An alternative to median sternotomy for epicardial placement of an implantable cardioverter defibrillator (ICD) lead in a child with hypertrophic cardiomyopathy is described. Implantation of an ICD lead via the tricuspid valve was avoided by the use of an epicardial pacing lead and a transvenous defibrillator lead placed in the vena brachiocephalica. The abdominal, subcostal pocket incision was used for an anterolateral minithoracotomy to implant the epicardial pacing lead.
Literatur
1.
Zurück zum Zitat Brady PA, Friedman PA, Trusty JM, Grice S, Hammill SC, Stanton MS (1998) High failure rate for an epicardial implantable cardioverter-defibrillator lead: implications for long-term follow-up of patients with an implantable cardioverter-defibrillator. J Am Coll Cardiol 31:616–622CrossRefPubMed Brady PA, Friedman PA, Trusty JM, Grice S, Hammill SC, Stanton MS (1998) High failure rate for an epicardial implantable cardioverter-defibrillator lead: implications for long-term follow-up of patients with an implantable cardioverter-defibrillator. J Am Coll Cardiol 31:616–622CrossRefPubMed
2.
Zurück zum Zitat Bryant R III, Aboutalebi A, Kim JJ, Kertesz N, Morales DL (2011) Epicardial implantable cardioverter-defibrillator system placed in a 4.9-kg infant. Tex Heart Inst J 38:421–423PubMedCentralPubMed Bryant R III, Aboutalebi A, Kim JJ, Kertesz N, Morales DL (2011) Epicardial implantable cardioverter-defibrillator system placed in a 4.9-kg infant. Tex Heart Inst J 38:421–423PubMedCentralPubMed
3.
Zurück zum Zitat Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G (1999) A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med 341:1882–1890CrossRefPubMed Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G (1999) A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med 341:1882–1890CrossRefPubMed
4.
Zurück zum Zitat Chaney MA (2006) Intrathecal and epidural anesthesia and analgesia for cardiac surgery. Anesth Analg 102:45–64CrossRefPubMed Chaney MA (2006) Intrathecal and epidural anesthesia and analgesia for cardiac surgery. Anesth Analg 102:45–64CrossRefPubMed
5.
Zurück zum Zitat Eicken A, Kolb C, Lange S et al (2006) Implantable cardioverter defibrillator (ICD) in children. Int J Cardiol 107:30–35CrossRefPubMed Eicken A, Kolb C, Lange S et al (2006) Implantable cardioverter defibrillator (ICD) in children. Int J Cardiol 107:30–35CrossRefPubMed
7.
Zurück zum Zitat Krishnan A, Moulick A, Sinha P et al (2009) Severe tricuspid valve stenosis secondary to pacemaker leads presenting as ascites and liver dysfunction: a complex problem requiring a multidisciplinary therapeutic approach. J Interv Card Electrophysiol 24:71–75CrossRefPubMed Krishnan A, Moulick A, Sinha P et al (2009) Severe tricuspid valve stenosis secondary to pacemaker leads presenting as ascites and liver dysfunction: a complex problem requiring a multidisciplinary therapeutic approach. J Interv Card Electrophysiol 24:71–75CrossRefPubMed
8.
Zurück zum Zitat Maron BJ, Spirito P, Shen WK et al (2007) Implantable cardioverter-defibrillators and prevention of sudden cardiac death in hypertrophic cardiomyopathy. JAMA 298:405–412PubMed Maron BJ, Spirito P, Shen WK et al (2007) Implantable cardioverter-defibrillators and prevention of sudden cardiac death in hypertrophic cardiomyopathy. JAMA 298:405–412PubMed
9.
Zurück zum Zitat Mishaly D, Ghosh P, Preisman S (2008) Minimally invasive congenital cardiac surgery through right anterior minithoracotomy approach. Ann Thorac Surg 85:831–835CrossRefPubMed Mishaly D, Ghosh P, Preisman S (2008) Minimally invasive congenital cardiac surgery through right anterior minithoracotomy approach. Ann Thorac Surg 85:831–835CrossRefPubMed
10.
Zurück zum Zitat Palma G, Giordano R, Russolillo V et al (2009) Anterolateral minithoracotomies for the radical correction of congenital heart diseases. Tex Heart Inst J 36:575–579PubMedCentralPubMed Palma G, Giordano R, Russolillo V et al (2009) Anterolateral minithoracotomies for the radical correction of congenital heart diseases. Tex Heart Inst J 36:575–579PubMedCentralPubMed
11.
Zurück zum Zitat Schreiber C, Kostolny M, Eicken A, Lange R (2006) Nonthoracotomy cardioverter defibrillator implantation in a 2-year-old infant with long QT syndrome. Ann Thorac Surg 81:e27–e28CrossRefPubMed Schreiber C, Kostolny M, Eicken A, Lange R (2006) Nonthoracotomy cardioverter defibrillator implantation in a 2-year-old infant with long QT syndrome. Ann Thorac Surg 81:e27–e28CrossRefPubMed
12.
Zurück zum Zitat Spirito P, Bellone P, Harris KM, Bernabo P, Bruzzi P, Maron BJ (2000) Magnitude of left ventricular hypertrophy and risk of sudden death in hypertrophic cardiomyopathy. N Engl J Med 342:1778–1785CrossRefPubMed Spirito P, Bellone P, Harris KM, Bernabo P, Bruzzi P, Maron BJ (2000) Magnitude of left ventricular hypertrophy and risk of sudden death in hypertrophic cardiomyopathy. N Engl J Med 342:1778–1785CrossRefPubMed
13.
Zurück zum Zitat Taira K, Suzuki A, Fujino A, Watanabe T, Ogyu A, Ashikawa K (2006) Tricuspid valve stenosis related to subvalvular adhesion of pacemaker lead: a case report. J Cardiol 47:301–306PubMed Taira K, Suzuki A, Fujino A, Watanabe T, Ogyu A, Ashikawa K (2006) Tricuspid valve stenosis related to subvalvular adhesion of pacemaker lead: a case report. J Cardiol 47:301–306PubMed
Metadaten
Titel
Combined Epicardial and Transvenous Placement of an Implantable Cardioverter Defibrillator (ICD) Lead Without a Median Sternotomy in an 8-Year-Old Child
verfasst von
Stefan Pokall
Jürgen Hörer
Christian Schreiber
Publikationsdatum
01.12.2013
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 8/2013
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-012-0544-9

Weitere Artikel der Ausgabe 8/2013

Pediatric Cardiology 8/2013 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.