Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2015

01.11.2015 | Knee

Assessing joint line positions by means of the contralateral knee: a new approach for planning knee revision surgery?

verfasst von: Günther Maderbacher, Armin Keshmiri, Florian Zeman, Joachim Grifka, Clemens Baier

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 11/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Reconstructing the natural joint line in knee revision surgery improves clinical and functional outcome but may be challenging when both cartilage and bone were removed during previous operations. Assessing joint lines (JLs) by means of bony landmarks is inadvisable because of large variations in human anatomy. Because of the inherent symmetry of the human body, we hypothesised that JLs may be directly assessed by measuring the distances from the bony landmarks to the JL of the contralateral knee by means of radiographic images.

Methods

Using scaled weight-bearing radiographs in anteroposterior view of both knees, two independent observers measured the distances from the fibular head, the medial and lateral epicondyle, and the adductor tubercle to the JL. A two-sided p value of ≤0.05 was considered statistically significant.

Results

Two hundred knees of 100 patients (50 men and 50 women) were examined. For the fibular head, the mean difference between the treated and the control knee was 0.0 mm with narrow confidence limits ranging from −1.1 to 1.1.

Conclusion

As a new assessment method, we have suggested to assess the JL by means of radiographs of the contralateral knee. The most precise parameter was found to be the distance between the fibular head and the JL. The level of arthritis, age, gender, visibility of the landmarks, and misalignment did not influence measurement accuracy. This parameter is the first tibia-related landmark for assessing the JL, which advantageously corresponds to the tibia-first technique in revision surgery.

Level of evidence

Diagnostic Study, Level II.
Literatur
1.
Zurück zum Zitat Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470:45–53PubMedCentralCrossRefPubMed Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470:45–53PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Figgie HE III, Goldberg VM, Heiple KG, Moller HS III, Gordon NH (1986) The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am 68:1035–1040PubMed Figgie HE III, Goldberg VM, Heiple KG, Moller HS III, Gordon NH (1986) The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am 68:1035–1040PubMed
3.
Zurück zum Zitat Havet E, Gabrion A, Leiber-Wackenheim F, Vernois J, Olory B, Mertl P (2007) Radiological study of the knee joint line position measured from the fibular head and proximal tibial landmarks. Surg Radiol Anat 29:285–289CrossRefPubMed Havet E, Gabrion A, Leiber-Wackenheim F, Vernois J, Olory B, Mertl P (2007) Radiological study of the knee joint line position measured from the fibular head and proximal tibial landmarks. Surg Radiol Anat 29:285–289CrossRefPubMed
4.
Zurück zum Zitat Iacono F, Lo Presti M, Bruni D, Raspugli GF, Bignozzi S, Sharma B, Marcacci M (2013) The adductor tubercle: a reliable landmark for analysing the level of the femorotibial joint line. Knee Surg Sports Traumatol Arthrosc 21:2725–2729CrossRefPubMed Iacono F, Lo Presti M, Bruni D, Raspugli GF, Bignozzi S, Sharma B, Marcacci M (2013) The adductor tubercle: a reliable landmark for analysing the level of the femorotibial joint line. Knee Surg Sports Traumatol Arthrosc 21:2725–2729CrossRefPubMed
5.
Zurück zum Zitat Jenny JY, Boeri C (2004) Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77CrossRefPubMed Jenny JY, Boeri C (2004) Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77CrossRefPubMed
7.
Zurück zum Zitat Kerens B, Boonen B, Schotanus M, Kort N (2013) Patient-specific guide for revision of medial unicondylar knee arthroplasty to total knee arthroplasty: beneficial first results of a new operating technique performed on 10 patients. Acta Orthop 84:165–169PubMedCentralCrossRefPubMed Kerens B, Boonen B, Schotanus M, Kort N (2013) Patient-specific guide for revision of medial unicondylar knee arthroplasty to total knee arthroplasty: beneficial first results of a new operating technique performed on 10 patients. Acta Orthop 84:165–169PubMedCentralCrossRefPubMed
8.
Zurück zum Zitat Laskin RS (2002) Joint line position restoration during revision total knee replacement. Clin Orthop Relat Res 404:169–171CrossRefPubMed Laskin RS (2002) Joint line position restoration during revision total knee replacement. Clin Orthop Relat Res 404:169–171CrossRefPubMed
9.
Zurück zum Zitat Maderbacher G, Keshmiri A, Schaumburger J, Springorum HR, Zeman F, Grifka J, Baier C (2014) Accuracy of bony landmarks for restoring the natural joint line in revision knee surgery: an MRI study. Int Orthop 38:1173–1181PubMedCentralCrossRefPubMed Maderbacher G, Keshmiri A, Schaumburger J, Springorum HR, Zeman F, Grifka J, Baier C (2014) Accuracy of bony landmarks for restoring the natural joint line in revision knee surgery: an MRI study. Int Orthop 38:1173–1181PubMedCentralCrossRefPubMed
10.
Zurück zum Zitat Martin JW, Whiteside LA (1990) The influence of joint line position on knee stability after condylar knee arthroplasty. Clin Orthop Relat Res 259:146–156PubMed Martin JW, Whiteside LA (1990) The influence of joint line position on knee stability after condylar knee arthroplasty. Clin Orthop Relat Res 259:146–156PubMed
11.
Zurück zum Zitat Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lowerextremity. J Bone Joint Surg Am 69:745–749PubMed Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lowerextremity. J Bone Joint Surg Am 69:745–749PubMed
12.
Zurück zum Zitat Partington PF, Sawhney J, Rorabeck CH et al (1999) Joint line restoration after revision total knee arthroplasty. Clin Orthop Relat Res 367:165–171CrossRefPubMed Partington PF, Sawhney J, Rorabeck CH et al (1999) Joint line restoration after revision total knee arthroplasty. Clin Orthop Relat Res 367:165–171CrossRefPubMed
13.
Zurück zum Zitat Reising K, Strohm PC, Hauschild O, Schmal H, Khattab M, Südkamp NP, Niemeyer P (2013) Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique. Knee Surg Sports Traumatol Arthrosc 21:181–189CrossRefPubMed Reising K, Strohm PC, Hauschild O, Schmal H, Khattab M, Südkamp NP, Niemeyer P (2013) Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique. Knee Surg Sports Traumatol Arthrosc 21:181–189CrossRefPubMed
14.
Zurück zum Zitat Romero J, Seifert B, Reinhardt O, Ziegler O, Kessler O (2010) A useful radiologic method for preoperative joint-line determination in revision total knee arthroplasty. Clin Orthop Relat Res 468:1279–1283PubMedCentralCrossRefPubMed Romero J, Seifert B, Reinhardt O, Ziegler O, Kessler O (2010) A useful radiologic method for preoperative joint-line determination in revision total knee arthroplasty. Clin Orthop Relat Res 468:1279–1283PubMedCentralCrossRefPubMed
15.
Zurück zum Zitat Servien E, Viskontas D, Giuffre BM, Coolican MRJ, Parker DA (2008) Reliability of bony landmarks for restoration of the joint line in revision knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:263–269CrossRefPubMed Servien E, Viskontas D, Giuffre BM, Coolican MRJ, Parker DA (2008) Reliability of bony landmarks for restoration of the joint line in revision knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:263–269CrossRefPubMed
16.
Zurück zum Zitat Singerman R, Davy DT, Goldberg VM (1994) Effects of patella alta and patella infera on patellofemoral forces. J Biomech 27:1059–1065CrossRefPubMed Singerman R, Davy DT, Goldberg VM (1994) Effects of patella alta and patella infera on patellofemoral forces. J Biomech 27:1059–1065CrossRefPubMed
17.
Zurück zum Zitat Singerman R, Heiple KG, Davy DT et al (1995) Effect of tibial component position on patellar strain following total knee arthroplasty. J Arthroplast 10:651–656CrossRef Singerman R, Heiple KG, Davy DT et al (1995) Effect of tibial component position on patellar strain following total knee arthroplasty. J Arthroplast 10:651–656CrossRef
18.
Zurück zum Zitat Yau WP, Leung A, Liu KG, Yan CH, Wong LL, Chiu KY (2007) Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty. J Arthroplast 22:1150–1161CrossRef Yau WP, Leung A, Liu KG, Yan CH, Wong LL, Chiu KY (2007) Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty. J Arthroplast 22:1150–1161CrossRef
Metadaten
Titel
Assessing joint line positions by means of the contralateral knee: a new approach for planning knee revision surgery?
verfasst von
Günther Maderbacher
Armin Keshmiri
Florian Zeman
Joachim Grifka
Clemens Baier
Publikationsdatum
01.11.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 11/2015
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-3157-4

Weitere Artikel der Ausgabe 11/2015

Knee Surgery, Sports Traumatology, Arthroscopy 11/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.