Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 8/2012

Open Access 01.08.2012 | Basic Research

Are Shoulders with A Reverse Shoulder Prosthesis Strong Enough? A Pilot Study

verfasst von: Tjarco D. W. Alta, MD, H. E. J. Veeger, PhD, Thomas W. J. Janssen, PhD, W. Jaap Willems, MD, PhD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 8/2012

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Background

It has been suggested that limited active ROM of reverse shoulder prostheses relates to lack of strength. However, the postoperative strength has not been quantified.

Questions/purposes

We therefore measured joint torques in patients with reverse shoulder prostheses and correlated torques with functional scores.

Methods

We recruited 33 patients (age, 72 ± 8 years) with a reverse prosthesis (37 shoulders, 21 primary and 16 revisions). We obtained Constant-Murley, DASH, and Simple Shoulder Test ([D]SST) scores, and performed two isokinetic protocols (abduction/adduction and external/internal rotation) at 60° per second. Minimum followup was 4 months (average, 23 months; range, 4–63 months).

Results

Twenty-three patients (24 shoulders; 13 primaries, 11 revisions) were able to perform at least one of the defined tasks. Mean abduction and adduction torques were 15 Nm ± 7 Nm and 16 Nm ± 10 Nm (19%–78% of normal shoulders). External and internal rotation tasks could be performed by only 13 patients (14 shoulders; nine primary, five revisions) generating 9 Nm ± 4 Nm and 8 Nm ± 3 Nm, respectively (13%–71% of normal shoulders). We found moderate correlations between Constant-Murley, DASH and (D)SST (D = Dutch translation) scores and abduction and external rotation.

Conclusions

Patients with a reverse prosthesis had reduced strength when compared with normal values reported in the literature (only 65% of patients could perform the protocol). This effect was greatest for external rotation and might explain clinical outcomes with which a moderately strong relationship was observed. Our observations suggest limited strength is a major factor in reduced ROM.
Hinweise
One of the authors (WJW) received funding for this research from Tornier SA, France.
All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research editors and board members are on file with the publication and can be viewed on request.
Each author certifies that his or her institution approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained.
Patients were operated on at the Onze Lieve Vrouwe Gasthuis and Medisch Centrum Alkmaar, The Netherlands. The measurements were performed at Duyvensz-Nagel Research Laboratory, Reade, Centre for Rehabilitation and Rheumatology where the Biodex system is situated.

Introduction

The reverse shoulder prosthesis is one surgical option for treatment of cuff tear arthropathy and shoulder pseudoparalysis resulting from a massive cuff tear, severe fractures, prosthetic revision, and tumor surgery [5]. Owing to the mechanical advantage of a medialized center of rotation, the reverse shoulder prosthesis offers a potentially valuable surgical option and has become an alternative in situations in which the rotator cuff and/or the proximal humerus are destroyed or absent [5], with a satisfying reduction of pain after surgery [12, 31].
However, because of the wide variation in published values for active elevation after reverse shoulder replacement (ranging from 88° to 138° [3, 36]), the degree to which this prosthesis restores arm strength is not fully defined. Bergmann et al. previously found a better passive than active ROM [3] and presumed that the limited glenohumeral motion of the reverse prosthesis resulted from a lack of joint torque generation rather than a structural limitation caused by the prosthetic design.
Shoulder strength mostly has been evaluated using subjective methods such as traditional manual muscle testing and handheld dynamometry, which mainly focus on isometric muscle strength. The strength measure in the Constant-Murley score [8, 9] is also isometric. Because most functional activities are dynamic, evaluating isokinetic shoulder strength may be more appropriate when relating strength to functional performance and clinical outcome. However, data for isokinetic strength measurements around the shoulder are available only for normal healthy subjects [7], patients after open fixation of glenoid rim fractures [33], open [1, 10] and arthroscopic anterior stabilization [15, 21], rotator cuff surgery [4, 11, 14, 34, 43], with adhesive capsulitis [26, 27, 41], subacromial impingement [16, 24, 30], and pectoralis major muscle rupture [17], but not for patients with a reverse shoulder prosthesis.
Our objective was to perform a pilot study to measure isometric shoulder strength in patients who underwent either a primary or revision reverse shoulder replacement. We asked the following questions: (1) what joint torques can patients with a reverse shoulder prosthesis produce isokinetically, and (2) does this force-generating capacity correlate with functional scores?

Materials and Methods

Between May 2000 and September 2007, we treated 45 patients (49 shoulders) with a reverse shoulder prosthesis (Tornier®; Edina, MN, USA). Of these, 33 patients (19 women and 14 men), volunteered to participate in this study. Ten patients had surgery on the left side, 19 on the right side, and four on both sides (total of 37 shoulders). In 21 patients, the indication for the reverse prosthesis was cuff tear arthropathy, and in 16 patients the indication was revision after a failed primary placed hemiprosthesis or total shoulder prosthesis. The average time between surgery and measurement was 23 ± 14 months (range, 4–63 months). Mean age of the patients was 72 ± 8 years (range, 58–85 years). The minimum clinical followup was 4 months (mean, 23 months; range, 4–63 months). The institutional ethics committee approved the research protocol and all patients gave their written informed consent before the experiment.
All patients underwent surgery under general anesthesia with an interscalene nerve block in the beach-chair position. We used a standard deltopectoral approach in all patients. All glenoid components had been placed inferior on the glenoid surface with no inferior or superior inclination. Thirty patients had a 36-mm component implanted and seven had a 42-mm sphere diameter. The humeral components had all been placed in 10° to 20° retroversion, and in 32 patients, the teres minor and subscapularis muscles were still intact.
Postoperative management was the same for all patients, consisting of a sling and passive ROM exercises for 6 weeks. After 6 weeks, active assisted ROM exercises were started and at 3 months, strengthening exercises were added to the rehabilitation program.
Shoulder strength was measured with an isokinetic dynamometer, which provides constant velocity with accommodating resistance throughout a joint’s ROM. This resistance is provided using an electric or hydraulic servo-controlled mechanism at a user-defined constant velocity [13]. Two isokinetic protocols were performed to measure the strength of the subjects’ shoulder muscles on the surgically treated side using the Biodex System 3 Pro dynamometer (Biodex Medical Systems, New York, NY, USA). These protocols consisted of an abduction and adduction task and an external and internal rotation task with the arm in 60° abduction in a sitting position with securing bands around the subject’s chest and pelvis. For the abduction and adduction task, the chair was rotated 75° around the vertical axis with the dynamometer in neutral position and 10° tilted. For the external and internal rotation task, the chair was in the neutral position with the dynamometer rotated 20° and 50° tilted. After one session of the abduction and adduction or the external and internal rotation task, the subject had a 60-second recovery time after which the same task was repeated. All tasks were repeated five times at 60° per second with a minimum standard threshold of 15° per second to start the measurements defined by the Biodex System. For each motion, the average maximal torque (Nm) was determined over the two sessions. The subjects were instructed and encouraged to reach the highest possible force level during these tasks. Negative axial rotation was defined as external rotation and positive axial rotation as internal rotation.
Codine et al. [7] reported a systematic review of the literature on isokinetic strength of the shoulder until 2005. We used PubMed to identify other articles providing data for normal shoulder torque values from 2005 and onward [2, 20, 37, 42]. From those studies we took the abduction-adduction and/or external-internal rotation torque values for 60° per second or less and combined those to make comparison possible with our obtained data (Table 1).
Table 1
Maximum generated force in Nm for our data compared with the literature at similar or lower velocities
Study
Subject
Mean age (years)
Dominance or side
Velocity
Abduction
Adduction
External rotation
Internal rotation
Ambrosio et al. [2]
M and F wheelchair users
43
 
60°/second
50.0
42.5
28.2
32.3
Codine et al. [6]
M volunteers
26
D
60°/second
  
39.8
56.4
   
ND
   
42.7
56.2
 
M runners
23
D
60°/second
  
44.6
57.2
   
ND
   
45.8
54.7
 
M tennis players
26
D
60°/second
  
39.0
57.3
   
ND
   
40.1
54.0
 
M baseball players
20
D
60°/second
  
39.9
65.3
   
ND
   
39.8
55.5
Greenfield et al. [19]
M and F
25
 
60°/second
  
14.1
15.4
Harbo et al. [20]
M volunteers
53
 
60°/second
59.5
83.1
  
 
F volunteers
52
 
60°/second
37.4
45.7
  
Ivey et al. [22]
M
36
 
60°/second
37.5
61.0
21.8
33.2
 
F
26
 
60°/second
19.5
34.2
13.0
17.9
Sirota et al. [35]
M baseball players
24
D
60°/second
  
48.8
51.6
   
ND
   
44.2
52.3
Stickley et al. [37]
F volleyball athletes
13
 
60°/second
  
16.8
22.3
Tis and Maxwell [39]
F
25
D
60°/second
  
24.7
23.3
   
ND
   
24.7
21.2
Verney et al. [42]
M volunteers
73
 
60°/second
46.0
   
    
30°/second
50.0
   
McMaster et al. [28, 29]
M water polo players
26
Right
30°/second
51.8
99.1
38.2
65.9
   
Left
 
49.4
92.7
34.8
57.8
 
M swimming athletes
20
Right
30°/second
48.1
99.1
33.7
66.8
   
Left
 
48.6
102.2
31.8
55.9
 
M volunteers
22
Right
30°/second
35.3
54.0
29.1
39.9
   
Left
 
38.2
52.7
28.1
36.8
Otis et al. [32]
M
26
D
48°/second
49.6
 
26.6
42.2
   
ND
 
46.4
 
26.6
38.0
Current study
M and F reverse shoulder prosthesis
72
 
60°/second
15.2
16.1
9.3
8.2
M = male; F = female; D = dominant; ND = nondominant.
For clinical evaluation, we obtained preoperative and postoperative (absolute and relative) Constant-Murley scores [8, 9], postoperative DASH score [23], and the (D)SST [23, 40]. The absolute Constant-Murley score assesses the overall shoulder function and has a maximum score of 100 points. The relative Constant-Murley score is corrected for the age- and sex-related decline in force-generating capacity [46]. It is expressed as a percentage of the respective reference values. The DASH is a 30-item questionnaire that evaluates functional disability in everyday activities, work, and sports. It includes symptoms, physical, social, and psychological function. A DASH score of 0 indicates good shoulder function, or no disability, and the maximum score of 100 indicates no function. The (D)SST is a questionnaire consisting of 13 yes or no questions including subjective items and items that require patients to complete a physical exercise. It evaluates shoulder function in daily activities and a maximum score of 13 indicates good shoulder function.
We used a t-test to determine the difference in mean maximum generated torque at 60° per second between primary and revision cases. For this same group, the effect size was determined by calculating the Cohen’s d. The relationship between the clinical outcome scores (Constant-Murley, DASH, and [D]SST) and strength data was evaluated on the basis of a Pearson product-moment correlation.

Results

Only 23 patients (24 shoulders; 13 primary and 11 revisions) were able to generate sufficient velocity to perform the test, resulting in a mean abduction torque of 15.2 Nm ± 6.6 Nm for the whole group with no substantially better value for the primary prostheses compared with the revisions (Table 2). For the external and internal rotation torques, these values varied between 13% and 71%. We found similar torque values for adduction also with no major difference between primary and revision cases. The external and internal rotation tasks could be performed by only 13 patients (14 shoulders; nine primaries, five revisions). Mean external rotation torque was 9.3 Nm ± 4.4 Nm for the whole group with no major differences between the primary and revision groups. Internal rotation force tended to be higher (p = 0.07) for primary prostheses with a torque of 8.2 Nm ± 2.6 Nm for the whole group (Table 2). Compared with normal healthy subjects (Table 1), patients with a reverse prosthesis who could generate sufficient force to perform the tasks had abduction and adduction torques of 19% to 78% of those of a normal shoulder at a velocity of 60° per second.
Table 2
Mean maximum generated force (Nm) and SD at 60° per second for the whole group
Maximum torque at 60° per second
All shoulders (N = 24)
Primary (N = 13)
Revision (N = 11)
p value primary versus revision
Cohen’s d primary versus revision
Abduction
15.2 ± 6.6
16.3 ± 5.6
13.4 ± 7.6
0.30
0.43
Adduction
16.1 ± 10.0
20.4 ± 11.8
11.8 ± 6.0
0.11
0.92
 
(N = 14)
(N = 9)
(N = 5)
  
External rotation
9.3 ± 4.4
9.3 ± 4.7
7.9 ± 4.0
0.58
0.32
Internal rotation
8.2 ± 2.6
9.2 ± 2.1
6.0 ± 2.5
0.07
1.38
We found a correlation between the postoperative Constant-Murley score and the abduction and external rotation torques (Fig. 1). Similar correlations were found for the DASH score and (D)SST (Table 3), with the maximum torque values at 60° per second. There was no major correlation for the adduction and internal rotation motions. An overview of all the clinical outcome scores of the whole group, the primary and the revision cases is presented (Table 4).
Table 3
Pearson’s correlation between maximum torque at 60° per second and the postoperative Constant-Murley score, DASH, and (D)SST
Maximum torque at 60° per second
Constant-Murley score
DASH
(D)SST
Abduction
0.507
p = 0.014
−0.572
p = 0.004
0.519
p = 0.011
Adduction
0.393
p = 0.183
−0.319
p = 0.29
0.408
p = 0.166
External rotation
0.614
p = 0.026
−0.531
p = 0.062
0.600
p = 0.03
Internal rotation
0.441
p = 0.216
−0.498
p = 0.205
0.455
p = 0.206
(D)SST = Dutch translation of the Simple Shoulder Test.
Table 4
Constant-Murley scores, relative Constant-Murley scores, DASH scores, and (D)SST
Scores
All shoulders ± SD (range)
Primary ± SD (range)
Revision ± SD (range)
Constant-Murley preoperative
24 ± 11 (5–47)
28 ± 9 (13–47)
20 ± 12 (5–47)
Constant-Murley postoperative
50 ± 21 (8–87)
59 ± 20 (8–87)
38 ± 18 (11–73)
Relative Constant-Murley preoperative
33% ± 17% (7–71)
38% ± 14% (19–68)
27% ± 18% (7–71)
Relative Constant-Murley postoperative
70% ± 31% (9–124)
83% ± 30% (9–124)
53% ± 22% (14–92)
DASH postoperative
43.9 ± 25.6 (1.7–84.2)
31.5 ± 24.4 (1.7–77.5)
60.3 ± 17.1 (31.2–84.2)
(D)SST postoperative
7 ± 4 (0–13)
8 ± 4 (0–13)
4 ± 3 (1–10)
(D)SST = Dutch translation of the Simple Shoulder Test.

Discussion

The reverse shoulder prosthesis provides a surgical option for conditions such as cuff tear arthropathy, shoulder pseudoparalysis resulting from massive cuff tear, severe fractures, prosthetic revision, and tumor surgery [5] with generally satisfying postoperative results [12, 31]. However, the contribution of this prosthesis to restoration of arm function is less clear. Previous research [3] suggests the limited glenohumeral motion of the reverse prosthesis seems to be the result of a lack of joint torque generation rather than a structural limitation caused by the prosthetic design. Therefore, the evaluation of isokinetic shoulder strength after reverse shoulder replacement may be of interest in modeling dynamic upper extremity function, particularly where comparative data are not currently available for this clinical scenario. We therefore (1) determined joint torques in patients with a reverse shoulder prosthesis and (2) determined whether force-generating capacity correlates with functional scores.
We note limitations to our study, one of which is the absence of proper control data. First, ideally a comparison would be made with an age-matched control group without cuff disorders. However, with a prevalence of 31% of asymptomatic (ie, unrecognized) cuff tears in individuals between 70 and 79 years old [38] and a prevalence of 51% in individuals older than 80 years [38], this is not feasible without extensive screening. Another possibility would be to compare the outcomes with those of the contralateral side in the same patient. However, cuff disorders in the contralateral shoulder are not uncommon, as reported by Yamaguchi et al. [45] in their demographic and morphologic study of rotator cuff disease. The average age for patients with a bilateral cuff tear in their group was 67.8 years and logistic regression analysis indicated a 50% likelihood of a bilateral tear after the age of 66 years. Furthermore, patients with a full-thickness symptomatic tear had a 35.5% prevalence of a full-thickness tear on the contralateral side. In our patient population, 12% already had a reverse prosthesis on both sides, showing that our patient group was not suitable to use the contralateral side as a comparison. As a consequence data had to be compared with norm data from the literature. Second, we had a broad range of followup times for the force measurements and clinical outcome scores. Ideally the measurements should have been performed at the same time postoperatively for every patient with a minimum followup of 1 year. This is also true for the clinical outcome scores, because they require time to stabilize. In the scope of this study, it was not possible to include patients with the same followup period, as this would have required an inclusion period of several years. We therefore chose to include all patients available from our pool of treated patients, which inevitably led to a large range in followup times. It is not certain what effect the followup time will have had, which especially applies for the elderly population for whom recovery might be counteracted by ageing effects. Given the number of available patients, controlling for age and followup will be virtually impossible whereas including larger groups and testing for those factors also do not seem to be realistic options. Third, we limited our measurements to 60° per second. Isokinetic strength measurements have been performed at different velocities, mostly from 60° per second to 300° per second [7] with some exceptions at 30° per second (Table 1). In these measurements, the applied torque needs to increase above a threshold value to successfully perform a certain task at higher speeds. Because the physiologic changes at older age lead to a decline in force-generating capacity and the reverse shoulder prosthesis is implanted mainly in patients with a mean age of 72 years [18, 36], similar to the average age of the participants in our study, we decided to apply a relatively low velocity of 60° per second. Considering our data and the number of patients unable to perform the tests (Table 2), it appeared that even 60° per second was too high for most of the patients with a reverse prosthesis. Future research investigating force production of this patient population should incorporate velocities less than 60° per second. Whether a lower velocity would lead to substantially more successful tests however is unknown; in our protocol a standard threshold of 15° per second was used to start measurements, which even proved to be too much for some of our patients.
Trying to place our obtained torque values (Table 2) in perspective, we compared our data with those of normal healthy subjects (Table 1). From this comparison we can conclude that patients with a reverse prosthesis who can generate sufficient force to perform the tasks have abduction and adduction torques of 19% to 78% of those of a normal shoulder at a velocity of 60° per second. For the external and internal rotation torques, these values vary between 13% and 71%. However, those normal values were based on younger subjects than our group of patients and in most series they include groups of athletes. If we compare our data with the only age-related series of Verney et al. [42], our patients have an abduction torque of 33% of that of 10 male elderly volunteers. It is not clear what causes this relatively low abduction torque. From the total of 37 shoulders, only 23 patients (24 shoulders) could generate enough force to perform the abduction and adduction tasks and for the external and internal rotation, the number of patients was even less (Table 2). The difference between those two tasks can be explained by the changed biomechanics caused by the reverse shoulder prosthesis. By displacing the center of rotation medially, more fibers of the anterior and posterior parts of the deltoid muscle are recruited for anteflexion or abduction of the arm and therefore fewer fibers are available to internally or externally rotate the arm [5]. Our study group included patients with primary and revision implantations. In revision surgery with a reverse prosthesis, the improvement of function is reportedly only to approximately 70° of active elevation [25], with a higher complication rate [44] than with primary surgery. Therefore, we expected to find a difference in force-generating capacity between the two groups (Table 2) in favor of the primary prosthesis. However, this could not be confirmed for the abduction and adduction tasks because 62% of the primary and 69% of the revision cases were able to generate enough force. For the internal and external rotation tasks, it was 43% and 31% respectively, confirming our expectation and explained by the previously mentioned change of biomechanics after a reverse prosthesis.
Impaired shoulder strength is likely one of the causes of active ROM limitations. The correlations we found between clinical outcome scores (Constant-Murley, DASH, and [D]SST) and the abduction and external rotation torque values (Table 3) support this contention. Functional outcome probably is not determined by simple ROM ranges alone, but also by the actual capacity for material handling in elevated and axially rotated arm positions. For example, it can be expected that patients who have good anteflexion or abduction with limited external rotation strength define their functional outcome as poor. Therefore, it seems logical that greater external rotation torque provides a better functional outcome. Although our findings support this notion, only 13 of a total of 37 shoulders actually were able to generate enough force to perform the tasks at 60° per second. Testing under lighter conditions (30° per second) could have provided more data but probably would not have led to another observation.
Patients with a reverse prosthesis were moderately to strongly limited in strength, which was the case for abduction and adduction and even more for external and internal rotation. However, future isokinetic data collection in these patients should be performed at a lower velocity than 60° per second. Results for strength correlated with clinical outcome scores (Constant-Murley, DASH, and [D]SST) indicating moderately strong relationships and a moderate predictive value of the outcome scores. Although it is likely that lower isokinetic shoulder strength in patients with joint arthroplasties is a major factor in reduced ROM, the actual causes of loss of strength would need to be identified in future studies.

Acknowledgments

We thank Jeroen H. M. Bergmann PhD, Department of Cancer & Surgery, Imperial College London, UK, for assistance with the measurements and critical comments while writing the draft. We also thank Bart J. Burger MD, PhD, orthopaedic surgeon at Medic Centrum Alkmaar, The Netherlands, for allowing us to perform measurements on his patients.

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Amako M, Imai T, Okamura K. Recovery of shoulder rotational muscle strength after a combined Bankart and modified Bristow procedure. J Shoulder Elbow Surg. 2008;17:738–743.PubMedCrossRef Amako M, Imai T, Okamura K. Recovery of shoulder rotational muscle strength after a combined Bankart and modified Bristow procedure. J Shoulder Elbow Surg. 2008;17:738–743.PubMedCrossRef
2.
Zurück zum Zitat Ambrosio F, Boninger ML, Souza AL, Fitzgerald SG, Koontz AM, Cooper RA. Biomechanics and strength of manual wheelchair users. J Spinal Cord Med. 2005;28:407–414.PubMed Ambrosio F, Boninger ML, Souza AL, Fitzgerald SG, Koontz AM, Cooper RA. Biomechanics and strength of manual wheelchair users. J Spinal Cord Med. 2005;28:407–414.PubMed
3.
Zurück zum Zitat Bergmann JH, de Leeuw M, Janssen TW, Veeger DH, Willems WJ. Contribution of the reverse endoprosthesis to glenohumeral kinematics. Clin Orthop Relat Res. 2008;466:594–598.PubMedCrossRef Bergmann JH, de Leeuw M, Janssen TW, Veeger DH, Willems WJ. Contribution of the reverse endoprosthesis to glenohumeral kinematics. Clin Orthop Relat Res. 2008;466:594–598.PubMedCrossRef
4.
Zurück zum Zitat Bigoni M, Gorla M, Guerrasio S, Brignoli A, Cossio A, Grillo P, Marinoni EC. Shoulder evaluation with isokinetic strength testing after arthroscopic rotator cuff repairs. J Shoulder Elbow Surg. 2009;18:178–183.PubMedCrossRef Bigoni M, Gorla M, Guerrasio S, Brignoli A, Cossio A, Grillo P, Marinoni EC. Shoulder evaluation with isokinetic strength testing after arthroscopic rotator cuff repairs. J Shoulder Elbow Surg. 2009;18:178–183.PubMedCrossRef
5.
Zurück zum Zitat Boileau P, Watkinson DJ, Hatzidakis AM, Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14(1 suppl):147S–161S.PubMedCrossRef Boileau P, Watkinson DJ, Hatzidakis AM, Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14(1 suppl):147S–161S.PubMedCrossRef
6.
Zurück zum Zitat Codine P, Bernard PL, Pocholle M, Benaim C, Brun V. Influence of sports discipline on shoulder rotator cuff balance. Med Sci Sports Exerc. 1997;29:1400–1405.PubMedCrossRef Codine P, Bernard PL, Pocholle M, Benaim C, Brun V. Influence of sports discipline on shoulder rotator cuff balance. Med Sci Sports Exerc. 1997;29:1400–1405.PubMedCrossRef
7.
Zurück zum Zitat Codine P, Bernard PL, Pocholle M, Herisson C. [Isokinetic strength measurement and training of the shoulder: methodology and results] [in French]. Ann Readapt Med Phys. 2005;48:80–92.PubMedCrossRef Codine P, Bernard PL, Pocholle M, Herisson C. [Isokinetic strength measurement and training of the shoulder: methodology and results] [in French]. Ann Readapt Med Phys. 2005;48:80–92.PubMedCrossRef
8.
Zurück zum Zitat Constant CR, Gerber C, Emery RJ, Sojbjerg JO, Gohlke F, Boileau P. A review of the Constant score: modifications and guidelines for its use. J Shoulder Elbow Surg. 2008;17:355–361.PubMedCrossRef Constant CR, Gerber C, Emery RJ, Sojbjerg JO, Gohlke F, Boileau P. A review of the Constant score: modifications and guidelines for its use. J Shoulder Elbow Surg. 2008;17:355–361.PubMedCrossRef
9.
Zurück zum Zitat Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;214:160–164.PubMed Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;214:160–164.PubMed
10.
Zurück zum Zitat Dauty M, Dominique H, Helena A, Charles D. [Evolution of the isokinetic torque of shoulder rotators before and after 3 months of shoulder stabilization by the Latarjet technique] [in French]. Ann Readapt Med Phys. 2007;50:201–208.PubMedCrossRef Dauty M, Dominique H, Helena A, Charles D. [Evolution of the isokinetic torque of shoulder rotators before and after 3 months of shoulder stabilization by the Latarjet technique] [in French]. Ann Readapt Med Phys. 2007;50:201–208.PubMedCrossRef
11.
Zurück zum Zitat Demirors H, Circi E, Akgun RC, Tarhan NC, Cetin N, Akpinar S, Tuncay IC. Correlations of isokinetic measurements with tendon healing following open repair of rotator cuff tears. Int Orthop. 2010;34:531–536.PubMedCrossRef Demirors H, Circi E, Akgun RC, Tarhan NC, Cetin N, Akpinar S, Tuncay IC. Correlations of isokinetic measurements with tendon healing following open repair of rotator cuff tears. Int Orthop. 2010;34:531–536.PubMedCrossRef
12.
Zurück zum Zitat Drake GN, O’Connor DP, Edwards TB. Indications for reverse total shoulder arthroplasty in rotator cuff disease. Clin Orthop Relat Res. 2010;468:1526–1533.PubMedCrossRef Drake GN, O’Connor DP, Edwards TB. Indications for reverse total shoulder arthroplasty in rotator cuff disease. Clin Orthop Relat Res. 2010;468:1526–1533.PubMedCrossRef
13.
Zurück zum Zitat Drouin JM, Valovich-mcLeod TC, Shultz SJ, Gansneder BM, Perrin DH. Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements. Eur J Appl Physiol. 2004;91:22–29.PubMedCrossRef Drouin JM, Valovich-mcLeod TC, Shultz SJ, Gansneder BM, Perrin DH. Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements. Eur J Appl Physiol. 2004;91:22–29.PubMedCrossRef
14.
Zurück zum Zitat Ellenbecker TS, Elmore E, Bailie DS. Descriptive report of shoulder range of motion and rotational strength 6 and 12 weeks following rotator cuff repair using a mini-open deltoid splitting technique. J Orthop Sports Phys Ther. 2006;36:326–335.PubMed Ellenbecker TS, Elmore E, Bailie DS. Descriptive report of shoulder range of motion and rotational strength 6 and 12 weeks following rotator cuff repair using a mini-open deltoid splitting technique. J Orthop Sports Phys Ther. 2006;36:326–335.PubMed
15.
Zurück zum Zitat Ellenbecker TS, Mattalino AJ. Glenohumeral joint range of motion and rotator cuff strength following arthroscopic anterior stabilization with thermal capsulorraphy. J Orthop Sports Phys Ther. 1999;29:160–167.PubMed Ellenbecker TS, Mattalino AJ. Glenohumeral joint range of motion and rotator cuff strength following arthroscopic anterior stabilization with thermal capsulorraphy. J Orthop Sports Phys Ther. 1999;29:160–167.PubMed
16.
Zurück zum Zitat Erol O, Ozcakar L, Celiker R. Shoulder rotator strength in patients with stage I-II subacromial impingement: relationship to pain, disability, and quality of life. J Shoulder Elbow Surg. 2008;17:893–897.PubMedCrossRef Erol O, Ozcakar L, Celiker R. Shoulder rotator strength in patients with stage I-II subacromial impingement: relationship to pain, disability, and quality of life. J Shoulder Elbow Surg. 2008;17:893–897.PubMedCrossRef
17.
Zurück zum Zitat Fleury AM, Silva AC, Pochini A, Ejnisman B, Lira CA, Andrade Mdos S. Isokinetic muscle assessment after treatment of pectoralis major muscle rupture using surgical or non-surgical procedures. Clinics (Sao Paulo). 2011;66:313–320.PubMedCrossRef Fleury AM, Silva AC, Pochini A, Ejnisman B, Lira CA, Andrade Mdos S. Isokinetic muscle assessment after treatment of pectoralis major muscle rupture using surgical or non-surgical procedures. Clinics (Sao Paulo). 2011;66:313–320.PubMedCrossRef
18.
Zurück zum Zitat Gerber C, Pennington SD, Nyffeler RW. Reverse total shoulder arthroplasty. J Am Acad Orthop Surg. 2009;17:284–295.PubMed Gerber C, Pennington SD, Nyffeler RW. Reverse total shoulder arthroplasty. J Am Acad Orthop Surg. 2009;17:284–295.PubMed
19.
Zurück zum Zitat Greenfield BH, Donatelli R, Wooden MJ, Wilkes J. Isokinetic evaluation of shoulder rotational strength between the plane of scapula and the frontal plane. Am J Sports Med. 1990;18:124–128.PubMedCrossRef Greenfield BH, Donatelli R, Wooden MJ, Wilkes J. Isokinetic evaluation of shoulder rotational strength between the plane of scapula and the frontal plane. Am J Sports Med. 1990;18:124–128.PubMedCrossRef
20.
Zurück zum Zitat Harbo T, Brincks J, Andersen H. Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body mass, height, and sex in 178 healthy subjects. Eur J Appl Physiol. 2011;112:267–275.PubMedCrossRef Harbo T, Brincks J, Andersen H. Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body mass, height, and sex in 178 healthy subjects. Eur J Appl Physiol. 2011;112:267–275.PubMedCrossRef
21.
Zurück zum Zitat Hiemstra LA, Sasyniuk TM, Mohtadi NG, Fick GH. Shoulder strength after open versus arthroscopic stabilization. Am J Sports Med. 2008;36:861–867.PubMedCrossRef Hiemstra LA, Sasyniuk TM, Mohtadi NG, Fick GH. Shoulder strength after open versus arthroscopic stabilization. Am J Sports Med. 2008;36:861–867.PubMedCrossRef
22.
Zurück zum Zitat Ivey FM Jr, Calhoun JH, Rusche K, Bierschenk J. Isokinetic testing of shoulder strength: normal values. Arch Phys Med Rehabil. 1985;66:384–386.PubMed Ivey FM Jr, Calhoun JH, Rusche K, Bierschenk J. Isokinetic testing of shoulder strength: normal values. Arch Phys Med Rehabil. 1985;66:384–386.PubMed
23.
Zurück zum Zitat Kirkley A, Griffin S, Dainty K. Scoring systems for the functional assessment of the shoulder. Arthroscopy. 2003;19:1109–1120.PubMedCrossRef Kirkley A, Griffin S, Dainty K. Scoring systems for the functional assessment of the shoulder. Arthroscopy. 2003;19:1109–1120.PubMedCrossRef
24.
Zurück zum Zitat Leroux JL, Codine P, Thomas E, Pocholle M, Mailhe D, Blotman F. Isokinetic evaluation of rotational strength in normal shoulders and shoulders with impingement syndrome. Clin Orthop Relat Res. 1994;304:108–115.PubMed Leroux JL, Codine P, Thomas E, Pocholle M, Mailhe D, Blotman F. Isokinetic evaluation of rotational strength in normal shoulders and shoulders with impingement syndrome. Clin Orthop Relat Res. 1994;304:108–115.PubMed
25.
Zurück zum Zitat Levy JC, Virani N, Pupello D, Frankle M. Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency. J Bone Joint Surg Br. 2007;89:189–195.PubMedCrossRef Levy JC, Virani N, Pupello D, Frankle M. Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency. J Bone Joint Surg Br. 2007;89:189–195.PubMedCrossRef
26.
Zurück zum Zitat Liem D, Meier F, Thorwesten L, Marquardt B, Steinbeck J, Poetzl W. The influence of arthroscopic subscapularis tendon and capsule release on internal rotation strength in treatment of frozen shoulder. Am J Sports Med. 2008;36:921–926.PubMedCrossRef Liem D, Meier F, Thorwesten L, Marquardt B, Steinbeck J, Poetzl W. The influence of arthroscopic subscapularis tendon and capsule release on internal rotation strength in treatment of frozen shoulder. Am J Sports Med. 2008;36:921–926.PubMedCrossRef
27.
Zurück zum Zitat Lin HC, Li JS, Lo SF, Shih YF, Lo CY, Chen SY. Isokinetic characteristics of shoulder rotators in patients with adhesive capsulitis. J Rehabil Med. 2009;41:563–568.PubMedCrossRef Lin HC, Li JS, Lo SF, Shih YF, Lo CY, Chen SY. Isokinetic characteristics of shoulder rotators in patients with adhesive capsulitis. J Rehabil Med. 2009;41:563–568.PubMedCrossRef
28.
Zurück zum Zitat McMaster WC, Long SC, Caiozzo VJ. Isokinetic torque imbalances in the rotator cuff of the elite water polo player. Am J Sports Med. 1991;19:72–75.PubMedCrossRef McMaster WC, Long SC, Caiozzo VJ. Isokinetic torque imbalances in the rotator cuff of the elite water polo player. Am J Sports Med. 1991;19:72–75.PubMedCrossRef
29.
Zurück zum Zitat McMaster WC, Long SC, Caiozzo VJ. Shoulder torque changes in the swimming athlete. Am J Sports Med. 1992;20:323–327.PubMedCrossRef McMaster WC, Long SC, Caiozzo VJ. Shoulder torque changes in the swimming athlete. Am J Sports Med. 1992;20:323–327.PubMedCrossRef
30.
Zurück zum Zitat Moraes GF, Faria CD, Teixeira-Salmela LF. Scapular muscle recruitment patterns and isokinetic strength ratios of the shoulder rotator muscles in individuals with and without impingement syndrome. J Shoulder Elbow Surg. 2008;17(1 suppl):48S–53S.PubMedCrossRef Moraes GF, Faria CD, Teixeira-Salmela LF. Scapular muscle recruitment patterns and isokinetic strength ratios of the shoulder rotator muscles in individuals with and without impingement syndrome. J Shoulder Elbow Surg. 2008;17(1 suppl):48S–53S.PubMedCrossRef
31.
Zurück zum Zitat Naveed MA, Kitson J, Bunker TD. The Delta III reverse shoulder replacement for cuff tear arthropathy: a single-centre study of 50 consecutive procedures. J Bone Joint Surg Br. 2011;93:57–61.PubMed Naveed MA, Kitson J, Bunker TD. The Delta III reverse shoulder replacement for cuff tear arthropathy: a single-centre study of 50 consecutive procedures. J Bone Joint Surg Br. 2011;93:57–61.PubMed
32.
Zurück zum Zitat Otis JC, Warren RF, Backus SI, Santner TJ, Mabrey JD. Torque production in the shoulder of the normal young adult male: the interaction of function, dominance, joint angle, and angular velocity. Am J Sports Med. 1990;18:119–123.PubMedCrossRef Otis JC, Warren RF, Backus SI, Santner TJ, Mabrey JD. Torque production in the shoulder of the normal young adult male: the interaction of function, dominance, joint angle, and angular velocity. Am J Sports Med. 1990;18:119–123.PubMedCrossRef
33.
Zurück zum Zitat Raiss P, Baumann F, Akbar M, Rickert M, Loew M. Open screw fixation of large anterior glenoid rim fractures: mid- and long-term results in 29 patients. Knee Surg Sports Traumatol Arthrosc. 2009;17:195–203.PubMedCrossRef Raiss P, Baumann F, Akbar M, Rickert M, Loew M. Open screw fixation of large anterior glenoid rim fractures: mid- and long-term results in 29 patients. Knee Surg Sports Traumatol Arthrosc. 2009;17:195–203.PubMedCrossRef
34.
Zurück zum Zitat Rokito AS, Zuckerman JD, Gallagher MA, Cuomo F. Strength after surgical repair of the rotator cuff. J Shoulder Elbow Surg. 1996;5:12–17.PubMedCrossRef Rokito AS, Zuckerman JD, Gallagher MA, Cuomo F. Strength after surgical repair of the rotator cuff. J Shoulder Elbow Surg. 1996;5:12–17.PubMedCrossRef
35.
Zurück zum Zitat Sirota SC, Malanga GA, Eischen JJ, Laskowski ER. An eccentric- and concentric-strength profile of shoulder external and internal rotator muscles in professional baseball pitchers. Am J Sports Med. 1997;25:59–64.PubMedCrossRef Sirota SC, Malanga GA, Eischen JJ, Laskowski ER. An eccentric- and concentric-strength profile of shoulder external and internal rotator muscles in professional baseball pitchers. Am J Sports Med. 1997;25:59–64.PubMedCrossRef
36.
Zurück zum Zitat Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff: results of a multicentre study of 80 shoulders. J Bone Joint Surg Br. 2004;86:388–395.PubMedCrossRef Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff: results of a multicentre study of 80 shoulders. J Bone Joint Surg Br. 2004;86:388–395.PubMedCrossRef
37.
Zurück zum Zitat Stickley CD, Hetzler RK, Freemyer BG, Kimura IF. Isokinetic peak torque ratios and shoulder injury history in adolescent female volleyball athletes. J Athl Train. 2008;43:571–577.PubMedCrossRef Stickley CD, Hetzler RK, Freemyer BG, Kimura IF. Isokinetic peak torque ratios and shoulder injury history in adolescent female volleyball athletes. J Athl Train. 2008;43:571–577.PubMedCrossRef
38.
Zurück zum Zitat Tempelhof S, Rupp S, Seil R. Age-related prevalence of rotator cuff tears in asymptomatic shoulders. J Shoulder Elbow Surg. 1999;8:296–299.PubMedCrossRef Tempelhof S, Rupp S, Seil R. Age-related prevalence of rotator cuff tears in asymptomatic shoulders. J Shoulder Elbow Surg. 1999;8:296–299.PubMedCrossRef
39.
Zurück zum Zitat Tis LL, Maxwell T. The effect of positioning on shoulder isokinetic measures in females. Med Sci Sports Exerc. 1996;28:1188–1192.PubMedCrossRef Tis LL, Maxwell T. The effect of positioning on shoulder isokinetic measures in females. Med Sci Sports Exerc. 1996;28:1188–1192.PubMedCrossRef
40.
Zurück zum Zitat van Laarhoven HA, te Slaa RL, de Boer LM, Willems WJ. The Dutch Simple Shoulder Test, an efficient way of assessing shoulder function. Dutch J Orthop. 2001;8:5–8. van Laarhoven HA, te Slaa RL, de Boer LM, Willems WJ. The Dutch Simple Shoulder Test, an efficient way of assessing shoulder function. Dutch J Orthop. 2001;8:5–8.
41.
Zurück zum Zitat van Meeteren J, Roebroeck ME, Selles RW, Stam HJ. Responsiveness of isokinetic dynamometry parameters, pain and activity level scores to evaluate changes in patients with capsulitis of the shoulder. Clin Rehabil. 2006;20:496–501.PubMedCrossRef van Meeteren J, Roebroeck ME, Selles RW, Stam HJ. Responsiveness of isokinetic dynamometry parameters, pain and activity level scores to evaluate changes in patients with capsulitis of the shoulder. Clin Rehabil. 2006;20:496–501.PubMedCrossRef
42.
Zurück zum Zitat Verney J, Kadi F, Saafi MA, Piehl-Aulin K, Denis C. Combined lower body endurance and upper body resistance training improves performance and health parameters in healthy active elderly. Eur J Appl Physiol. 2006;97:288–297.PubMedCrossRef Verney J, Kadi F, Saafi MA, Piehl-Aulin K, Denis C. Combined lower body endurance and upper body resistance training improves performance and health parameters in healthy active elderly. Eur J Appl Physiol. 2006;97:288–297.PubMedCrossRef
43.
Zurück zum Zitat Walker SW, Couch WH, Boester GA, Sprowl DW. Isokinetic strength of the shoulder after repair of a torn rotator cuff. J Bone Joint Surg Am. 1987;69:1041–1044.PubMed Walker SW, Couch WH, Boester GA, Sprowl DW. Isokinetic strength of the shoulder after repair of a torn rotator cuff. J Bone Joint Surg Am. 1987;69:1041–1044.PubMed
44.
Zurück zum Zitat Wall B, Nove-Josserand L, O’Connor DP, Edwards TB, Walch G. Reverse total shoulder arthroplasty: a review of results according to etiology. J Bone Joint Surg Am. 2007;89:1476–1485.PubMedCrossRef Wall B, Nove-Josserand L, O’Connor DP, Edwards TB, Walch G. Reverse total shoulder arthroplasty: a review of results according to etiology. J Bone Joint Surg Am. 2007;89:1476–1485.PubMedCrossRef
45.
Zurück zum Zitat Yamaguchi K, Ditsios K, Middleton WD, Hildebolt CF, Galatz LM, Teefey SA. The demographic and morphological features of rotator cuff disease: a comparison of asymptomatic and symptomatic shoulders. J Bone Joint Surg Am. 2006;88:1699–1704.PubMedCrossRef Yamaguchi K, Ditsios K, Middleton WD, Hildebolt CF, Galatz LM, Teefey SA. The demographic and morphological features of rotator cuff disease: a comparison of asymptomatic and symptomatic shoulders. J Bone Joint Surg Am. 2006;88:1699–1704.PubMedCrossRef
46.
Zurück zum Zitat Yian EH, Ramappa AJ, Arneberg O, Gerber C. The Constant score in normal shoulders. J Shoulder Elbow Surg. 2005;14:128–133.PubMedCrossRef Yian EH, Ramappa AJ, Arneberg O, Gerber C. The Constant score in normal shoulders. J Shoulder Elbow Surg. 2005;14:128–133.PubMedCrossRef
Metadaten
Titel
Are Shoulders with A Reverse Shoulder Prosthesis Strong Enough? A Pilot Study
verfasst von
Tjarco D. W. Alta, MD
H. E. J. Veeger, PhD
Thomas W. J. Janssen, PhD
W. Jaap Willems, MD, PhD
Publikationsdatum
01.08.2012
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 8/2012
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2277-8

Weitere Artikel der Ausgabe 8/2012

Clinical Orthopaedics and Related Research® 8/2012 Zur Ausgabe

Symposium: Disruptions of the Pelvic Ring: An Update

What are Predictors of Mortality in Patients with Pelvic Fractures?

Symposium: Disruptions of the Pelvic Ring: An Update

The Classic: Dislocation and Fracture-Dislocation of the Pelvis

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.