Bootstrap methods for estimating PET image noise: experimental validation and an application to evaluation of image reconstruction algorithms

verfasst von: Masanobu Ibaraki, Keisuke Matsubara, Kazuhiro Nakamura, Hiroshi Yamaguchi, Toshibumi Kinoshita

Erschienen in: Annals of Nuclear Medicine | Ausgabe 2/2014

Einloggen, um Zugang zu erhalten

Abstract

Objective

Accurate and validated methods for estimating regional PET image noise are helpful for optimizing image processing. The bootstrap is a data-based simulation method for statistical inference, which can be used to estimate the PET image noise without repeated measurements. The aim of this study was to experimentally validate bootstrap-based methods as a tool for estimating PET image noise and demonstrate its usefulness for evaluating image reconstruction algorithms.

Methods

Two bootstrap-based method, the list-mode data bootstrap (LMBS) and the sinogram bootstrap (SNBS), were implemented on a clinical PET scanner. A uniform cylindrical phantom filled with 18F solution was scanned using list-mode acquisition. A reference standard deviation (SD) map was calculated from 60 statistically independent measured list-mode data. Using one of the 60 list-mode data, 60 bootstrap replicates were generated and used to calculate bootstrap SD maps. Brain 18F-FDG data from a healthy volunteer were also processed as an example of the bootstrap application. Three reconstruction algorithms, FBP 2D and both 2D and 3D versions of dynamic row-action maximum likelihood algorithm (DRAMA), were assessed.

Results

For all the reconstruction algorithms used, the bootstrap SD maps agreed well with the reference SD map, confirming the validity of the bootstrap methods for assessing image noise. The two bootstrap methods were equivalent with respect to the performance of image noise estimation. The bootstrap analysis of the FDG data showed the better contrast–noise relation curve for DRAMA 3D compared to DRAMA 2D and FBP 2D.

Conclusions

The bootstrap methods provide the estimates of image noise for various reconstruction algorithms with reasonable accuracy, require only a single measurement, not repeated measures, and are, therefore, applicable for a human PET study.
Literatur
1.
Zurück zum Zitat Dahlbom M. Estimation of image noise in PET using the bootstrap method. IEEE Trans Nucl Sci. 2002;49:2062–6.CrossRef Dahlbom M. Estimation of image noise in PET using the bootstrap method. IEEE Trans Nucl Sci. 2002;49:2062–6.CrossRef
2.
Zurück zum Zitat Alpert NM, Chesler DA, Correia JA, Ackerman RH, Chang JY, Finklestein S, et al. Estimation of the local statistical noise in emission computed tomography. IEEE Trans Med Imaging. 1982;1:142–6.PubMedCrossRef Alpert NM, Chesler DA, Correia JA, Ackerman RH, Chang JY, Finklestein S, et al. Estimation of the local statistical noise in emission computed tomography. IEEE Trans Med Imaging. 1982;1:142–6.PubMedCrossRef
3.
Zurück zum Zitat Carson RE, Yan Y, Daube-Witherspoon ME, Freedman N, Bacharach SL, Herscovitch P. An approximation formula for the variance of PET region-of-interest values. IEEE Trans Med Imaging. 1993;12:240–50.PubMedCrossRef Carson RE, Yan Y, Daube-Witherspoon ME, Freedman N, Bacharach SL, Herscovitch P. An approximation formula for the variance of PET region-of-interest values. IEEE Trans Med Imaging. 1993;12:240–50.PubMedCrossRef
4.
Zurück zum Zitat Barrett HH, Wilson DW, Tsui BM. Noise properties of the EM algorithm: I. Theory. Phys Med Biol. 1994;39:833–46.PubMedCrossRef Barrett HH, Wilson DW, Tsui BM. Noise properties of the EM algorithm: I. Theory. Phys Med Biol. 1994;39:833–46.PubMedCrossRef
5.
Zurück zum Zitat Soares EJ, Byrne CL, Glick SJ. Noise characterization of block-iterative reconstruction algorithms: I. Theory. IEEE Trans Med Imaging. 2000;19:261–70.PubMedCrossRef Soares EJ, Byrne CL, Glick SJ. Noise characterization of block-iterative reconstruction algorithms: I. Theory. IEEE Trans Med Imaging. 2000;19:261–70.PubMedCrossRef
7.
Zurück zum Zitat Nickerson LD, Narayana S, Lancaster JL, Fox PT, Gao JH. Estimation of the local statistical noise in positron emission tomography revisited: practical implementation. Neuroimage. 2003;19:442–56.PubMedCrossRef Nickerson LD, Narayana S, Lancaster JL, Fox PT, Gao JH. Estimation of the local statistical noise in positron emission tomography revisited: practical implementation. Neuroimage. 2003;19:442–56.PubMedCrossRef
8.
Zurück zum Zitat Haynor DR, Woods SD. Resampling estimates of precision in emission tomography. IEEE Trans Med Imaging. 1989;8:337–43.PubMedCrossRef Haynor DR, Woods SD. Resampling estimates of precision in emission tomography. IEEE Trans Med Imaging. 1989;8:337–43.PubMedCrossRef
9.
Zurück zum Zitat Buvat I. A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images. Phys Med Biol. 2002;47:1761–75.PubMedCrossRef Buvat I. A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images. Phys Med Biol. 2002;47:1761–75.PubMedCrossRef
11.
Zurück zum Zitat Efron B, Tibshirani RJ. An introduction to the bootstrap. Boca Raton: Chapman & Hall/CRC; 1994. Efron B, Tibshirani RJ. An introduction to the bootstrap. Boca Raton: Chapman & Hall/CRC; 1994.
12.
Zurück zum Zitat Matsumoto K, Kitamura K, Mizuta T, Tanaka K, Yamamoto S, Sakamoto S, et al. Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard. J Nucl Med. 2006;47:83–90.PubMed Matsumoto K, Kitamura K, Mizuta T, Tanaka K, Yamamoto S, Sakamoto S, et al. Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard. J Nucl Med. 2006;47:83–90.PubMed
13.
Zurück zum Zitat Ibaraki M, Miura S, Shimosegawa E, Sugawara S, Mizuta T, Ishikawa A, et al. Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: validation by comparison with 2-dimensional PET. J Nucl Med. 2008;49:50–9.PubMedCrossRef Ibaraki M, Miura S, Shimosegawa E, Sugawara S, Mizuta T, Ishikawa A, et al. Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: validation by comparison with 2-dimensional PET. J Nucl Med. 2008;49:50–9.PubMedCrossRef
14.
15.
Zurück zum Zitat Tanaka E, Kudo H. Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography. Phys Med Biol. 2003;48:1405–22.PubMedCrossRef Tanaka E, Kudo H. Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography. Phys Med Biol. 2003;48:1405–22.PubMedCrossRef
17.
Zurück zum Zitat Ibaraki M, Sato K, Mizuta T, Kitamura K, Miura S, Sugawara S, et al. Evaluation of dynamic row-action maximum likelihood algorithm reconstruction for quantitative 15O brain PET. Ann Nucl Med. 2009;23:627–38.PubMedCrossRef Ibaraki M, Sato K, Mizuta T, Kitamura K, Miura S, Sugawara S, et al. Evaluation of dynamic row-action maximum likelihood algorithm reconstruction for quantitative 15O brain PET. Ann Nucl Med. 2009;23:627–38.PubMedCrossRef
18.
Zurück zum Zitat Defrise M, Kinahan PE, Townsend DW, Michel C, Sibomana M, Newport DF. Exact and approximate rebinning algorithms for 3-D PET data. IEEE Trans Med Imaging. 1997;16:145–58.PubMedCrossRef Defrise M, Kinahan PE, Townsend DW, Michel C, Sibomana M, Newport DF. Exact and approximate rebinning algorithms for 3-D PET data. IEEE Trans Med Imaging. 1997;16:145–58.PubMedCrossRef
19.
Zurück zum Zitat Browne J, de Pierro AB. A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography. IEEE Trans Med Imaging. 1996;15:687–99.PubMedCrossRef Browne J, de Pierro AB. A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography. IEEE Trans Med Imaging. 1996;15:687–99.PubMedCrossRef
21.
Zurück zum Zitat Shidahara M, Ikoma Y, Kershaw J, Kimura Y, Naganawa M, Watabe H. PET kinetic analysis: wavelet denoising of dynamic PET data with application to parametric imaging. Ann Nucl Med. 2007;21:379–86.PubMedCrossRef Shidahara M, Ikoma Y, Kershaw J, Kimura Y, Naganawa M, Watabe H. PET kinetic analysis: wavelet denoising of dynamic PET data with application to parametric imaging. Ann Nucl Med. 2007;21:379–86.PubMedCrossRef
22.
Zurück zum Zitat Myers K, Barrett H, Borgstrom M, Patton D, Seeley G. Effect of noise correlation on detectability of disk signals in medical imaging. J Opt Soc Am A. 1985;2:1752.PubMedCrossRef Myers K, Barrett H, Borgstrom M, Patton D, Seeley G. Effect of noise correlation on detectability of disk signals in medical imaging. J Opt Soc Am A. 1985;2:1752.PubMedCrossRef
Metadaten
Titel
Bootstrap methods for estimating PET image noise: experimental validation and an application to evaluation of image reconstruction algorithms
verfasst von
Masanobu Ibaraki
Keisuke Matsubara
Kazuhiro Nakamura
Hiroshi Yamaguchi
Toshibumi Kinoshita
Publikationsdatum
01.02.2014
Verlag
Springer Japan
Erschienen in
Annals of Nuclear Medicine / Ausgabe 2/2014
Print ISSN: 0914-7187
Elektronische ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-013-0782-9

Weitere Artikel der Ausgabe 2/2014

Annals of Nuclear Medicine 2/2014 Zur Ausgabe

Acknowledgements to Reviewers

Acknowledgements to Reviewers