Skip to main content
Erschienen in: BMC Cardiovascular Disorders 1/2020

Open Access 01.12.2020 | Case report

Combined pulmonary vein stenosis stenting and left atrial appendage occlusion in a patient with hemoptysis after atrial fibrillation ablation

verfasst von: Yan-Jie Li, Xin Pan, Cheng Wang, Ben He

Erschienen in: BMC Cardiovascular Disorders | Ausgabe 1/2020

Abstract

Background

Pulmonary vein stenosis (PVS) after radiofrequency ablation for non-valvular atrial fibrillation (AF) is an uncommon but serious complication. PVS stenting can rapidly restore pulmonary flow and improve symptoms with long-term low incidence of restenosis. However, high risk of thrombosis remains if AF is recurrent, especially for CHA2DS2-VASc > 2.

Case presentation

A 67-year-old man with diabetes, hypertension and a history of stroke underwent radiofrequency pulmonary vein isolation for persistent AF 1 year ago. Six months later he developed recurrent respiratory infection and massive hemoptysis. Computed tomography pulmonary angiography revealed severe left pulmonary vein stenosis. Simultaneous percutaneous PVS stenting and left atrial appendage occlusion were performed to resolve recurrent hemoptysis and prevent stroke. The clinical follow-up indicated a good short and mid-term result with significant improvement of symptoms.

Conclusions

Simultaneous PVS stenting and left atrial appendage occlusion is feasible and effective in patients with recurrence of AF and hemoptysis induced by radiofrequency ablation for AF.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
AF
Atrial fibrillation
CT
Computed tomography
CTPA
Computed tomography pulmonary angiography
DAPT
Dual antiplatelet therapy
DRT
Device-related thrombus
LA
Left atrium
LAAO
Left atrial appendage occlusion
LIPV
Left inferior pulmonary vein
LSPV
Left superior pulmonary vein
LV
Left ventricle
PV
Pulmonary vein
PVS
Pulmonary vein stenosis
TEE
Transesophageal echocardiography
WM
Watchman

Background

Pulmonary vein stenosis (PVS) is an uncommon but potentially serious complication following catheter ablation for atrial fibrillation (AF) [1]. Obviously, in symptomatic cases with severe PVS, early PVS stenting is needed to restore pulmonary flow [2, 3]. However, high risk of cardiac thrombosis remains if AF is recurrent. In such situations with co-existing bleeding complication, left atrial appendage occlusion (LAAO), currently regarded as a non-inferior alternative to anticoagulation in patients with non-valvular AF [4, 5], is useful to reduce the risk of thrombosis and bleeding. Here, we report a case of simultaneous percutaneous PVS stenting and LAAO to resolve the dilemma.

Case presentation

A 67-year-old man with diabetes, hypertension and a history of stroke underwent radiofrequency pulmonary vein (PV) isolation for persistent AF 1 year ago. Six months later he developed recurrent respiratory infection and massive hemoptysis. Electrocardiogram showed recurrence of AF. Warfarin was initially started but discontinued due to hemoptysis. Metoprolol was used for rate control. Computed tomography pulmonary angiography (CTPA) revealed severe left PV stenosis (Fig. 1a). He was admitted in our hospital for further treatment.
The patient was at high risk of AF-related stroke (CHA2DS2-VASc score = 5) and bleeding (HAS-BLED score = 3). In addition, risk of PV re-stenosis and recurrence of hemoptysis made long-term oral anticoagulation unfavorable in this patient.
We thus attempted to combine percutaneous PVS stenting and LAAO to resolve the problem. For percutaneous PVS stenting, we started with left pulmonary artery wedge angiography and direct selective PV angiography. As a result, severe stenosis at the ostium of left superior and inferior PV were visualized. New vascular plexus distal to the stenosis was highly suspected as the source of hemorrhage (Fig. 1b, c). Step-by-step balloon dilation of the conduit was firstly performed, and then two relatively big bare metal stents (9*25 mm and 8*27 mm; Boston Scientific, Natick, Massachusetts, USA) were successfully deployed in the proximal left superior and inferior PV respectively. PV angiography demonstrated no residual stenosis, rupture or dissection of the lesion (Fig. 1d, e). The transstenotic pressure gradient was decreased from 22 mmHg to 0 mmHg. Pulmonary vein caliber was significantly increased from 2.1 mm to 8.5 mm, and pulmonary artery pressure was decreased from 52/21 mmHg (31 mmHg) to 32/20 mmHg (24 mmHg). For LAAO, a Watchman Double Curve Access System was advanced into left atrium (LA) over the guidewire. Left atrial appendage (LAA) angiography revealed the whole lobe (Fig. 1f), and the ostial diameter was measured to be 23–25 mm by angiography and transesophageal echocardiography (TEE) views. Thereafter, a 30 mm Watchman occluder was deployed under fluoroscopy and TEE guidance (Fig. 1g, h). Once no significant peridevice leak was found and all release criteria were confirmed, the device was fully released. Heparin (80 IU/kg) was used during the procedure and activated clotting time was maintained as 250 s - 350 s.
After the procedure, the patient experienced immediate relief of symptoms. Then he received a combination of Aspirin and Clopidogrel for 6 months followed by Aspirin only indefinitely. The patient was followed at 3, 6 and 12 months. He remained asymptomatic without bleeding recurrence. CT scan was performed at 6 months and showed restored pulmonary venous flow (Fig. 2a), no in-stent restenosis (Fig. 2b, c) and no device related thrombosis (DRT) with regard to Watchman (Fig. 2d).

Discussion and conclusions

PVS after radiofrequency ablation is an uncommon but serious complication [6]. In symptomatic cases, PVS stenting can provide hemodynamic relief of pulmonary circulation [2]. However, like our patient, who had a bleeding complication and relative contraindication to chronic oral anticoagulation with warfarin or NOACs, the potential risk of LAA thrombosis and concomitant stroke are challenging. Re-Do ablations are possible in PVS after stents implantation, but the clinical benefit should be carefully considered and ostial ablation should be avoided [7]. Thus, stroke prophylaxis is of significance in the situation. While this case is performed combining with LAAO, these risks could be substantially reduced [8].
The current case illustrates the safety and feasibility of simultaneous PVS stenting and LAAO in such situation. Our experience of this procedure is that PV stenting should be first successfully performed; left superior PV stent should not be placed too close to the LA body. Sequentially, the Watchman Access Sheath should be advanced slowly to avoid interfering with PV stent.
In conclusion, the strategy of PVS stenting combined with LAAO can solve the dilemma of bleeding and thromboembolism. During the procedure, we deployed the large stent in the stenotic PV followed by dual antiplatelet therapy per the ASAP registry regimen [9]. The patient had good short and mid-term results upon follow up.

Acknowledgments

Not applicable.
Not applicable.
Written informed consent was obtained from the study participant.

Competing interests

All the authors declare no potential conflict of interest.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Yu D, Jie B, Li LL, Jiang S. Bilateral pulmonary vein stenting for treatment of massive hemoptysis caused by pulmonary vein stenosis following catheter ablation for atrial fibrillation. BMC Cardiovasc Disord. 2019;19(1):162.CrossRef Yu D, Jie B, Li LL, Jiang S. Bilateral pulmonary vein stenting for treatment of massive hemoptysis caused by pulmonary vein stenosis following catheter ablation for atrial fibrillation. BMC Cardiovasc Disord. 2019;19(1):162.CrossRef
2.
Zurück zum Zitat Li YJ, Pan X, Wang C, He B. Stent implantation for severe pulmonary vein stenosis or occlusion secondary to atrial fibrillation ablation. Int J Cardiol. 2020;301:85–9.CrossRef Li YJ, Pan X, Wang C, He B. Stent implantation for severe pulmonary vein stenosis or occlusion secondary to atrial fibrillation ablation. Int J Cardiol. 2020;301:85–9.CrossRef
3.
Zurück zum Zitat Fender EA, Widmer RJ, Hodge DO, Packer DL, Holmes DR Jr. Assessment and management of pulmonary vein occlusion after atrial fibrillation ablation. JACC Cardiovasc Interv. 2018;11(16):1633–9.CrossRef Fender EA, Widmer RJ, Hodge DO, Packer DL, Holmes DR Jr. Assessment and management of pulmonary vein occlusion after atrial fibrillation ablation. JACC Cardiovasc Interv. 2018;11(16):1633–9.CrossRef
4.
Zurück zum Zitat Glikson M, Wolff R, Hindricks G, Mandrola J, Camm AJ, Lip GYH, et al. EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion - an update. EuroIntervention. 2020;15(13):1133–80.CrossRef Glikson M, Wolff R, Hindricks G, Mandrola J, Camm AJ, Lip GYH, et al. EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion - an update. EuroIntervention. 2020;15(13):1133–80.CrossRef
5.
Zurück zum Zitat Fastner C, Hoffmann L, Aboukoura M, Behnes M, Lang S, Borggrefe M, et al. Real-world experience comparing two common left atrial appendage closure devices. BMC Cardiovasc Disord. 2018;18(1):171.CrossRef Fastner C, Hoffmann L, Aboukoura M, Behnes M, Lang S, Borggrefe M, et al. Real-world experience comparing two common left atrial appendage closure devices. BMC Cardiovasc Disord. 2018;18(1):171.CrossRef
6.
Zurück zum Zitat Padala SK, Ellenbogen KA. Pulmonary vein stenosis after atrial fibrillation ablation: an iatrogenic problem larger than the primary problem. Circ Arrhythm Electrophysiol. 2018;11(5):e006461.CrossRef Padala SK, Ellenbogen KA. Pulmonary vein stenosis after atrial fibrillation ablation: an iatrogenic problem larger than the primary problem. Circ Arrhythm Electrophysiol. 2018;11(5):e006461.CrossRef
7.
Zurück zum Zitat Raeisi-Giglou P, Wazni OM, Saliba WI, Barakat A, Tarakji KG, Rickard J, et al. Outcomes and management of patients with severe pulmonary vein stenosis from prior atrial fibrillation ablation. Circ Arrhythm Electrophysiol. 2018;11(5):e006001.CrossRef Raeisi-Giglou P, Wazni OM, Saliba WI, Barakat A, Tarakji KG, Rickard J, et al. Outcomes and management of patients with severe pulmonary vein stenosis from prior atrial fibrillation ablation. Circ Arrhythm Electrophysiol. 2018;11(5):e006001.CrossRef
8.
Zurück zum Zitat Reddy VY, Doshi SK, Kar S, Gibson DN, Price MJ, Huber K, et al. 5-year outcomes after left atrial appendage closure: from the PREVAIL and PROTECT AF trials. J Am Coll Cardiol. 2017;70(24):2964–75.CrossRef Reddy VY, Doshi SK, Kar S, Gibson DN, Price MJ, Huber K, et al. 5-year outcomes after left atrial appendage closure: from the PREVAIL and PROTECT AF trials. J Am Coll Cardiol. 2017;70(24):2964–75.CrossRef
9.
Zurück zum Zitat Sharma D, Reddy VY, Sandri M, Schulz P, Majunke N, Hala P, et al. Left atrial appendage closure in patients with contraindications to oral anticoagulation. J Am Coll Cardiol. 2016;67(18):2190–2.CrossRef Sharma D, Reddy VY, Sandri M, Schulz P, Majunke N, Hala P, et al. Left atrial appendage closure in patients with contraindications to oral anticoagulation. J Am Coll Cardiol. 2016;67(18):2190–2.CrossRef
Metadaten
Titel
Combined pulmonary vein stenosis stenting and left atrial appendage occlusion in a patient with hemoptysis after atrial fibrillation ablation
verfasst von
Yan-Jie Li
Xin Pan
Cheng Wang
Ben He
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
BMC Cardiovascular Disorders / Ausgabe 1/2020
Elektronische ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-020-01483-4

Weitere Artikel der Ausgabe 1/2020

BMC Cardiovascular Disorders 1/2020 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.