Comparable accuracy of femoral joint line reconstruction in different kinematic and functional alignment techniques

verfasst von: Lars-Rene Tuecking, Peter Savov, Mats Zander, Dragan Jeremic, Henning Windhagen, Max Ettinger

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 9/2023

Einloggen, um Zugang zu erhalten

Abstract

Purpose

A key part of kinematic alignment (KA) and functional alignment (FA) is to restore the natural femoral joint line, in particular the medial joint line. KA is known to reproduce the femoral joint line accurately; however, direct comparisons with other surgical techniques such as FA are currently lacking. The purpose of this study was to evaluate differences of alignment parameters in KA and FA techniques with a special focus given to the femoral joint line.

Methods

We performed a retrospective radiological analysis of pre- and postoperative long leg radiographs of 221 consecutive patients with varus or neutral leg alignment, who underwent primary total knee arthroplasty (TKA) procedures from 2018 to 2020. Patients were assigned to one of four groups: (1) FA: image-based robotic-assisted TKA, (2) FA: imageless robotic-assisted TKA, (3): restricted KA: 3D cutting block-assisted (patient-specific instruments, PSI) TKA, (4): unrestricted KA: calipered technique. Patients’ radiographs were (re)-analyzed for overall limb alignment, medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), as well as medial and lateral femoral joint line alteration. Statistical significance was determined using unpaired t testing (FA vs. KA group) and one-way ANOVA (subgroup analyses).

Results

Comparisons of KA vs. FA, as well as individual subgroups of KA and FA did not show any differences in the accuracy of medial joint line reconstruction (< 2 mm, p = 0.384, p = 0.744, respectively) and LDFA alteration (< 2°, p = 0.997, 0.921, respectively). Correction of MPTA (3.4° vs. 2.2°) and lateral femoral joint line (2.1 mm vs. 1.5 mm) was higher for FA and FA subgroups compared to KA and KA subgroups (both p < 0.001).

Conclusion

Kinematic and functional alignments showed a comparable accuracy in reconstruction of the medial femoral joint line and femoral joint line orientation. Increased correction of MPTA and lateral femoral joint line was recorded with FA techniques.

Level of evidence

III.
Literatur
1.
Zurück zum Zitat Agrawal VO, Gadekar AP, Vaidya N (2022) Does robotic technology successfully restore the joint line after total knee arthroplasty? A retrospective analysis. Arthroplasty 4:6CrossRefPubMedPubMedCentral Agrawal VO, Gadekar AP, Vaidya N (2022) Does robotic technology successfully restore the joint line after total knee arthroplasty? A retrospective analysis. Arthroplasty 4:6CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Chang JS, Kayani B, Wallace C, Haddad FS (2021) Functional alignment achieves soft-tissue balance in total knee arthroplasty as measured with quantitative sensor-guided technology. Bone Jt J 103-B:507–514CrossRef Chang JS, Kayani B, Wallace C, Haddad FS (2021) Functional alignment achieves soft-tissue balance in total knee arthroplasty as measured with quantitative sensor-guided technology. Bone Jt J 103-B:507–514CrossRef
3.
Zurück zum Zitat D’Amato M, Kosse NM, Wymenga AB (2021) Restoration of pre-operative joint line orientation and alignment does not affect KSS and KOOS 1 year after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 29:3170–3177CrossRefPubMed D’Amato M, Kosse NM, Wymenga AB (2021) Restoration of pre-operative joint line orientation and alignment does not affect KSS and KOOS 1 year after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 29:3170–3177CrossRefPubMed
4.
Zurück zum Zitat Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J (2007) An ABJS BEST PAPER: difference between the epicondylar and cylindrical axis of the knee. Clin Orthop 461:238–244CrossRefPubMed Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J (2007) An ABJS BEST PAPER: difference between the epicondylar and cylindrical axis of the knee. Clin Orthop 461:238–244CrossRefPubMed
5.
Zurück zum Zitat Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG (1993) The axes of rotation of the knee. Clin Orthop 290:259–268CrossRef Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG (1993) The axes of rotation of the knee. Clin Orthop 290:259–268CrossRef
6.
Zurück zum Zitat Howell SM (2019) Calipered kinematically aligned total knee arthroplasty: an accurate technique that improves patient outcomes and implant survival. Orthopedics 42:126–135CrossRefPubMed Howell SM (2019) Calipered kinematically aligned total knee arthroplasty: an accurate technique that improves patient outcomes and implant survival. Orthopedics 42:126–135CrossRefPubMed
7.
Zurück zum Zitat Howell SM, Nedopil AJ, Hull ML (2022) Negligible effect of surgeon experience on the accuracy and time to perform unrestricted caliper verified kinematically aligned TKA with manual instruments. Knee Surg Sports Traumatol Arthrosc 30:2966–2974CrossRefPubMedPubMedCentral Howell SM, Nedopil AJ, Hull ML (2022) Negligible effect of surgeon experience on the accuracy and time to perform unrestricted caliper verified kinematically aligned TKA with manual instruments. Knee Surg Sports Traumatol Arthrosc 30:2966–2974CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Kayani B, Konan S, Ayuob A, Onochie E, Al-Jabri T, Haddad FS (2019) Robotic technology in total knee arthroplasty: a systematic review. EFORT Open Rev 4:611–617CrossRefPubMedPubMedCentral Kayani B, Konan S, Ayuob A, Onochie E, Al-Jabri T, Haddad FS (2019) Robotic technology in total knee arthroplasty: a systematic review. EFORT Open Rev 4:611–617CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Kim J-T, Han J, Lim S, Shen QH, Won YY (2019) Kinematically aligned TKA aligns the ankle joint line closer to those of the native ankle than mechanically aligned TKA in bipedal stance. J Knee Surg 32:1033–1038CrossRefPubMed Kim J-T, Han J, Lim S, Shen QH, Won YY (2019) Kinematically aligned TKA aligns the ankle joint line closer to those of the native ankle than mechanically aligned TKA in bipedal stance. J Knee Surg 32:1033–1038CrossRefPubMed
10.
Zurück zum Zitat Li G, Park SE, DeFrate LE, Schutzer ME, Ji L, Gill TJ, Rubash HE (2005) The cartilage thickness distribution in the tibiofemoral joint and its correlation with cartilage-to-cartilage contact. Clin Biomech Bristol Avon 20:736–744CrossRefPubMed Li G, Park SE, DeFrate LE, Schutzer ME, Ji L, Gill TJ, Rubash HE (2005) The cartilage thickness distribution in the tibiofemoral joint and its correlation with cartilage-to-cartilage contact. Clin Biomech Bristol Avon 20:736–744CrossRefPubMed
11.
Zurück zum Zitat Liow MHL, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL (2014) Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplasty 29:2373–2377CrossRefPubMed Liow MHL, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL (2014) Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplasty 29:2373–2377CrossRefPubMed
12.
Zurück zum Zitat Luyckx T, Vandenneucker H, Ing LS, Vereecke E, Ing AV, Victor J (2018) Raising the joint line in TKA is associated with mid-flexion laxity: a study in cadaver knees. Clin Orthop 476:601–611CrossRefPubMedPubMedCentral Luyckx T, Vandenneucker H, Ing LS, Vereecke E, Ing AV, Victor J (2018) Raising the joint line in TKA is associated with mid-flexion laxity: a study in cadaver knees. Clin Orthop 476:601–611CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat MacDessi SJ, Griffiths-Jones W, Harris IA, Bellemans J, Chen DB (2021) Coronal plane alignment of the knee (CPAK) classification: a new system for describing knee phenotypes. Bone Jt J 103-B:329–337CrossRef MacDessi SJ, Griffiths-Jones W, Harris IA, Bellemans J, Chen DB (2021) Coronal plane alignment of the knee (CPAK) classification: a new system for describing knee phenotypes. Bone Jt J 103-B:329–337CrossRef
14.
Zurück zum Zitat Nedopil AJ, Howell SM, Hull ML (2020) Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomes. Knee Surg Sports Traumatol Arthrosc 28:3118–3127CrossRefPubMed Nedopil AJ, Howell SM, Hull ML (2020) Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomes. Knee Surg Sports Traumatol Arthrosc 28:3118–3127CrossRefPubMed
15.
Zurück zum Zitat Niki Y, Nagura T, Nagai K, Kobayashi S, Harato K (2018) Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 26:1629–1635CrossRefPubMed Niki Y, Nagura T, Nagai K, Kobayashi S, Harato K (2018) Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 26:1629–1635CrossRefPubMed
16.
Zurück zum Zitat Oussedik S, Abdel MP, Victor J, Pagnano MW, Haddad FS (2020) Alignment in total knee arthroplasty: what’s in a name? Bone Jt J 102-B:276–279CrossRef Oussedik S, Abdel MP, Victor J, Pagnano MW, Haddad FS (2020) Alignment in total knee arthroplasty: what’s in a name? Bone Jt J 102-B:276–279CrossRef
17.
Zurück zum Zitat Rivière C, Harman C, Boughton O, Cobb J (2020) The kinematic alignment technique for total knee arthroplasty. In: Rivière C, Vendittoli P-A (eds) Pers hip knee jt replace. Springer International Publishing, Cham, pp 175–195CrossRef Rivière C, Harman C, Boughton O, Cobb J (2020) The kinematic alignment technique for total knee arthroplasty. In: Rivière C, Vendittoli P-A (eds) Pers hip knee jt replace. Springer International Publishing, Cham, pp 175–195CrossRef
18.
Zurück zum Zitat Rivière C, Iranpour F, Harris S, Auvinet E, Aframian A, Chabrand P, Cobb J (2017) The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis. Orthop Traumatol Surg Res 103:1069–1073CrossRefPubMed Rivière C, Iranpour F, Harris S, Auvinet E, Aframian A, Chabrand P, Cobb J (2017) The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis. Orthop Traumatol Surg Res 103:1069–1073CrossRefPubMed
19.
Zurück zum Zitat Sappey-Marinier E, Batailler C, Swan J, Schmidt A, Cheze L, MacDessi SJ, Servien E, Lustig S (2021) Mechanical alignment for primary TKA may change both knee phenotype and joint line obliquity without influencing clinical outcomes: a study comparing restored and unrestored joint line obliquity. Knee Surg Sports Traumatol Arthrosc 30:2806–2814CrossRefPubMed Sappey-Marinier E, Batailler C, Swan J, Schmidt A, Cheze L, MacDessi SJ, Servien E, Lustig S (2021) Mechanical alignment for primary TKA may change both knee phenotype and joint line obliquity without influencing clinical outcomes: a study comparing restored and unrestored joint line obliquity. Knee Surg Sports Traumatol Arthrosc 30:2806–2814CrossRefPubMed
20.
Zurück zum Zitat Shah RF, Martinez AM, Pedoia V, Majumdar S, Vail TP, Bini SA (2019) Variation in the thickness of knee cartilage. The use of a novel machine learning algorithm for cartilage segmentation of magnetic resonance images. J Arthroplasty 34:2210–2215CrossRefPubMedPubMedCentral Shah RF, Martinez AM, Pedoia V, Majumdar S, Vail TP, Bini SA (2019) Variation in the thickness of knee cartilage. The use of a novel machine learning algorithm for cartilage segmentation of magnetic resonance images. J Arthroplasty 34:2210–2215CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Shatrov J, Battelier C, Sappey-Marinier E, Gunst S, Servien E, Lustig S (2022) Functional alignment philosophy in total knee arthroplasty—rationale and technique for the varus morphotype using a CT based robotic platform and individualized planning. SICOT-J 8:11CrossRefPubMedPubMedCentral Shatrov J, Battelier C, Sappey-Marinier E, Gunst S, Servien E, Lustig S (2022) Functional alignment philosophy in total knee arthroplasty—rationale and technique for the varus morphotype using a CT based robotic platform and individualized planning. SICOT-J 8:11CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Tuecking L-R, Ettinger M, Nebel D, Welke B, Schwarze M, Windhagen H, Savov P (2021) 3D-surface scan based validated new measurement technique of femoral joint line reconstruction in total knee arthroplasty. J Exp Orthop 8:16CrossRefPubMedPubMedCentral Tuecking L-R, Ettinger M, Nebel D, Welke B, Schwarze M, Windhagen H, Savov P (2021) 3D-surface scan based validated new measurement technique of femoral joint line reconstruction in total knee arthroplasty. J Exp Orthop 8:16CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Vaidya NV, Deshpande AN, Panjwani T, Patil R, Jaysingani T, Patil P (2020) Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 30:621–626CrossRefPubMed Vaidya NV, Deshpande AN, Panjwani T, Patil R, Jaysingani T, Patil P (2020) Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 30:621–626CrossRefPubMed
Metadaten
Titel
Comparable accuracy of femoral joint line reconstruction in different kinematic and functional alignment techniques
verfasst von
Lars-Rene Tuecking
Peter Savov
Mats Zander
Dragan Jeremic
Henning Windhagen
Max Ettinger
Publikationsdatum
14.03.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 9/2023
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-023-07360-9

Weitere Artikel der Ausgabe 9/2023

Knee Surgery, Sports Traumatology, Arthroscopy 9/2023 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.