Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 8/2016

05.10.2015 | Knee

Changes in the orientation of knee functional flexion axis during passive flexion and extension movements in navigated total knee arthroplasty

verfasst von: Francesca Colle, Danilo Bruni, Francesco Iacono, Andrea Visani, Stefano Zaffagnini, Maurilio Marcacci, Nicola Lopomo

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 8/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Recently, the functional flexion axis has been considered to provide a proper rotational alignment of the femoral component in total knee arthroplasty. Several factors could influence the identification of the functional flexion axis. The purpose of this study was to analyse the estimation of the functional flexion axis by separately focusing on passive flexion and extension movements and specifically assessing its orientation compared to the transepicondylar axis, in both the axial plane and the frontal plane.

Methods

Anatomical and kinematic acquisitions were performed using a commercial navigation system on 79 patients undergoing total knee arthroplasty with cruciate substituting prosthesis design. The functional flexion axis was estimated from passive movements, between 0° and 120° of flexion and back. Intra-observer agreement and reliability, internal–external rotation and the angle with the surgical transepicondylar axis, in axial and frontal planes, were separately analysed for flexion and extension, in pre- and post-implant conditions.

Results

The analysis of reliability and agreement showed good results. The identification of the functional flexion axis showed statistically significant differences both in relation to flexion and extension and to pre- and post-implant conditions, both in frontal plane and in axial plane. The analysis of internal–external rotation confirmed these differences in kinematics (p < 0.05, between 25° and 35° of flexion).

Conclusions

The identification of the functional flexion axis changed in relation to passive flexion and extension movements, above all in frontal plane, while it resulted more stable and reliable in axial plane. These findings supported the possible clinical application of the functional flexion axis in the surgical practice by implementing navigated procedures. However, further analyses are required to better understand the factors affecting the identification of the functional flexion axis.

Level of evidence

IV.
Literatur
1.
Zurück zum Zitat Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751–2755CrossRefPubMedPubMedCentral Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751–2755CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Amis AA, Senavongse W, Bull AMJ (2006) Patellofemoral kinematics during knee flexion–extension: an in vitro study. J Orthop Res 24:2201–2211CrossRefPubMed Amis AA, Senavongse W, Bull AMJ (2006) Patellofemoral kinematics during knee flexion–extension: an in vitro study. J Orthop Res 24:2201–2211CrossRefPubMed
3.
Zurück zum Zitat Asano T, Akagi M, Nakamura T (2005) The functional flexion–extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique. J Arthroplasty 20:1060–1067CrossRefPubMed Asano T, Akagi M, Nakamura T (2005) The functional flexion–extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique. J Arthroplasty 20:1060–1067CrossRefPubMed
4.
Zurück zum Zitat Bartlett JW, Frost C (2008) Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables. Ultrasound Obstet Gynecol Off J Int Soc Ultrasound Obstet Gynecol 31:466–475CrossRef Bartlett JW, Frost C (2008) Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables. Ultrasound Obstet Gynecol Off J Int Soc Ultrasound Obstet Gynecol 31:466–475CrossRef
5.
Zurück zum Zitat Blankevoort L, Huiskes R, De Lange A (1990) Helical axes of passive knee joint motions. J Biomech 23:1219–1229CrossRefPubMed Blankevoort L, Huiskes R, De Lange A (1990) Helical axes of passive knee joint motions. J Biomech 23:1219–1229CrossRefPubMed
6.
Zurück zum Zitat Cole GK, Nigg BM, Ronsky JL, Yeadon MR (1993) Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal. J Biomech Eng 115:344–349CrossRefPubMed Cole GK, Nigg BM, Ronsky JL, Yeadon MR (1993) Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal. J Biomech Eng 115:344–349CrossRefPubMed
7.
Zurück zum Zitat Colle F, Bignozzi S, Lopomo N, Zaffagnini S, Sun L, Marcacci M (2012) Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system. Knee Surg Sports Traumatol Arthrosc 20:552–558CrossRefPubMed Colle F, Bignozzi S, Lopomo N, Zaffagnini S, Sun L, Marcacci M (2012) Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system. Knee Surg Sports Traumatol Arthrosc 20:552–558CrossRefPubMed
8.
Zurück zum Zitat Colle F, Lopomo N, Bruni D, Visani A, Iacono F, Zaffagnini S, Marcacci M (2014) Analysis of knee functional flexion axis in navigated TKA: identification and repeatability before and after implant positioning. Knee Surg Sports Traumatol Arthrosc 22:694–702CrossRefPubMed Colle F, Lopomo N, Bruni D, Visani A, Iacono F, Zaffagnini S, Marcacci M (2014) Analysis of knee functional flexion axis in navigated TKA: identification and repeatability before and after implant positioning. Knee Surg Sports Traumatol Arthrosc 22:694–702CrossRefPubMed
9.
Zurück zum Zitat Dennis DA, Mahfouz MR, Komistek RD, Hoff W (2005) In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. J Biomech 38:241–253CrossRefPubMed Dennis DA, Mahfouz MR, Komistek RD, Hoff W (2005) In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. J Biomech 38:241–253CrossRefPubMed
10.
Zurück zum Zitat Doro LC, Hughes RE, Miller JD, Schultz KF, Hallstrom B, Urquhart AG (2008) The reproducibility of a kinematically-derived axis of the knee versus digitized anatomical landmarks using a knee navigation system. Open Biomed Eng J 2:52–56CrossRefPubMedPubMedCentral Doro LC, Hughes RE, Miller JD, Schultz KF, Hallstrom B, Urquhart AG (2008) The reproducibility of a kinematically-derived axis of the knee versus digitized anatomical landmarks using a knee navigation system. Open Biomed Eng J 2:52–56CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Eckhoff D, Hogan C, Di Matteo L, Robinson M, Bach J (2007) Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res 461:238–244PubMed Eckhoff D, Hogan C, Di Matteo L, Robinson M, Bach J (2007) Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res 461:238–244PubMed
12.
Zurück zum Zitat Ehrig RM, Taylor WR, Duda GN, Heller MO (2007) A survey of formal methods for determining functional joint axes. J Biomech 40:2150–2157CrossRefPubMed Ehrig RM, Taylor WR, Duda GN, Heller MO (2007) A survey of formal methods for determining functional joint axes. J Biomech 40:2150–2157CrossRefPubMed
13.
Zurück zum Zitat Feng Y, Tsai TY, Li JS, Wang S, Hu H, Zhang C, Rubash HE, Li G (2015) Motion of the femoral condyles in flexion and extension during a continuous lunge. J Orthop Res 33(4):591–597CrossRefPubMed Feng Y, Tsai TY, Li JS, Wang S, Hu H, Zhang C, Rubash HE, Li G (2015) Motion of the femoral condyles in flexion and extension during a continuous lunge. J Orthop Res 33(4):591–597CrossRefPubMed
14.
Zurück zum Zitat Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144CrossRefPubMed Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144CrossRefPubMed
15.
Zurück zum Zitat Iacono F, Bruni D, Bignozzi S, Colle F, Marcacci M (2014) Does total knee arthroplasty modify flexion axis of the knee? Knee Surg Sports Traumatol Arthrosc 22(8):1728–1735CrossRefPubMed Iacono F, Bruni D, Bignozzi S, Colle F, Marcacci M (2014) Does total knee arthroplasty modify flexion axis of the knee? Knee Surg Sports Traumatol Arthrosc 22(8):1728–1735CrossRefPubMed
16.
Zurück zum Zitat Ishida K, Shibanuma N, Matsumoto T, Sasaki H, Takayama K, Toda A, Kuroda R, Kurosaka M (2015) Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23(6):1741–1747CrossRefPubMed Ishida K, Shibanuma N, Matsumoto T, Sasaki H, Takayama K, Toda A, Kuroda R, Kurosaka M (2015) Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23(6):1741–1747CrossRefPubMed
17.
Zurück zum Zitat Jenny J-Y, Boeri C (2004) Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77CrossRefPubMed Jenny J-Y, Boeri C (2004) Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77CrossRefPubMed
18.
Zurück zum Zitat MacWilliams BA (2008) A comparison of four functional methods to determine centers and axes of rotations. Gait Posture 28:673–679CrossRefPubMed MacWilliams BA (2008) A comparison of four functional methods to determine centers and axes of rotations. Gait Posture 28:673–679CrossRefPubMed
19.
Zurück zum Zitat Maderbacher G, Schaumburger J, Baier C, Zeman F, Springorum HR, Birkenbach AM, Grifka J, Keshmiri A (2015) Appropriate sagittal femoral component alignment cannot be ensured by intramedullary alignment rods. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-015-3541-8 Maderbacher G, Schaumburger J, Baier C, Zeman F, Springorum HR, Birkenbach AM, Grifka J, Keshmiri A (2015) Appropriate sagittal femoral component alignment cannot be ensured by intramedullary alignment rods. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-015-3541-8
20.
Zurück zum Zitat Martelli S, Zaffagnini S, Bignozzi S, Bontempi M, Marcacci M (2006) Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction. Clin Biomech (Bristol Avon) 21:279–287CrossRef Martelli S, Zaffagnini S, Bignozzi S, Bontempi M, Marcacci M (2006) Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction. Clin Biomech (Bristol Avon) 21:279–287CrossRef
21.
Zurück zum Zitat Martelli S, Zaffagnini S, Bignozzi S, Lopomo N, Marcacci M (2007) Description and validation of a navigation system for intra-operative evaluation of knee laxity. Comput Aided Surg 12(3):181–188CrossRefPubMed Martelli S, Zaffagnini S, Bignozzi S, Lopomo N, Marcacci M (2007) Description and validation of a navigation system for intra-operative evaluation of knee laxity. Comput Aided Surg 12(3):181–188CrossRefPubMed
22.
Zurück zum Zitat McGraw KO, Wong SP (1996) Forming inferences about some intraclass correlation coefficients. Psychol Methods 1:30–46CrossRef McGraw KO, Wong SP (1996) Forming inferences about some intraclass correlation coefficients. Psychol Methods 1:30–46CrossRef
23.
Zurück zum Zitat Mihalko WM, Ali M, Phillips MJ, Bayers-Thering M, Krackow KA (2008) Passive knee kinematics before and after total knee arthroplasty: are we correcting pathologic motion? J Arthroplasty 23:57–60CrossRefPubMed Mihalko WM, Ali M, Phillips MJ, Bayers-Thering M, Krackow KA (2008) Passive knee kinematics before and after total knee arthroplasty: are we correcting pathologic motion? J Arthroplasty 23:57–60CrossRefPubMed
24.
Zurück zum Zitat Moon YW, Seo JG, Lim SJ, Yang JH (2010) Variability in femoral component rotation reference axes measured during navigation-assisted total knee arthroplasty using gap technique. J Arthroplasty 25:238–243CrossRefPubMed Moon YW, Seo JG, Lim SJ, Yang JH (2010) Variability in femoral component rotation reference axes measured during navigation-assisted total knee arthroplasty using gap technique. J Arthroplasty 25:238–243CrossRefPubMed
25.
Zurück zum Zitat Oussedik S, Scholes C, Ferguson D, Roe J, Parker D (2012) Is femoral component rotation in a TKA reliably guided by the functional flexion axis? Clin Orthop Relat Res 470(11):3227–3232CrossRefPubMedPubMedCentral Oussedik S, Scholes C, Ferguson D, Roe J, Parker D (2012) Is femoral component rotation in a TKA reliably guided by the functional flexion axis? Clin Orthop Relat Res 470(11):3227–3232CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Reichl I, Leichtle U, Lorenz A (2014) Functionally computed flexion axis reduces kinematic interspecimen variation in in vitro experiments. Comput Methods Biomech Biomed Eng 17(Suppl 1):126–127CrossRef Reichl I, Leichtle U, Lorenz A (2014) Functionally computed flexion axis reduces kinematic interspecimen variation in in vitro experiments. Comput Methods Biomech Biomed Eng 17(Suppl 1):126–127CrossRef
27.
Zurück zum Zitat Siston RA, Patel JJ, Goodman SB, Delp SL, Giori NJ (2005) The variability of femoral rotational alignment in total knee arthroplasty. J Bone Joint Surg Am 87:2276–2280CrossRefPubMed Siston RA, Patel JJ, Goodman SB, Delp SL, Giori NJ (2005) The variability of femoral rotational alignment in total knee arthroplasty. J Bone Joint Surg Am 87:2276–2280CrossRefPubMed
28.
Zurück zum Zitat Siston RA, Cromie MJ, Gold GE, Goodman SB, Delp SL, Maloney WJ, Giori NJ (2008) Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:2098–2104CrossRefPubMed Siston RA, Cromie MJ, Gold GE, Goodman SB, Delp SL, Maloney WJ, Giori NJ (2008) Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:2098–2104CrossRefPubMed
29.
Zurück zum Zitat Vanin N, Panzica M, Dikos G, Krettek C, Hankemeier S (2011) Rotational alignment in total knee arthroplasty: intraoperative inter- and intraobserver reliability of Whiteside’s line. Arch Orthop Trauma Surg 131:1477–1480CrossRefPubMed Vanin N, Panzica M, Dikos G, Krettek C, Hankemeier S (2011) Rotational alignment in total knee arthroplasty: intraoperative inter- and intraobserver reliability of Whiteside’s line. Arch Orthop Trauma Surg 131:1477–1480CrossRefPubMed
30.
Zurück zum Zitat Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95:365–372CrossRefPubMed Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95:365–372CrossRefPubMed
31.
Zurück zum Zitat Wiles AD, Thompson DG, Frantz DD (2004) Accuracy assessment and interpretation for optical tracking systems. In: Proceedings of SPIE Medical Imaging 2004: visualization image-guided procedures, and display, vol 5367, pp 421–432 Wiles AD, Thompson DG, Frantz DD (2004) Accuracy assessment and interpretation for optical tracking systems. In: Proceedings of SPIE Medical Imaging 2004: visualization image-guided procedures, and display, vol 5367, pp 421–432
32.
Zurück zum Zitat Wilson DA, Astephen Wilson JL, Richardson G, Dunbar MJ (2014) Changes in the functional flexion axis of the knee before and after total knee arthroplasty using a navigation system. J Arthroplasty 29(7):1388–1393CrossRefPubMed Wilson DA, Astephen Wilson JL, Richardson G, Dunbar MJ (2014) Changes in the functional flexion axis of the knee before and after total knee arthroplasty using a navigation system. J Arthroplasty 29(7):1388–1393CrossRefPubMed
33.
Zurück zum Zitat Woltring HJ, Huiskes R, de Lange A, Veldpaus FE (1985) Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech 18:379–389CrossRefPubMed Woltring HJ, Huiskes R, de Lange A, Veldpaus FE (1985) Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech 18:379–389CrossRefPubMed
Metadaten
Titel
Changes in the orientation of knee functional flexion axis during passive flexion and extension movements in navigated total knee arthroplasty
verfasst von
Francesca Colle
Danilo Bruni
Francesco Iacono
Andrea Visani
Stefano Zaffagnini
Maurilio Marcacci
Nicola Lopomo
Publikationsdatum
05.10.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 8/2016
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-015-3816-0

Weitere Artikel der Ausgabe 8/2016

Knee Surgery, Sports Traumatology, Arthroscopy 8/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.