Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 11/2009

01.11.2009 | Original Article

Acetabular Polyethylene Wear and Acetabular Inclination and Femoral Offset

verfasst von: Nick J. Little, MSc, MRCS, Constant A. Busch, MD, FRCS, John A. Gallagher, MD, FRACS, Cecil H. Rorabeck, MD, FRCSC, Robert B. Bourne, MD, FRCSC

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 11/2009

Einloggen, um Zugang zu erhalten

Abstract

Restoration of femoral offset and acetabular inclination may have an effect on polyethylene (PE) wear in THA. We therefore assessed the effect of femoral offset and acetabular inclination (angle) on acetabular conventional (not highly cross-linked) PE wear in uncemented THA. We prospectively followed 43 uncemented THAs for a minimum of 49 months (mean, 64 months; range, 49–88 months). Radiographs were assessed for femoral offset, acetabular inclination, and conventional PE wear. The mean (± standard deviation) linear wear rate in all THAs was 0.14 mm/year (± 0.01 mm/year) and the mean volumetric wear rate was 53.1 mm3/year (± 5.5 mm3/year). In THAs with an acetabular angle less than 45°, the mean wear was 0.12 mm/year (± 0.01 mm/year) compared with 0.18 mm/year (± 0.02 mm/year) in those with a reconstructed acetabular angle greater than 45°. Reproduction of a reconstructed femoral offset to within 5 mm of the native femoral offset was associated with a reduction in conventional PE wear (0.12 mm/year versus 0.16 mm/year). Careful placement of the acetabular component to ensure an acetabular angle less than 45° in the reconstructed hip allows for reduced conventional PE wear.
Level of Evidence: Level II, prospective study. See Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Bankston AB, Cates H, Ritter MA, Keating EM, Faris PM. Polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 1995;317:7–13.PubMed Bankston AB, Cates H, Ritter MA, Keating EM, Faris PM. Polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 1995;317:7–13.PubMed
2.
Zurück zum Zitat Bankston AB, Faris PM, Keating EM, Ritter MA. Polyethylene wear in total hip arthroplasty in patient-matched groups: a comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces. J Arthroplasty. 1993;8:315–322.PubMedCrossRef Bankston AB, Faris PM, Keating EM, Ritter MA. Polyethylene wear in total hip arthroplasty in patient-matched groups: a comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces. J Arthroplasty. 1993;8:315–322.PubMedCrossRef
3.
Zurück zum Zitat Barrack RL. Factors influencing polyethylene wear in total joint arthroplasty. Orthopedics. 1998;21:937–940.PubMed Barrack RL. Factors influencing polyethylene wear in total joint arthroplasty. Orthopedics. 1998;21:937–940.PubMed
4.
Zurück zum Zitat Charles MN, Bourne RB, Davey JR, Greenwald AS, Morrey BF, Rorabeck CH. Soft-tissue balancing of the hip: the role of femoral offset restoration. Instr Course Lect. 2005;54:131–141.PubMed Charles MN, Bourne RB, Davey JR, Greenwald AS, Morrey BF, Rorabeck CH. Soft-tissue balancing of the hip: the role of femoral offset restoration. Instr Course Lect. 2005;54:131–141.PubMed
5.
Zurück zum Zitat Del Schutte H Jr, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D, Morrey BF. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty. 1998;13:621–626.PubMedCrossRef Del Schutte H Jr, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D, Morrey BF. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty. 1998;13:621–626.PubMedCrossRef
6.
Zurück zum Zitat Devane PA, Horne JG. Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res. 1999;369:59–72.PubMedCrossRef Devane PA, Horne JG. Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res. 1999;369:59–72.PubMedCrossRef
7.
Zurück zum Zitat Eggli S, z’Brun S, Gerber C, Ganz R. Comparison of polyethylene wear with femoral heads of 22 mm and 32 mm: a prospective, randomised study. J Bone Joint Surg Br. 2002;84:447–451.PubMedCrossRef Eggli S, z’Brun S, Gerber C, Ganz R. Comparison of polyethylene wear with femoral heads of 22 mm and 32 mm: a prospective, randomised study. J Bone Joint Surg Br. 2002;84:447–451.PubMedCrossRef
8.
Zurück zum Zitat Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years: a comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Joint Surg Am. 2004;86:257–261.PubMed Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years: a comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Joint Surg Am. 2004;86:257–261.PubMed
9.
Zurück zum Zitat Glyn-Jones S, Lardy-Smith P, Gill HS, Murray DW. The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg Br. 2008;90:556–561.PubMedCrossRef Glyn-Jones S, Lardy-Smith P, Gill HS, Murray DW. The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg Br. 2008;90:556–561.PubMedCrossRef
10.
Zurück zum Zitat Goosen JH, Verheyen CC, Tulp NJ. Mid-term wear characteristics of an uncemented acetabular component. J Bone Joint Surg Br. 2005;87:1475–1479.PubMedCrossRef Goosen JH, Verheyen CC, Tulp NJ. Mid-term wear characteristics of an uncemented acetabular component. J Bone Joint Surg Br. 2005;87:1475–1479.PubMedCrossRef
11.
Zurück zum Zitat Hansen T, Otto M, Buchhorn GH, Scharnweber D, Gaumann A, Delank KS, Eckardt A, Willert HG, Kriegsmann J, Kirkpatrick CJ. New aspects in the histological examination of polyethylene wear particles in failed total joint replacements. Acta Histochem. 2002;104:263–269.PubMedCrossRef Hansen T, Otto M, Buchhorn GH, Scharnweber D, Gaumann A, Delank KS, Eckardt A, Willert HG, Kriegsmann J, Kirkpatrick CJ. New aspects in the histological examination of polyethylene wear particles in failed total joint replacements. Acta Histochem. 2002;104:263–269.PubMedCrossRef
12.
Zurück zum Zitat Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T. Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res. 2001;388:135–142.PubMedCrossRef Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T. Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res. 2001;388:135–142.PubMedCrossRef
13.
Zurück zum Zitat Howie DW, Vernon-Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg Am. 1988;70:257–263.PubMed Howie DW, Vernon-Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg Am. 1988;70:257–263.PubMed
14.
Zurück zum Zitat Johnsen SP, Sorensen HT, Lucht U, Soballe K, Overgaard S, Pedersen AB. Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-terms: a nationwide Danish follow-up study including 36,984 patients. J Bone Joint Surg Br. 2006;88:1303–1308.PubMedCrossRef Johnsen SP, Sorensen HT, Lucht U, Soballe K, Overgaard S, Pedersen AB. Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-terms: a nationwide Danish follow-up study including 36,984 patients. J Bone Joint Surg Br. 2006;88:1303–1308.PubMedCrossRef
15.
Zurück zum Zitat Kligman M, Michael H, Roffman M. The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wear. Orthopedics. 2002;25:65–67.PubMed Kligman M, Michael H, Roffman M. The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wear. Orthopedics. 2002;25:65–67.PubMed
16.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed
17.
Zurück zum Zitat Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–528.PubMed Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–528.PubMed
18.
Zurück zum Zitat Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed
19.
Zurück zum Zitat McCalden RW, Naudie DD, Yuan X, Bourne RB. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2323–2334.PubMedCrossRef McCalden RW, Naudie DD, Yuan X, Bourne RB. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2323–2334.PubMedCrossRef
20.
Zurück zum Zitat Nogler M, Kessler O, Prassl A, Donnelly B, Streicher R, Sledge JB, Krismer M. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004;426:159–163.PubMedCrossRef Nogler M, Kessler O, Prassl A, Donnelly B, Streicher R, Sledge JB, Krismer M. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004;426:159–163.PubMedCrossRef
21.
Zurück zum Zitat Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(suppl 4):56–63.PubMed Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(suppl 4):56–63.PubMed
22.
Zurück zum Zitat Robinson RP, Simonian PT, Gradisar IM, Ching RP. Joint motion and surface contact area related to component position in total hip arthroplasty. J Bone Joint Surg Br. 1997;79:140–146.PubMedCrossRef Robinson RP, Simonian PT, Gradisar IM, Ching RP. Joint motion and surface contact area related to component position in total hip arthroplasty. J Bone Joint Surg Br. 1997;79:140–146.PubMedCrossRef
23.
Zurück zum Zitat Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.PubMedCrossRef Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.PubMedCrossRef
24.
Zurück zum Zitat Schmalzried TP, Huk OL. Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res. 2004;418:94–97.PubMedCrossRef Schmalzried TP, Huk OL. Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res. 2004;418:94–97.PubMedCrossRef
Metadaten
Titel
Acetabular Polyethylene Wear and Acetabular Inclination and Femoral Offset
verfasst von
Nick J. Little, MSc, MRCS
Constant A. Busch, MD, FRCS
John A. Gallagher, MD, FRACS
Cecil H. Rorabeck, MD, FRCSC
Robert B. Bourne, MD, FRCSC
Publikationsdatum
01.11.2009
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 11/2009
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-0845-3

Weitere Artikel der Ausgabe 11/2009

Clinical Orthopaedics and Related Research® 11/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.