Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 10/2005

01.12.2005 | Original Article

Comparative surface examinations on corund blasted titanium implants and explants in total hip arthroplasty

verfasst von: Alexander Schuh, Wolfgang Uter, Werner Kachler, Jürgen Göske, Günther Zeiler, Christoph Lill

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 10/2005

Einloggen, um Zugang zu erhalten

Abstract

Introduction: Blasting techniques using corundum to create rough surfaces are used in many different processes for the surface treatment of hip implants. Recent evidence points an association between residual particles and early loosenings in the sense of third-body wear. Materials and method: The surfaces of five unused, original-packaged CLS stems and ARR-Titan supporting rings, respectively, were compared with five explanted CLS stems and ARR-Titan supporting rings. Results: The surface of the ARR-Titan supporting rings was adhered to Al2O3 particles at 23.2±2.5% on the implants and 12.3±3.0% on the explants (P<0.0001). For the CLS stem, the surface to which Al2O3 particles adhered was 16.4±2.2 % on the implants, whereas the surface to which Al2O3 particles adhered was 12.4±3.3% on the explants (P=0.0275). Discussion: The results of this study show that corundum particles can be found to cover a high percentage on rough-blasted titanium surfaces of ready-to-use devices. In contrast, this contamination is significantly less on the explants treated in an identical fashion prior to implantation.
Literatur
1.
Zurück zum Zitat Aldinger PR, Breusch SJ, Lukoschek M, Mau H, Ewerbeck V, Thomsen M (2003) A ten- to fifteen-year follow-up of the cementless Spotorno stem. J Bone Joint Surg 85-B:209–214CrossRef Aldinger PR, Breusch SJ, Lukoschek M, Mau H, Ewerbeck V, Thomsen M (2003) A ten- to fifteen-year follow-up of the cementless Spotorno stem. J Bone Joint Surg 85-B:209–214CrossRef
2.
Zurück zum Zitat Böhler M, Kanz F, Schwarz B, Steffan I, Walter A, Plenk H Jr, Knahr K (2002) Adverse tissue reactions to wear particles from Co-alloy articulations, increased by alumina-blasting particle contamination from cementless Ti-based total hip implants. A report of seven revisions with early failure. J Bone Joint Surg 84-B:128–136CrossRef Böhler M, Kanz F, Schwarz B, Steffan I, Walter A, Plenk H Jr, Knahr K (2002) Adverse tissue reactions to wear particles from Co-alloy articulations, increased by alumina-blasting particle contamination from cementless Ti-based total hip implants. A report of seven revisions with early failure. J Bone Joint Surg 84-B:128–136CrossRef
3.
Zurück zum Zitat Bos I (2001) Tissue reactions around loosened hip joint endoprostheses. A histological study of secondary capsules and interface membranes. Orthopäde 30:881–889CrossRefPubMed Bos I (2001) Tissue reactions around loosened hip joint endoprostheses. A histological study of secondary capsules and interface membranes. Orthopäde 30:881–889CrossRefPubMed
4.
Zurück zum Zitat Catelas I, Huk OL, Petit A, Zukor DJ, Marchand R, Yahia L (1998) Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: effects of size, concentration, and composition. J Biomed Mater Res 41:600–607CrossRefPubMed Catelas I, Huk OL, Petit A, Zukor DJ, Marchand R, Yahia L (1998) Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: effects of size, concentration, and composition. J Biomed Mater Res 41:600–607CrossRefPubMed
5.
Zurück zum Zitat Catelas I, Petit A, Marchand R, Zukor DJ, Yahia L, Huk OL (1999) Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro. J Bone Joint Surg 81-B:516–521CrossRef Catelas I, Petit A, Marchand R, Zukor DJ, Yahia L, Huk OL (1999) Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro. J Bone Joint Surg 81-B:516–521CrossRef
6.
Zurück zum Zitat Catelas I, Petit A, Zukor DJ, Marchand R, Yahia L, Huk OL (1999) Induction of macrophage apoptosis by ceramic and polyethylene particles in vitro. Biomaterials 20:625–630CrossRefPubMed Catelas I, Petit A, Zukor DJ, Marchand R, Yahia L, Huk OL (1999) Induction of macrophage apoptosis by ceramic and polyethylene particles in vitro. Biomaterials 20:625–630CrossRefPubMed
7.
Zurück zum Zitat Darvell BW, Sammant N, Luk WK, Clark RKF, Tideman H (1995) Contamination of titanium castings by aluminium oxide blasting. J Dent 23:319–322CrossRefPubMed Darvell BW, Sammant N, Luk WK, Clark RKF, Tideman H (1995) Contamination of titanium castings by aluminium oxide blasting. J Dent 23:319–322CrossRefPubMed
8.
Zurück zum Zitat Dhert WJ, Klein CP, Jansen JA, van der Velde EA, Vriesde RC, Rozing PM, de Groot K (1993) A histological and histomorphometrical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma-sprayed coatings in goats. J Biomed Mater Res 27:127–138CrossRefPubMed Dhert WJ, Klein CP, Jansen JA, van der Velde EA, Vriesde RC, Rozing PM, de Groot K (1993) A histological and histomorphometrical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma-sprayed coatings in goats. J Biomed Mater Res 27:127–138CrossRefPubMed
9.
Zurück zum Zitat Goldberg VM, Stevenson S, Feighan J, Davy D (1995) Biology of gritblasted titanium alloy implants. Clin Orthop 319:122–129PubMed Goldberg VM, Stevenson S, Feighan J, Davy D (1995) Biology of gritblasted titanium alloy implants. Clin Orthop 319:122–129PubMed
10.
Zurück zum Zitat Grübl A, Kolb A, Reinisch G, Gottsauner-Wolf F (2002) REM- Analyse von korundgestrahlten Hüft- TEP- Schäften. Z Orthop Ihre Grenzgeb 140(Suppl.):16 Grübl A, Kolb A, Reinisch G, Gottsauner-Wolf F (2002) REM- Analyse von korundgestrahlten Hüft- TEP- Schäften. Z Orthop Ihre Grenzgeb 140(Suppl.):16
11.
Zurück zum Zitat Hatton A, Nevelos JE, Matthews JB, Fisher J, Ingham E (2003) Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes. Biomaterials 24:1193–1204CrossRefPubMed Hatton A, Nevelos JE, Matthews JB, Fisher J, Ingham E (2003) Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes. Biomaterials 24:1193–1204CrossRefPubMed
12.
Zurück zum Zitat Howie DW, Vernon-Roberts B (1988) Synovial macrophage response to aluminium oxide ceramic and cobalt-chrome alloy wear particles in rats. Biomaterials 9:442–448CrossRefPubMed Howie DW, Vernon-Roberts B (1988) Synovial macrophage response to aluminium oxide ceramic and cobalt-chrome alloy wear particles in rats. Biomaterials 9:442–448CrossRefPubMed
13.
Zurück zum Zitat Kubo T, Sawada K, Hirakawa K, Shimizu C, Takamatsu T, Hirasawa Y (1999) Histiocyte reaction in rabbit femurs to UHMWPE, metal, and ceramic particles in different sizes. J Biomed Mater Res 45:363–369CrossRefPubMed Kubo T, Sawada K, Hirakawa K, Shimizu C, Takamatsu T, Hirasawa Y (1999) Histiocyte reaction in rabbit femurs to UHMWPE, metal, and ceramic particles in different sizes. J Biomed Mater Res 45:363–369CrossRefPubMed
14.
Zurück zum Zitat Moberg LE, Nordenram A, Kjellman O (1989) Metal release from plates used in jaw fracture treatment. A pilot study. Int J Oral Maxillofac Surg 18:311–314CrossRefPubMed Moberg LE, Nordenram A, Kjellman O (1989) Metal release from plates used in jaw fracture treatment. A pilot study. Int J Oral Maxillofac Surg 18:311–314CrossRefPubMed
15.
Zurück zum Zitat Negre J, Henry F (1995) Bone reaction to contact with a granulated titanium surface. Apropos of 101 total hip prostheses with six years follow-up. Rev Chir Orthop Reparatrice Appar Mot 81:106–113PubMed Negre J, Henry F (1995) Bone reaction to contact with a granulated titanium surface. Apropos of 101 total hip prostheses with six years follow-up. Rev Chir Orthop Reparatrice Appar Mot 81:106–113PubMed
16.
Zurück zum Zitat Petit A, Catelas I, Antoniou J, Zukor DJ, Huk OL (2002) Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles. J Orthop Res 20:9–15CrossRefPubMed Petit A, Catelas I, Antoniou J, Zukor DJ, Huk OL (2002) Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles. J Orthop Res 20:9–15CrossRefPubMed
17.
Zurück zum Zitat Piatelli A, Manzon L, Scarano A, Paolantonio M, Piattelli M (1998) Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants. An experimental study in rabbits. Int J Oral Maxillofac Implants 13:805–810PubMed Piatelli A, Manzon L, Scarano A, Paolantonio M, Piattelli M (1998) Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants. An experimental study in rabbits. Int J Oral Maxillofac Implants 13:805–810PubMed
18.
Zurück zum Zitat Ricci JL, Kummer FJ, Alexander H, Casar RS (1992) Technical note: embedded particulate contaminants in textured metal implant surfaces. J Appl Biomater 3:225–230CrossRef Ricci JL, Kummer FJ, Alexander H, Casar RS (1992) Technical note: embedded particulate contaminants in textured metal implant surfaces. J Appl Biomater 3:225–230CrossRef
19.
Zurück zum Zitat Schmidt PF (1994) Praxis der Rasterelektronenmikroskopie und Mikrobereichsanalyse. Expert-Verlag, Renningen- Malsheim Schmidt PF (1994) Praxis der Rasterelektronenmikroskopie und Mikrobereichsanalyse. Expert-Verlag, Renningen- Malsheim
20.
Zurück zum Zitat Schuh A, Uter W, Holzwarth U, Kachler W, Göske J, Raab B, Knetsch T. (2005) Residual particle free rough surfaces after rough blasting with steel grit in total hip arthroplasty. Biomed Techn (Berlin), (in press) Schuh A, Uter W, Holzwarth U, Kachler W, Göske J, Raab B, Knetsch T. (2005) Residual particle free rough surfaces after rough blasting with steel grit in total hip arthroplasty. Biomed Techn (Berlin), (in press)
21.
Zurück zum Zitat Witt JD, Swann M (1991) Metal wear and tissue response in failed titanium alloy total hip replacements. J Bone Joint Surg 73-B:559–563 Witt JD, Swann M (1991) Metal wear and tissue response in failed titanium alloy total hip replacements. J Bone Joint Surg 73-B:559–563
Metadaten
Titel
Comparative surface examinations on corund blasted titanium implants and explants in total hip arthroplasty
verfasst von
Alexander Schuh
Wolfgang Uter
Werner Kachler
Jürgen Göske
Günther Zeiler
Christoph Lill
Publikationsdatum
01.12.2005
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 10/2005
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-005-0050-0

Weitere Artikel der Ausgabe 10/2005

Archives of Orthopaedic and Trauma Surgery 10/2005 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.