Skip to main content
Erschienen in: International Journal of Hematology 2/2017

07.04.2017 | Original Article

Clinical usefulness of the dilute Russell viper venom time test for patients taking warfarin

verfasst von: Kazunori Kanouchi, Hiroto Narimatsu, Okio Ohnuma, Keita Morikane, Akira Fukao

Erschienen in: International Journal of Hematology | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Warfarin use often causes false-positive results in the dilute Russell viper venom time test (DRVVT). Thus, three sets of guidelines—those presented by the International Society on Haemostasis and Thrombosis (ISTH), the British Committee for Standards in Haematology (BCSH), and the Clinical and Laboratory Standards Institute (CLSI)—are advocated. We evaluated the clinical usefulness of the testing methods recommended in these three guidelines using laboratory samples. Of the 242 samples from patients using warfarin, 38 were positive for lupus anticoagulant (LA). After adding normal pooled plasma (NPP) as recommended in the ISTH, BCSH, and CLSI guidelines, the number of samples testing positive for LA decreased to 13, 18, and 19, respectively. The number of samples with inconsistent results between the activated partial thromboplastin time and mixing test, and the DRVVT following the ISTH, BCSH, and CLSI guidelines were four of 205 (1.9%), 15 of 242 (6.2%), and 17 of 242 (7.0%), respectively. In patients with an international normalized ratio (INR) ≥3.0, 11 of 37 (29.7%) and 12 of 37 (32.4%) samples showed inconsistent results according to the BCSH and CLSI guidelines, respectively. The accuracy of the DRVVT result may thus decrease in markedly anticoagulated patients.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Miyakis S, Lockshin MD, Atsumi T, Branch DW, Brey RL, Cervera R, et al. International consensus statement on an update of the classification criteria for definite antiphospholipid syndrome (APS). J Thromb Haemost. 2006;4:295–306.CrossRefPubMed Miyakis S, Lockshin MD, Atsumi T, Branch DW, Brey RL, Cervera R, et al. International consensus statement on an update of the classification criteria for definite antiphospholipid syndrome (APS). J Thromb Haemost. 2006;4:295–306.CrossRefPubMed
2.
Zurück zum Zitat Moore GW. Recent guidelines and recommendations for laboratory detection of lupus anticoagulants. Semin Thromb Hemost. 2014;40:163–71.CrossRefPubMed Moore GW. Recent guidelines and recommendations for laboratory detection of lupus anticoagulants. Semin Thromb Hemost. 2014;40:163–71.CrossRefPubMed
3.
Zurück zum Zitat Ashrani AA, Aysola A, Al-Khatib H, Nichols WL, Key NS. Lupus anticoagulant associated with transient severe factor X deficiency: a report of two patients presenting with major bleeding complications. Br J Haematol. 2003;121:639–42.CrossRefPubMed Ashrani AA, Aysola A, Al-Khatib H, Nichols WL, Key NS. Lupus anticoagulant associated with transient severe factor X deficiency: a report of two patients presenting with major bleeding complications. Br J Haematol. 2003;121:639–42.CrossRefPubMed
4.
Zurück zum Zitat Jouhikainen T. Detection of lupus anticoagulant by means of dilute Russell’s viper venom time is affected by oral anticoagulant therapy. Blood Coagul Fibrinolysis. 1990;1:627–32.PubMed Jouhikainen T. Detection of lupus anticoagulant by means of dilute Russell’s viper venom time is affected by oral anticoagulant therapy. Blood Coagul Fibrinolysis. 1990;1:627–32.PubMed
5.
Zurück zum Zitat Moore GW. Commonalities and contrasts in recent guidelines for lupus anticoagulant detection. Int J Lab Hematol. 2014;36:364–73.CrossRefPubMed Moore GW. Commonalities and contrasts in recent guidelines for lupus anticoagulant detection. Int J Lab Hematol. 2014;36:364–73.CrossRefPubMed
6.
Zurück zum Zitat Keeling D, Mackie I, Moore GW, Greer IA, Greaves M. Haematology BCfSi. Guidelines on the investigation and management of antiphospholipid syndrome. Br J Haematol. 2012;157:47–58.CrossRefPubMed Keeling D, Mackie I, Moore GW, Greer IA, Greaves M. Haematology BCfSi. Guidelines on the investigation and management of antiphospholipid syndrome. Br J Haematol. 2012;157:47–58.CrossRefPubMed
7.
Zurück zum Zitat Pengo V, Tripodi A, Reber G, Rand JH, Ortel TL, Galli M, et al. Update of the guidelines for lupus anticoagulant detection. Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis. J Thromb Haemost. 2009;7:1737–40.CrossRefPubMed Pengo V, Tripodi A, Reber G, Rand JH, Ortel TL, Galli M, et al. Update of the guidelines for lupus anticoagulant detection. Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis. J Thromb Haemost. 2009;7:1737–40.CrossRefPubMed
8.
Zurück zum Zitat Pennings MT, De Groot PG, Meijers JC, Huisman A, Derksen RH, Urbanus RT. Optimisation of lupus anticoagulant tests: should test samples always be mixed with normal plasma? Thromb Haemost. 2014;112:736–42.CrossRefPubMed Pennings MT, De Groot PG, Meijers JC, Huisman A, Derksen RH, Urbanus RT. Optimisation of lupus anticoagulant tests: should test samples always be mixed with normal plasma? Thromb Haemost. 2014;112:736–42.CrossRefPubMed
9.
Zurück zum Zitat Chantarangkul V, Biguzzi E, Asti D, Palmucci C, Tripodi A. Laboratory diagnostic outcome applying detection criteria recommended by the Scientific and Standardization Committee of the ISTH on Lupus Anticoagulant. Thromb Haemost. 2013;110:46–52.CrossRefPubMed Chantarangkul V, Biguzzi E, Asti D, Palmucci C, Tripodi A. Laboratory diagnostic outcome applying detection criteria recommended by the Scientific and Standardization Committee of the ISTH on Lupus Anticoagulant. Thromb Haemost. 2013;110:46–52.CrossRefPubMed
10.
Zurück zum Zitat Olteanu H, Downes KA, Patel J, Praprotnik D, Sarode R. Warfarin does not interfere with lupus anticoagulant detection by dilute Russell’s viper venom time. Clin Lab. 2009;55:138–42.PubMed Olteanu H, Downes KA, Patel J, Praprotnik D, Sarode R. Warfarin does not interfere with lupus anticoagulant detection by dilute Russell’s viper venom time. Clin Lab. 2009;55:138–42.PubMed
11.
Zurück zum Zitat Moore GW. Combining Taipan snake venom time/Ecarin time screening with the mixing studies of conventional assays increases detection rates of lupus anticoagulants in orally anticoagulated patients. Thromb J. 2007;5:12.CrossRefPubMedPubMedCentral Moore GW. Combining Taipan snake venom time/Ecarin time screening with the mixing studies of conventional assays increases detection rates of lupus anticoagulants in orally anticoagulated patients. Thromb J. 2007;5:12.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Moore GW, Smith MP, Savidge GF. The Ecarin time is an improved confirmatory test for the Taipan snake venom time in warfarinized patients with lupus anticoagulants. Blood Coagul Fibrinolysis. 2003;14:307–12.PubMed Moore GW, Smith MP, Savidge GF. The Ecarin time is an improved confirmatory test for the Taipan snake venom time in warfarinized patients with lupus anticoagulants. Blood Coagul Fibrinolysis. 2003;14:307–12.PubMed
13.
Zurück zum Zitat Moore GW, Rangarajan S, Savidge GF. The activated seven lupus anticoagulant assay detects clinically significant antibodies. Clin Appl Thromb Hemost. 2008;14:332–7.CrossRefPubMed Moore GW, Rangarajan S, Savidge GF. The activated seven lupus anticoagulant assay detects clinically significant antibodies. Clin Appl Thromb Hemost. 2008;14:332–7.CrossRefPubMed
14.
Zurück zum Zitat Triplett DA, Barna LK, Unger GA. A hexagonal (II) phase phospholipid neutralization assay for lupus anticoagulant identification. Thromb Haemost. 1993;70:787–93.PubMed Triplett DA, Barna LK, Unger GA. A hexagonal (II) phase phospholipid neutralization assay for lupus anticoagulant identification. Thromb Haemost. 1993;70:787–93.PubMed
15.
Zurück zum Zitat Brandt JT, Barna LK, Triplett DA. Laboratory identification of lupus anticoagulants: results of the Second International Workshop for Identification of Lupus Anticoagulants. On behalf of the Subcommittee on Lupus Anticoagulants/Antiphospholipid Antibodies of the ISTH. Thromb Haemost. 1995;74:1597–603.PubMed Brandt JT, Barna LK, Triplett DA. Laboratory identification of lupus anticoagulants: results of the Second International Workshop for Identification of Lupus Anticoagulants. On behalf of the Subcommittee on Lupus Anticoagulants/Antiphospholipid Antibodies of the ISTH. Thromb Haemost. 1995;74:1597–603.PubMed
16.
Zurück zum Zitat Kumano O, Ieko M, Naito S, Yoshida M, Takahashi N, Suzuki T, et al. Lupus anticoagulant diagnosis in activated partial thromboplastin time mixing test: optimization of the index of circulating anticoagulant cut-off value. Clin Lab. 2014;60:2115–8.CrossRefPubMed Kumano O, Ieko M, Naito S, Yoshida M, Takahashi N, Suzuki T, et al. Lupus anticoagulant diagnosis in activated partial thromboplastin time mixing test: optimization of the index of circulating anticoagulant cut-off value. Clin Lab. 2014;60:2115–8.CrossRefPubMed
17.
Zurück zum Zitat Kumano O, Ieko M, Naito S, Yoshida M, Takahashi N, Suzuki T, et al. Verification of the guidelines for lupus anticoagulant detection: usefulness of index for circulating anticoagulant in APTT mixing test. Thromb Res. 2014;134:503–9.CrossRefPubMed Kumano O, Ieko M, Naito S, Yoshida M, Takahashi N, Suzuki T, et al. Verification of the guidelines for lupus anticoagulant detection: usefulness of index for circulating anticoagulant in APTT mixing test. Thromb Res. 2014;134:503–9.CrossRefPubMed
18.
Zurück zum Zitat Triplett DA. Use of the dilute Russell viper venom time (dRVVT): its importance and pitfalls. J Autoimmun. 2000;15:173–8.CrossRefPubMed Triplett DA. Use of the dilute Russell viper venom time (dRVVT): its importance and pitfalls. J Autoimmun. 2000;15:173–8.CrossRefPubMed
19.
Zurück zum Zitat Thiagarajan P, Pengo V, Shapiro SS. The use of the dilute Russell viper venom time for the diagnosis of lupus anticoagulants. Blood. 1986;68:869–74.PubMed Thiagarajan P, Pengo V, Shapiro SS. The use of the dilute Russell viper venom time for the diagnosis of lupus anticoagulants. Blood. 1986;68:869–74.PubMed
20.
Zurück zum Zitat Exner T, Papadopoulos G, Koutts J. Use of a simplified dilute Russell’s viper venom time (DRVVT) confirms heterogeneity among ‘lupus anticoagulants’. Blood Coagul Fibrinolysis. 1990;1:259–66.CrossRefPubMed Exner T, Papadopoulos G, Koutts J. Use of a simplified dilute Russell’s viper venom time (DRVVT) confirms heterogeneity among ‘lupus anticoagulants’. Blood Coagul Fibrinolysis. 1990;1:259–66.CrossRefPubMed
21.
Zurück zum Zitat Thom J, Ivey L, Gilmore G, Eikelboom JW. Evaluation of the phospholipid-rich dilute Russell’s viper venom assay to monitor oral anticoagulation in patients with lupus anticoagulant. Blood Coagul Fibrinolysis. 2004;15:353–7.CrossRefPubMed Thom J, Ivey L, Gilmore G, Eikelboom JW. Evaluation of the phospholipid-rich dilute Russell’s viper venom assay to monitor oral anticoagulation in patients with lupus anticoagulant. Blood Coagul Fibrinolysis. 2004;15:353–7.CrossRefPubMed
22.
Zurück zum Zitat Girolami A, Scapin M, Scarparo P, Vettore S. Different genotypes are responsible for the normal Russell viper venom assays seen in some cases of congenital factor X deficiency. Am J Hematol. 2008;83:884–5.CrossRefPubMed Girolami A, Scapin M, Scarparo P, Vettore S. Different genotypes are responsible for the normal Russell viper venom assays seen in some cases of congenital factor X deficiency. Am J Hematol. 2008;83:884–5.CrossRefPubMed
23.
Zurück zum Zitat Kanda Y. Investigation of the freely available easy-to-use software ‘EZR’ for medical statistics. Bone Marrow Transplant. 2013;48:452–8.CrossRefPubMed Kanda Y. Investigation of the freely available easy-to-use software ‘EZR’ for medical statistics. Bone Marrow Transplant. 2013;48:452–8.CrossRefPubMed
24.
Zurück zum Zitat Lawrie AS, Mackie IJ, Purdy G, Machin SJ. The sensitivity and specificity of commercial reagents for the detection of lupus anticoagulant show marked differences in performance between photo-optical and mechanical coagulometers. Thromb Haemost. 1999;81:758–62.PubMed Lawrie AS, Mackie IJ, Purdy G, Machin SJ. The sensitivity and specificity of commercial reagents for the detection of lupus anticoagulant show marked differences in performance between photo-optical and mechanical coagulometers. Thromb Haemost. 1999;81:758–62.PubMed
25.
Zurück zum Zitat Kershaw G, Suresh S, Orellana D, Nguy YM. Laboratory identification of lupus anticoagulants. Semin Thromb Hemost. 2012;38:375–84.CrossRefPubMed Kershaw G, Suresh S, Orellana D, Nguy YM. Laboratory identification of lupus anticoagulants. Semin Thromb Hemost. 2012;38:375–84.CrossRefPubMed
26.
Zurück zum Zitat Bijsterveld NR, Middeldorp S, Berends F, Büller HR. Monitoring therapy with vitamin K antagonists in patients with lupus anticoagulant: effect on different tests for INR determination. J Thromb Thrombolysis. 2000;9:263–9.CrossRefPubMed Bijsterveld NR, Middeldorp S, Berends F, Büller HR. Monitoring therapy with vitamin K antagonists in patients with lupus anticoagulant: effect on different tests for INR determination. J Thromb Thrombolysis. 2000;9:263–9.CrossRefPubMed
27.
Zurück zum Zitat Moore GW, Savidge GF. The dilution effect of equal volume mixing studies compromises confirmation of inhibition by lupus anticoagulants even when mixture specific reference ranges are applied. Thromb Res. 2006;118:523–8.CrossRefPubMed Moore GW, Savidge GF. The dilution effect of equal volume mixing studies compromises confirmation of inhibition by lupus anticoagulants even when mixture specific reference ranges are applied. Thromb Res. 2006;118:523–8.CrossRefPubMed
28.
Zurück zum Zitat McGlasson DL, Fritsma GA. Comparison of six dilute russell viper venom time lupus anticoagulant screen/confirm assay kits. Semin Thromb Hemost. 2013;39:315–9.CrossRefPubMed McGlasson DL, Fritsma GA. Comparison of six dilute russell viper venom time lupus anticoagulant screen/confirm assay kits. Semin Thromb Hemost. 2013;39:315–9.CrossRefPubMed
Metadaten
Titel
Clinical usefulness of the dilute Russell viper venom time test for patients taking warfarin
verfasst von
Kazunori Kanouchi
Hiroto Narimatsu
Okio Ohnuma
Keita Morikane
Akira Fukao
Publikationsdatum
07.04.2017
Verlag
Springer Japan
Erschienen in
International Journal of Hematology / Ausgabe 2/2017
Print ISSN: 0925-5710
Elektronische ISSN: 1865-3774
DOI
https://doi.org/10.1007/s12185-017-2228-y

Weitere Artikel der Ausgabe 2/2017

International Journal of Hematology 2/2017 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.