
 
 Class 3
18 (12.4)
7 (9.9)
11 (14.9)
 
 Class 4
12 (8.3)
7 (9.9)
5 (6.8)
 
ERCP endoscopic retrograde cholangiopancreatography
Table 2
Clinical outcomes of ENBD procedure
 
Conventional technique group
J-Loop technique group
P-value
Patients, n
71
74
 
ENBD repositioning time, s (range)
194.0 (88–544)
34.5 (19–150)
< 0.001
Technical success, n (%)
71 (100)
72 (97.3)
0.163
ENBD endoscopic nasobiliary drainage
s second
Table 3
Mallampati score and ENBD repositioning time
 
Low Mallampati score (1 or 2)
High Mallampati score (3 or 4)
P-value
Patients, n
115
28
 
ENBD repositioning time, s (range)
 Conventional technique
171.2 (88–264)
286.2 (205–544)
< 0.001
 J-Loop technique
42.9 (19–146)
49.9 (27–150)
0.482
ENBD endoscopic nasobiliary drainage
s second

Discussion

In this study, the new ENBD device, J-Loop, was easy, convenient, fast and safe for repositioning the ENBD catheter from the mouth to nostril. The outcomes showed that the new technique is more efficient than the conventional technique for the ENBD repositioning. The conventional technique took an average of 194 s for the ENBD repositioning, which was similar to the results from other studies [4, 5]. Using the new technique, the time required for the ENBD repositioning was reduced to 44 s (approximately 77%). As the steps of removing the mouthpiece and waiting for the patient to wake up to open their mouth was skipped, the overall procedure to complete ENBD was simplified.
In the conventional technique, operators had to insert a plastic tube into the nose and pull out its tip through the pharynx and oral cavity using a finger or forcep. However, it is difficult to catch the tip of a plastic tube especially in patients with a short neck or a small oral cavity. Poor visualization of the oral cavity is an obstacle to a successful ENBD repositioning. When using the conventional technique, the ENBD repositioning time was significantly longer in the higher Mallampati score patients than that in the lower Mallampati score patients.
However, the new technique does not require observing the oral cavity or catching the tip of a plastic tube. As the plastic tube can be dragged out while pulling out the J-loop, operators just have to push the J-loop into the mouth and plastic tube into the nostril up to a marking, and pull the J-loop out. Appropriate depths were marked on plastic tube. There was no significant difference related to the Mallampati scores of the group while using the new technique.
Another advantage of the new repositioning technique is that the ENBD repositioning with J-loop can be performed to the sedated patient immediately after removing the endoscope. As the operator does not need to touch the patient’s oral cavity, there is no risk of causing injury to the patient, such as a mucosal scratch or broken tooth. Moreover, as the entire procedure is completed in the sedated state, the patient does not feel any discomfort during the ENBD repositioning. Above all, the operator is able to avoid an unexpected injury or trauma to the finger and can be free from the fear of ENBD, either fear of failure or pain. This study was performed in patients who underwent ERCP under sedation, not under general anesthesia with endotracheal intubation. Therefore, further studies are needed to determine whether the J-Loop is also convenient for ERCP under general anesthesia.

Conclusions

In summary, the new technique is useful and effective for repositioning of the ENBD catheter from the mouth to nostril. The technique using the J-loop allows the operator to easily maneuver the ENBD procedure and helps avoid injury to both the operator and patients.

Supplementary information

Supplementary information accompanies this paper at https://​doi.​org/​10.​1186/​s12876-019-1148-0.

Acknowledgements

Not applicable.
Written informed consent was obtained from the patient for the publication of supplementary video. A copy of the written consent is available for review by the editors of this journal.
The study was reviewed and approved by the Ethics Committee of Korea University Anam Hospital.(K2019-1345-001) All study participants provided informed written consent prior to be enrolled in this observational study.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Lai EC, Mok FP, Tan ES, Lo CM, Fan ST, You KT, Wong J. Endoscopic biliary drainage for severe acute cholangitis. N Engl J Med. 1992;326(24):1582–6.CrossRef Lai EC, Mok FP, Tan ES, Lo CM, Fan ST, You KT, Wong J. Endoscopic biliary drainage for severe acute cholangitis. N Engl J Med. 1992;326(24):1582–6.CrossRef
2.
Zurück zum Zitat Kumar R, Sharma BC, Singh J, Sarin SK. Endoscopic biliary drainage for severe acute cholangitis in biliary obstruction as a result of malignant and benign diseases. J Gastroenterol Hepatol. 2004;19(9):994–7.CrossRef Kumar R, Sharma BC, Singh J, Sarin SK. Endoscopic biliary drainage for severe acute cholangitis in biliary obstruction as a result of malignant and benign diseases. J Gastroenterol Hepatol. 2004;19(9):994–7.CrossRef
3.
Zurück zum Zitat Zhang RL, Cheng L, Cai XB, Zhao H, Zhu F, Wan XJ. Comparison of the safety and effectiveness of endoscopic biliary decompression by nasobiliary catheter and plastic stent placement in acute obstructive cholangitis. Swiss Med Wkly. 2013;143:w13823.PubMed Zhang RL, Cheng L, Cai XB, Zhao H, Zhu F, Wan XJ. Comparison of the safety and effectiveness of endoscopic biliary decompression by nasobiliary catheter and plastic stent placement in acute obstructive cholangitis. Swiss Med Wkly. 2013;143:w13823.PubMed
4.
Zurück zum Zitat Yang MJ, Hwang JC, Lee M, Noh CK, Kim SS, Yoo BM, Kim JH. Endoscopic hands-off technique versus conventional technique for conversion from an orobiliary to a nasobiliary tube. Gastroenterol Res Pract. 2016;2016:3678647.PubMedPubMedCentral Yang MJ, Hwang JC, Lee M, Noh CK, Kim SS, Yoo BM, Kim JH. Endoscopic hands-off technique versus conventional technique for conversion from an orobiliary to a nasobiliary tube. Gastroenterol Res Pract. 2016;2016:3678647.PubMedPubMedCentral
5.
Zurück zum Zitat Hamano T, Yoshida S, Nishino T, Akao J, Shirato I, Tagata T, Ikarashi Y, Mitsunaga Y, Shimada M, Mitsunaga A. A novel guide-wire technique for repositioning a nasobiliary catheter from mouth to nostril without using a nelaton tube. Med Princ Pract. 2015;24(4):339–43.CrossRef Hamano T, Yoshida S, Nishino T, Akao J, Shirato I, Tagata T, Ikarashi Y, Mitsunaga Y, Shimada M, Mitsunaga A. A novel guide-wire technique for repositioning a nasobiliary catheter from mouth to nostril without using a nelaton tube. Med Princ Pract. 2015;24(4):339–43.CrossRef
6.
Zurück zum Zitat Li K, Huang YH, Huang XB, Chang H, Yao W, Zhang YP. Nasobiliary tube placement: how to accomplish oral-to-nasal transfer. Endoscopy. 2015;47 Suppl 1 UCTN:E420.PubMed Li K, Huang YH, Huang XB, Chang H, Yao W, Zhang YP. Nasobiliary tube placement: how to accomplish oral-to-nasal transfer. Endoscopy. 2015;47 Suppl 1 UCTN:E420.PubMed
7.
Zurück zum Zitat Mallampati SR, Gatt SP, Gugino LD, Desai SP, Waraksa B, Freiberger D, Liu PL. A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J. 1985;32(4):429–34.CrossRef Mallampati SR, Gatt SP, Gugino LD, Desai SP, Waraksa B, Freiberger D, Liu PL. A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J. 1985;32(4):429–34.CrossRef
Metadaten
Titel
A novel technique for repositioning a nasobiliary catheter from the mouth to nostril in endoscopic retrograde cholangiopancreatography
verfasst von
Seong Ji Choi
Jae Min Lee
Hyuk Soon Choi
Eun Sun Kim
Bora Keum
Yeon Seok Seo
Yoon Tae Jeen
Hong Sik Lee
Hoon Jai Chun
Soon Ho Um
Chang Duck Kim
Chi Hyuk Oh
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
BMC Gastroenterology / Ausgabe 1/2019
Elektronische ISSN: 1471-230X
DOI
https://doi.org/10.1186/s12876-019-1148-0

Weitere Artikel der Ausgabe 1/2019

BMC Gastroenterology 1/2019 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Battle of Experts: Sport vs. Spritze bei Adipositas und Typ-2-Diabetes

11.05.2024 DDG-Jahrestagung 2024 Kongressbericht

Im Battle of Experts traten zwei Experten auf dem Diabeteskongress gegeneinander an: Die eine vertrat die Auffassung „Sport statt Spritze“ bei Adipositas und Typ-2-Diabetes, der andere forderte „Spritze statt Sport!“ Am Ende waren sie sich aber einig: Die Kombination aus beidem erzielt die besten Ergebnisse.

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Triglyzeridsenker schützt nicht nur Hochrisikopatienten

10.05.2024 Hypercholesterinämie Nachrichten

Patienten mit Arteriosklerose-bedingten kardiovaskulären Erkrankungen, die trotz Statineinnahme zu hohe Triglyzeridspiegel haben, profitieren von einer Behandlung mit Icosapent-Ethyl, und zwar unabhängig vom individuellen Risikoprofil.

Gibt es eine Wende bei den bioresorbierbaren Gefäßstützen?

In den USA ist erstmals eine bioresorbierbare Gefäßstütze – auch Scaffold genannt – zur Rekanalisation infrapoplitealer Arterien bei schwerer PAVK zugelassen worden. Das markiert einen Wendepunkt in der Geschichte dieser speziellen Gefäßstützen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.