Skip to main content
Erschienen in: International Orthopaedics 12/2013

Open Access 01.12.2013 | Original Paper

Clinical and biomechanical performance of patients with failed rotator cuff repair

verfasst von: Przemyslaw Lubiatowski, Piotr Kaczmarek, Marcin Dzianach, Piotr Ogrodowicz, Maciej Bręborowicz, Jan Długosz, Ewa Lisiewicz, Leszek Romanowski

Erschienen in: International Orthopaedics | Ausgabe 12/2013

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Purpose

The purpose of the study was clinical and advanced biomechanical evaluation of shoulder function with respect to rotator cuff (RC) integrity following repair.

Methods

This was a retrospective study of 111 cases with solid single row rotator cuff repair and a minimal one-year follow-up. The RC repair was performed as an open procedure in 42 patients, arthroscopically assisted in 34 and fully arthroscopic in 48 cases. Evaluation protocol included ultrasound evaluation of the RC integrity, clinical evaluation using shoulder scores and advanced biomechanical evaluation (isometric and the isokinetic strength testing).

Results

Ultrasound evaluation revealed complete retear in 16 %, partial retear in 10 % and intact repair in 74 % of the cases.
Isometric testing of flexion and abduction had shown that shoulders with complete retear were weaker by 45 % compared to those with full tendon healing.
Isokinetic testing revealed 29–43 % deficits in peak external rotation torque comparing complete retear vs. normal healing. Patients’ ability to generate shoulder power and withstand a load proved to be lower in circumstances of a complete lack of healing (40–43 % and 34–55 %, respectively). Partial retears did not have a negative impact on the biomechanical properties of shoulders. Surprisingly, there were no significant differences in the shoulder scores related to the quality of healing. In terms of patient satisfaction the results were good and the patients declared themselves better in all cases, no matter what quality of healing had been recorded ultimately.

Conclusions

According to the results of this research rotator cuff integrity after open or arthroscopic repair does not seem to affect clinical scores. Recurrent tears may result in lower muscle performance in terms of active motion, strength and endurance. Advanced shoulder testing may be essential in assessing the patients’ ability to return to sports or heavy labour.

Introduction

Modern rotator cuff (RC) repair includes minimally invasive arthroscopic procedures providing a stable and solid fixation of the tendons to bone and improved biology with the use of growth factors or scaffolds [15]. Despite such efforts the number of retears reported in literature is quite significant. Nevertheless, many patients do quite well even in the presence of lost integrity following RC repair [6, 7]. Most commonly the final results are evaluated according to pain level, clinical status and quality of life. However, to have a more thorough understanding of biomechanical capabilities of the shoulder following the rotator cuff repair, we decided to include advanced strength testing. The aim of the study was clinical and advanced biomechanical evaluation of shoulder function with respect to rotator cuff integrity following repair.

Material and methods

The study included 111 patients who had a single-row cuff repair for a total of 124 shoulder repairs. The patients were a part of a cohort including 243 cases operated upon between 2002 and 2009. The research was approved by the ethical committee of our institution and included patients with rotator cuff repair and no other shoulder pathologies with available documentation at the one-year follow-up. All the participating cases gave written consent.
The follow-up was performed at an average time of 39.5 months (12–98). The average age of patients was 56 years (40–80), with 84 males and 40 females. The rotator cuff repair was performed as an open procedure in 42 patients, arthroscopically assisted in 34 and fully arthroscopic in 48 cases.
Protocol evaluation included ultrasound scans, clinical evaluation and advanced strength testing.
The ultrasound evaluation of rotator cuff integrity had been performed by a ten-year experienced musculoskeletal radiologist, using the 5–12 MHz linear transducer (HD11 XE system, Phillips Ultrasound, Andover, MA, USA). The insertion and the repair sites were graded as complete retear (cRT), partial retear (pRT) and no retear (nRT). Complete retear was assigned if full thickness tear was diagnosed throughout the width of the repaired RC. Partial retear was rated to partially preserved continuity of the repaired cuff. Fully preserved continuity, with full coverage of footprint by cuff tendons, was regarded as no retear (nRT) (Fig. 1).
Clinical evaluation included assessment of the active ranges of motion (ROM), pain level (0–10 VAS) and clinical scores: UCLA (University of California in Los-Angeles), the simple shoulder test (SST), and the American Shoulder and Elbow Surgeons (ASES) index (SSI).
Advanced biomechanical evaluation was based on shoulder strength testing performed in isometric and isokinetic mode.
The isometric evaluation of shoulder flexion, abduction, internal and external rotation was performed using electronic dynamometer with dedicated PC software (Forcemeter, Progress, Poland). The patient was always examined in a standing position (Fig. 2). The device was attached either to the floor (flexion, abduction) or the wall (internal and external rotation). The belt was adjusted accordingly and held at the patients’ wrist. Flexion strength was evaluated with the arm in a 90° frontal deviation, with abduction at a 90° deviation in the scapular plane. Internal and external rotation strength was examined with the arm along the side and elbow flexed to 90°. Maximum value [N] was recorded in a six second period of maximum contracture.
Isokinetic shoulder evaluation was performed by means of the Biodex System 3 (Biodex Medical Systems, Inc., Shirley, NY) (Fig. 3) for external and internal rotation; values taken into consideration included peak torque, peak torque to body weight, average power and total work. Measurements were performed at 90, 180, 270 and 360°/s. Isokinetic testing was performed according to the standard protocol used in our institutions. The patient was seated and stabilised in the chair in standard sitting position. Rotation movements were performed successively in four angular velocities 180°/s, 90°/s, 360°/s and 270°/s. Peak torque represents the actual strength of the motion. Peak torque related to body weight is considered to more accurately compare the results between patients with different body sizes. Total work accounts for the ability to maintain peak torque over a period of time and practically describes the resistance to fatigue. Average power represents the dynamics of movement and the ability to generate torque within a short time [8].
Statistical analysis was performed using StatPlus mac 2009 software (AnalystSoft) and included normality tests and the analysis of variance (ANOVA).

Results

The ultrasound evaluation revealed complete retear in 20 cases (16 %), partial retear in 12 cases (10 %) and no retear in 92 (74 %) cases (Fig. 1). The average age in the three groups was 55 years (40–71) in the nRT, 53 years (43–74) in the pRT and 57 years in the retear group (46–80) with a majority of males, respectively, of 64 %, 81 % and 65 %.
The results of the clinical evaluation, isometric and isokinetic testing are displayed in Tables 1, 2, and 3. The level of pain and the follow-up time were significantly higher for the partial retears when compared with the group with intact cuffs. The integrity of the repaired tendons did not make any difference in the clinical scores. Patients with complete retears had significantly lower active flexion, showing no other significant differences in the measured range of active motion.
Table 1
Result of clinical evaluation
Clinical assessment
Averages ± SD
Statistical significance by ANOVA (p values)
Complete retear (cRT)
Partial retear (pRT)
No retear (nRT)
cRT vs. nRT
cRT vs. pRT
pRT vs. nRT
Pain (VAS)
3 ± 3.4
3.7 ± 2.3
2.1 ± 2.4
ns
ns
0.049
SSI-ASES
73 ± 26.5
70.2 ± 13.8
79.7 ± 21.3
ns
ns
ns
SST
8.9 ± 3.6
9.8 ± 2.3
9.6 ± 3.2
ns
ns
ns
UCLA
27.2 ± 7.6
29.6 ± 4.5
29.4 ± 5.9
ns
ns
ns
Flexion (°)
145 ± 32
169.1 ± 20.2
163.6 ± 32.9
0.031
0.05
ns
Abduction (°)
150.3 ± 32.5
171.8 ± 15.4
159.6 ± 36.6
ns
ns
ns
External rotation (°)
47.1 ± 22.8
55 ± 20.9
54 ± 21.8
ns
ns
ns
ns not significant with p > 0.05
UCLA University of California in Los Angeles, SST simple shoulder test, SSI-ASES American Shoulder and Elbow Surgeons index
Table 2
Results of isometric shoulder testing by Forcemeter
Isometric strength
Means ± SD
Statistical significance by ANOVA (p values)
Complete retear (cRT)
Partial retear (pRT)
No retear (nRT)
cRT vs. nRT
cRT vs. pRT
pRT vs. nRT
Flexion
31. ± 22
59.1 ± 21.2
58.5 ± 37.2
0.005
0.047
ns
Abduction
33 ± 19.6
52.8 ± 27.2
56.9 ± 35
0.042
ns
ns
External rotation
53.5 ± 31.6
65.3 ± 19.2
73.9 ± 39.8
0.05
ns
ns
Internal rotation
65.2 ± 29.6
80.4 ± 15.9
89.3 ± 43.2
0.040
ns
ns
ns not significant with p > 0.05
Table 3
Results of isokinetic shoulder testing by Biodex System 3
Isokinetic testing
Means ± SD
Statistical significance by ANOVA (p values)
Complete retear (cRT)
Partial retear (pRT)
No retear (nRT)
cRT vs. nRT
cRT vs. pRT
pRT vs. nRT
ER peak torque
90°/s
13.4 ± 10
20.9 ± 6.3
18.1 ± 8
0.043
0.021
ns
180°/s
8.6 ± 9.2
13.2 ± 6.5
13.1 ± 7.8
0.046
ns
ns
270°/s
6.3 ± 7.5
10.1 ± 5.7
9.2 ± 8.1
ns
ns
ns
360°/s
0.3 ± 1
3 ± 5.8
2.5 ± 5
ns
ns
ns
ER PK/BW
90°/s
15 ± 10
26.5 ± 11.8
22.4 ± 8.4
0.003
0.001
ns
180°/s
9.1 ± 11.2
17.8 ± 6
16.1 ± 8.9
0.007
0.02
ns
270°/s
6.2 ± 7.8
12.3 ± 7.2
11.7 ± 9.3
0.036
ns
ns
360°/s
0.3 ± 1.1
3.3 ± 6.6
3 ± 5.9
ns
ns
ns
ER average power
90°/s
9.9 ± 8.6
17.4 ± 5
15.1 ± 8.5
0.029
0.027
ns
180°/s
7.6 ± 8.7
12 ± 7.2
13.2 ± 10.3
0.05
ns
ns
270°/s
4 ± 4.9
7.1 ± 7.7
6.5 ± 81
ns
ns
ns
360°/s
0.1 ± 0.2
1.6 ± 3.7
1.4 ± 3.7
ns
ns
ns
ER total work
90°/s
28.5 ± 23.7
57.3 ± 22.8
48 ± 28
0.012
0.008
ns
180°/s
14.4 ± 16
31.9 ± 15
28 ± 21.7
0.02
0.038
ns
270°/s
42.5 ± 40.1
85.1 ± 71
61.6 ± 69
ns
ns
ns
360°/s
0.1 ± 0.3
3.2 ± 7.6
4.2 ± 13.8
ns
ns
ns
IR peak torque
90°/s
22.7 ± 16.35
34.2 ± 15.2
29.5 ± 12
ns
0.031
0.03
180°/s
13.9 ± 12.5
23.6 ± 14
21.3 ± 10.6
ns
0.031
ns
270°/s
17.5 ± 13.8
24.2 ± 16.6
20.7 ± 11.1
ns
ns
ns
360°/s
11 ± 9.2
17.9 ± 15.7
13.8 ± 9.5
ns
ns
ns
IR PK/BW
90°/s
25 ± 15.8
41 ± 13.4
35.9 ± 13.5
0.005
0.004
ns
180°/s
13.8 ± 12.6
28 ± 13.3
26.4 ± 12.4
ns
ns
ns
270°/s
17.5 ± 14.4
28 ± 15.2
25.1 ± 11.6
ns
ns
ns
360°/s
10.6 ± 10
20.1 ± 14.8
17.1 ± 11.2
ns
ns
ns
IR average Power
90°/s
18.3 ± 16.5
29.8 ± 16.3
22.9 ± 13.7
ns
0.047
ns
180°/s
10.5 ± 15
24.3 ± 17.4
20.5 ± 15.8
0.029
0.031
ns
270°/s
14.5 ± 17.9
26.9 ± 25.7
17.7 ± 15.1
ns
ns
ns
360°/s
8.5 ± 12.3
18 ± 23.1
11 ± 13.3
ns
ns
ns
IR total work
90°/s
59.9 ± 54
115.6 ± 61.9
81.6 ± 44.8
ns
0.005
0.033
180°/s
26.4 ± 38
64.7 ± 40.9
52.3 ± 34.7
ns
ns
ns
270°/s
35.4 ± 39.9
69.7 ± 72.2
59.8 ± 68.7
0.013
0.009
ns
360°/s
15.3 ± 21.3
34.9 ± 38.7
22.2 ± 20.9
ns
0.047
ns
ns not significant with p > 0.05
ER external rotation, IR internal rotation, PK/BW peak torque to body weight
Isometric testing showed the best results in the group with preserved integrity of RC tendons. In comparison, patients with complete retears had significantly weaker flexion, abduction, external and internal rotation. Partial retears did not make the patients weaker than the no-retear group.
Isokinetic testing for external rotation revealed significantly lower values of peak torque, peak torque-to-body-weight, average work and total power when comparing the complete retear group to the remaining two at lower motion velocities (90°/s and 180°/s). Internal rotation testing also showed greater strength for more integrated repair site, however with less significant differences (Table 3).

Discussion

One of the most challenging issues in the rotator cuff repair is to obtain effective and permanent restoration of the tendon-to-bone junction. It is believed that it is not possible to restore the normal tendon-to-bone junction by surgical repair due to very unique structure and function of the junction [9, 10]. The tissue that grows at the tendon repair site has biomechanical properties that are inferior to normal rotator cuff insertion [10]. For that and other reasons lack of proper healing or retear occurs with reported frequency of the problem for 16–94 % of RC repairs [68].
Our study has shown incomplete rotator cuff healing after fixation in 26 % of the cases, out of which 16 % did not heal at all and 10 % of the cases healed partially.
It is not quite clear whether the presence of rotator cuff tear or retear have clinical consequences. Asymptomatic rotator cuff tears have been reported by Scarlat and Florescu who showed up to 56 % asymptomatic cuff tears in healthy individuals over 75 years of age [11]. It is debatable whether the shoulder pain and weakness arise from the RC tear alone. Itoi et al. have shown that the intra-articular or intra-bursal injection of local anaesthetic led to increased strength measured by isokinetic testing [12]. Another study by Norlin and Adolfsson showed that patients with small full thickness tear do well following only arthroscopic decompression without repair [13].
Our study has specifically aimed at the impact of the RC tendon healing on subjective and objective measures of shoulder function. The healing was evaluated by ultrasound scan, which has been acknowledged as a reliable method of RC evaluation and has been used in similar studies before [7, 14, 15]. The study does not focus on possible risk factors of RC retear. As already described in other comparative studies the surgical technique had no effect on results in terms of cuff integrity. For the purpose of evaluation of cuff integrity on clinical results data of all patients have been pooled together both in this and other studies [68].
Patients’ clinical scores (pain, SSI, SST, UCLA, ROM) had improved significantly at follow-up compared to the preoperative status, regardless of the RC integrity at the insertion site. When comparing the results at the final follow-up, patients with a partial retear had slightly more pain compared to those with complete healing. Full-thickness retears did not lead to a significant increase in pain. Surprisingly, there were no significant differences in the shoulder scores related to the quality of healing. Complete retears had a negative effect on active elevation compared to the remaining two groups. Again, surprisingly no such effect could be found when active abduction and external rotation were measured. Basically, patients were satisfied no matter what quality of healing had been recorded ultimately.
However, the most striking differences among the patients was revealed by objective measures. Static isometric testing of flexion and abduction had shown that shoulders with complete RC retear were weaker by 45 % compared to those with full tendon healing. More dynamic testing in the isokinetic mode had revealed 29–43 % deficits in peak external rotation torque comparing complete retear vs. normal healing. Patients’ ability to generate shoulder power and withstand a load proved to be lower in circumstances of a complete lack of healing (40–43 % and 34–55 %, respectively). Partial retears did not have a negative impact on the biomechanical properties of shoulders. Moreover, those patients also did better on testing than complete retears.
As in our study, Yoo et al. and Liem had found a negative influence of retear on clinical results [16, 17]. In Liem’s study, shoulder abduction was decreased for cuffs with retear among open and arthroscopically repaired patients, yet significant differences were found only among the latter group. Zumstein et al. and Verma et al. found no difference in the outcome scores and pain level among patients with or without RC retear [7, 18]. In Verma’s study, patients with failed RC repair had significantly lower strength of forward flexion but not external rotation; and that was found regardless of the repair technique (arthroscopic vs. mini-open). Bishop et al., in a prospective study, examined RC integrity by also comparing arthoscopic versus open repair [6]. The authors found superior isometric testing results for flexion and external rotation as well as ASES and Constant score in the group with intact cuffs. Pain values remained improved following repair with no difference between preserved and retorn RC at the follow-up. They had also found that there was no significant difference in outcomes between open versus arthroscopic repair for any of the scores when the intact and retear groups were compared. Work by Millar et al. showed that regardless of the cuff integrity following repair parameters of pain, range of active motion, external and internal rotation strength improved with no significant differences [5]. However, patients with intact cuffs had better abduction strength and less pain on overhead activity. Demirors et al. found that the failed rotator cuff repair group showed lower levels of isokinetic extension and internal rotation. Despite high failure rate in their group functional results were satisfactory [19].
We have used more advanced and extensive biomechanical and objective measurements in this study including isometric and isokinetic evaluation. Isometric testing is a simple, quick and relatively inexpensive method of objective shoulder strength evaluation [20]. It allows for the detection of static strength deficits not being able to evaluate more advanced functionality. Isokinetic testing is more sophisticated, allowing a more functional evaluation [8]. It is possible to detect deficits in a moving shoulder and also reflects shoulder ability to generate power and performance of a working shoulder over time. Our study demonstrates that patients with complete retears are not only weaker in shoulder motion, but also are not able to perform work with different loads over a period of time. This may have an impact on the ability to return to heavy labour or sports. For those reasons, it seems that more objective measures should be introduced in populations that return to full activity. Possibly, for such patients, limitation of shoulder loading should be suggested.
We have also looked at patients with partial retears (or partial healing). Those patients performed as well as those with normal healing in both subjective and objective evaluation. The only exception was a slightly higher pain level. A similar phenomenon had also been found among patients with partial RC tears that seem to experience more pain than those with full thickness tears, and in theory, cause abnormal tension to the remaining tendon fibres [21]. In our study this group showed otherwise good function and had comparable biomechanical abilities as patients with complete healing.
Many studies and conference presentations have attempted to improve cuff integrity results by applying the double row or double row suture-bridge technique. The techniques seem to have superior biomechanical and biological properties [13]. Although the techniques do not prove to be clinically superior to single row fixation, they may have advantages in improving cuff integrity when the double row technique is used [13, 2225]. Based on that and results of our study we should tend to obtain the best possible healing in patients with high biomechanical demands. Having good integrity leads to superior strength and endurance results. This issue might be important for heavy physical workers or athletes (not necessarily fully professional) wishing to get back to previous activity on a similar level. The physical performance of workers might be important information for employers bearing in mind both job safety, safe return to former duties and costs of work-related injuries. Proper testing and its results would help to determine time of returning to sports or heavy labour or establishing permanent limitations for future activity.

Conclusions

According to the results of this research rotator cuff integrity after open or arthroscopic repair does not seem to affect clinical scores. Recurrent tears may result in lower muscle performance in terms of active motion, strength and endurance. Advanced shoulder testing may be essential in assessing the patients’ ability to return to sports or heavy labour.
Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Dines JS, Bedi A, El Attrache NS, Dines DM (2010) Single-row versus double-row rotator cuff repair: techniques and outcomes. J Am Acad Orthop Surg 18:83–93PubMed Dines JS, Bedi A, El Attrache NS, Dines DM (2010) Single-row versus double-row rotator cuff repair: techniques and outcomes. J Am Acad Orthop Surg 18:83–93PubMed
2.
Zurück zum Zitat Spang JT, Buchmann S, Brucker PU et al (2009) A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior. Arthroscopy 25:872–879PubMedCrossRef Spang JT, Buchmann S, Brucker PU et al (2009) A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior. Arthroscopy 25:872–879PubMedCrossRef
3.
Zurück zum Zitat Pauly S, Kieser B, Schill A, Gerhardt C, Scheibel M (2010) Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations. Arthroscopy 26:1281–1288PubMedCrossRef Pauly S, Kieser B, Schill A, Gerhardt C, Scheibel M (2010) Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations. Arthroscopy 26:1281–1288PubMedCrossRef
4.
Zurück zum Zitat Derwin KA, Badylak SF, Steinmann SP, Iannotti JP (2010) Extracellular matrix scaffold devices for rotator cuff repair. J Shoulder Elbow Surg 19:467–476PubMedCrossRef Derwin KA, Badylak SF, Steinmann SP, Iannotti JP (2010) Extracellular matrix scaffold devices for rotator cuff repair. J Shoulder Elbow Surg 19:467–476PubMedCrossRef
5.
Zurück zum Zitat Millar NL, Wu X, Tantau R, Silverstone E, Murrell GA (2009) Open versus two forms of arthroscopic rotator cuff repair. Clin Orthop Relat Res 467:966–978PubMedCrossRef Millar NL, Wu X, Tantau R, Silverstone E, Murrell GA (2009) Open versus two forms of arthroscopic rotator cuff repair. Clin Orthop Relat Res 467:966–978PubMedCrossRef
6.
Zurück zum Zitat Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL (2006) Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg 15:290–299PubMedCrossRef Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL (2006) Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg 15:290–299PubMedCrossRef
7.
Zurück zum Zitat Verma NN, Dunn W, Adler RS et al (2006) All-arthroscopic versus mini-open rotator cuff repair: a retrospective review with minimum 2-year follow-up. Arthroscopy 22:587–594PubMedCrossRef Verma NN, Dunn W, Adler RS et al (2006) All-arthroscopic versus mini-open rotator cuff repair: a retrospective review with minimum 2-year follow-up. Arthroscopy 22:587–594PubMedCrossRef
8.
Zurück zum Zitat Ellenbecker TS, Davies GJ (2000) The application of isokinetics in testing and rehabilitation of the shoulder complex. J Athl Train 35:338–350PubMed Ellenbecker TS, Davies GJ (2000) The application of isokinetics in testing and rehabilitation of the shoulder complex. J Athl Train 35:338–350PubMed
9.
Zurück zum Zitat Lui P, Zhang P, Chan K, Qin L (2010) Biology and augmentation of tendon-bone insertion repair. J Orthop Surg Res 5:59PubMedCrossRef Lui P, Zhang P, Chan K, Qin L (2010) Biology and augmentation of tendon-bone insertion repair. J Orthop Surg Res 5:59PubMedCrossRef
10.
Zurück zum Zitat Carpenter JE, Thomopoulos S, Flanagan CL, DeBano CM, Soslowsky LJ (1998) Rotator cuff defect healing: a biomechanical and histologic analysis in an animal model. J Shoulder Elbow Surg 7:599–605PubMedCrossRef Carpenter JE, Thomopoulos S, Flanagan CL, DeBano CM, Soslowsky LJ (1998) Rotator cuff defect healing: a biomechanical and histologic analysis in an animal model. J Shoulder Elbow Surg 7:599–605PubMedCrossRef
11.
Zurück zum Zitat Scarlat M, Florescu A (2005) Shoulder function and scores in 180 asymptomatic individuals aged over 75 years. Rev Chir Orthop Reparatrice Appar Mot 91(6):502–507PubMedCrossRef Scarlat M, Florescu A (2005) Shoulder function and scores in 180 asymptomatic individuals aged over 75 years. Rev Chir Orthop Reparatrice Appar Mot 91(6):502–507PubMedCrossRef
12.
Zurück zum Zitat Itoi E, Minagawa H, Sato T, Sato K, Tabata S (1997) Isokinetic strength after tears of the supraspinatus tendon. J Bone Joint Surg Br 79:77–82PubMedCrossRef Itoi E, Minagawa H, Sato T, Sato K, Tabata S (1997) Isokinetic strength after tears of the supraspinatus tendon. J Bone Joint Surg Br 79:77–82PubMedCrossRef
13.
Zurück zum Zitat Norlin R, Adolfsson L (2008) Small full-thickness tears do well ten to thirteen years after arthroscopic subacromial decompression. J Shoulder Elbow Surg 17:12–16CrossRef Norlin R, Adolfsson L (2008) Small full-thickness tears do well ten to thirteen years after arthroscopic subacromial decompression. J Shoulder Elbow Surg 17:12–16CrossRef
14.
Zurück zum Zitat Dinnes J, Loveman E, McIntyre L, Waugh N (2003) The effectiveness of diagnostic tests for the assessment of shoulder pain due to soft tissue disorders: a systematic review. Health Technol Assess 7:1–166 Dinnes J, Loveman E, McIntyre L, Waugh N (2003) The effectiveness of diagnostic tests for the assessment of shoulder pain due to soft tissue disorders: a systematic review. Health Technol Assess 7:1–166
15.
Zurück zum Zitat de Jesus JO, Parker L, Frangos AJ, Nazarian LN (2009) Accuracy of MRI, MR arthrography, and ultrasound in the diagnosis of rotator cuff tears: a meta-analysis. Am J Roentgenol 192:1701–1707CrossRef de Jesus JO, Parker L, Frangos AJ, Nazarian LN (2009) Accuracy of MRI, MR arthrography, and ultrasound in the diagnosis of rotator cuff tears: a meta-analysis. Am J Roentgenol 192:1701–1707CrossRef
16.
Zurück zum Zitat Yoo JC, Ahn JH, Koh KH, Lim KS (2009) Rotator cuff integrity after arthroscopic repair for large tears with less-than-optimal footprint coverage. Arthroscopy 25:1093–1100PubMedCrossRef Yoo JC, Ahn JH, Koh KH, Lim KS (2009) Rotator cuff integrity after arthroscopic repair for large tears with less-than-optimal footprint coverage. Arthroscopy 25:1093–1100PubMedCrossRef
17.
Zurück zum Zitat Liem D, Bartl C, Lichtenberg S, Magosch P, Habermeyer P (2007) Clinical outcome and tendon integrity of arthroscopic versus mini-open supraspinatus tendon repair: a magnetic resonance imaging-controlled matched-pair analysis. Arthroscopy 23:514–521PubMedCrossRef Liem D, Bartl C, Lichtenberg S, Magosch P, Habermeyer P (2007) Clinical outcome and tendon integrity of arthroscopic versus mini-open supraspinatus tendon repair: a magnetic resonance imaging-controlled matched-pair analysis. Arthroscopy 23:514–521PubMedCrossRef
18.
Zurück zum Zitat Zumstein MA, Jost B, Hempel J, Hodler J, Gerber C (2008) The clinical and structural long-term results of open repair of massive tears of the rotator cuff. J Bone Joint Surg Am 90:2423–2431PubMedCrossRef Zumstein MA, Jost B, Hempel J, Hodler J, Gerber C (2008) The clinical and structural long-term results of open repair of massive tears of the rotator cuff. J Bone Joint Surg Am 90:2423–2431PubMedCrossRef
19.
Zurück zum Zitat Demirors H, Circi E, Akgun RC, Tarhan NC, Cetin N, Akpinar S, Tuncay IC (2010) Correlations of isokinetic measurements with tendon healing following open repair of rotator cuff tears. Int Orthop 34(4):531–536PubMedCrossRef Demirors H, Circi E, Akgun RC, Tarhan NC, Cetin N, Akpinar S, Tuncay IC (2010) Correlations of isokinetic measurements with tendon healing following open repair of rotator cuff tears. Int Orthop 34(4):531–536PubMedCrossRef
20.
Zurück zum Zitat Leggin BG, Neuman RM, Iannotti JP, Williams GR, Thompson EC (1996) Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength. J Shoulder Elbow Surg 5:18–24PubMedCrossRef Leggin BG, Neuman RM, Iannotti JP, Williams GR, Thompson EC (1996) Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength. J Shoulder Elbow Surg 5:18–24PubMedCrossRef
21.
Zurück zum Zitat Fukuda H (2000) Partial-thickness rotator cuff tears: a modern view on Codman’s classic. J Shoulder Elbow Surg 9:163–168PubMedCrossRef Fukuda H (2000) Partial-thickness rotator cuff tears: a modern view on Codman’s classic. J Shoulder Elbow Surg 9:163–168PubMedCrossRef
22.
Zurück zum Zitat Apreleva M, Ozbaydar M, Fitzgibbons PG, Warner JJ (2002) Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area. Arthroscopy 18:519–526PubMedCrossRef Apreleva M, Ozbaydar M, Fitzgibbons PG, Warner JJ (2002) Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area. Arthroscopy 18:519–526PubMedCrossRef
23.
Zurück zum Zitat Carbonel I, Martinez AA, Calvo A, Ripalda J, Herrera A (2012) Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study. Int Orthop 36(9):1877–1883PubMedCrossRef Carbonel I, Martinez AA, Calvo A, Ripalda J, Herrera A (2012) Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study. Int Orthop 36(9):1877–1883PubMedCrossRef
24.
Zurück zum Zitat Perser K, Godfrey D, Bisson L (2011) Meta-analysis of clinical and radiographic outcomes after arthroscopic single-row versus double-row rotator cuff repair. Sports Health 3(3):268–274PubMedCrossRef Perser K, Godfrey D, Bisson L (2011) Meta-analysis of clinical and radiographic outcomes after arthroscopic single-row versus double-row rotator cuff repair. Sports Health 3(3):268–274PubMedCrossRef
25.
Zurück zum Zitat Duquin TR, Buyea C, Bisson LJ (2010) Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review. Am J Sports Med 38(4):835–841PubMedCrossRef Duquin TR, Buyea C, Bisson LJ (2010) Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review. Am J Sports Med 38(4):835–841PubMedCrossRef
Metadaten
Titel
Clinical and biomechanical performance of patients with failed rotator cuff repair
verfasst von
Przemyslaw Lubiatowski
Piotr Kaczmarek
Marcin Dzianach
Piotr Ogrodowicz
Maciej Bręborowicz
Jan Długosz
Ewa Lisiewicz
Leszek Romanowski
Publikationsdatum
01.12.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 12/2013
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-2024-0

Weitere Artikel der Ausgabe 12/2013

International Orthopaedics 12/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.