Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2008

01.03.2008 | Knee

Arthroscopic fixation of anterior cruciate ligament tibial avulsion fractures using bioabsorbable suture anchors

verfasst von: Yong In, Jung-Man Kim, Young-Kyun Woo, Nam-Yong Choi, Chan-Woong Moon, Min-Woo Kim

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 3/2008

Einloggen, um Zugang zu erhalten

Abstract

This article describes a new technique for the arthroscopic reduction and fixation of anterior cruciate ligament (ACL) tibial avulsion fractures using bioabsorbable suture anchors. This described technique requires the use of anterolateral, anteromedial, medial mid-patellar, and lateral mid-patellar portals. A suture hook loaded with No. 2 polydioxanone (PDS) was used to pierce the ACL through the anteromedial or anterolateral portal, and bioabsorbable suture anchors were inserted through the medial and lateral mid-patellar portals. The five patients treated using this technique were evaluated at 1 year postoperatively. All patients showed bony union without anterior laxity or flexion contracture. The described technique provides firm fixation of fracture fragment and can be used in both skeletally immature and mature patients.
Literatur
1.
Zurück zum Zitat Baczkowski B, Lorczynski A, Kabula J, Camilleri R (2006) Scapholunate ligament repair using suture anchors. Ortop Traumatol Rehabil 8:129–133PubMed Baczkowski B, Lorczynski A, Kabula J, Camilleri R (2006) Scapholunate ligament repair using suture anchors. Ortop Traumatol Rehabil 8:129–133PubMed
2.
Zurück zum Zitat Berg EE (1995) Pediatric tibial eminence fractures: arthroscopic cannulated screw fixation. Arthroscopy 11:328–331PubMedCrossRef Berg EE (1995) Pediatric tibial eminence fractures: arthroscopic cannulated screw fixation. Arthroscopy 11:328–331PubMedCrossRef
3.
Zurück zum Zitat Bushnell BD, Byram IR, Weinhold PS, Creighton RA (2006) The use of suture anchors in repair of the ruptured patellar tendon: a biomechanical study. Am J Sports Med 34:1492–1499PubMedCrossRef Bushnell BD, Byram IR, Weinhold PS, Creighton RA (2006) The use of suture anchors in repair of the ruptured patellar tendon: a biomechanical study. Am J Sports Med 34:1492–1499PubMedCrossRef
4.
Zurück zum Zitat Jung YB, Yum JK, Koo BH (1999) A new method for arthroscopic treatment of tibial eminence fractures with eyed Steinmann pins. Arthroscopy 15:672–675PubMedCrossRef Jung YB, Yum JK, Koo BH (1999) A new method for arthroscopic treatment of tibial eminence fractures with eyed Steinmann pins. Arthroscopy 15:672–675PubMedCrossRef
5.
Zurück zum Zitat Kandziora F, Jager A, Bischof F, Herresthal J, Starker M, Mittlmeier T (2000) Arthroscopic labrum refixation for post-traumatic anterior shoulder instability: suture anchor versus transglenoid fixation technique. Arthroscopy 16:359–366PubMedCrossRef Kandziora F, Jager A, Bischof F, Herresthal J, Starker M, Mittlmeier T (2000) Arthroscopic labrum refixation for post-traumatic anterior shoulder instability: suture anchor versus transglenoid fixation technique. Arthroscopy 16:359–366PubMedCrossRef
6.
Zurück zum Zitat Kendall NS, Hsu SY, Chan KM (1992) Fracture of the tibial spine in adults and children. A review of 31 cases. J Bone Joint Surg Br 74:848–852PubMed Kendall NS, Hsu SY, Chan KM (1992) Fracture of the tibial spine in adults and children. A review of 31 cases. J Bone Joint Surg Br 74:848–852PubMed
7.
Zurück zum Zitat Kogan MG, Marks P, Amendola A (1997) Technique for arthroscopic suture fixation of displaced tibial intercondylar eminence fractures. Arthroscopy 13:301–306PubMedCrossRef Kogan MG, Marks P, Amendola A (1997) Technique for arthroscopic suture fixation of displaced tibial intercondylar eminence fractures. Arthroscopy 13:301–306PubMedCrossRef
8.
Zurück zum Zitat Lehman RA Jr, Murphy KP, Machen MS, Kuklo TR (2003) Modified arthroscopic suture fixation of a displaced tibial eminence fracture. Arthroscopy 19:E6PubMedCrossRef Lehman RA Jr, Murphy KP, Machen MS, Kuklo TR (2003) Modified arthroscopic suture fixation of a displaced tibial eminence fracture. Arthroscopy 19:E6PubMedCrossRef
9.
Zurück zum Zitat Lubowitz JH, Elson WS, Guttmann D (2005) Part II. Arthroscopic treatment of tibial plateau fractures: intercondylar eminence avulsion fractures. Arthroscopy 21:86–92PubMedCrossRef Lubowitz JH, Elson WS, Guttmann D (2005) Part II. Arthroscopic treatment of tibial plateau fractures: intercondylar eminence avulsion fractures. Arthroscopy 21:86–92PubMedCrossRef
10.
Zurück zum Zitat Lubowitz JH, Grauer JD (1993) Arthroscopic treatment of anterior cruciate ligament avulsion. Clin Orthop 294:242–246PubMed Lubowitz JH, Grauer JD (1993) Arthroscopic treatment of anterior cruciate ligament avulsion. Clin Orthop 294:242–246PubMed
11.
Zurück zum Zitat Matthews DE, Geissler WB (1994) Arthroscopic suture fixation of displaced tibial eminence fractures. Arthroscopy 10:418–423PubMedCrossRef Matthews DE, Geissler WB (1994) Arthroscopic suture fixation of displaced tibial eminence fractures. Arthroscopy 10:418–423PubMedCrossRef
12.
Zurück zum Zitat Meyers MH, McKeever FM (1959) Fracture of the intercondylar eminence of the tibia. J Bone Joint Surg Am 41-A:209–220PubMed Meyers MH, McKeever FM (1959) Fracture of the intercondylar eminence of the tibia. J Bone Joint Surg Am 41-A:209–220PubMed
13.
Zurück zum Zitat Meyers MH, McKeever FM (1970) Fracture of the intercondylar eminence of the tibia. J Bone Joint Surg Am 52:1677–1684PubMed Meyers MH, McKeever FM (1970) Fracture of the intercondylar eminence of the tibia. J Bone Joint Surg Am 52:1677–1684PubMed
14.
Zurück zum Zitat Oohashi Y (2001) A simple technique for arthroscopic suture fixation of displaced fracture of the intercondylar eminence of the tibia using folded surgical steels. Arthroscopy 17:1007–1011PubMedCrossRef Oohashi Y (2001) A simple technique for arthroscopic suture fixation of displaced fracture of the intercondylar eminence of the tibia using folded surgical steels. Arthroscopy 17:1007–1011PubMedCrossRef
15.
Zurück zum Zitat Osti L, Merlo F, Liu SH, Bocchi L (2000) A simple modified arthroscopic procedure for fixation of displaced tibial eminence fractures. Arthroscopy 16:379–382PubMedCrossRef Osti L, Merlo F, Liu SH, Bocchi L (2000) A simple modified arthroscopic procedure for fixation of displaced tibial eminence fractures. Arthroscopy 16:379–382PubMedCrossRef
16.
Zurück zum Zitat Reynders P, Reynders K, Broos P (2002) Pediatric and adolescent tibial eminence fractures: arthroscopic cannulated screw fixation. J Trauma 53:49–54PubMedCrossRef Reynders P, Reynders K, Broos P (2002) Pediatric and adolescent tibial eminence fractures: arthroscopic cannulated screw fixation. J Trauma 53:49–54PubMedCrossRef
17.
Zurück zum Zitat Senekovic V, Veselko M (2003) Anterograde arthroscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results. Arthroscopy 19:54–61PubMedCrossRef Senekovic V, Veselko M (2003) Anterograde arthroscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results. Arthroscopy 19:54–61PubMedCrossRef
18.
Zurück zum Zitat Tsukada H, Ishibashi Y, Tsuda E, Hiraga Y, Toh S (2005) A biomechanical comparison of repair techniques for anterior cruciate ligament tibial avulsion fracture under cyclic loading. Arthroscopy 21:1197–1201PubMedCrossRef Tsukada H, Ishibashi Y, Tsuda E, Hiraga Y, Toh S (2005) A biomechanical comparison of repair techniques for anterior cruciate ligament tibial avulsion fracture under cyclic loading. Arthroscopy 21:1197–1201PubMedCrossRef
19.
Zurück zum Zitat van Oostveen DP, Schild FJ, van Haeff MJ, Saris DB (2006) Suture anchors are superior to transglenoid sutures in arthroscopic shoulder stabilization. Arthroscopy 22:1290–1297PubMedCrossRef van Oostveen DP, Schild FJ, van Haeff MJ, Saris DB (2006) Suture anchors are superior to transglenoid sutures in arthroscopic shoulder stabilization. Arthroscopy 22:1290–1297PubMedCrossRef
20.
Zurück zum Zitat Yip DK, Wong JW, Chien EP, Chan CF (2001) Modified arthroscopic suture fixation of displaced tibial eminence fractures using a suture loop transporter. Arthroscopy 17:101–106PubMedCrossRef Yip DK, Wong JW, Chien EP, Chan CF (2001) Modified arthroscopic suture fixation of displaced tibial eminence fractures using a suture loop transporter. Arthroscopy 17:101–106PubMedCrossRef
21.
Zurück zum Zitat Zaricznyj B (1977) Avulsion fracture of the tibial eminence: treatment by open reduction and pinning. J Bone Joint Surg Am 59:1111–1114PubMed Zaricznyj B (1977) Avulsion fracture of the tibial eminence: treatment by open reduction and pinning. J Bone Joint Surg Am 59:1111–1114PubMed
Metadaten
Titel
Arthroscopic fixation of anterior cruciate ligament tibial avulsion fractures using bioabsorbable suture anchors
verfasst von
Yong In
Jung-Man Kim
Young-Kyun Woo
Nam-Yong Choi
Chan-Woong Moon
Min-Woo Kim
Publikationsdatum
01.03.2008
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2008
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-007-0466-x

Weitere Artikel der Ausgabe 3/2008

Knee Surgery, Sports Traumatology, Arthroscopy 3/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.