Skip to main content
Erschienen in: International Urogynecology Journal 4/2013

01.04.2013 | Original Article

Characterizing the ex vivo textile and structural properties of synthetic prolapse mesh products

verfasst von: Andrew Feola, William Barone, Pamela Moalli, Steven Abramowitch

Erschienen in: International Urogynecology Journal | Ausgabe 4/2013

Einloggen, um Zugang zu erhalten

Abstract

Introduction and hypothesis

The use of polypropylene meshes for surgical repair of pelvic organ prolapse (POP) has been limited by complications, including mesh exposure, encapsulation, and pain. Numerous products are available with a wide array of textile and structural properties. It is thought that complications may be related, in part, to mesh structural properties. However, few descriptions of these properties exists to directly compare products. The aim of this study was to determine the textile and structural properties of five commonly used prolapse mesh products using a ball-burst failure protocol.

Methods

Porosity, anisotropic index, and stiffness of Gynemesh PS (n = 8), the prototype polypropylene mesh for prolapse repair, was compared with four newer-generation mesh produces: UltraPro (n = 5), SmartMesh (n = 5), Novasilk (n = 5), and Polyform (n = 5).

Results

SmartMesh was found to be the most porous, at 78 % ± 1.4 %. This value decreased by 21 % for Gynemesh PS (p < 0.001), 14 % for UltraPro and Novasilk (p < 0.001), and 28 % for Polyform (p < 0.001). Based on the knit pattern, SmartMesh and Polyform were the only products considered to be geometrically isotropic, whereas all other meshes were anisotropic. Comparing the structural properties of these meshes, Gynemesh PS and Polyform were the stiffest: 60 % and 42 % stiffer than SmartMesh (p < 0.001) and Novasilk (p < 0.001), respectively. However, no significant differences were found between these two mesh products and UltraPro.

Conclusions

Porosity, anisotropy, and biomechanical behavior of these five commonly used polypropylene mesh products were significantly different. This study provides baseline data for future implantation studies of prolapse mesh products.
Literatur
1.
Zurück zum Zitat Drutz HP, Alarab M (2006) Pelvic organ prolapse: demographics and future growth prospects. Int Urogynecol J Pelvic Floor Dysfunct 17(Suppl 7):S6–S9PubMed Drutz HP, Alarab M (2006) Pelvic organ prolapse: demographics and future growth prospects. Int Urogynecol J Pelvic Floor Dysfunct 17(Suppl 7):S6–S9PubMed
2.
Zurück zum Zitat Boyles SH, Weber AM, Meyn L (2003) Procedures for pelvic organ prolapse in the United States, 1979–1997. Am J Obstet Gynecol 188(1):108–15PubMedCrossRef Boyles SH, Weber AM, Meyn L (2003) Procedures for pelvic organ prolapse in the United States, 1979–1997. Am J Obstet Gynecol 188(1):108–15PubMedCrossRef
3.
Zurück zum Zitat Brown JS et al (2002) Pelvic organ prolapse surgery in the United States, 1997. Am J Obstet Gynecol 186(4):712–6PubMedCrossRef Brown JS et al (2002) Pelvic organ prolapse surgery in the United States, 1997. Am J Obstet Gynecol 186(4):712–6PubMedCrossRef
4.
Zurück zum Zitat Feola AJ et al (2010) Parity negatively impacts vaginal mechanical properties and collagen structure in rhesus macaques. Am J Obstet Gynecol 203(6):595e1–8CrossRef Feola AJ et al (2010) Parity negatively impacts vaginal mechanical properties and collagen structure in rhesus macaques. Am J Obstet Gynecol 203(6):595e1–8CrossRef
5.
Zurück zum Zitat Chermansky C, Winters J (2012) Complications of vaginal mesh surgery. Curr Opin Urol 22:287–291PubMedCrossRef Chermansky C, Winters J (2012) Complications of vaginal mesh surgery. Curr Opin Urol 22:287–291PubMedCrossRef
6.
Zurück zum Zitat FDA, Urogynecologic Surgical Mesh: Update on the Safety and Effectiveness of Transvaginal Placement for Pelvic Organ Prolapse, E. F.a.D. Administration, Editor 2011 FDA, Urogynecologic Surgical Mesh: Update on the Safety and Effectiveness of Transvaginal Placement for Pelvic Organ Prolapse, E. F.a.D. Administration, Editor 2011
7.
Zurück zum Zitat Haylen BT et al (2010) An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female pelvic floor dysfunction. Int Urogyn J 21(1):5–26CrossRef Haylen BT et al (2010) An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female pelvic floor dysfunction. Int Urogyn J 21(1):5–26CrossRef
9.
Zurück zum Zitat FDA, Public Health Notification: Serious Complications Associated with Transvaginal Placement of Surgical Mesh in Repair of Pelvic Organ Prolapse and Stress Urinary Incontinence, E. F.a.D. Administration, Editor 2008 FDA, Public Health Notification: Serious Complications Associated with Transvaginal Placement of Surgical Mesh in Repair of Pelvic Organ Prolapse and Stress Urinary Incontinence, E. F.a.D. Administration, Editor 2008
10.
Zurück zum Zitat Cardozo L, Staskin D (ed) Textbook of female urology and urogynecology. 2nd Edition ed. Vol. 1. 2006, Informa Healthcare Cardozo L, Staskin D (ed) Textbook of female urology and urogynecology. 2nd Edition ed. Vol. 1. 2006, Informa Healthcare
11.
Zurück zum Zitat Jones KA et al (2009) Tensile properties of commonly used prolapse meshes. Int Urogynecol J Pelvic Floor Dysfunct 20(7):847–53PubMedCrossRef Jones KA et al (2009) Tensile properties of commonly used prolapse meshes. Int Urogynecol J Pelvic Floor Dysfunct 20(7):847–53PubMedCrossRef
12.
Zurück zum Zitat Deffieux X et al (2007) Vaginal mesh erosion after transvaginal repair of cystocele using Gynemesh or Gynemesh-Soft in 138 women: a comparative study. Int Urogynecol J Pelvic Floor Dysfunct 18(1):73–9PubMedCrossRef Deffieux X et al (2007) Vaginal mesh erosion after transvaginal repair of cystocele using Gynemesh or Gynemesh-Soft in 138 women: a comparative study. Int Urogynecol J Pelvic Floor Dysfunct 18(1):73–9PubMedCrossRef
13.
Zurück zum Zitat Ozog Y et al (2011) Persistence of polypropylene mesh anisotropy after implantation: an experimental study. BJOG 118(10):1180–5PubMedCrossRef Ozog Y et al (2011) Persistence of polypropylene mesh anisotropy after implantation: an experimental study. BJOG 118(10):1180–5PubMedCrossRef
14.
15.
Zurück zum Zitat Dalstra M et al (1993) Mechanical and textural properties of pelvic trabecular bone. J Biomech 26(4–5):523–35PubMedCrossRef Dalstra M et al (1993) Mechanical and textural properties of pelvic trabecular bone. J Biomech 26(4–5):523–35PubMedCrossRef
16.
Zurück zum Zitat Shepherd JP et al (2012) Uniaxial biomechanical properties of seven different vaginally implanted meshes for pelvic organ prolapse. Intl Urogyn J 23(5):613–20CrossRef Shepherd JP et al (2012) Uniaxial biomechanical properties of seven different vaginally implanted meshes for pelvic organ prolapse. Intl Urogyn J 23(5):613–20CrossRef
17.
Zurück zum Zitat Krause H et al (2008) Biomechanical properties of raw meshes used in pelvic floor reconstruction. Int Urogyn J 19(12):1677–1681CrossRef Krause H et al (2008) Biomechanical properties of raw meshes used in pelvic floor reconstruction. Int Urogyn J 19(12):1677–1681CrossRef
18.
Zurück zum Zitat Afonso JS et al (2009) Structural and thermal properties of polypropylene mesh used in treatment of stress urinary incontinence. Acta Bioeng Biomech 11(3):27–33PubMed Afonso JS et al (2009) Structural and thermal properties of polypropylene mesh used in treatment of stress urinary incontinence. Acta Bioeng Biomech 11(3):27–33PubMed
Metadaten
Titel
Characterizing the ex vivo textile and structural properties of synthetic prolapse mesh products
verfasst von
Andrew Feola
William Barone
Pamela Moalli
Steven Abramowitch
Publikationsdatum
01.04.2013
Verlag
Springer-Verlag
Erschienen in
International Urogynecology Journal / Ausgabe 4/2013
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-012-1901-1

Weitere Artikel der Ausgabe 4/2013

International Urogynecology Journal 4/2013 Zur Ausgabe

BriefCommunication

Urogynecology digest

Nodal-negativ nach neoadjuvanter Chemo: Axilladissektion verzichtbar?

03.05.2024 Mammakarzinom Nachrichten

Wenn bei Mammakarzinomen durch eine neoadjuvante Chemotherapie ein Downstaging von nodal-positiv zu nodal-negativ gelingt, scheint es auch ohne Axilladissektion nur selten zu axillären Rezidiven zu kommen.

Rezidivierender Peritonsillarabszess nach Oralsex

02.05.2024 Peritonsillarabszess Kasuistik

Die erotischen Dimensionen von Peritonsillarabszessen scheinen eng begrenzt zu sein. Das heißt aber nicht, solche Abszesse und Erotik hätten nichts miteinander gemein, wie ein Fallbericht verdeutlicht.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Ambulantisierung: Erste Erfahrungen mit dem Hybrid-DRG

02.05.2024 DCK 2024 Kongressbericht

Die Hybrid-DRG-Verordnung soll dazu führen, dass mehr chirurgische Eingriffe ambulant durchgeführt werden, wie es in anderen Ländern schon länger üblich ist. Die gleiche Vergütung im ambulanten und stationären Sektor hatten Niedergelassene schon lange gefordert. Aber die Umsetzung bereitet ihnen doch Kopfzerbrechen.

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.