Skip to main content
Erschienen in: Clinical Oral Investigations 4/2018

02.12.2017 | Original Article

Accuracy and eligibility of CBCT to digitize dental plaster casts

verfasst von: Kathrin Becker, Ulf Schmücker, Frank Schwarz, Dieter Drescher

Erschienen in: Clinical Oral Investigations | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Software-based dental planning requires digital casts and oftentimes cone-beam computed tomography (CBCT) radiography. However, buying a dedicated model digitizing device can be expensive and might not be required. The present study aimed to assess whether digital models derived from CBCT and models digitized using a dedicated optical device are of comparable accuracy.

Material and methods

A total of 20 plaster casts were digitized with eight CBCT and five optical model digitizers. Corresponding models were superimposed using six control points and subsequent iterative closest point matching. Median distances were calculated among all registered models. Data were pooled per scanner and model. Boxplots were generated, and the paired t test, a Friedman test, and a post-hoc Nemenyi test were employed for statistical comparison. Results were found significant at p < 0.05.

Results

All CBCT devices allowed the digitization of plaster casts, but failed to reach the accuracy of the dedicated model digitizers (p < 0.001). Median distances between CBCT and optically digitized casts were 0.064 + − 0.005 mm. Qualitative differences among the CBCT systems were detected (χ 2 = 78.07, p < 0.001), and one CBCT providing a special plaster cast digitization mode was found superior to the competitors (p < 0.05).

Conclusion

CBCT systems failed to reach the accuracy from optical digitizers, but within the limits of the study, accuracy appeared to be sufficient for digital planning and forensic purposes.

Clinical relevance

Most CBCT systems enabled digitization of plaster casts, and accuracy was found sufficient for digital planning and storage purposes.
Literatur
1.
Zurück zum Zitat De Luca Canto G, Pacheco-Pereira C, Lagravere MO, Flores-Mir C, Major PW (2015) Intra-arch dimensional measurement validity of laser-scanned digital dental models compared with the original plaster models: a systematic review. Orthod Craniofac Res 18(2):65–76. https://doi.org/10.1111/ocr.12068 CrossRefPubMed De Luca Canto G, Pacheco-Pereira C, Lagravere MO, Flores-Mir C, Major PW (2015) Intra-arch dimensional measurement validity of laser-scanned digital dental models compared with the original plaster models: a systematic review. Orthod Craniofac Res 18(2):65–76. https://​doi.​org/​10.​1111/​ocr.​12068 CrossRefPubMed
7.
Zurück zum Zitat Widmann G, Bale RJ (2006) Accuracy in computer-aided implant surgery—a review. Int J Oral Maxillofac Implants 21(2):305–313PubMed Widmann G, Bale RJ (2006) Accuracy in computer-aided implant surgery—a review. Int J Oral Maxillofac Implants 21(2):305–313PubMed
9.
Zurück zum Zitat Vermeulen J (2016) The accuracy of implant placement by experienced surgeons: guided vs freehand approach in a simulated plastic model. Int J Oral Maxillofac Implants. 10.11607/jomi.5065 Vermeulen J (2016) The accuracy of implant placement by experienced surgeons: guided vs freehand approach in a simulated plastic model. Int J Oral Maxillofac Implants. 10.​11607/​jomi.​5065
11.
Zurück zum Zitat Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle CH, Tahmaseb A (2009) Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 24(Suppl):92–109PubMed Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle CH, Tahmaseb A (2009) Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 24(Suppl):92–109PubMed
13.
Zurück zum Zitat Saxe AK, Louie LJ, Mah J (2010) Efficiency and effectiveness of SureSmile. World J Orthod 11(1):16–22PubMed Saxe AK, Louie LJ, Mah J (2010) Efficiency and effectiveness of SureSmile. World J Orthod 11(1):16–22PubMed
14.
Zurück zum Zitat Sachdeva RC, Aranha SL, Egan ME, Gross HT, Sachdeva NS, Currier GF, Kadioglu O (2012) Treatment time: SureSmile vs conventional. Orthodontics 13(1):72–85PubMed Sachdeva RC, Aranha SL, Egan ME, Gross HT, Sachdeva NS, Currier GF, Kadioglu O (2012) Treatment time: SureSmile vs conventional. Orthodontics 13(1):72–85PubMed
16.
Zurück zum Zitat Maino BG, Paoletto E, Lombardo L 3rd, Siciliani G (2016) A three-dimensional digital insertion guide for palatal miniscrew placement. J Clin Orthod 50(1):12–22PubMed Maino BG, Paoletto E, Lombardo L 3rd, Siciliani G (2016) A three-dimensional digital insertion guide for palatal miniscrew placement. J Clin Orthod 50(1):12–22PubMed
20.
Zurück zum Zitat Poleti ML, Fernandes TM, Pagin O, Moretti MR, Rubira-Bullen IR (2016) Analysis of linear measurements on 3D surface models using CBCT data segmentation obtained by automatic standard pre-set thresholds in two segmentation software programs: an in vitro study. Clin Oral Investig 20(1):179–185. https://doi.org/10.1007/s00784-015-1485-5 CrossRefPubMed Poleti ML, Fernandes TM, Pagin O, Moretti MR, Rubira-Bullen IR (2016) Analysis of linear measurements on 3D surface models using CBCT data segmentation obtained by automatic standard pre-set thresholds in two segmentation software programs: an in vitro study. Clin Oral Investig 20(1):179–185. https://​doi.​org/​10.​1007/​s00784-015-1485-5 CrossRefPubMed
21.
Metadaten
Titel
Accuracy and eligibility of CBCT to digitize dental plaster casts
verfasst von
Kathrin Becker
Ulf Schmücker
Frank Schwarz
Dieter Drescher
Publikationsdatum
02.12.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 4/2018
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-017-2277-x

Weitere Artikel der Ausgabe 4/2018

Clinical Oral Investigations 4/2018 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.