Bleeding complications during cardiac electronic device implantation in patients receiving antithrombotic therapy: is there any value of local tranexamic acid?

verfasst von: Osman Beton, Ersin Saricam, Hakki Kaya, Hasan Yucel, Orhan Dogdu, Okan Onur Turgut, Ocal Berkan, Izzet Tandogan, Mehmet Birhan Yilmaz

Erschienen in: BMC Cardiovascular Disorders | Ausgabe 1/2016

Abstract

Background

The perioperative use of antithrombotic therapy is associated with increased bleeding risk after cardiac implantable electronic device (CIED) implantation. Topical application of tranexamic acid (TXA) is effective in reducing bleeding complications after various surgical operations. However, there is no information regarding local TXA application during CIED procedures. The purpose of our study was to evaluate bleeding complications rates during CIED implantation with and without topical TXA use in patients receiving antithrombotic treatment.

Methods

We conducted a retrospective analysis of consecutive patients undergoing CIED implantation while receiving warfarin or dual antiplatelet (DAPT) or warfarin plus DAPT treatment. Study population was classified in two groups according to presence or absence of topical TXA use during CIED implantation. Pocket hematoma (PH), major bleeding complications (MBC) and thromboembolic events occuring within 90 days were compared.

Results

A total of 135 consecutive patients were identified and included in the analysis. The mean age was 60 ± 11 years old. Topical TXA application during implantation was reported in 52 patients (TXA group). The remaining 83 patients were assigned to the control group. PH occurred in 7.7 % patients in the TXA group and 26.5 % patients in the control group (P = 0.013). The MBC was reported in 5.8 % patients in the TXA and 20.5 % patients in control group (P = 0.024). Univariate logistic regression analysis identified age, history of recent stent implantation, periprocedural spironolactone use, periprocedural warfarin use, perioperative warfarin plus DAPT use, cardiac resynchronization therapy, and topical TXA application during CIED implantation as predicting factors of PH. Multivariate analysis showed that perioperative warfarin plus DAPT use (OR = 10.874, 95 % CI: 2.496–47.365, P = 0.001) and topical TXA application during CIED procedure (OR = 0.059, 95 % CI: 0.012–0.300, P = 0.001) were independent predictors of PH. Perioperative warfarin plus DAPT use and topical TXA application were also found to be independent predictors of MBC in multivariate analyses. No thromboembolic complications was recorded in the study group.

Conclusion

The present study demonstrated that the topical TXA application during CIED implantation is associated with reduced PH and MBC in patients with high bleeding risk.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​s12872-016-0251-1) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

OB conceived of the study, and participated in its design and coordination and wrote the manuscript, and carried out device implantation procedures. ES carried out device implantation procedures, participated in the study design and helped in collection of data, and revised the manuscript critically for important intellectual content. HK carried out device implantation procedures, participated in its design and collection of data, helped to draft the manuscript and revised the manuscript critically for important intellectual content. HY carried out device implantation procedures, participated in its design and collection of data, help to draft the manuscript and revised the manuscript critically for important intellectual content. OD participated in the design of the study and performed statistical analyses, helped to draft the manuscript, revised the manuscript critically for important intellectual content. OT carried out device implantation procedures, participated in the study design and coordination and helped in collection of data, and revised the manuscript critically for important intellectual content. OB gave the idea of topical tranexamic acid use in high bleeding risk patients undergoing CIED implantation, conceived of the study, and participated in its design and coordination, and revised the manuscript critically for important intellectual content. IT carried out device implantation procedures, participated in its design and coordination, helped to draft the manuscript, helped in collection of data and vised the manuscript critically for important intellectual content. MBY participated in its design and coordination, performed statistical analyses, helped to draft the manuscript, and revised the manuscript critically for important intellectual content. All authors read and approved the final manuscript.
Abkürzungen
CIED
cardiac implantable electronic device
CRT-D
cardiac resynchronization therapy-defibrillator
CRT-P
cardiac resynchronization therapy-pacemaker
DAPT
dual antiplatelet treatment
ICD
implantable cardioverter defibrillators
INR
international normalization ratio
LV
left ventricular
MBC
major bleeding complications
PH
pocket hematoma
RBC
red blood cell
TXA
tranexamic acid

Background

The number of cardiac implantable electronic device (CIED) implantation has increased considerably in the last decade [1] and has been continuing to increase parallel to expanded indications in the most recent guidelines [2, 3]. As a result, numerous patients have undergone CIED implantation while receiving antithrombotic therapy for few years [4]. Perioperative management of these patients is very challenging with a high risk of bleeding [5]. Pocket hematoma is relatively common complication (reported rates between 2 % and 5 %) [68], and dual antiplatelet therapy (DAPT) increases the risk fivefold [6], and furthermore rate of bleeding complication can be as high as 40 % with triple therapy [9].
In the presence of moderate or high thromboembolic risk, physicians usually accept the risk of bleeding and continue the antithrombotic therapy perioperatively. It is clearly known that postoperative bleeding complications constitutes not only financial but also significant medical burden. Several experience based strategies are available to reduce the incidence of pocket hematoma: meticulous use of cautery, tamponade of pocket with gauze during lead implantation, wound drainage, pressure bandage and hemostatic use. Also, some hemostatic agents were found to be ineffective in preventing pocket hematoma, besides increasing the risk of pocket infection [10]. Also, these agents are not available in every clinic, need time to be prepared and all increases the cost.
Tranexamic acid (TXA) is a synthetic antifibrinolytic agent that binds to the lysine binding site of plasminogen and blocks its binding to fibrin surface [11]. Topical application of TXA is effective in reducing bleeding complications after various surgical operations [11]. However, there is no information regarding local TXA application during CIED procedures. The purpose of our study was to evaluate bleeding complications rates during CIED implantation with and without topical TXA use in patients receiving antithrombotic treatment.

Methods

Study cohort

We conducted a retrospective analysis of consecutive patients undergoing CIED implantation while receiving antithrombotic therapy, namely, warfarin or warfarin plus DAPT or DAPT. Between June 2011 and February 2015, 989 consecutive patients who underwent CIED procedures at Cumhuriyet University Hospital, Sivas, Turkey and Cag Hospital, Ankara, Turkey were considered. At index procedure, a total of 319 patients were on chronic background therapy with warfarin or warfarin plus DAPT or DAPT. Indication of DAPT consisting of combination of acetylsalicylic acid and clopidogrel was recent stent implantation (within 3–12 months) in all patients receiving DAPT. Exclusion criteria were: use of other antiplatelets (e.g. prasugrel, ticagrelor, ticlopidine), heparin bridging strategy, interrupted antiplatelet therapy more than 2 days before the procedure, unknown international normalization ratio (INR) or INR values inconsistent with target range at the day of procedure, periprocedural bleeding not related to CIED procedure (eg, gastrointestinal bleeding, hematuria, etc.), lead extraction with laser or mechanical dilator (As a protocol, all antithrombotic drugs have been discontinued at least 7 days prior to this procedure in both clinics). Inclusion criteria were one of the below strategies for perioperative antithrombotic management:
  • Uninterrupted warfarin; Warfarin therapy was continued to maintain INR in the therapeutic range (2.0–3.5), but dosage of warfarin was adjusted to maintain INR between 1.9 and 2.5 at the day of procedure.
  • Uninterrupted warfarin plus DAPT; In addition to uninterrupted warfarin strategy, aspirin and/or clopidogrel was continued perioperatively without dose skipping more than 2 days before the procedure.
  • Uninterrupted DAPT; Aspirin and/or clopidogrel was continued perioperatively without dose skipping more than 2 days before the procedure.
Hospital records were reviewed to determine medications at admission and during perioperative period. Patients were grouped according to antithrombotic medications at admission (Fig. 1, top and bottom). A protocol for topical utilization of TXA during CIED implantations was proposed for the high risk patients at Cumhuriyet University by August 2013 up on several discussions of Heart Team and advised to Cag Hospital as well and the protocol has been routinely used in both hospital since August 2013. Hence, TXA group consisted of patients who underwent CIED procedure after August 2013 (between August 2013 and February 2015) and the control group consisted of patients who underwent CIED procedure before August 2013 (between June 2011- July 2013). The study was approved by the Ethics Committee of the Faculty of Medicine, Firat University (reference number: 201602/06) and conducted in accordance with the Helsinki Declaration.

Definitions

Procedure related bleeding complications was recorded as pocket hematoma and major bleeding complications (MBC). Pocket hematoma (PH) was defined as swelling and a painful mass with ecchymosis formation extending the margin of generators.
MBC defined as any CIED procedure related bleeding leading to red blood cell (RBC) transfusion, surgical intervention for pocket evacuation or revision, pericardial effusion, hemothorax, or life-threatening bleed [6]. If a patient experienced multiple MBC, the clinical time course was reviewed to ensure that complications counted were distinctly separate events related to the CIED procedure.
Thromboembolic events were defined as transient ischemic attack, stroke, myocardial infarction, systemic embolism, mechanical valve thrombosis, deep vein thrombosis, and pulmonary embolism.

Implantation techniques

All procedures were performed by experienced cardiologists, blinded to study plan. All of the implanting physicians had an experience of at least 150 operations per annum with a similar experience in years (>3 years). All the patients were administered intravenous prophylactic antibiotics (mostly cefazolin, a first generation cephalosporin) per hospital protocol. After administration of local anesthesia (lidocaine or prilocaine hydrochloride), an incision was made in the prepectoral region and a subcutaneous or submuscular pocket was formed according to device and subcutaneous tissue features of the patient. Electro cautery ± ligatures were routinely used to obtain complete surgical hemostasis. All the leads were implanted via sublavian/axillary venous puncture (one puncture per lead) or cephalic cut-down. Right ventricular leads were usually targeted to the interventricular septum of right ventricle. The left ventricular leads were inserted through the coronary sinus. After lead measurements with analyzer, leads were sutured using nonabsorbable silk sutures at the venous site. Generators were placed in preformed pocket and were sutured using nonabsorbable silk sutures. The incision was closed in three layers using absorbable sutures, and a sterile pressure dressing was applied. Implantation technique were same for all patients except additional local TXA application in TXA group.

Utilization of topical transexamic acid during implantation

According to our protocol, after pocket formation and complete surgical hemostasis with electrocoutery ± surgical ligation, pocket and the incision sites were washed with 500 mg/5 ml TXA without removing with suction. Then, a standard gauze soaked in 5 ml solution containing 500 mg of TXA was placed in the prepared pocket, and steady and direct pressure by using the palm of one hand was applied on the gauze from the skin for 1–3 min. The gauze was left in the pocket throughout the procedure and was removed from the pocket before the device placement in the pocket. Lastly, pocket and incision sites were washed with 500 mg/5 ml TXA just before incision closure without removing with suction.
All the cardiologists performing CIED implantation have known the topical TXA protocol well (experience of at least 15 implantations with TXA). All details about the procedure was routinely documented by the attending cardiologist and it was recorded both in computer based system and patient’s CIED file.

Postoperative care and data collection

A pressure dressing was applied to the wound for 24–36 h. A chest X-ray was obtained after the procedure. Intravenous antibiotics and oral or iv pain medications (mostly asetaminofen) were given for 1–3 days. All cardiac medications were continued. Patients were discharged at third day after the procedure. All patients were evaluated at discharge and 7, 15, 30 and 90 days after the procedure to access wound and suture integrity, pocket hematoma, thromboembolic events, CIED functions, device infection, or other problems in outpatient outpatient cardiology clinic and findings were recorded in patient’s CIED file.
Data were retrospectively collected from patient’s file, medical observations and computer based database system. In addition to usual patient characteristics, the following information were collected: all medications, technical surgical details and laboratory data.

Statistical analysis

Continuous variables were expressed as mean ± standard deviation or median (min-max) in the presence of abnormal distribution, and categorical variables as percentages. Comparisons between groups of patients were made by use of a χ2 test for categorical variables, independent samples t test for normally distributed continuous variables, and Mann-Whitney U test when the distribution was skewed. We used univariate logistic regression analysis to quantify the association of variables with occurrence major bleeding and PH. Age, presence of LV thrombus, history of recent stent implantation, spironolactone use, periprocedural warfarin use, periprocedural warfarin plus DAPT use, ICD device implantation, three lead implantation, and topical TXA use during CIED implantation were entered into the multivariate logistic regression model for determining the independent predictors of PH. Hypertension, history of recent stent implantation, spironolactone use, periprocedural warfarin use, periprocedural warfarin plus DAPT use, and topical TXA use during implantation were entered into the multivariate logistic regression model in order to determine the independent predictors of MBC. All statistical procedures were performed using SPSS software version 14.0 (SPSS Inc., Chicago, IL). A p value of 0.05 was considered as statistically significant.

Results

Study population

A total of 135 consecutive patients were identified and included in the present analysis. Topical TXA use was noted in 52 patients during implantation the remaining 83 patients were assigned to be as control group that included traditional routine precautions in these high risk patients. The mean age was 60 ± 11 years with 81 (60 %) males. Baseline characteristics of the study population are presented in Table 1 and all variables were statistically similar between the groups. Procedure related characteristics of the study population are presented in Table 2. There was no difference between the groups according to these variables.
Table 1
Baseline characteristics of study population
Variables
All patients (n = 135)
Tranexamic acid (n = 52)
Control (n = 83)
P-value
Age (years)
60 ± 11
62 ± 10
59 ± 11
0.101
Male, n (%)
81 (60)
32 (61.5)
46 (59)
0.773
Body mass index (kg/m2)
25.4 ± 4.6
24.8 ± 4.0
25.8 ± 5.0
0.215
Smoking, n (%)
22 (16.3)
9 (17.3)
13 (15.7)
0.990
Hypertension, n (%)
74 (54.8)
29 (55.8)
45 (54.2)
0.860
Diabetes mellitus, n (%)
46 (34.1)
17 (32.7)
29 (34.9)
0.789
Previous CABG, n (%)
43 (31.9)
18 (34.6)
25 (30.1)
0.585
Ejection fraction, %
34 (20–55)
34 (20–55)
34 (20–55)
0.910
COPD, n (%)
19 (14.1)
9 (17.3)
10 (12.0)
0.548
Hemoglobin, g/dL
12.8 (9.5–15.1)
12.9 (9.5–14.5)
12.8 (9.5–15.1)
0.989
Platelet count, K/mm3
244 ± 57
240 ± 56
247 ± 58
0.476
BUN, mg/dL
30.6 (22–45)
30.6 (25–43)
30.6 (22–45)
0.926
Creatinine, mg/dL
1.1 ± 0.4
1.0 ± 0.4
1.1 ± 0.4
0.447
Atrial fibrillation, n (%)
43 (31.9)
22 (42.3)
21 (25.3)
0.039
Metallic prosthetic valve, n (%)
54 (40.0)
20 (38.5)
34 (41.0)
0.773
LV thrombus, n (%)
9 (6.7)
6 (11.5)
3 (3.6)
0.087
Recent stent implantation, n (%)
63 (46.7)
27 (51.9)
36 (43.4)
0.333
Medications
ACEI/ARB, n (%)
95 (70.4)
36 (69.2)
59 (71.1)
0.818
Beta blocker, n (%)
112 (83)
43 (82.7)
69 (83.1)
1.0
Diuretic, n (%)
99 (73.3)
37 (71.2)
62 (74.7)
0.800
Spironolactone, n (%)
67 (49.6)
25 (48.1)
42 (50.6)
0.775
Statin, n (%)
62 (45.9)
24 (46.2)
38 (45.8)
0.966
Warfarin, n (%)
72 (53.3)
25 (48.1)
47 (56.6)
0,333
DAPT, n (%)
37 (27.4)
16 (30.8)
21 (25.3)
0.621
Warfarin plus DAPT, n (%)
26 (19.3)
11 (21.2)
15 (18.3)
0.828
ACEI angiotensin converting enzyme inhibitors, ARB angiotensin receptor blockers, BUN blood urea nitrogen, CABG coronary artery bypass graft, COPD chronic obstructive pulmonary disease, DAPT dual antiplatelet therapy, LV left ventricular
Table 2
Procedure related characteristics between the tranexamic acid and control groups
Characteristic
All patients (n = 135)
Tranexamic acid (n = 52)
Control (n = 83)
P-value
INR at the day of implanta
2.1 (1.9–2.5)
2.1(1.9–2.5)
2.1(1.9–2.5)
0.932
Generator exchange and/or pocket revision, n (%)
14 (10.4)
5 (9.6)
9 (10.8)
0.968
New implantation, n (%)
101 (74.8)
39 (75.0)
62 (74.7)
1.0
Upgrade and/or lead revision, n (%)
20 (14.8)
8 (15.4)
12 (14.5)
1.0
Pacemaker, n (%)
24 (17.8)
9 (17.3)
15 (18.1)
1.0
ICD, n (%)
111 (83)
43 (82.7)
68 (81.9)
 
Number of leads implanted
 One, n (%)
26 (19.3)
12 (23.1)
14 (16.9)
0.505
 Two, n (%)
50 (37.0)
18 (34.6)
32 (38.6)
0.645
 Three, n (%)
45 (33.3)
17 (32.7)
28 (33.7)
0.900
 Submuscular pocket, n (%)
5 (3.7)
2 (3.8)
3 (3.6)
1.0
Venous route other than subclavian
 Axillary, n (%)
12 (8.9)
4 (7.7)
8 (9.6)
0.767
 Cephalic, n (%)
7 (5.2)
3 (5.8)
4 (4.8)
1.0
DAPT dual antiplatelet therapy, ICD implantable cardioverter defibrillator, INR international normalized ratio
aThe median INR level of patients with warfarin continuation strategy
Procedure related complications are presented in Table 3. A total of 28 MBC events (reoperation, RBC transfusion, hemothorax, pericardial effusion, and life-threatening bleed) were reported in 20 patients (14.8 %) in the study population (Table 3). MBC occurred in 3 patients (5.8 %) in the TXA group and in 17 patients (20.5 %) in the control group (P = 0.024) (Table 3). Total counted event rates of reoperation and RBC transfusion were statistically higher in control group (9.6 % vs 0.0 %, P = 0.023 and 15.7 % vs 3.8 %, P = 0.047, respectively). PH occurred in 4 patients (7.7 %) in the TXA group and 22 patients (26.5 %) in the control group (P = 0.013). The detailed characteristics of patients with pocket hematoma and MBC are summarized in Additional file 1: Table S1.
Table 3
Procedure related complications
Complications
All patients (n = 135)
Tranexamic acid (n = 52)
Control (n = 83)
P-value
Major bleeding complications, n (%)
20 (14.8)
3 (5.8)
17 (20.5)
0.024
Reoperationa, n (%)
8 (5.9)
0 (0.0)
8 (9.6)
0.023
RBC transfusiona, n (%)
15 (11.1)
2 (3.8)
13 (15.7)
0.047
Hemothoraxa, n (%)
1 (0.7)
0 (0.0)
1 (1.2)
1.0
Pericardial effusiona, n (%)
3 (2.2)
1 (1.9)
2 (2.4)
1.0
Life-threatening bleeda, n (%)
1 (0.7)
0 (0.0)
1 (1.2)
1.0
Pocket hematoma, n (%)
26 (19.3)
4 (7.7)
22 (26.5)
0.013
Pocket related infection, n (%)
1 (0.7)
0 (0.0)
1 (1.2)
1.0
Pneumothorax, n (%)
2 (1.4)
1 (1.9)
1 (1.2)
1.0
RBC red blood cells. aCounted events were presented (If a patient experienced multiple major bleeding complications, the clinical time course was reviewed to ensure that complications counted were distinctly separate events related to the procedure)
One pocket related infections (after hematoma evacuation procedure) requiring full system extraction was reported in control group. Pneumothorax was occurred in 2 patients (one in control group and 1 in TXA group, and chest tube drainage was required for both). One patient (78 years old male patient receiving periprocedural DAPT) died after implantation because of complicating hemathorax and large pericardial effusion in the control group. Two patients had pericardial effusion which required pericardiosynthesis. No thromboembolic complications were occurred in the study group perioperatively and 90 days after the procedure.

Predictors of pocket hematoma

Baseline characteristics of the study population according to presence and absence of PH are presented in Table 4. Mean age was statistically higher in PH positive group (n = 26) compared to PH negative group (n = 109) (64 ± 12 vs 59 ± 11, P = 0.037). More patients had history of recent stent implantation in PH positive group (88.5 % vs 36.7 %, P < 0.001). Periprocedural warfarin plus DAPT and spironolactone use were higher in PH positive group compared to PH negative (57.7 % vs 10.1 %, P < 0.001 and 73.1 % vs 44.0 %, P = 0.015, respectively). Periprocedural warfarin use was higher in PH negative group (62.4 % vs 15.4 %, P < 0.001) (Table 4).
Table 4
Baseline characteristics according to pocket hematoma
Variables
PH positive group (n = 26)
PH negative group (n = 109)
P-value
Age
64 ± 12
59 ± 11
0.037
Male, n (%)
14 (53.8)
67 (61.5)
0.624
Body mass index (kg/m2)
26.1 ± 5.7
25.3 ± 4.3
0.396
Smoking, n (%)
3 (11.5)
19 (17.4)
0.567
Hypertension, n (%)
18 (69.2)
56 (51.4)
0.154
Diabetes mellitus, n (%)
7 (26.9)
39 (35.8)
0.531
Previous CABG, n (%)
9 (34.6)
34 (31.2)
0.918
Ejection fraction, %
32 (25–55)
34 (20–55)
0.210
COPD, n (%)
3 (11.5)
16 (14.7)
1.0
Hemoglobin, g/dL
13.2 (10.8–15.1)
12.8 (9.5–14.5)
0.946
Platelet count, K/mm3
239 ± 69
246 ± 55
0.630
BUN, mg/dL
30.2 (25–39)
31.6 (22–45)
0.975
Creatinine, mg/dL
1.0 ± 0.4
1.1 ± 0.4
0.614
Atrial fibrillation, n (%)
10 (38.5)
33 (30.3)
0.568
Metallic prosthetic valve, n (%)
11 (42.3)
43 (39.4)
0.964
LV thrombus, n (%)
4 (15.4)
5 (4.6)
0.069
Recent stent implantation, n (%)
23 (88.5)
40 (36.7)
<0.001
Medications
ACEI/ARB, n (%)
22 (84.6)
73 (67.0)
0.126
Beta blocker, n (%)
24 (92.3)
88 (80.7)
0.245
Diuretic, n (%)
21 (80.8)
78 (71.6)
0.479
Spironolactone, n (%)
19 (73.1)
48 (44.0)
0.015
Statin, n (%)
13 (50.0)
49 (45.0)
0.807
Warfarin, n (%)
4 (15.4)
68 (62.4)
<0.001
DAPT, n (%)
7 (26.9)
30 (27.5)
1.0
Warfarin plus DAPT, n (%)
15 (57.7)
11 (10.1)
<0.001
ACEI angiotensin converting enzyme inhibitors, ARB angiotensin receptor blockers, BUN blood urea nitrogen, CABG coronary artery bypass graft, COPD chronic obstructive pulmonary disease, DAPT dual antiplatelet therapy, LV left ventricular, PH pocket hematoma
Procedure related characteristics of the study population according to PH are presented in Table 5. More ICD devices were implanted in PH positive group compared to PH negative group (96.2 % vs 78.9 %, P = 0.045). The topical TXA use during CIED implantation was higher in MBC negative group compared to MBC positive group (44.0 % vs 15.4 %, P = 0.013).
Table 5
Procedure related characteristics according to pocket hematoma
Characteristics
PH positive group (n = 26)
PH negative group (n = 109)
P-value
INR at the day of implanta
2.1 (2.0–2.5)
2.0 (1.9–2.5)
0.122
Generator exchange and/or pocket revision, n (%)
3 (11.5)
11 (10.1)
1.0
New implantation, n (%)
19 (73.1)
82 (75.2)
1.0
Upgrade and/or lead revision, n (%)
4 (15.4)
16 (14.7)
1.0
Pacemaker, n (%)
1 (3.8)
23 (21.1)
0.045
ICD, n (%)
25 (96.2)
86 (78.9)
 
Number of leads implanted
 One, n (%)
2 (7.7)
24 (22.0)
0.165
 Two, n (%)
8 (30.8)
42 (38.5)
0.610
 Three, n (%)
13 (50.0)
32 (29.4)
0.076
 Submuscular pocket, n (%)
1 (3.8)
4 (3.7)
1.0
Venous route other than subclavian
 Axillary, n (%)
3 (11.5)
9 (8.3)
0.700
 Cephalic, n (%)
2 (7.7)
5 (4.6)
0.620
 Local tranexamic acid use
4 (15.4)
48 (44.0)
0.013
DAPT dual antiplatelet therapy, ICD implantable cardioverter defibrillator, INR international normalized ratio, PH Pocket hematoma. a The median INR level of patients with warfarin continuation strategy
Results of univariate and multivariate analyses for prediction of PH occurrence are presented in Table 6. In the study group, univariate analyses identified seven predictors of PH: age (OR = 1.043, 95 % CI: 1.002–1.085, P = 0.040), history of recent stent implantation (OR = 13.225, 95 % CI: 3.734–46.839, P < 0.001), periprocedural spironolactone use (OR = 3.449, 95 % CI: 1.340–8.879, P = 0.010), periprocedural warfarin use (OR = 0.110, 95 % CI: 0.035–0.341, P < 0.001), perioperative warfarin plus DAPT use (OR = 12.149, 95 % CI: 4.483–32.920, P < 0.001), three lead implantation during procedure (OR = 2.406, 95 % CI: 1.006–5.757, P = 0.049), and topical TXA application during CIED implantation (OR 0.231, 95 % CI: 0.075–0.716, P = 0.011). Multivariate analysis of factors with P < 0.1 in univariate analysis showed that perioperative warfarin plus DAPT use (OR = 10.874, 95 % CI: 2.496–47.365, P = 0.001) and topical TXA application during CIED procedure (OR = 0.059, 95 % CI: 0.012–0.300, P = 0.001) were independent predictors of MBC.
Table 6
Univariate and multivariate predictors of pocket hematoma
 
Univariate
Multivariate
Variables
OR
95 % CI
P-value
OR
95 % CI
P-value
Age
1.043
1.002–1.085
0.040
   
Presence of LV thrombus
3.782
0.939–15.228
0.061
   
History of recent stent implantation
13.225
3.734–46.839
<0.001
   
Spironolactone use
3.449
1.340–8.879
0.010
   
Periprocedural warfarin use
0.110
0.035–0.341
<0.001
   
Periprocedural warfarin plus DAPT use
12.149
4.483–32.920
<0.001
10.874
2.496–47.365
0.001
ICD device
6.686
0.860–51.991
0.069
   
Three lead implantation
2.406
1.006–5.757
0.049
   
Topical TXA use during CIED implantation
0.231
0.075–0.716
0.011
0.059
0.012–0.300
0.001
CI confidence interval, CIED cardiac electronic device implantation, DAPT dual antiplatelet therapy, ICD implantable cardioverter defibrillator, LV left ventricular, MBC major bleeding complications, PH pocket hematoma, TXA tranexamic acid

Predictors of major bleeding complications

In the study group, there were 20 patients with MBC (MBC positive group) and 115 without MBC (MBC negative group). Baseline characteristics of the study population according to major bleeding complications are presented in Additional file 1: Table S2. More patients had history of recent stent implantation in MBC positive group (80.0 % vs 40.9 %, P = 0.003). Periprocedural warfarin plus DAPT use was higher in MBC positive group compared to MBC negative (50.0 % vs 13.9 %, P = 0.001). Periprocedural warfarin use was higher in MBC negative group (59.1 % vs 20.0 %, P = 0.003) (Additional file 1: Table S2).
Procedure related characteristics of the study population according to MBC are presented in Additional file 1: Table S3. The topical TXA use during CIED implantation was higher in MBC negative group compared to MBC positive group (42.6 % vs 15.0 %, P = 0.036).
Results of univariate and multivariate analyses for prediction of MBC occurrence are presented in Additional file 1: Table S4. In the study group, univariate analyses identified four predictors of MBC: history of recent stent implantation (OR = 5.787, 95 % CI: 1.820–18.406, P = 0.003), periprocedural warfarin use (OR = 0.173, 95 % CI: 0.054–0.550, P = 0.003), perioperative warfarin plus DAPT use (OR = 6.187, 95 % CI: 2.224–17.216, P < 0.001), and topical TXA application during CIED implantation (OR 0.238, 95 % CI: 0.066–0.856, P = 0.028). Multivariate analysis of factors with P < 0.1 in univariate analysis showed that perioperative warfarin plus DAPT use (OR = 8.144, 95 % CI: 2.589–25.618, P < 0.001) and topical TXA application during CIED procedure (OR = 0.170, 95 % CI: 0.042–0.690, P = 0.013) were independent predictors of MBC.

Discussion

The present study retrospectively investigated the effect of additional topical TXA use during CIED procedure on PH and MBC in a population with uninterrupted antithrombotic therapy strategy. The overall rates of PH and MBC were 19.3 % and 14.8 %, respectively. The frequencies of PH and MBC were significantly higher (3.4-fold and 3.5-fold, respectively) in the control group compared to TXA group. The counted event rates of reoperation and RBC transfusion requirements were lower in TXA group. In multivariate analysis, warfarin plus DAPT was found to be an independent predictor of increased risk of PH and MBC, whereas, topical TXA application during CIED was found to be an independent predictor of decreased risk PH and MBC.
Expanding CIED implantation indications are mainly belonging to implantable cardioverter defibrillators (ICD) and mostly includes patients with ischemic heart disease [2, 3]. Some of those patients have recently undergone coronary stent implantation. Following coronary intervention the need for DAPT usually is temporally, the duration of therapy mainly depending on the type of the stent (drug eluting or bare) [5]. Shortening the initially recommended time period of DAPT is highly discouraged due to high risk of stent thrombosis [5]. Furthermore, some ICD implants should not be postponed because of a potential risk of sudden cardiac death. However, it is well known that bleeding complications occurs more frequently in patients receiving ICD than those receiving PMs. [12] In the present study, 83 % of the devices were ICD and 46.7 % of the patients had recent stent implantation.
BRUISE Control trial reported that the incidence of hematoma is 3.5 % in patients with perioperative strategy of uninterrupted warfarin group [13]. On the other hand, in the FinPAC trial, the risk of hematoma was similar in patients on aspirin (5.5 %) and warfarin (5.6 %), but 0.9 % in patients with no antithrombotic therapy [14]. The presence of wide variability among reported incidence of pocket hematoma and bleeding complications in the numerous published studies is according to different criterias used. But, bleeding complications which require serious interventions such as drainage (pocket, pericardial or pleural) or transfusion are the only practically important ones. So, both PH and MBC criterias were used for this study in coherent with expectations about practical issues.
In the present study, periprocedural antithrombotic treatment strategy was uninterrupted warfarin 53.3 % of the patients, uninterrupted DAPT in 27.4 % of the patients, and uninterrupted warfarin plus DAPT (triple therapy) in 19.3 % of the patients. Despite the high rates of periprocedural antiplatelet therapy with warfarin and ICD implantation, PH and MBC rates were relatively low in TXA group. These findings may be attributed to the topical TXA usage. According to a recent systemic review, there is reliable evidence that topical application of TXA reduces bleeding and blood transfusion in surgical patients [11]. Although bleeding from CIED surgical sites is usually controllable, there may be significant blood loss. The topical administration of TXA intraoperatively can directly target the source of bleeding and may stabilize the multiple micro-clots that form within the wound containing high capillary density [11, 15].
Following the surgical trauma, clotting cascade is activated to produce a fibrin-based clot at the location of vascular injury. Fibrinolysis begins soon after as a normal homeostatic response to restore vascular patency and to prevent positive feedback from causing clot activation throughout the vascular compartment [15, 16]. However, in the first hour after severe injury, hyperfibrinolysis can occur which can lead to further bleeding, and TXA acts to block this [15, 16]. Topical TXA may be more beneficial especially in the presence antithrombotic therapy, when capillary or venous ooze is more pronounced [17, 18]. In addition, TXA may have positive impact on platelet functions by inhibiting the conversion of plasminogen to plasmin which impairs platelet functions [18].
In the past decade, some hemostatic agents were studied in preventing pocket hematoma. A fibrin selant prior to wound closure was shown to be effective in reducing the number of pocket hematomas regardless of the anticoagulation strategy used, but it may be associated with an increased cost, viral transmission, allergic reactions to bovine proteins or infections [19]. Recently, topical application of a hemostat containing mixture of thrombin and collagen was studied in patients on anticoagulants and/or antiplatelets [10]. However, it was found that this hemostat does not decrease the frequency of clinically relevant pocket hematomas, but increase the rate of pocket infections [10]. In the present study, no allergic reaction was recorded. Also, no pocket infection was observed in topical TXA group during follow-up period. The low cost of the TXA was considered as an additional advantage in comparison with other hemostatic agents.
Similar to other studies, the present study found that history of recent stent implantation and triple therapy is associated with PH and MBC. Relationship of history of recent stent implantation with PH and MBC could be clearly attributed to DAPT usage in these pateints. Because, patients with recent stent implantation were on DAPT ± warfarin therapy in the present study population. In univariate analyses, presence of left ventricular (LV) thrombus was found to be related to increased PH risk. In the present study, all patients with LV thombus had previous history of anterior myocardial infraction and recent stent implantation, and thereby they had periprocedural uninterrupted warfarin plus DAPT strategy which was found to be independently related with PH complication. Additionally, spironolactone use and three lead implantation (which implies cardiac resynchronization therapy) during the procedure were found to be related with increased risk of PH in univariate analyses. More ICDs (especially cardiac resynchronization therapy-defibrillator [CRT-D]) were implanted in PH positive group, so the rate of spironolactone use was higher in PH positive group. Twenty (76.9 %) of the patients with PH had CRT-D implantation procedure (13 new implantation, 4 upgrade and/or lead revision, and 3 generator replacement) (Additional file 1: Table S1). This finding was consistent with other studies. In a recent review, it was stated that rates of PH is around 2.5 % in ICD implantations, >3 % in case of CRT-D or cardiac resynchronization therapy-pacemaker (CRT-P) implantation, up to 4.2 % in case of upgrading of a previous implant to CRT-P/CRT-D, and 4.3 % in case of surgical revision of the implant with repositioning due to dislocation or placement of a new lead [20].
To our knowledge, this is the first study to demonstrate that topical TXA use was associated with lower PH and MBC rates during CIED procedures of patients with uninterrupted antithrombotic therapy.

Limitations

Several limitations of this study should be acknowledged. Firstly, it was a retrospective anaylsis which is susceptible to bias in data selection. Secondly, sample size of our study was relatively small, hence, no subgroup analysis was possible. Thirdly, the volumes of the conducting centers of the present study were not enough to draw definitive conclusions rather than hypothesis generation. Hence, large scaled randomized and prospective trials are needed to access safety, efficacy and cost-effectivity of topical TXA in CIED procedures.

Conclusion

The present study demonstrated for the first time that addition of topical TXA during CIED implantation was associated with reduced PH and MBC in patients with high bleeding risk. However, further trials needed to test safety and efficacy of topical TXA application in CIED procedures.

Availability of data and materials

The datasets supporting the conclusions of this article are included within the article and its additional supplementary files.
Not applicable.

Acknowledgements

None.

Funding

None.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

OB conceived of the study, and participated in its design and coordination and wrote the manuscript, and carried out device implantation procedures. ES carried out device implantation procedures, participated in the study design and helped in collection of data, and revised the manuscript critically for important intellectual content. HK carried out device implantation procedures, participated in its design and collection of data, helped to draft the manuscript and revised the manuscript critically for important intellectual content. HY carried out device implantation procedures, participated in its design and collection of data, help to draft the manuscript and revised the manuscript critically for important intellectual content. OD participated in the design of the study and performed statistical analyses, helped to draft the manuscript, revised the manuscript critically for important intellectual content. OT carried out device implantation procedures, participated in the study design and coordination and helped in collection of data, and revised the manuscript critically for important intellectual content. OB gave the idea of topical tranexamic acid use in high bleeding risk patients undergoing CIED implantation, conceived of the study, and participated in its design and coordination, and revised the manuscript critically for important intellectual content. IT carried out device implantation procedures, participated in its design and coordination, helped to draft the manuscript, helped in collection of data and vised the manuscript critically for important intellectual content. MBY participated in its design and coordination, performed statistical analyses, helped to draft the manuscript, and revised the manuscript critically for important intellectual content. All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Mond HG, Crozier I. The Australian and New Zealand cardiac pacemaker and implantable cardioverter-defibrillator survey: calendar year 2013. Heart Lung Circ. 2015;24:291–7.CrossRefPubMed Mond HG, Crozier I. The Australian and New Zealand cardiac pacemaker and implantable cardioverter-defibrillator survey: calendar year 2013. Heart Lung Circ. 2015;24:291–7.CrossRefPubMed
2.
Zurück zum Zitat Kusumoto FM, Calkins H, Boehmer J, Buxton AE, Chung MK, Gold MR, Hohnloser SH, et al. HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. Circulation. 2014;130:94–125.CrossRefPubMed Kusumoto FM, Calkins H, Boehmer J, Buxton AE, Chung MK, Gold MR, Hohnloser SH, et al. HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. Circulation. 2014;130:94–125.CrossRefPubMed
3.
Zurück zum Zitat Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA, Freedman RA, Gettes LS, Gillinov AM, et al. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Circulation. 2013;127:283–352.CrossRef Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA, Freedman RA, Gettes LS, Gillinov AM, et al. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Circulation. 2013;127:283–352.CrossRef
4.
Zurück zum Zitat Tompkins C, Cheng A, Dalal D, Brinker JA, Leng CT, Marine JE, Nazarian S, et al. Dual antiplatelet therapy and heparin “bridging” significantly increase the risk of bleeding complications after pacemaker or implantable cardioverter-defibrillator device implantation. J Am Coll Cardiol. 2010;55:2376–82.CrossRefPubMed Tompkins C, Cheng A, Dalal D, Brinker JA, Leng CT, Marine JE, Nazarian S, et al. Dual antiplatelet therapy and heparin “bridging” significantly increase the risk of bleeding complications after pacemaker or implantable cardioverter-defibrillator device implantation. J Am Coll Cardiol. 2010;55:2376–82.CrossRefPubMed
5.
Zurück zum Zitat Douketis JD, Spyropoulos AC, Spencer FA, Mayr M, Jaffer AK, Eckman MH, Dunn AS, et al. Perioperative management of antithrombotic therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest. 2012;141:326–50.CrossRef Douketis JD, Spyropoulos AC, Spencer FA, Mayr M, Jaffer AK, Eckman MH, Dunn AS, et al. Perioperative management of antithrombotic therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest. 2012;141:326–50.CrossRef
6.
Zurück zum Zitat Bernard ML, Shotwell M, Nietert PJ, Gold MR. Meta-analysis of bleeding complications associated with cardiac rhythm device implantation. Circ Arrhythm Electrophysiol. 2012;5:468–74.CrossRefPubMedPubMedCentral Bernard ML, Shotwell M, Nietert PJ, Gold MR. Meta-analysis of bleeding complications associated with cardiac rhythm device implantation. Circ Arrhythm Electrophysiol. 2012;5:468–74.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Wiegand UK, LeJeune D, Boguschewski F, Bonnemeier H, Eberhardt F, Schunkert H, Bode F. Pocket hematoma after pacemaker or implantable cardioverter defibrillator surgery: influence of patient morbidity, operation strategy, and perioperative antiplatelet/anticoagulation therapy. Chest. 2004;126:1177–86.CrossRefPubMed Wiegand UK, LeJeune D, Boguschewski F, Bonnemeier H, Eberhardt F, Schunkert H, Bode F. Pocket hematoma after pacemaker or implantable cardioverter defibrillator surgery: influence of patient morbidity, operation strategy, and perioperative antiplatelet/anticoagulation therapy. Chest. 2004;126:1177–86.CrossRefPubMed
8.
Zurück zum Zitat Boulé S, Marquié C, Vanesson-Bricout C, Kouakam C, Brigadeau F, Guédon-Moreau L, Acheré C. Clopidogrel increases bleeding complications in patients undergoing heart rhythm device procedures. Pacing Clin Electrophysiol. 2012;35:605–11.CrossRefPubMed Boulé S, Marquié C, Vanesson-Bricout C, Kouakam C, Brigadeau F, Guédon-Moreau L, Acheré C. Clopidogrel increases bleeding complications in patients undergoing heart rhythm device procedures. Pacing Clin Electrophysiol. 2012;35:605–11.CrossRefPubMed
9.
Zurück zum Zitat Thal S, Moukabary T, Boyella R, Shanmugasundaram M, Pierce MK, Thai H, Goldman S. The relationship between warfarin, aspirin, and clopidogrel continuation in the peri-procedural period and the incidence of hematoma formation after device implantation. Pacing Clin Electrophysiol. 2010;33:385–8.CrossRefPubMed Thal S, Moukabary T, Boyella R, Shanmugasundaram M, Pierce MK, Thai H, Goldman S. The relationship between warfarin, aspirin, and clopidogrel continuation in the peri-procedural period and the incidence of hematoma formation after device implantation. Pacing Clin Electrophysiol. 2010;33:385–8.CrossRefPubMed
10.
Zurück zum Zitat Ohlow MA, Lauer B, Buchter B, Schreiber M, Geller JC. Pocket related complications in 163 patients receiving anticoagulation or dual antiplatelet therapy: D-Stat Hemostat versus standard of care. Int J Cardiol. 2012;159:177–80.CrossRefPubMed Ohlow MA, Lauer B, Buchter B, Schreiber M, Geller JC. Pocket related complications in 163 patients receiving anticoagulation or dual antiplatelet therapy: D-Stat Hemostat versus standard of care. Int J Cardiol. 2012;159:177–80.CrossRefPubMed
11.
Zurück zum Zitat Ker K, Beecher D, Roberts I. Topical application of tranexamic acid for the reduction of bleeding. Cochrane Database Syst Rev. 2013;7:CD010562. Ker K, Beecher D, Roberts I. Topical application of tranexamic acid for the reduction of bleeding. Cochrane Database Syst Rev. 2013;7:CD010562.
12.
Zurück zum Zitat Kutinsky IB, Jarandilla R, Jewett M, Haines DE. Risk of hematoma complications after device implant in the clopidogrel era. Circ Arrhythm Electrophysiol. 2010;3:312–8.CrossRefPubMed Kutinsky IB, Jarandilla R, Jewett M, Haines DE. Risk of hematoma complications after device implant in the clopidogrel era. Circ Arrhythm Electrophysiol. 2010;3:312–8.CrossRefPubMed
13.
Zurück zum Zitat Birnie DH, Healey JS, Wells GA, Verma A, Tang AS, Krahn AD, Simpson CS, et al. Pacemaker or defibrillator surgery without interruption of anticoagulation. N Engl J Med. 2013;368:2084–93.CrossRefPubMed Birnie DH, Healey JS, Wells GA, Verma A, Tang AS, Krahn AD, Simpson CS, et al. Pacemaker or defibrillator surgery without interruption of anticoagulation. N Engl J Med. 2013;368:2084–93.CrossRefPubMed
14.
Zurück zum Zitat Nammas W, Raatikainen MJ, Korkeila P, Lund J, Ylitalo A, Karjalainen P, Virtanen V, et al. Predictors of pocket hematoma in patients on antithrombotic therapy undergoing cardiac rhythm device implantation: insights from the FinPAC trial. Ann Med. 2014;46:177–81.CrossRefPubMed Nammas W, Raatikainen MJ, Korkeila P, Lund J, Ylitalo A, Karjalainen P, Virtanen V, et al. Predictors of pocket hematoma in patients on antithrombotic therapy undergoing cardiac rhythm device implantation: insights from the FinPAC trial. Ann Med. 2014;46:177–81.CrossRefPubMed
15.
Zurück zum Zitat McCormack PL. Tranexamic acid: a review of its use in the treatment of hyperfibrinolysis. Drugs. 2012;72:585–617.CrossRefPubMed McCormack PL. Tranexamic acid: a review of its use in the treatment of hyperfibrinolysis. Drugs. 2012;72:585–617.CrossRefPubMed
16.
Zurück zum Zitat Kashuk JL, Moore EE, Sawyer M, Wohlauer M, Pezold M, Barnett C, Biffl WL, et al. Primary fibrinolysis is integral in the pathogenesis of the acute coagulopathy of trauma. Ann Surg. 2010;252:434–42.PubMed Kashuk JL, Moore EE, Sawyer M, Wohlauer M, Pezold M, Barnett C, Biffl WL, et al. Primary fibrinolysis is integral in the pathogenesis of the acute coagulopathy of trauma. Ann Surg. 2010;252:434–42.PubMed
17.
Zurück zum Zitat Soares EC, Costa FW, Bezerra TP, Nogueira CB, de Barros Silva PG, Batista SH, Sousa FB. Postoperative hemostatic efficacy of gauze soaked in tranexamic acid, fibrin sponge, and dry gauze compression following dental extractions in anticoagulated patients with cardiovascular disease: a prospective, randomized study. Oral Maxillofac Surg. 2015;19:209–16.CrossRefPubMed Soares EC, Costa FW, Bezerra TP, Nogueira CB, de Barros Silva PG, Batista SH, Sousa FB. Postoperative hemostatic efficacy of gauze soaked in tranexamic acid, fibrin sponge, and dry gauze compression following dental extractions in anticoagulated patients with cardiovascular disease: a prospective, randomized study. Oral Maxillofac Surg. 2015;19:209–16.CrossRefPubMed
18.
Zurück zum Zitat Shi J, Ji H, Ren F, Wang G, Xu M, Xue Y, Chen M, et al. Protective effects of tranexamic acid on clopidogrel before coronary artery bypass grafting: a multicenter randomized trial. JAMA Surg. 2013;148:538–47.CrossRefPubMed Shi J, Ji H, Ren F, Wang G, Xu M, Xue Y, Chen M, et al. Protective effects of tranexamic acid on clopidogrel before coronary artery bypass grafting: a multicenter randomized trial. JAMA Surg. 2013;148:538–47.CrossRefPubMed
19.
Zurück zum Zitat Milic DJ, Perisic ZD, Zivic SS, Stanojkovic ZA, Stojkovic AM, Karanovic ND, Krstic NH, et al. Prevention of pocket related complications with fibrin sealant in patients undergoing pacemaker implantation who are receiving anticoagulant treatment. Europace. 2005;7:374–9.CrossRefPubMed Milic DJ, Perisic ZD, Zivic SS, Stanojkovic ZA, Stojkovic AM, Karanovic ND, Krstic NH, et al. Prevention of pocket related complications with fibrin sealant in patients undergoing pacemaker implantation who are receiving anticoagulant treatment. Europace. 2005;7:374–9.CrossRefPubMed
20.
Zurück zum Zitat Zacà V, Marcucci R, Parodi G, Limbruno U, Notarstefano P, Pieragnoli P, Di Cori A, et al.. Management of antithrombotic therapy in patients undergoing electrophysiological device surgery. Europace. 2015;17:840–54.CrossRefPubMed Zacà V, Marcucci R, Parodi G, Limbruno U, Notarstefano P, Pieragnoli P, Di Cori A, et al.. Management of antithrombotic therapy in patients undergoing electrophysiological device surgery. Europace. 2015;17:840–54.CrossRefPubMed
Metadaten
Titel
Bleeding complications during cardiac electronic device implantation in patients receiving antithrombotic therapy: is there any value of local tranexamic acid?
verfasst von
Osman Beton
Ersin Saricam
Hakki Kaya
Hasan Yucel
Orhan Dogdu
Okan Onur Turgut
Ocal Berkan
Izzet Tandogan
Mehmet Birhan Yilmaz
Publikationsdatum
01.12.2016
Verlag
BioMed Central
Erschienen in
BMC Cardiovascular Disorders / Ausgabe 1/2016
Elektronische ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-016-0251-1

Weitere Artikel der Ausgabe 1/2016

BMC Cardiovascular Disorders 1/2016 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.