Skip to main content
Erschienen in: Pediatric Cardiology 7/2015

01.10.2015 | Case Report

Catecholaminergic Ventricular Tachycardia, Pregnancy and Teenager: Are They Compatible?

verfasst von: Katie P. Friday, Jeffrey P. Moak, Melissa H. Fries, Sara N. Iqbal

Erschienen in: Pediatric Cardiology | Ausgabe 7/2015

Einloggen, um Zugang zu erhalten

Abstract

Arrhythmias in pregnancy are becoming more common given more available and effective medical, ablation and device treatment options. Several changes associated with pregnancy, increased blood volume, cardiac output, and heart rate secondary to an increased sympathetic state, facilitate more frequent occurrences of arrhythmias throughout the pregnancy and during labor and delivery. We present a case of successful pregnancy in a teenage female with a previous diagnosis of CPVT, followed by a review of the literature.
Literatur
1.
Zurück zum Zitat Akdemir N, Akarsu S, Türe S, Ozlem Akcinar V, Yalcin AA, Bilir C, Serhan Cevrioglu A, Ozden S, Yucel M, Yurumez Y (2012) Evaluation of the relationship between heart type fatty acid binding protein levels and the risk of maternal cardiac ischemia in low risk obstetric population during delivery. Med Glas (Zenica) 9:256–261 Akdemir N, Akarsu S, Türe S, Ozlem Akcinar V, Yalcin AA, Bilir C, Serhan Cevrioglu A, Ozden S, Yucel M, Yurumez Y (2012) Evaluation of the relationship between heart type fatty acid binding protein levels and the risk of maternal cardiac ischemia in low risk obstetric population during delivery. Med Glas (Zenica) 9:256–261
2.
Zurück zum Zitat Bonini W, Botto GL, Broffoni T, Dondina C (2000) Pregnancy with an ICD and a documented ICD discharge. Europace 2:87–90CrossRefPubMed Bonini W, Botto GL, Broffoni T, Dondina C (2000) Pregnancy with an ICD and a documented ICD discharge. Europace 2:87–90CrossRefPubMed
3.
Zurück zum Zitat Boulé S, Ovart L, Marquié C, Botcherby E, Klug D, Kouakam C, Brigadeau F, Guédon-Moreau L, Wissocque L, Meurice J, Lacroix D, Kacet S (2014) Pregnancy in women with an implantable cardioverter-defibrillator: is it safe? Europace 16:1587–1594CrossRefPubMed Boulé S, Ovart L, Marquié C, Botcherby E, Klug D, Kouakam C, Brigadeau F, Guédon-Moreau L, Wissocque L, Meurice J, Lacroix D, Kacet S (2014) Pregnancy in women with an implantable cardioverter-defibrillator: is it safe? Europace 16:1587–1594CrossRefPubMed
4.
Zurück zum Zitat Burrows K, Fox J, Biblo LA, Roth JA (2013) Pregnancy and short-coupled torsades de pointes. Pacing Clin Electrophysiol 36:e77–e79CrossRefPubMed Burrows K, Fox J, Biblo LA, Roth JA (2013) Pregnancy and short-coupled torsades de pointes. Pacing Clin Electrophysiol 36:e77–e79CrossRefPubMed
5.
Zurück zum Zitat Chan TM, Dob DP (2002) The anesthetic management of a parturient with polymorphic catecholamine-sensitive ventricular tachycardia. Int J Obstet Anesth 11:122–124CrossRefPubMed Chan TM, Dob DP (2002) The anesthetic management of a parturient with polymorphic catecholamine-sensitive ventricular tachycardia. Int J Obstet Anesth 11:122–124CrossRefPubMed
6.
Zurück zum Zitat Cuneo BF, Strasburger JF, Yu S, Horigome H, Hosono T, Kandori A, Wakai RT (2013) In utero diagnosis of long QT syndrome by magnetocardiography. Circulation 128:2183–2191CrossRefPubMed Cuneo BF, Strasburger JF, Yu S, Horigome H, Hosono T, Kandori A, Wakai RT (2013) In utero diagnosis of long QT syndrome by magnetocardiography. Circulation 128:2183–2191CrossRefPubMed
7.
Zurück zum Zitat Fukushima A, Nakai K, Matsumoto A, Strasburger J, Sugiyama T (2010) Prenatal diagnosis of polymorphic ventricular tachycardia using 64-channel magnetocardiography. Heart Vessels 25:270–273CrossRefPubMed Fukushima A, Nakai K, Matsumoto A, Strasburger J, Sugiyama T (2010) Prenatal diagnosis of polymorphic ventricular tachycardia using 64-channel magnetocardiography. Heart Vessels 25:270–273CrossRefPubMed
8.
Zurück zum Zitat Hirsimäki H, Kero P, Ekblad H, Scheinin M, Saraste M, Erkkola R (1992) Mode of delivery, plasma catecholamines and Doppler-derived cardiac output in healthy term newborn infants. Biol Neonate 61:285–293CrossRefPubMed Hirsimäki H, Kero P, Ekblad H, Scheinin M, Saraste M, Erkkola R (1992) Mode of delivery, plasma catecholamines and Doppler-derived cardiac output in healthy term newborn infants. Biol Neonate 61:285–293CrossRefPubMed
9.
Zurück zum Zitat Hsiao PY, Tien HC, Lo CP, Juang JM, Wang YH, Sung RJ (2013) Gene mutations in cardiac arrhythmias: a review of recent evidence in ion channelopathies. Appl Clin Genet 6:1–13PubMedCentralPubMed Hsiao PY, Tien HC, Lo CP, Juang JM, Wang YH, Sung RJ (2013) Gene mutations in cardiac arrhythmias: a review of recent evidence in ion channelopathies. Appl Clin Genet 6:1–13PubMedCentralPubMed
10.
Zurück zum Zitat Koster ES, Philbert D, Winters NA, Bouvy ML (2014) Adolescents’ inhaled corticosteroid adherence: the importance of treatment perceptions and medication knowledge. J Asthma 5:1–6 Koster ES, Philbert D, Winters NA, Bouvy ML (2014) Adolescents’ inhaled corticosteroid adherence: the importance of treatment perceptions and medication knowledge. J Asthma 5:1–6
11.
Zurück zum Zitat Moore JS, Teefey P, Rao K et al (2012) Maternal arrhythmia: a case report and review of the literature. Obstet Gynecol Surv 67(5):298–312CrossRefPubMed Moore JS, Teefey P, Rao K et al (2012) Maternal arrhythmia: a case report and review of the literature. Obstet Gynecol Surv 67(5):298–312CrossRefPubMed
12.
Zurück zum Zitat Napolitano C, Priori SG, Bloise R. Catecholaminergic polymorphic ventricular tachycardia. 2004 Oct 14 [Updated 2014 Mar 6]. In: Pagon RA, Adam MP, Bird TD et al (eds) GeneReviews® [Internet]. Seattle (WA): University of Washington, Seattle; 1993–2014. http://www.ncbi.nlm.nih.gov/books/NBK1289/ Napolitano C, Priori SG, Bloise R. Catecholaminergic polymorphic ventricular tachycardia. 2004 Oct 14 [Updated 2014 Mar 6]. In: Pagon RA, Adam MP, Bird TD et al (eds) GeneReviews® [Internet]. Seattle (WA): University of Washington, Seattle; 1993–2014. http://​www.​ncbi.​nlm.​nih.​gov/​books/​NBK1289/​
13.
Zurück zum Zitat Natale A, Davidson T, Geiger MJ, Newby K (1997) Implantable cardioverter-defibrillators and pregnancy: a safe combination? Circulation 96:2808–2812CrossRefPubMed Natale A, Davidson T, Geiger MJ, Newby K (1997) Implantable cardioverter-defibrillators and pregnancy: a safe combination? Circulation 96:2808–2812CrossRefPubMed
14.
Zurück zum Zitat Pohjavuori M, Rovamo L, Laatikainen T, Kariniemi V, Pettersson J (1986) Stress of delivery and plasma endorphins and catecholamines in the newborn infant. Biol Res Pregnancy Perinatol 7:1–5PubMed Pohjavuori M, Rovamo L, Laatikainen T, Kariniemi V, Pettersson J (1986) Stress of delivery and plasma endorphins and catecholamines in the newborn infant. Biol Res Pregnancy Perinatol 7:1–5PubMed
15.
Zurück zum Zitat Schuler PK, Herrey A, Wade A, Brooks R, Peebles D, Lambiase P et al (2012) Pregnancy outcome and management of women with an implantable cardioverter defibrillator: a single centre experience. Europace 14:1740–1745CrossRefPubMed Schuler PK, Herrey A, Wade A, Brooks R, Peebles D, Lambiase P et al (2012) Pregnancy outcome and management of women with an implantable cardioverter defibrillator: a single centre experience. Europace 14:1740–1745CrossRefPubMed
16.
Zurück zum Zitat Vogl SE, Worda C, Egarter C, Bieglmayer C, Szekeres T, Huber J, Husslein P (2006) Mode of delivery is associated with maternal and fetal endocrine stress response. BJOG 113:441–445CrossRefPubMed Vogl SE, Worda C, Egarter C, Bieglmayer C, Szekeres T, Huber J, Husslein P (2006) Mode of delivery is associated with maternal and fetal endocrine stress response. BJOG 113:441–445CrossRefPubMed
17.
Zurück zum Zitat Walker NL, Cobbe SM, McGavigan AD (2009) Paroxysmal bidirectional ventricular tachycardia with tachycardiomyopathy in a pregnant woman. Acta Cardiol 64(3):419–422CrossRefPubMed Walker NL, Cobbe SM, McGavigan AD (2009) Paroxysmal bidirectional ventricular tachycardia with tachycardiomyopathy in a pregnant woman. Acta Cardiol 64(3):419–422CrossRefPubMed
18.
Zurück zum Zitat Wang JX, Zhang WY (2009) The influence of mode of delivery on the level of catecholamines in umbilical cord blood of neonates. Zhonghua Yi Xue Za Zhi 89:1340–1342PubMed Wang JX, Zhang WY (2009) The influence of mode of delivery on the level of catecholamines in umbilical cord blood of neonates. Zhonghua Yi Xue Za Zhi 89:1340–1342PubMed
19.
Zurück zum Zitat Wilders R (2012) Cardiac ion channelopathies and the sudden infant death syndrome. Cardiology 2012:846171 Wilders R (2012) Cardiac ion channelopathies and the sudden infant death syndrome. Cardiology 2012:846171
Metadaten
Titel
Catecholaminergic Ventricular Tachycardia, Pregnancy and Teenager: Are They Compatible?
verfasst von
Katie P. Friday
Jeffrey P. Moak
Melissa H. Fries
Sara N. Iqbal
Publikationsdatum
01.10.2015
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 7/2015
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-015-1232-3

Weitere Artikel der Ausgabe 7/2015

Pediatric Cardiology 7/2015 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.